• Title/Summary/Keyword: logic conduction

Search Result 8, Processing Time 0.02 seconds

The Properties of Electrical Conduction and Photoconduction in Polyphenylene Sulfide(PPS) by Uniaxial Elongation (일축연신에 따른 Polyphenylene sulfide(PPS)의 전기전도 및 광전도 특성)

  • 이운용;장동욱;강성화;임기조;류부형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.223-226
    • /
    • 1998
  • In this paper, we have investigated how morphology and electrical properties in Polyphenylene sulfide(PPS) are changed by uniaxial elongation. XRD pattern shows that interplanar distance and crystallinities are decreased by increasing elongation ratio. Electrical conduction mechanism of PPS is explained as schottky emission from analysis of electrical current. The electrical current is decreased by increasing elongation ratio. The conductivity is changed remarkably above the glass transition temperature around $(82^{\circ}C)$. The band gap of PPS is evaluated as 3.9-4(eV) from the results of photoconductivity. Increarnent of elongation ratio gives us some information about deep trap formation from photocurrent.

  • PDF

Stabilizing Control of DC/DC Buck Converters with Constant Power Loads in Continuous Conduction and Discontinuous Conduction Modes Using Digital Power Alignment Technique

  • Khaligh Alireza;Emadi Ali
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.63-72
    • /
    • 2006
  • The purpose of this raper is to address the negative impedance instability in DC/DC converters. We present the negative impedance instability of PWM DC/DC converters loaded by constant power loads (CPLs). An approach to design digital controllers for DC/DC converters Is presented. The proposed method, called Power Alignment control technique, is applied to DC/DC step-down choppers operating in continuous conduction or discontinuous conduction modes with CPLs. This approach uses two predefined state variables instead of conventional pulse width modulation (PWM) to regulate the output voltage. A comparator compares actual output voltage with the reference and then switches between the appropriate states. It needs few logic gates and comparators to be implemented thus, making it extremely simple and easy to develop using a low-cost application specific integrated circuit (ASIC) for converters with CPLs. Furthermore, stability of the proposed controllers using the small signal analysis as well as the second theorem of Lyapunov is verified. Finally, simulation and analytical results are presented to describe and verify the proposed technique.

Fuzzy Control for Performance Improvement of DC Motor Drive System (직류전동기 드라이브 시스템의 성능개선을 위한 퍼지제어)

  • 정동화
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.1
    • /
    • pp.55-65
    • /
    • 1999
  • Fuzzy logic fuzzy set theory is recently getting increasing emphasis in process control applications. This paper describes application of fuzzy logic in a speed control system that uses a phase controlled bridge converter and a separately excited dc motor. The fuzzy control is used to linearize the transfer characteristics of the converter in discontinuous conduction mod occurring at light load and high speed. The fuzzy control is then extended to the current and speed control loops replacing the conventional PI control method. The control algorithms have been developed in detail and verified by simulation of a DC motor(DM) drive system. The simulation result indicates the superiority of fuzzy control over the conventional control methods. Fuzzy logic seems to have a lot of promise in the applications of power electronics.

  • PDF

Design and Implementation of PIC/FLC plus SMC for Positive Output Elementary Super Lift Luo Converter working in Discontinuous Conduction Mode

  • Muthukaruppasamy, S.;Abudhahir, A.;Saravanan, A. Gnana;Gnanavadivel, J.;Duraipandy, P.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1886-1900
    • /
    • 2018
  • This paper proposes a confronting feedback control structure and controllers for positive output elementary super lift Luo converters (POESLLCs) working in discontinuous conduction mode (DCM). The POESLLC offers the merits like high voltage transfer gain, good efficiency, and minimized coil current and capacitor voltage ripples. The POESLLC working in DCM holds the value of not having right half pole zero (RHPZ) in their control to output transfer function unlike continuous conduction mode (CCM). Also the DCM bestows superlative dynamic response, eliminates the reverse recovery troubles of diode and retains the stability. The proposed control structure involves two controllers respectively to control the voltage (outer) loop and the current (inner) loop to confront the time-varying ON/OFF characteristics of variable structured systems (VSSs) like POESLLC. This study involves two different combination of feedback controllers viz. the proportional integral controller (PIC) plus sliding mode controller (SMC) and the fuzzy logic controller (FLC) plus SMC. The state space averaging modeling of POESLLC in DCM is reviewed first, then design of PIC, FLC and SMC are detailed. The performance of developed controller combinations is studied at different working states of the POESLLC system by MATLAB-Simulink implementation. Further the experimental corroboration is done through implementation of the developed controllers in PIC 16F877A processor. The prototype uses IRF250 MOSFET, IR2110 driver and UF5408 diodes. The results reassured the proficiency of designed FLC plus SMC combination over its counterpart PIC plus SMC.

Critical Conduction Mode BOOST Type Solar Array Regulator (임계모드 부스트형 태양전력 조절기)

  • Yang, JeongHwan;Ryu, SangBurm;Yun, SeokTeak
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.3
    • /
    • pp.86-90
    • /
    • 2014
  • A DC-DC Converter operates in CCM(Continuous Coundcution Mode), DCM(Discontinuous Conduction Mode), CRM(Critical Conduction Mode). The CRM is boundary between CCM and DCM. If a DC-DC converter is designed to operate in CRM, its inductor volume can decrease and power loss which caused by switch and diode can decrease. In this paper, the DC-DC converter which operates in CRM is applied to a solar array regulator(SAR) for the satellite. The switching frequency of the CRM boost SAR changes according to input and output condition. The switching frequency limit logic is applied to limit the maximum switching frequency. Meanwhile, the small signal transfer function of the CRM boost SAR is simple, so the controller design is also simple. In this paper, the small signal transfer function from control reference to solar array voltage is induced. And the voltage controller is designed based on the small signal transfer function. Finally, the CRM boost SAR is verified by simulation.

A Study on the LRE Thrust Chamber Regenerative Cooling Design (액체로켓엔진 추력실의 재생냉각 기관 설계)

  • Kim, Ji-Hoon;Park, Hee-Ho;Kim, Yoo;Hwang, Soo-Kwon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.4
    • /
    • pp.25-35
    • /
    • 2002
  • A calculation procedure for designing LRE regenerative cooling system is introduced. In LRE thrust chamber, heat is transfered from the hot gas to the wall by convection and radiation, then conduction through the wall and finally convection to the liquid coolant. A cooling channel is designed on the basis of heat transfer rate calculated by using criterial method and integral method. The result is compared with existing Russian cooling channel design code. Also a design logic and quantitative effect of various parameters were introduced to help better understanding for those who is not familiar to LRE system.

Vulnerability Case Analysis of the High Power Electromagnetic Pulse on Digital Control System (디지털 제어장치의 고출력 전자기펄스에 대한 취약성 사례 분석)

  • Woo, Jeong Min;Ju, Mun-No;Lee, Hong-Sik;Kang, Sung-Man;Choi, Seung-Kyu;Lee, Jae-Bok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.9
    • /
    • pp.698-706
    • /
    • 2017
  • The risk of high power electromagnetic(HPEM) pulse exposure to the devices used in digital control system such as PLC(programmable logic controller) and communication cable is increasing. In this paper, two different frequency ranges HPEMs were exposed to those control systems to assess the each vulnerability. The vulnerability of the EUTs exposed from HPEM were analyzed and compared with a variation of distances and source power. As the EUTs were exposed to higher level of HPEM, the voltage and communication waveform of the control system had shown a distorted response. And the unshielded twisted pair(UTP) cable connected to the EUTs showed operation failures with induced voltage. However, the foiled twisted pair(FTP) cable shielded the connected device efficiently from the HPEM exposure. Therefore, the necessity of the protection measures against the vulnerability of HPEM exposure for the digital control system used in power facilities and industrial site were verified.

DCM DC-DC Converter for Mobile Devices (모바일 기기용 DCM DC-DC Converter)

  • Jung, Jiteck;Yun, Beomsu;Choi, Joongho
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.319-325
    • /
    • 2020
  • In this paper, a discontinuous-conduction mode (DCM) DC-DC buck converter is presented for mobile device applications. The buck converter consists of compensator for stable operations, pulse-width modulation (PWM) logic, and power switches. In order to achieve small hardware form-factor, the number of off-chip components should be kept to be minimum, which can be realized with simple and efficient frequency compensation and digital soft start-up circuits. Burst-mode operation is included for preventing the efficiency from degrading under very light load condition. The DCM DC-DC buck converter is fabricated with 0.18-um BCDMOS process. Programmable output with external resistors is typically set to be 1.8V for the input voltage between 2.8 and 5.0V. With a switching frequency of 1MHz, measured maximum efficiency is 92.6% for a load current of 100mA.