• 제목/요약/키워드: location intensity

검색결과 465건 처리시간 0.032초

영어 문장 내 상이한 위치에 나타난 저성조 피치 액센트 연구 (A Study on Low Pitch Accent Produced in Different Locations in English Sentences)

  • 이서배;김수정
    • 말소리와 음성과학
    • /
    • 제3권4호
    • /
    • pp.63-70
    • /
    • 2011
  • Recent studies on English $L^*$ (low pitch accent) have revealed the difference of changes in acoustic manifestation between utterances produced by Koreans and those produced by native speakers of English. However, not much effort has been made to compare $L^*$ focused constituents and non-focused constituents. At the same time, most previous works on focus realization are lacking in terms of normalization of acoustic measurement. Therefore, this research is dedicated to comparing the $L^*$ focused items and non-focused items realized by Koreans and Americans and to examining the realization of English $L^*$ produced by the two language groups with improved normalization of the acoustic features (F0, intensity and duration). Within-group analysis comparing focused words and non-focused words showed both Americans and Koreans prolonged the $L^*$ focused syllables but the effect size of syllable lengthening made by Koreans was far less than that made by Americans. Furthermore, significant F0 lowering was found in Americans but not in Koreans. However, the effect of intensity change caused by $L^*$ focus was not significant within each group. The effect of focused words was tested between the two groups revealing that Koreans implemented English $L^*$ focus with higher F0, lower intensity and shorter duration than Americans. In the instances in which a significant Group x Focus Location (initial, middle and final of a sentence) interaction was found, further analysis testing the effect of Group on each Focus Location was conducted. The testing showed that the Koreans produced shorter syllables at initial and middle of a sentence and higher F0 at initial of a sentence than Americans. Implications for the intonation training were also discussed.

  • PDF

도농교류 접근성을 고려한 농촌마을 공동시설의 입지평가모델 개발 (Developing Location-Evaluation Model on Community Facilities in Rural Villages Considering Accessibility for Urban-Rural Exchange)

  • 구희동;김대식;도재형
    • 농촌계획
    • /
    • 제21권2호
    • /
    • pp.115-126
    • /
    • 2015
  • Although the frequency of use for community facilities in rural villages is growing as well as the importance of the facilities for urban-rural exchange is being highlighted, study on spatial location-analysis of the facilities for such multi-purpose is not so much. This study aims to find the spatial distribution forms of community facilities in rural villages such as community center and rural-pocket park through location-analysis, in order to provide available data for selecting location in the future. As the study area, Sojeong-myeon, Sejong Special City was selected. This study conducted GIS analysis for criteria of the location-evaluation model developed in this study. This study introduced the concept of time-distance for accessibility analysis. This paper also used linear-consecutive scoring method(LCSM) as a scoring method of criteria and Analytic Hierarchy Process(AHP) method for weighting values of criteria. The application results showed that the new model can generate the intensity of community facilities according to spatial distribution and accessibility from cities to the facilities.

Analysis of Image Distortion on Magnetic Resonance Diffusion Weighted Imaging

  • Cho, Ah Rang;Lee, Hae Kag;Yoo, Heung Joon;Park, Cheol-Soo
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.381-386
    • /
    • 2015
  • The purpose of this study is to improve diagnostic efficiency of clinical study by setting up guidelines for more precise examination with a comparative analysis of signal intensity and image distortion depending on the location of X axial of object when performing magnetic resonance diffusion weighted imaging (MR DWI) examination. We arranged the self-produced phantom with a 45 mm of interval from the core of 44 regent bottles that have a 16 mm of external diameter and 55 mm of height, and were placed in 4 rows and 11 columns in an acrylic box. We also filled up water and margarine to portrait the fat. We used 3T Skyra and 18 Channel Body array coil. We also obtained the coronal image with the direction of RL (right to left) by using scan slice thinkness 3 mm, slice gap: 0mm, field of view (FOV): $450{\times}450mm^2$, repetition time (TR): 5000 ms, echo time (TE): 73/118 ms, Matrix: $126{\times}126$, slice number: 15, scan time: 9 min 45sec, number of excitations (NEX): 3, phase encoding as a diffusion-weighted imaging parameter. In order to scan, we set b-value to $0s/mm^2$, $400s/mm^2$, and $1,400s/mm^2$, and obtained T2 fat saturation image. Then we did a comparative analysis on the differences between image distortion and signal intensity depending on the location of X axial based on iso-center of patient's table. We used "Image J" as a comparative analysis programme, and used SPSS v18.0 as a statistic programme. There was not much difference between image distortion and signal intensity on fat and water from T2 fat saturation image. But, the average value depends on the location of X axial was statistically significant (p < 0.05). From DWI image, when b-value was 0 and 400, there was no significant difference up to $2^{nd}$ columns right to left from the core of patient's table, however, there was a decline in signal intensity and image distortion from the $3^{rd}$ columns and they started to decrease rapidly at the $4^{th}$ columns. When b-value was 1,400, there was not much difference between the $1^{st}$ row right to left from the core of patient's table, however, image distortion started to appear from the $2^{nd}$ columns with no change in signal intensity, the signal was getting decreased from the $3^{rd}$ columns, and both signal intensity and image distortion started to get decreased rapidly. At this moment, the reagent bottles from outside out of 11 reagent bottles were not verified from the image, and only 9 reagent bottles were verified. However, it was not possible to verify anything from the $5^{th}$ columns. But, the average value depends on the location of X axial was statistically significant. On T2 FS image, there was a significant decline in image distortion and signal intensity over 180mm from the core of patient's table. On diffusion-weighted image, there was a significant decline in image distortion and signal intensity over 90 mm, and they became unverifiable over 180 mm. Therefore, we should make an image that has a diagnostic value from examinations that are hard to locate patient's position.

Prediction of Cavitation Intensity in Pumps Based on Propagation Analysis of Bubble Collapse Pressure Using Multi-Point Vibration Acceleration Method

  • Fukaya, Masashi;Ono, Shigeyoshi;Udo, Ryujiro
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권2호
    • /
    • pp.165-171
    • /
    • 2009
  • We developed a 'multi-point vibration acceleration method' for accurately predicting the cavitation intensity in pumps. Pressure wave generated by cavitation bubble collapse propagates and causes pump vibration. We measured vibration accelerations at several points on a casing, suction and discharge pipes of centrifugal and mixed-flow pumps. The measured vibration accelerations scattered because the pressure wave damped differently between the bubble collapse location and each sensor. In a conventional method, experimental constants are proposed without evaluating pressure propagation paths, then, the scattered vibration accelerations cause the inaccurate cavitation intensity. In our method, we formulated damping rate, transmittance of the pressure wave, and energy conversion from the pressure wave to the vibration along assumed pressure propagation paths. In the formulation, we theoretically defined a 'pressure propagation coefficient,' which is a correlation coefficient between the vibration acceleration and the bubble collapse pressure. With the pressure propagation coefficient, we can predict the cavitation intensity without experimental constants as proposed in a conventional method. The prediction accuracy of cavitation intensity is improved based on a statistical analysis of the multi-point vibration accelerations. The predicted cavitation intensity was verified with the plastic deformation rate of an aluminum sheet in the cavitation erosion area of the impeller blade. The cavitation intensities were proportional to the measured plastic deformation rates for three kinds of pumps. This suggests that our method is effective for estimating the cavitation intensity in pumps. We can make a cavitation intensity map by conducting this method and varying the flow rate and the net positive suction head (NPSH). The map is useful for avoiding the operating conditions having high risk of cavitation erosion.

집중 부가물이 보강판의 진동파워 흐름에 미치는 영향에 대한 수치 해석적 고찰 (Numerical Analysis on the Affection of Lumped Attachments to the Vibration Power Flow in Cross-stiffened Plate)

  • 조대승;정상민;김재홍
    • 대한조선학회논문집
    • /
    • 제40권1호
    • /
    • pp.36-46
    • /
    • 2003
  • To investigate the affection of lumped mass and spring on the vibration power flow of cross-stiffened plate experiencing bending vibration, structural intensity analysis is done using the modal analysis based on assumed mode method. The numerical analysis is carried out varying the mass and spring constant and their attached positions. The results show that both the spring and the mass may cause to large variation of not only vibratory displacement but also vibratory power flow patterns in case of little change of natural frequencies, and the attachments near to excitation location can effectively reduce the magnitude of maximum structural intensity.

진동인텐시티를 이용한 로타리압축기 진동 해석 (Vibration Analysis of Rotary Compressor based on Vibration Intensity)

  • 안병하;이장우
    • 한국정밀공학회지
    • /
    • 제20권9호
    • /
    • pp.166-172
    • /
    • 2003
  • Vibration and Noise of air conditioner are entirely determined by compressor vibration. Compressor vibration transmitted to the enclosure of air conditioner or pipes connected compressor with heat exchanger. Enclosure generate(noise and vibration. Therefore, the analysis of compressor vibration analysis is considered significant technical issue. For the reduction of vibration of compressor, it is necessary to grasp correctly vibration transmission paths and excitation sources in the compressor shell. Because, shell ( Surface of compressor ) shows whole vibration characteristic of compressor mechanism. In this paper, vibration intensity was applied to measure vibration energy flow on the shell .From this technique, it is possible to catch the path of vibration propagation along the one cycle and the location of vibration energy sources may change with time on the shell.

Hertzian 접촉하중시 TiN/Steel의 표면균열에 대한 모드 I과 모드 II 응력확대계수 (Mode I and Mode II Stress Intensity Factors for a Surface Cracked in TiN/Steel Under Hertzian Rolling Contact)

  • 김병수;김위대
    • 대한기계학회논문집A
    • /
    • 제25권8호
    • /
    • pp.1163-1172
    • /
    • 2001
  • The two dimensional problem of a layered tribological system(TiN/Steel) containing a vertical surface breaking crack and subject to rolling contact is considered in this study. Using finite elements and stress extrapolation method, a series of preliminary models are developed. Preliminary results indicate that the extrapolation technique is valid to determine Modes I and II stress intensity factors for cracks. In the case of TiN/Steel medium, KI and KII were determined for variations in crack length, layer thickness, and load location. The results show that KII reaches maximum values when the contact is adjacent to the crack where Mode I stresses are compressive. KII values decrease with decreased crack length and significantly decrease for reduced layer thickness.

진동인텐시티를 이용한 로타리압축기 진동 해석 (Vibration Analysis of Rotary Compressor based on Vibration Intensity)

  • 이장우;김영종;안병하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.973-978
    • /
    • 2003
  • Vibration and Noise of air conditioner are entirely determined by compressor vibration. Compressor vibration transmitted to the enclosure of air conditioner or Pipes connected compressor with heat exchanger. Enclosure generated noise and vibration. Therefore, the analysis of compressor vibration analysis is considered significant technical issue. For the reduction of vibration of compressor, it is necessary to grasp correctly vibration transmission paths and excitation sources in the compressor shell. Because, shell (Surface of compressor) shows whole vibration characteristic of compressor mechanism. In this paper, vibration intensity was applied to measure vibration energy flow on the shell. From this technique, it is possible to catch the path of vibration propagation along the one cycle and the location of vibration energy sources may change with time on the shell.

  • PDF

Reynolds수와 난류강도의 변화에 따른 실린더 주위 유동 박리점의 거동에 관한 실험적 연구 (An experimental study of flow separation around a circular cylinder with Reynolds number and free stream turbulence intensity variations)

  • 임용섭;손동기;양경수;이준식
    • 대한기계학회논문집B
    • /
    • 제22권7호
    • /
    • pp.889-898
    • /
    • 1998
  • The influences of the Reynolds number and free-stream turbulence intensity on the flow separation behavior around a circular were investigated experimentally. The range of the Reynolds number and turbulence intensity considered are 10,000 ~ 45,000 and 0.3 ~ 6.8%, respectively. Because of ineffectiveness of using time-mean value of hot-film sensor signals in determining the separation location around the cylinder, a new method using phase-difference of hot-film sensor signals with hot-wire being located in shedding vortex is suggested. The validity of the present method is confirmed by the comparison with flow visualization.

Optimal design of shape of a working in cracked rock mass

  • Mirsalimov, Vagif M.
    • Geomechanics and Engineering
    • /
    • 제24권3호
    • /
    • pp.227-235
    • /
    • 2021
  • A criterion and a method for solving a problem on the prevention of mine working fracture under the action of tectonic and gravitational forces are offered. Based on minimal criterion, theoretical analysis of the definition of the optimal shape of working in the rock mass weakened by arbitrarily located rectilinear cracks was carried out. A closed system of algebraic equations allowing to minimize the stress state and stress intensity factors depending on mechanical and geometrical characteristics of the rock, is constructed. The relation between the shape of the working and the stress intensity factors and also location and sizes of the cracks is obtained. The found optimal shape of working increases load-bearing capacity of the rock.