• Title/Summary/Keyword: long electrode

Search Result 415, Processing Time 0.026 seconds

Electrochemical oxidation of sodium dodecylbenzenesulfonate in Pt anodes with Y2O3 particles

  • Jung-Hoon Choi;Byeonggwan Lee;Ki-Rak Lee;Hyun Woo Kang;Hyeon Jin Eom;Seong-Sik Shin;Ga-Yeong Kim;Geun-Il Park;Hwan-Seo Park
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4441-4448
    • /
    • 2022
  • The electrochemical oxidation process has been widely studied in the field of wastewater treatment for the decomposition of organic materials through oxidation using ·OH generated on the anode. Pt anode electrodes with high durability and long-term operability have a low oxygen evolution potential, making them unsuitable for electrochemical oxidation processes. Therefore, to apply Pt electrodes that are suitable for long-term operation and large-scale processes, it is necessary to develop a new method for improving the decomposition rate of organic materials. This study introduces a method to improve the decomposition rate of organic materials when using a Pt anode electrode in the electrochemical oxidation process for the treatment of organic decontamination liquid waste. Electrochemical decomposition tests were performed using sodium dodecylbenzenesulfonate (SDBS) as a representative organic material and a Pt mesh as the anode electrode. Y2O3 particles were introduced into the electrolytic cell to improve the decomposition rate. The decomposition rate significantly improved from 21% to 99%, and the current efficiency also improved. These results can be applied to the electrochemical oxidation process without additional system modification to enhance the decomposition rate and current efficiency.

Evaluation of Long Term Operation of Cross-flow Molten Carbonate Fuel Cell Stack (교차류형 100W급 용융탄산염 연료전지 스택 장기운전평가)

  • Lim, H.C.;Seol, J.H.;Ryu, C.S.;Lee, C.W.;Hong, S.A.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.6 no.2
    • /
    • pp.53-63
    • /
    • 1995
  • A 100kW class stack consisting of 10 molten carbonate fuel cells has been fabricated. Internally manifold stack has been tested for endurance. Each cell in the stack had an electrode area of $100cm^2$ and reactant gases were distributed in each cells in a cross-flow configuration. Initial and long term operation performance of the stack was investgated as a function of gas utilization using a specially designed small scale stack test facility. It was possible to have a stack with an output of more than 100W using an anode gas of 72% $H_2/18%$ $CO_2/10%H_2O$ and cathode gas of 33% $O_2/67%$ $CO_2$ and 70% Air 30% $CO_2$. The output and voltage of the stack at a current 15A($150mA/cm^2$) and gas utilization of 0.4 showed 125.8W and 8.39V respectively by elapsed time of 310 hours operation. In long term operation characteristics, the voltage drop of 52.4mV/1000hour was observed after more than 1,840 hours operation. Among the voltage drop, the OCV loss was highest than other voltage loss such as internal resistance and electrode polarization. Non uniformity of 2voltages and degradation of cell voltage in the stack was observed in according to changing the utilization rate after a long term operation. Further work for increasing the performance prolonging the life of the stack are required.

  • PDF

A Study on Long-time Electrical Treeing Deterioration Properties According to High Frequency Voltage of Epoxy Resin (에폭시수지의 고전압 전원주파수 변화에 따른 장시간 전기적 트리잉 열화 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1571-1577
    • /
    • 2013
  • Electrical tree structure is one of the most important influencing factors for electrical treeing characteristics in polymers. In this paper, we focused on the structure characteristics of electrical treeing in epoxy resins (original) insulation under different high-frequency voltages (60, 500, 1000Hz). Effects of voltage frequency on the ac electrical treeing phenomena in an epoxy resins were carried out in needle-plate electrode arrangement. To measure the treeing initiation and propagation, and the breakdown rate, constant AC of 10 kV with three different voltage frequencies (60, 500 and 1,000 Hz) was applied to the specimen in needle-plate electrode specimen at $30^{\circ}C$ of insulating oil bath. At 60 Hz, the treeing initiation time was 360 min and the propagation rate was $6.85{\times}10^{-4}mm/min$, and the morphology was dense branch type. As the voltage frequency increased, the treeing initiation time decreased and the propagation rate increased. At 1,000 Hz, the treeing initiation time was 0 min and the propagation rate was $7.81{\times}10^{-2}mm/min$, and the morphology was dense bush type.

Porous Electrodes with Lower Impedance for Vanadium Redox Flow Batteries

  • Park, Su Mi;Kim, Haekyoung
    • Korean Chemical Engineering Research
    • /
    • v.53 no.5
    • /
    • pp.638-645
    • /
    • 2015
  • Vanadium redox flow batteries (VRFBs) have been investigated for their potential utility as large energy storage systems due to their advantageous performances in terms of long cycle life, high energy efficiency, low cost, and flexible design. Carbon materials are typically used as electrodes in redox reactions and as a liquid electrolyte support. The activities, surface areas, and surface morphologies of porous carbon materials must be optimized to increase the redox flow battery performance. Here, to reduce the resistance in VRFBs, surface-modified carbon felt electrodes were fabricated, and their structural, morphological, and chemical properties were characterized. The surface-modified carbon felt electrode improved the cycling energy efficiencies in the VRFBs, from 65% to 73%, due to the improved wettability with electrolyte. From the results of impedances analysis with proposed fitting model, the electrolyte-coupled polarization in VRFB dramatically decreased upon modification of carbon felt electrode surface. It is also demonstrated that the compressibility of carbon felt electrodes was important to the VRFB polarization, which are concerned with mass transfer polarization. The impedance analysis will be helpful for obtaining better and longer-lived VRFB performances.

A Study on Development of 2MHz High-frequency Rehabilitation Treatment Device for Deep Part (심부투열용 2MHz 고주파 재활치료기의 개발에 관한 연구)

  • Ahn, Jong-Bok;Kim, Sang-Beom;Won, Cheol-Hee;Kim, Sung-Hoon;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.117-122
    • /
    • 2017
  • Due to the aging and obesity population in Korea, degenerative musculoskeletal diseases and people suffering from degenerative arthritis are increasing day by day. So, it is necessary to develop rehabilitation treatment device. Conventional high-frequency treatment devices have disadvantages in that therapeutic range is narrow, cost is high, image is adversely affected, treatment time is long, and failure rate is high. This paper proposes a customized therapy device that is stable and effective in reducing treatment time and output to target body part using 2MHz switching frequency, feedback control technique, and joint insulation flexible multipolar electrode. The device can be a new concept high-frequency stimulator to accommodate the advantages of CET and RET.

An 0.4nm Resolution Encoder-like Capacitive Displacement Sensor (0.4nm 해상도의 엔코더 타입 전기용량형 변위센서)

  • Kang, Dae-Sil;Kim, Moo-Jin;Moon, Won-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1450-1454
    • /
    • 2007
  • A Contact-type Linear Encoder-like Capacitive Displacement Sensor (CLECDiS) has been developed to measure displacements at high accuracy within a long measurement range. In this paper, we have worked on improving the performance and reliability of the sensor. The performance increase can be done by introducing the smaller electrode patterns of $4{\mu}m$ width. In order to improve the reliability of the sensor we have changed the electrode layers from chrome-gold to chrome-gold-chrome and re-design its supporting structure. The newly-designed sensor is fabricated and tested to show that its sensitivity is $35pF/{\mu}m$, which implies that its resolution may be 0.36nm if SNR (Signal-to-Noise-Ratio) is 80.1dB. It is about ten times of that $(3.14pF/{\mu}m)$ of its previous version with 10${\mu}m$ electrodes. The total measurement range remains the same as the previous one; 15mm. The calibration experiments show its improved performance and reliability.

  • PDF

Corona Cage Simulation on Environmental Characteristics Caused by the Ion flow of Candidated Conductor Bundles for HVDC Overhead Transmission (초고압 직류 가공송전 후보 도체방식의 이온류 환경특성 코로나 케이지 모의시험)

  • Ju, Mun-No;Yang, Kwang-Ho;Lee, Dong-Il;Shin, Koo-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1791-1795
    • /
    • 2007
  • Small ions generated at conductor corona sources remain in the atmosphere until they recombine with ions of opposite polarity, attach to aerosols, or make contact with an object. Ion current density is major factor to design conductor configuration of DC overhead transmission line. Several techniques have been used to measure the ion current of HVDC overhead transmission line. In this study, the ion current density was measured by a plate electrode made of a metal flat board at DC corona cage. The sensitivity of the plate electrode is $0.156uA/m^2/V$. To obtain an useful database on corona discharge, it is necessary to do corona test on several kinds of conductor bundles. Therefore, a number of experiments were conducted on several kinds of conductor bundles. To reliably analyze ion effects, corona cage test data were obtained over a long period of time under various weather conditions and expressed as a statistical distribution. Ion current density distribution in foul weather shows a significant increase in levels over the corresponding fair weather. Based on this results, we evaluated the environmental characteristic caused by ion flow of three candidated conductor bundles.

A Study on the Development of Zr-Ti-Mn-V-Ni Hydrogen Storage Alloy for Ni-MH Rechargeable Battery (Ni-MH 2차 전지용 고용량, 고성능 Zr-Ti-Mn-V-Ni계 수소저장합금의 개발에 관한 연구)

  • Kim, Dong-Myung;Jung, Jae-Han;Lee, Sang-Min;Lee, Jai-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.2
    • /
    • pp.137-145
    • /
    • 1996
  • The Zr-based $AB_2$ type Laves phase hydrogen storage alloys have some promising properties, long cycle life, high discharge capacity, as electrode materials in reversible metal hydride batteries. However, when these alloys are used as negative electrode for battery, there is a problem that their rate capabilities are worse than those of commercialized $AB_5$ type hydrogen storage alloys. In this work, we tried to develop the Zr-based $AB_2$ type Laves phase hydrogen storage alloys which have high capacity and, especially, high rate capability.

  • PDF

The effect of Ni content on the discharge characteristics of Zr-V-Mn-Ni hydrogen storage alloy electrode (Zr-V-Mn-Ni 수소저장합금전극의 방전특성에 미치는 Ni 양의 효과에 관한 연구)

  • Lee, Sang-Min;Kim, Dong-Myung;Jung, Jae-Han;Lee, Jai-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.8 no.1
    • /
    • pp.11-21
    • /
    • 1997
  • $ZrV_{0.7}Mn_{0.5}Ni_{1.2}$ alloy is attractive for anode material in Ni/MH secondary battery because of its large hydrogen storage capacity in gas-solid reaction and long cycling durability in KOH electrolyte. In this work, in order to further improve the discharge performance of this alloy electrode, the alloy was annealed by optimal condition which is for 12 hours at $1000^{\circ}C$. The alloy annealed under optimal condition had higher rate capability and discharge capacity than as-cast one. The microstructure of the as-cast and annealed alloy was investigated by scanning electron microscopy and energy dispersive spectroscopy. Ni content in the matrix was increased, being this homogenized after annealing. Additionally, The measurement of the surface area by B.E.T. analysis showed that there was little difference as-cast and annealed alloy. Therefore, improvement in the rate capability of the annealed alloy is due to increase of Ni content in the matrix.

  • PDF

FE and ANN model of ECS to simulate the pipelines suffer from internal corrosion

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.3
    • /
    • pp.297-314
    • /
    • 2016
  • As the study of internal corrosion of pipeline need a large number of experiments as well as long time, so there is a need for new computational technique to expand the spectrum of the results and to save time. The present work represents a new non-destructive evaluation (NDE) technique for detecting the internal corrosion inside pipeline by evaluating the dielectric properties of steel pipe at room temperature by using electrical capacitance sensor (ECS), then predict the effect of pipeline environment temperature (${\theta}$) on the corrosion rates by designing an efficient artificial neural network (ANN) architecture. ECS consists of number of electrodes mounted on the outer surface of pipeline, the sensor shape, electrode configuration, and the number of electrodes that comprise three key elements of two dimensional capacitance sensors are illustrated. The variation in the dielectric signatures was employed to design electrical capacitance sensor (ECS) with high sensitivity to detect such defects. The rules of 24-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. A feed-forward neural network (FFNN) structure are applied, trained and tested to predict the finite element (FE) results of corrosion rates under room temperature, and then used the trained FFNN to predict corrosion rates at different temperature using MATLAB neural network toolbox. The FE results are in excellent agreement with an FFNN results, thus validating the accuracy and reliability of the proposed technique and leads to better understanding of the corrosion mechanism under different pipeline environmental temperature.