• 제목/요약/키워드: longitudinal damage

검색결과 245건 처리시간 0.029초

Seismic performance of RC bridge piers subjected to moderate earthquakes

  • Chung, Young Soo;Park, Chang Kyu;Lee, Dae Hyoung
    • Structural Engineering and Mechanics
    • /
    • 제24권4호
    • /
    • pp.429-446
    • /
    • 2006
  • Experimental investigation was conducted to evaluate the seismic ductility of earthquake-experienced concrete columns with an aspect ratio of 2.5. Eight circular concrete columns with a diameter of 600 mm were constructed with three test parameters: confinement ratio, lap-splice of longitudinal bars, and retrofitting with Fiber Reinforced Polymer (FRP) materials. The objective of this research is to examine the seismic performance of RC bridge piers subjected to a Quasi static test (QST), which were preliminary tested under a series of artificial earthquake motions referred to as a Pseudo dynamic test (PDT). The seismic enhancement effect of FRP wrap was also investigated on these RC bridge piers. Six specimens were loaded to induce probable damage by four series of artificial earthquakes, which were developed to be compatible with earthquakes in the Korean peninsula by the Korea Highway Corporation (KHC). Directly after the PDT, six earthquake-experienced columns were subjected to inelastic cyclic loading under a constant axial load of $0.1{f_c}^{\prime}A_g$. Two other reference specimens without the PDT were also subjected to similar quasi-static loads. Test results showed that specimens pre-damaged by moderate artificial earthquakes generally demonstrated good residual seismic performance, which was similar to the corresponding reference specimen. Moreover, RC bridge specimens retrofitted with wrapping fiber composites in the potential plastic hinge region exhibited enhanced flexural ductility.

기존 학교건물 골조와 내진보강요소 일체화를 위한 변형경화형 시멘트 복합체를 적용한 스터드 전단 접합부의 구조성능 (Structural Performance of Stud Shear Connections using SHCC between Existing School Building Frame and Seismic Retrofitting Elements)

  • 김성호;윤현도
    • 교육시설 논문지
    • /
    • 제20권4호
    • /
    • pp.35-43
    • /
    • 2013
  • Some results of experimental investigation conducted to assess the effect of cement composite strength and ductility on the shear behavior and crack-damage mitigation of stud connections between existing reinforced concrete frame in school buildings and seismic strengthening elements from cyclically direct shear tests are described. The cement composite strengths include 50 for medium strength and 70 MPa for high strength. Two types of cement composites, strain-hardening cement composite (SHCC) and non-shrinkage mortar, are used for stud shear connection specimens. The special SHCCs are reinforced with hybrid 0.2% polyethylene (PE) and 1.3% polyvinyl alcohol (PVA) fibers at the volume fraction and exhibits tensile strain capacity ranging from 0.2 to 0.5%. Test result indicates that SHCC improves the seismic performance and crack-damage mitigation of stud shear connections compared with stud connections with non-shrinkage mortar. However, the performance enhancement in SHCC stud connections with transverse and longitudinal reinforcements is less notable for those without additional reinforcement.

추력선 해석을 이용한 미얀마 파야톤주 사원의 손상 원인 분석 (Damage Cause Analysis of Phaya-Thon-Zu Temple in Myanmar Using Thrust Line Analysis)

  • 홍석일;전건우;정인기;한욱빈;김호수
    • 한국공간구조학회논문집
    • /
    • 제20권2호
    • /
    • pp.95-104
    • /
    • 2020
  • Phaya-Thon-Zu temple has a unique architectural style connected by the three temples, and cultural values are highly as murals remain on some of the walls. However, various damages in internal walls and vaults have occurred due to earthquake and environmental influences. In order to analyze these damages, accurate structural analysis is required, but structural modeling is difficult, because Phaya-Thon-Zu temple is the complex masonry structure which is stacked with small bricks. Therefore, this study intends to analyze the causes of damages by examining collapse mechanism for cross section and longitudinal section of vaults in the entrance hall and shrine by using thrust line analysis, which is a geometric method, and to compare it with the actual damage situation.

외팔보에 대한 가진력수준제어를 통한 피로균열규명기법의 실험적 검증 (Experimental Verifications of Fatigue Crack Identification Method Using Excitation Force Level Control for a Cantilever Beam)

  • 김도균;이순복
    • 대한기계학회논문집A
    • /
    • 제28권10호
    • /
    • pp.1467-1474
    • /
    • 2004
  • In this study, a new damage identification method for beam-like structures with a fatigue crack is proposed. which does not require comparative measurement on an intact structure but require several measurements at different level of excitation forces on the cracked structure. The idea comes from the fact that dynamic behavior of a structure with a fatigue crack changes with the level of the excitation force. The 2$^{nd}$ spatial derivatives of frequency response functions along the longitudinal direction of a beam are used as the sensitive indicator of crack existence. Then, weighting function is employed in the averaging process in frequency domain to account for the modal participation of the differences between the dynamic behavior of a beam with a fatigue crack at the low excitation and one at the high excitation. Subsequently, a damage index is defined such that the location and level of the crack may be identified. It is shown from the analysis of vibration measurements in this study that comparison of frequency response characteristics of a beam with a single fatigue crack at different level of excitation forces enables an effective detection of the crack.

Characteristic Behavior of High-Strength Concrete Columns under Simulated Seismic Loading

  • Hwang, Sun-Kyoung
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권2E호
    • /
    • pp.79-87
    • /
    • 2006
  • The main objective of this research is to examine the behavior of high-strength concrete(HSC) columns. Eight test columns in one-third scale were tested under the conditions of cyclic lateral force and a constant axial load equal to 30% of the column axial load capacity. The $200{\times}200mm$ square columns were reinforced with eight DB bars constituting a longitudinal steel ratio of 2.54% of the column cross-sectional area. The main experimental parameters were volumetric ratio of transverse reinforcement(${\rho}_s$=1.58, 2.25 percent), tie configuration(Type H, Type C, Type D) and tie yield strength($f_{yh}$=548.8 and 779.1 MPa). It was found that the hysteretic behaviour and ultimate deformability of HSC columns were influenced by the amount and details of transverse reinforcement in the potential plastic hinge regions. Columns of transverse reinforcement in the amount 42 percent higher than that required by seismic provisions of ACI 318-02 showed ductile behavior. At 30% of the axial load capacity, it is recommended that the yield strength of transverse reinforcement be held equal to or below 548.8 MPa. Correlations between the calculated damage index and the damage progress are proposed.

Magnetic Resonance Imaging as a Biomarker for Duchenne Muscular Dystrophy

  • Lim, Woo-taek
    • 한국전문물리치료학회지
    • /
    • 제22권3호
    • /
    • pp.98-105
    • /
    • 2015
  • Muscular dystrophy is a hereditary musculoskeletal disorder caused by a mutation in the dystrophin gene. Duchenne muscular dystrophy (DMD) is one of the most common, and progresses relatively faster than other muscular dystrophies. It is characterized by progressive myofiber degeneration, muscle weakness and ultimately ambulatory loss. Since it is an X-linked recessive inheritance, DMD is mostly expressed in males and rarely expressed or less severe in females. The most effective measurement tool for DMD is magnetic resonance imaging (MRI), which allows non-invasive examination of longitudinal measurement. It can detect progressive decline of skeletal muscle size by measuring a maximal cross-sectional area of skeletal muscle. Additionally, other techniques in MRI, like $T_2$-weighted imaging, assess muscle damage, including inflammation, by detecting changes in $T_2$ relaxation time. Current MRI techniques even allow quantification of metabolic differences between affected and non-affected muscles in DMD. There is no current cure, but physical therapist can improve their quality of life by maintaining muscle strength and function, especially if treatment (and other forms of medical intervention) begins in the early stages of the disease.

Damage detection for pipeline structures using optic-based active sensing

  • Lee, Hyeonseok;Sohn, Hoon
    • Smart Structures and Systems
    • /
    • 제9권5호
    • /
    • pp.461-472
    • /
    • 2012
  • This study proposes an optics-based active sensing system for continuous monitoring of underground pipelines in nuclear power plants (NPPs). The proposed system generates and measures guided waves using a single laser source and optical cables. First, a tunable laser is used as a common power source for guided wave generation and sensing. This source laser beam is transmitted through an optical fiber, and the fiber is split into two. One of them is used to actuate macro fiber composite (MFC) transducers for guided wave generation, and the other optical fiber is used with fiber Bragg grating (FBG) sensors to measure guided wave responses. The MFC transducers placed along a circumferential direction of a pipe at one end generate longitudinal and flexural modes, and the corresponding responses are measured using FBG sensors instrumented in the same configuration at the other end. The generated guided waves interact with a defect, and this interaction causes changes in response signals. Then, a damage-sensitive feature is extracted from the response signals using the axi-symmetry nature of the measured pitch-catch signals. The feasibility of the proposed system has been examined through a laboratory experiment.

이중선각구조 선박의 최종굽힘강도와 피로강도에 대한 안전성 평가 (Safety Assessment of Double Skin Hull Structure against Ultimate Bending and Fatigue Strength)

  • 양박달치;이주성
    • 대한조선학회논문집
    • /
    • 제29권1호
    • /
    • pp.93-102
    • /
    • 1992
  • 본 논문에서는 종굽힘하에서 이중선각구조선박의 최종굽힘강도와 피로강도에 대한 신뢰성평가를 다루었다. 최종굽힘강도는 beam-column approach의 개념을 이용하여 구하였고, 보강판의 응력-변형도 곡선들은 소성힌지의 개념을 이용하여 유도하였다. 피로강도는 피로손상에 대한 것만을 고려하였고, 이를 위해 Miner의 손상식을 이용하였다. 갑판에서 가능한 여러 연결부 형태에 대해 그 피뢰신뢰성을 추정하였고 또한 굽힘에 의한 파괴와 피로에 의한 파괴를 동시에 고혀하는 일종의 Series System에 대한 신뢰성을 평가를 하였다.

  • PDF

형상비 2.5 RC 교각의 곡률분석평가 (Evaluation of Curvature Analysis at RC Bridge Piers in an aspect ratio of 2.5)

  • 박창규;정영수;이은희;김영섭
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.263-270
    • /
    • 2003
  • Before the implementation of the 1992 seismic design provisions in Korea, longitudinal steels of RC bridge piers were practically lap-spliced in the plastic hinge region. Experimental investigation was made to evaluate the seismic performance of RC bridge pier specimens in a flexure/shear mode. Six circular test specimens in an aspect ratio of 2.5 (600mm in diameter) were made with test parameters confinement ratio, lap splices, and retrofit FRP materials. They were damaged under a series of artificial earthquakes with 0.22g PGA, being compatible in Korean peninsula, through the pseudo-dynamic test. Probable damages were assessed by the Park and Ang damage index. Approximate 0.1 and 0.3 damage indices were obtained for RC specimens without lap splice and with lap splice, respectively. Directly after the pseudo-dynamic test, damaged test columns were laterally actuated under inelastic reversal cyclic loadings simultaneously under a constant axial load. Through curvature measurements, residual seismic performance was evaluated for test specimens. Test results show that RC pier specimens with lap-spliced appeared to fail at low ductility, but significant improvement was obtained for the ductility of these specimens if externally wrapped with FRP.

  • PDF

Analysis of rectangular hybrid steel-GFRP reinforced concrete beam columns

  • El-Heloua, Rafic G.;Aboutaha, Riyad S.
    • Computers and Concrete
    • /
    • 제16권2호
    • /
    • pp.245-260
    • /
    • 2015
  • In this study, nominal moment-axial load interaction diagrams, moment-curvature relationships, and ductility of rectangular hybrid beam-column concrete sections are analyzed using the modified Hognestad concrete model. The hybrid columns are primarily reinforced with steel bars with additional Glass Fiber Reinforced Polymer (GFRP) control bars. Parameters investigated include amount, pattern, location, and material properties of concrete, steel, and GFRP. The study was implemented using a user defined comprehensive $MATLAB^{(R)}$ simulation model to find an efficient hybrid section design maximizing strength and ductility. Generating lower bond stresses than steel bars at the concrete interface, auxiliary GFRP bars minimize damage in the concrete core of beam-column sections. Their usage prevents excessive yielding of the core longitudinal bars during frequent moderate cyclic deformations, which leads to significant damage in the foundations of bridges or beam-column spliced sections where repair is difficult and expensive. Analytical results from this study shows that hybrid steel-GFRP composite concrete sections where GFRP is used as auxiliary bars show adequate ductility with a significant increase in strength. Results also compare different design parameters reaching a number of design recommendations for the proposed hybrid section.