• 제목/요약/키워드: long-term operation test

검색결과 174건 처리시간 0.03초

생체흡수성 고정장치를 이용한 상악골 이동술 후 장기간 결과 (STABILITY OF MAXILLARY POSITION AFTER LEFORT I OSTEOTOMY USING BIODEGRADABLE PLATES AND SCREWS)

  • 김봉철;정영수
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제33권5호
    • /
    • pp.499-503
    • /
    • 2007
  • Introduction: In orthognathic surgery, internal fixation has been usually done with titanium plates and screws. Recently, Biodegradable plates and screws have been frequently used but the reports of long term results of postoperative stability are rare, especially after maxillary reposition in orthognathic surgery. Objective: In order to clarify the clinical utility of self-reinforced bioresorbable poly-70L/30DL-Lactide miniplates & screws in maxillary fixation after LeFort I osteotomy, this study examined the postsurgical changes in maxilla and complications of biodegradable plates and screws. Study design: Nineteen patients who had undergone maxillary internal fixation using biodegradable plates and screws were evaluated radiographically and clinically. A comparison study of the changes in maxilla position after surgery in all 19 patients was performed with 1-week, 1-month, 3-months, 6-months and/or 1-year postoperative lateral cephalograms by tracing. Complication of the biodegradable plates and screws was evaluated by follow-up roentgenograms and clinical observation. And one-way ANOVA test was used for statistical analysis. Results: The position of the maxillary bone was stable after surgery and was not changed significantly from 1 week to 1 year after operation. And we could not find any complication of biodegradable plates and screws. Conclusions: Internal fixation of the maxilla after LeFort I osteotomy using self-reinforced biodegradable plates and screws is a reliable method for maintaining postoperative position of the maxilla after LeFort I osteotomy.

이동성을 구비한 능동위상배열안테나 근접전계 스캐너 설계 및 성능 검증 (Design and Performance Verification of Active Phased Array Antenna Near-Field Scanner with Mobility)

  • 유우성;김성균;권용욱;정기용;장헌순
    • 전기전자학회논문지
    • /
    • 제21권1호
    • /
    • pp.30-38
    • /
    • 2017
  • 사이트에 설치되어 운용 중인 능동위상배열레이다가 외부의 충격 또는 장기간 운용에 따른 성능열화가 의심될 경우, 위상배열안테나의 이상여부를 확인해야 한다. 하지만, 위상배열안테나를 측정하기 위해서는 무반향성 챔버에서 근접전계 시험이 수행되어야 하므로, 레이다 장치의 분해 및 운송을 위해 많은 시간과 비용이 투입되어야 하고 레이다 시스템의 운용 가용도가 나빠지게 된다. 따라서, 본 논문에서는 사이트에서 위상배열안테나의 이상여부를 확인할 수 있도록 이동성을 구비한 능동위상배열안테나 근접전계 스캐너를 제안하고, 무반향성 챔버에서 측정한 데이터와 비교하여 크기 ${\pm}0.5dB$와 위상 ${\pm}1.5^{\circ}$ 오차수준으로 측정유효성을 검증하였다.

KOGAS DME 공정의 실증 시험을 통한 최적화 기술개발 (Optimization of KOGAS DME Process From Demonstration Long-Term Test)

  • 정종태;조원준;백영순;이창하
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.559-571
    • /
    • 2012
  • Dimethyl ether (DME) is a new clean fuel as an environmentally-benign energy resource. DME can be manufactured from various energy sources including natural gas, coal, and biomass. In addition to its environmentally friendly properties, DME has similar characteristics to those of LPG. The aim of this article is to represent the development of new DME process with KOGAS's own technologies. KOGAS has investigated and developed new innovative DME synthesis process from synthesis gas in gaseous phase fixed bed reactor. DME has been traditionally produced by the dehydration of methanol which is produced from syngas, a product of natural gas reforming. This traditional process is thus called the two-step method of preparing DME. However, DME can also be manufactured directly from syngas (single-step). The single-step method needs only one reactor for the synthesis of DME, instead of two for the two-step process. It can also alleviate the thermodynamic limitations associated with the synthesis of methanol, by converting the produced methanol into DME, thereby potentially enhancing the overall conversion of syngas into DME. KOGAS had launched the 10 ton/day DME demonstration plant project in 2004 at Incheon KOGAS LNG terminal. In the mid of 2008, KOGAS had finished the construction of this plant and has successively finished the demonstration plant operation. And since 2008, we have established the basic design of commercial plant which can produce 3,000 ton/day DME.

콘크리트용 고성능 수축저감제 개발에 대한 기초적 특성 (Fundamental Properties on the Development of High Performance Shrinkage Reducing Agent for Concrete)

  • 박종필;정용욱
    • 한국산학기술학회논문지
    • /
    • 제16권6호
    • /
    • pp.4298-4307
    • /
    • 2015
  • 최근 콘크리트 구조물의 내구성 저하에 따른 성능저하로 유지 보수나 보강등에 상당한 비용이 증가함에 따라 콘크리트의 고유 특성인 균열 저감에 대한 연구가 필요한 실정이다. 특히 장기간 운영에 따른 지하 전력구의 노후화로 유지 보수에 어려움이 상존함에 따라 전력구 설계단계에서 균열을 획기적으로 저감할 수 있는 저수축 콘크리트용 수축저감제 기술 개발이 필요하다. 본 연구는 콘크리트 구조물의 내구성 저하에 따른 균열을 방지하고자 균열을 획기적으로 저감할 수 있는 저수축 콘크리트를 개발하기 위한 것으로 수축저감 물질을 선정하고 모르타르 및 콘크리트 특성을 검토한 결과 클리콜계의 경우 압축강도 특성 및 건조수축 길이변화 실험결과에서 우수한 것으로 나타나 수축저감제로서의 가능성을 확인하였다. 추후 수축저감제의 범용적인 적용성 검토를 위하여 수축저감제의 사용량 및 사용재료 변화 등에 대한 다양한 재료변수 요인 검토를 통하여 수축저감제의 성능 검토가 필요할 것으로 사료된다.

구조물의 안전성 모니터링을 위한 통계/확률기반 적응형 임계치 설정 알고리즘 개발 (Development of Statistical/Probabilistic-Based Adaptive Thresholding Algorithm for Monitoring the Safety of the Structure)

  • 김태헌;박기태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.1-8
    • /
    • 2016
  • 최근의 건축물은 복합적인 기능과 형태를 보이고 있으며, 크기가 거대해짐에 따라 구조물 건전성 감시(Structural Health Monitoring)기술의 수요 또한 증가하고 있다. 구조물마다 고유한 동특성을 가지고 있으며, 다양한 외력의 영향을 받기 때문에 구조물의 건전성을 평가하는 다양한 방법들이 연구되고 있다. 전문가에 의지하여 접근 가능한 지점에 대한 육안 검사 및 비파괴 검사를 벗어나 사각지대가 없는 온라인 계측 시스템의 구비와 함께 자동으로 위험요소를 검출하는 시스템이 요구되고 있다. 본 연구에서는 비선형적인 구조물의 응답을 고려하기 위해 관리도 기법, 평균제곱근편차, 일반 극치 분포 등과 같은 통계적 기법을 이용하여 이상거동을 판별에 활용할 수 있는 신호 특징 추출과 적응형 임계치 설정 알고리즘을 제안하였으며, 강제진동 실험과 실제 운용중에 있는 구조물의 지진 계측 시스템의 가속도 응답을 이용하여 성능을 검증하였다.

한국형 포장가속시험시설의 개발현황 (Development Status of Korea Accelerated Loading and Environment Simulator (KALES))

  • 양성철;유태석;엄주용
    • 한국도로학회논문집
    • /
    • 제2권2호
    • /
    • pp.139-148
    • /
    • 2000
  • 외국의 포장가속시험기는 대부분 아스팔트포장의 시험을 주된 목적으로 개발되었다. 그러나, 국내의 고속도로는 콘크리트포장과 아스팔트포장이 거의 같은 연장을 유지하고 있는 실정으로 콘크리트포장의 활용이 예상되어 콘크리트 포장의 시험을 위한 독자적인 포장가속시험시설의 개발이 요구되고 있다. 따라서 한국의 실정에 알맞은 콘크리트/아스팔트포장 '시험용 포장가속 시험시설'을 개발하기 위하여 1997년부터 1999년 동안의 3년간 연구를 수행하였다. 1차 연도에서는 포장가속시험시설을 제작하는데 필요한 기본적인 사양과 기본 시스템 설계에 관한 기초연구가 이루어 졌고, 2$\sim$3차 년도에는 KALES의 전체구조, 하중작용, 현가장치 및 구동장치 등에 대한 상세설계를 수행하였다. 실모델을 제작하기 전단계로 모형시험기를 만들어 시험을 수행하여 작동성 및 하중분배기구 등을 검토하였다. 피로해석 검토결과 제안된 KALES 시스템은 내구성이 있으며 실제차량을 잘 모사할 수 있는 시험기로 판명되었다.

  • PDF

삼차신경통에 대한 미세혈관감압술의 효과 (The Efficacy of Microvascular Decompression for Trigeminal Neuralgia)

  • 김성훈;최창화
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권5호
    • /
    • pp.357-363
    • /
    • 2005
  • Objective: The microvascular decompression(MVD) for trigeminal neuralgia(TN) is known as an effective surgical technique. But the failed MVD cases have been reported in long term follow-up studies. This study is to evaluate the efficacy of MVD through our operative techniques, offending vessels in operative field, failed cases with the review of the literatures. Methods: We analyzed total 63 cases of TN which underwent MVD from 1955 to 2003 according to characters of pain, operative findings, operative results related to causative vessel compression and operative method, progonotic factor. Statistical analysis was performed using paired t-test with SPSS Ver 11.0. Results: In TN, the most common offending vessel was superior cerebellar artery(45.0%). In compression group of nerve root by offending vessel, the cure rate was 91.7%. However, the cure rate of the contact group was 64.7% and the cure rate of the negative group was 37.5%. There was no statistical significance between the degree of compression by vessel and the operative result(p=0.076). In 51 cases with MVD only, the cure rate was 84.3% and in 3 cases with PSR only, 42.8% and in 2 cases with PSR(partial sensory rhizotomy) with MVD, 50.0%. TN recurred in 7 cases within the follow-up period and reoperations(PSR) were added in 2 cases of them. Conclusion: This study shows that MVD provided a high rate of success with a minor risk of complications, which has been regarded as the most safe and effective procedure for trigeminal neuralgia. Additional MVD in recurred TN by severe adhesion of teflon showed poor outcome. But, revisional operation(PSR) in recurred TN showed relatively good outcome. PSR should be considered for treatment of recurrent TN after MVD.

장기 저수지운영률 도출을 위한 메타휴리스틱 기법의 비교 (Comparision of metaheuristic methods for generating long-term reservoir operation rule)

  • 강신욱;이상호;김현식
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2011년도 학술발표회
    • /
    • pp.226-226
    • /
    • 2011
  • 최적 저수지운영을 위한 운영률 도출이나 강우-유출 및 수질 모형의 매개변수 추정 문제처럼 비선형적이고 추정해야할 변수의 수가 많은 경우, 수학적으로 모형화하기에 너무 복잡해서 선형계획법, 비선형계획법, 동적계획법 등을 사용하여 최적해를 구할 수 없는 경우도 있다. 이러한 문제에 대해서는 구조적 진화를 통해 최적해를 구하는 방법들이 사용된다. 일반적으로 미지수의 개수가 많아지면 전역최적해를 찾기가 어려워진다. 전역최적해를 찾는 여러 가지 방법들이 수자원 분야에서는 강우-유출모형의 매개변수를 추정하는데 많이 사용되고 있으며, 특히 유전자 알고리즘, SCE-UA 알고리즘 등 전역최적해를 찾는 메타휴리스틱 방법이 많이 사용되고 있다. 전역최적화 방법을 개발하는 연구자들은 최적화방법의 성능을 평가하기 위해 다양한 검사함수(test function)를 만들어 성능을 평가하고 있다. 본 연구에 사용한 검사함수는 Mishra의 연구(2006a, 2006b)에서 사용한 중요하고 복잡한 검사함수이다. 유전자 알고리즘, SCE-UA 알고리즘, DDS 알고리즘을 검사함수 중 전역해를 찾기 어려운 2 차원 함수 2 가지, 다차원 함수 4 가지 함수에 적용하여 각각의 탐색 성능을 평가하였다. 2차원 함수인 Bukin 함수에 대해서는 모든 최적화 방법이 전역최적해를 찾을 수 없었지만, 유전자 알고리즘이 가장 전역최적해에 가까웠고 다음으로 DDS 알고리즘 순서였다. 지역수렴 영역이 많을 것으로 판단되는 10, 30, 50 차원 Michalewicz 함수에 대해서는 DDS 알고리즘으로 구한 최적해가 전역최적해와 매우 근접하였고 다음으로 SCE-UA 알고리즘, 유전자 알고리즘 순이었다. 지역수렴 영역이 상대적으로 다른 함수보다 넓은 10 차원 Schwefel 함수에 대해서는 DDS 알고리즘으로 구한 최적해가 전역최적해와 거의 근접하였고 유전자 알고리즘과 SCE-UA 알고리즘은 매우 큰 편차를 보였다. 40, 80 차원 Schwefel 함수에 대해서는 3 가지 알고리즘 모두 전역최적해와 편차를 보였지만 DDS 알고리즘에 의한 최적해와 다른 두 알고리즘에 의한 최적해는 1 오더(order) 정도의 차이가 났다. 지역수렴 영역이 큰 Michalewicz 함수와 Schwefel 함수에 대한 결과는 매우 흡사한 결과이다. 이상과 같은 결과로, 유전자 알고리즘은 매개변수의 수가 적을 경우 우수한 탐색성능을 가졌으며, SCE-UA 알고리즘은 Griewank, Rastrigin 함수와 같은 형태인 경우 우수한 성능을 보였다. DDS 알고리즘은 전체적으로 우수한 탐색 능력을 가진 것으로 판단된다. 그러므로 수위구간 영역별 저수지운영률 도출을 위한 적절한 최적화방법으로 DDS 알고리즘을 선정하였다.

  • PDF

암반 대수층에서 개방형 지열 시스템의 개발 및 적용 (Development of a Groundwater Source Heat Pump in a Fractured Rock Aquifer)

  • 심병완;김성균;최한나;이수형;하규철;김용철
    • 신재생에너지
    • /
    • 제17권3호
    • /
    • pp.32-41
    • /
    • 2021
  • A groundwater source heat pump (GWHP) was developed in this study by adapting a borehole heat exchanger with closed-loop and open-loop systems in a new building. In the pilot test building, the air-conditioning on the second floor was designed to employ a closed-loop system and that on the third floor had an open-loop system. The GWHP design is based on the feasibility of groundwater resources at the installation site. For the hydrogeological survey of the study site, pumping and injection tests were conducted, and the feasibility of GWHP installation was evaluated based on the air-conditioning load demand of the building. The site was found to be satisfactory for the design capacity of the thermal load and water quality. In addition, the effect of groundwater movement on the performance of the closed-loop system was tested under three different operational scenarios of groundwater pumping. The performance of the system was sustainable with groundwater flow but declined without appropriate groundwater flow. From long-term observations of the operation, the aquifer temperature change was less than 2℃ at the observation well and 5℃ at the injection well with respect to the initial groundwater temperature. This pilot study is expected to be of guidance for developing GWHPs at fractured rock aquifers.

국산 산소 농축기의 개발 및 동물실험 (Development and Animal Tests of Prototype Oxygen Concentrator)

  • 변정욱;성숙환;이태수
    • Journal of Chest Surgery
    • /
    • 제31권7호
    • /
    • pp.643-649
    • /
    • 1998
  • 장기간 산소 호흡치료가 필요한 만성호흡부전증 환자에서 가정내 산소 농축기의 사용은 이미 보편화 되어있고 적응 및 사용빈도도 증가추세에 있다. 본 연구팀이 최근 개발한 국산 산소농축기의 성능검사와 보완점을 찾기위해 이미 시판되어 사용중인 외국산 산소농축기(FOR LIFE\ulcorner, Air Sep Corp. USA)와 비교 분석하여 효용성 및 안정성을 검증하고자 하였다. 기계적 성능 시험으로는 제작한 시제품과 외굿산 산소농축기를 4시간 연속 작동후 발생되는 산소농도를 측정하였으며, 동물실험은 잡견 16마리를 각 군당 8마리씩 A군, B군으로 나누어 A군은 외국산 산소농축기로, B군은 자체 개발한 산소농축기로 분당 5 리터의 산소를 공급하여 기본활력증후, 동맥혈 가스분석 및 혈액 화학 검사 등을 검사하였다. 4시간 연속 작동후 발생하는 산소 농도는 외산 98$\pm$3%, 국산 91$\pm$1 %로 외산이 우수하였다. 동물실험에서 산소 공급후 1, 2, 3, 4시간에 산소마스크 주입구에서 측정한 산소 농도는 A군에서 각각 70.6$\pm$2.5%, 67.1$\pm$2.9%, 68.2$\pm$2.6%, 64.9$\pm$3.9%, B군에서는 65.1$\pm$4.8%, 65.2$\pm$3.6%, 68.7$\pm$4.3%, 66.0$\pm$5.0%로 두 군간에 유의한 차이를 보이지 않았으며 (반복측정 분산분석 p=0.70), 산소투여 전 및 투여 후 1, 2, 3, 4 시간의 동맥혈 산소분압은 A군에서 각각 87.2$\pm$2.5 mmHg, 347.4$\pm$29.3 mmHg, 353.4$\pm$21.2 mmHg, 343.0$\pm$28.8 mmHg, 321.6$\pm$24.4 mmHg, B군에서 각각 102.5$\pm$9.6 mmHg, 300.3$\pm$17.1 mmHg, 321.6$\pm$23.7 mmHg, 303.4$\pm$27.4 mmHg, 273.5$\pm$25.9 mmHg로 비록 통계적 유의성은 없었으나(p=0.24) 외산 산소 농축기를 사용한 군에서 동맥혈 산소분압이 다소 높은 경향을 보였다. 이상으로부터 본연구팀이 현재 개발중인 국산 산소 농축기의 시제품의 성능을 시험한 결과 외산 산소 농축기와 비교하여 비교적 만족스러운 성능을 보였으나 소음, 내구성 등의 개선할 부분이 지적되었다.

  • PDF