• 제목/요약/키워드: lock plate

검색결과 23건 처리시간 0.015초

Experimental study on RC beams externally bonded by CFRP sheets with and without end self-locking

  • Chaoyang Zhou;Yanan Yu;Chengfeng Zhou;Xuejun He;Yi Wang
    • Steel and Composite Structures
    • /
    • 제48권5호
    • /
    • pp.599-610
    • /
    • 2023
  • To avoid debonding failure, a novel type of hybrid anchorage (HA) is proposed in this study that uses a slotted plate to lock the ends of the fiber-reinforced polymer (FRP) sheet in addition to the usual bonding over the substrate of the strengthened member. An experimental investigation was performed on three groups of RC beams, which differed from one another in either concrete strength or steel reinforcement ratio. The test results indicate that the end self-locking of the CFRP sheet can improve the failure ductility, ultimate capacity of the beams and its utilization ratio. Although intermediate debonding occurred in all the strengthened beams, it was not a fatal mode of failure for the three specimens with end anchorage. Among them, FRP rupture occurred in the beam with higher concrete strength and lower steel reinforcement ratio, whereas the other two failed by concrete crushing. The beam strengthened by HA obtained a relatively high percentage of increase in ultimate capacity when the rebar ratio or concrete strength decreased. The expressions in the literature were inspected to calculate the critical loads at intermediate debonding, FRP rupturing and concrete crushing after debonding for the strengthened beam. Then, the necessity of further research is addressed.

치과의료기관 의료장비 표면 및 치과위생사 손의 Staphylococcus epidermidis 오염도 조사 (Survey of Staphylococcus epidermidis Contamination on the Hands of Dental Hygienists and Equipment Surface of Dental Clinics)

  • 김설희
    • 치위생과학회지
    • /
    • 제17권6호
    • /
    • pp.472-480
    • /
    • 2017
  • 치과의료기관 의료장비 표면 및 치과위생사 손의 S. epidermidis 오염도 조사를 위해 2017년 7월부터 8월까지 일부지역 20개 치과의원에서 치과위생사 20인의 손 오염, 치과별 7부위 표면 140부위의 S. epidermidis 오염도를 조사하였다. S. epidermidis 오염도는 핸드플레이트와 로닥플레이트를 사용하였으며, $35^{\circ}C$ 24시간 배양하였다. 손 오염도는 핸드플레이트 기준에 근거하여 저, 중, 고 그룹으로 분류한 후 그룹별 손 부위별 오염도를 ANOVA 분석하였다. 의료장비 표면 오염수준은 집락을 계수하여 기술통계 하였다. 치과위생사 55%는 중등도 이상의 손 오염이 있었고, 부위별로는 손바닥이 29.45 CFU로 가장 높게 나타났으며, 그 다음으로는 중지 7.8 CFU, 약지 6.4 CFU, 엄지 6 CFU 순서였다. 의료장비 표면 오염도 조사결과 3-way 손잡이 4.45 CFU, 컴퓨터 마우스 3.37 CFU, 거울 손잡이 1.60 CFU로 다른 영역보다 높게 조사되었다. 손 오염도가 높은 집단일수록 손의 S. epidermidis 오염도가 높은 양적 상관관계를 나타내었다. S. epidermidis 오염도는 의료장비 표면 오염보다 손에서 높게 나타났다. 그러므로 의료진들은 손 위생의 중요성을 인식하고 WHO에서 제시한 방법으로 손 위생을 실천하는 것이 요구되었다. 의료진들이 감염관리 업무수행에 책임감을 갖고 안전한 의료 환경을 조성할 수 있도록 감염관리 지침과 체계적인 감염관리 업무 수행에 관한 교육이 요구되었다.

Development and feasibility test of sit-to-stand transfer assistive device

  • Ha, SinHo;Jeong, SeYeon;Hong, SoungKyun;Choi, Wonjae;Lee, Kwangkook;Park, Donghwan;Son, SangJun;Shin, HyeonHui;Lee, GyuChang
    • 대한물리치료과학회지
    • /
    • 제29권1호
    • /
    • pp.41-46
    • /
    • 2022
  • Background: The purpose of this study was to develop a sit-to-stand transfer assistive device, and to conduct a feasibility test. Design: A technical note. Methods and results: In this study, we developed a sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. The sit-to-stand transfer assistive device allows the user to transfer the weight from a sitting position to a standing position while shifting the weight forward by grabbing and pulling a support stand. Ten healthy adults participated in the feasibility test of the device. Each participant used the developed sit-to-stand transfer assistive device and investigated supplementation through a brief interview. As a result of the feasibility test, the opinion was that the device could assist the sit-to-stand transfer to some extent. There were opinions that it needed a function to adjust the height of the knee protective plate in the sitting position according to the user's physical characteristics. Because of the inconvenience of operating the lock device for fixing the position and adjusting inclination, there was an opinion that the improvement for a locking device is needed. There were opinions that it would be better to reduce the size of the device due to its inconvenience of portability. Conclusion: In this study, we developed the sit-to-stand transfer assistive device for the elderly and the disabled who have difficulty standing up independently from sitting positions. In addition, it is considered that the upgrade of the device is necessary for the future since there are supplementary opinions on some points.