• Title/Summary/Keyword: location detection

Search Result 1,591, Processing Time 0.031 seconds

Usefulness of High-B-value Diffusion - Weighted MR Imaging for the Pre-operative Detection of Rectal Cancers (B-values 변환 자기공명영상: 국소 직장암 수술 전 검출을 위한 적합한 b-value 유용성)

  • Lee, Jae-Seung;Goo, Eun-Hoe;Lee, Sun-Yeob;Park, Cheol-Soo;Choi, Ji-Won
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.683-690
    • /
    • 2009
  • The purpose of this study is to evaluate the usefulness of high-b-values diffusion weighted magnetic resonance imaging for the preoperative detection of focal rectum cancers. 60patients with diffusion weighted imaging were evaluated for the presence of rectal cancers. Forty were male and twenty were female, and their ages ranged from 38 to 71 (mean, 56) years. Used equipment was 1.5Tesla MRI((GE, General Electric Medical System, Excite HD). Examination protocols were used the fast spin echo T2, T1 weighted imaging. All examination protocols were performed by the same location with diffusion weighted imaging for accuracy detection. The b-values used in DWI were 250, 500, 750, 1000. 1500, 2000$(s/mm^2)$. The rectum, bladder to tumor contrast-to-noise ratio (CNR) of MR images were quantitativlely analyzed using GE software Functool tool, four experienced radiologists and three radiotechnologists qualitatively evaluated image quality in terms of image artifacts, lesion conspicuity and rectal wall. These data were analysed by using ANOVA and Freedman test with each b-value(p<0.05). Contrast to noise ratio of rectum, bladder and tumor in b-value 1000 were 27.21, 24.44, respectively(p<0.05) and aADC value was $0.73\times10^{-3}$. As a qualitative analysis, the conspicuity and discrimination from the rectal wall of lesions were high results as $4.0\pm0.14$, $4.4\pm0.16$ on b-value 1000(p<0.05), image artifacts were high results as $4.8\pm0.25$ on b-value 2000(p<0.05). In conclusion, DWI was provided useful information with depicting the pre-operative detection of rectal cancers, High-b-value 1000 image was the most excellent DWI value.

Preoperative Detection of Hepatic Metastases from the colorectal Cancers: Comparison of Dual-phase CT scan, Mn-DPDP enhanced MRI, and combination of CT and MRI (대장암의 간 전이 진단: 이중시기 CT, Mn-DPDP 조영증강 MRI, 그리고 CT-MRI 종합 판독의 비교)

  • Shin, Kyung-Min;Kim, Jong-Yeol;Choi, Gyu-Seok;Kim, Hye-Jeong;Lee, Jong-Min;Chang, Yong-Min;Kim, Yong-Seon;Kang, Duk-Sik;Ryeom, Hun-Kyu
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.109-116
    • /
    • 2005
  • Purpose : To determine the usefulness of additional Mn-DPDP MRI for preoperative evaluation of the patients with colorectal cancers by comparison of dual-phase CT scan, Mn-DPDP enhanced MRI and combination of CT and MRI. Materials and Methods : Fifty-three colorectal cancer patients with 92 metastatic nodules underwent dualphase (arterial and portal) helical CT scan and Mn-DPDP MRI prior to surgery. The indication of MRI was presence or suspected of having metastatic lesions at CT scan and/or increased serum carcinoembryonic antigen (CEA) levels (10 ng/mL or more). The diagnosis was established by the combination of findings at surgery, intraoperative ultrasonography, and histopathologic examination. Two radiologists interpreted CT, MRI, and combination of CT-MRI at discrete sessions and evaluated each lesion for location, size, and intrinsic characteristics. The lesions were divided into three groups according to their diameter; 1cm<, 1-2 cm, and >2 cm. Diagnostic accuracy was evaluated using the alternative-free response receiver operating characteristic method. Detection and false positive rate were also evaluated. Results : In the lesions smaller than 1 cm, detection rate of combined CT-MRI was superior to CT or MRI alone (82%, p=0.036). The mean accuracy (Az values) of combined CT and MRI was significantly higher than that of CT in the lesions smaller than 2 cm (1 cm<, p=0.034; 1-2 cm, p=0.045). However, there was no significant difference between MRI and combined CT-MRI. The false positive rate of CT was higher than those of combined CT-MR in the lesions smaller than 1 cm (28%, p=0.023). Conclusion : Additional MRI using Mn-DPDP besides routine CT scan was helpful in differentiating the hepatic lesions (<2 cm) and could improve detection of the small hepatic metastases (<1 cm) from colorectal carcinoma.

  • PDF

Error Concealment of MPEG-2 Intra Frames by Spatiotemporal Information of Inter Frames (인터 프레임의 시공간적 정보를 이용한 MPEG-2 인트라 프레임의 오류 은닉)

  • Kang, Min-Jung;Ryu, Chul
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.2
    • /
    • pp.31-39
    • /
    • 2003
  • The MPEG-2 source coding algorithm is very sensitive to transmission errors due to using of variable-length coding. When the compressed data are transmitted, transmission errors are generated and error correction scheme is not able to be corrected well them. In the decoder error concealment (EC) techniques must be used to conceal errors and it is able to minimize degradation of video quality. The proposed algorithm is method to conceal successive macroblock errors of I-frame and utilize temporal information of B-frame and spatial information of P-frame In the previous GOP which is temporally the nearest location to I-frame. This method can improve motion distortion and blurring by temporal and spatial errors which cause at existing error concealment techniques. In network where the violent transmission errors occur, we can conceal more efficiently severe slice errors. This algorithm is Peformed in MPEG-2 video codec and Prove that we can conceal efficiently slice errors of I-frame compared with other approaches by simulations.

  • PDF

Analysis on a Location Compatibility of Forest Fire Detection Facilities according to Classification of Forest Fire Hazard Regions Types in Samcheok Area (삼척지역 산불위험지 구분에 따른 감시시설의 위치 적합성에 관한 연구)

  • Lee, Si-Young;An, Sang-Hyun
    • Fire Science and Engineering
    • /
    • v.22 no.3
    • /
    • pp.265-271
    • /
    • 2008
  • This study analyzed on the area of Samcheok, Kangwondo about forest fire alarming area and enlargement of the area. Then, visible area by unattended watching camera and watchtower for forest fire which were run by Samcheok was cross-checked with geographic information system, and it ould be whether effective on watching the area here the forest fire risk was high enough and also it could be expanded to larger forest fire. The result of study, the visible area by watching facilities only holds for 13.4% of the whole forest fire alarming area, but the forest fire can be observed even though it is occurred in small valley because of smoke and all the forest fire have been occurred in daytime. Therefore, it can be determined that watching area will be extended around 50.3% while the observation radii of watching facilities raise by 4km. However, Samcheok has much greater area of mountain area in compared to any other cities or counties, watching facilities should be installed and run additionally for extinguishing the forest fire from the beginning.

Quality Assessment of Hypertension Management of Office-based Physicians in Korea (우리 나라 개원의 고혈압 관리의 질 평가)

  • Cho, Hong-Jun;Lee, Sang-Il
    • Quality Improvement in Health Care
    • /
    • v.4 no.1
    • /
    • pp.36-49
    • /
    • 1997
  • Background : Hypertension is one of the most important risk factors of the cerebrovascular accident and coronary artery disease which are the major causes of mortality in Korea. In Korea, the quality of care provided by office-based physicians has not been evaluated formally. The purpose of this study is to assess the quality of hypertension management of office-based physicians. Method : Self-administered questionnaires were mailed to the office-based physicians with the speciality of internal medicine, general surgery, family medicine, and general practitioners. Among 2,045 physicians, 981 doctors(48.0%) replied the questionnaires. Contents of questionnaires were based on the recommendation from the JNC-V report(the Fifth Report of the Joint National Committee on Detection, Evaluation, and Treatment of High Blood Pressure), and included the criteria of diagnosis, treatment, follow-up interval, and other characteristics of physicians(age, sex, type of speciality, and location of practice). Results : Eighty four percent of the office-based physicians made diagnosis of hypertension with less than 3 times of blood pressure measurements. The performance rate of required examination for hypertensives was very low in most items. Rate of fundoscopic examination is the lowest one among them(5.9%). The performance rate of laboratory examination was also low in most items. Internists tended to order more frequent laboratory examinations than any other type of physicians. Only 11.4% of the physicians did appropriate treatments for the mild hypertension case. The antihypertensives selected by the physicians as a first line drug were in the order of beta blocker(26.4%), calcium channel blocker(23.4%), diuretics(23.1%), ACE inhibitors(14.3%). The visit interval for established hypertensives was very short. Proportion of physicians with follow-up interval longer than 4 weeks was only 4.3%. Conclusions : The overall quality of hypertension management of office-based physicians in Korea is very problematic in many aspects. So further investigations to find out the reasons of low quality arid quality of care should be initiated.

  • PDF

Finite Element Simulation of Elastic Waves for Detecting Defects and Deteriorations in Underwater Steel Plates (수중강판의 결함 및 열화 검출을 위한 탄성파 유한요소 시뮬레이션)

  • Woo, Jinho;Na, Won-Bae
    • Journal of Ocean Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.61-66
    • /
    • 2013
  • This paper presents the results of finite element simulations of elastic wave propagation in an underwater steel plate and the verification of a proposed method utilizing elastic wave-based damage detection. For the simulation and verification, we carried out the following procedures. First, three-dimensional finite element models were constructed using a general purpose finite element program. Second, two types of damages (mechanical defects and deteriorations) were applied to the underwater steel plate and three parameters (defect location, defect width, and depth) were considered to adjust the severity of the applied damages. Third, elastic waves were generated using the oblique incident method with a Gaussian tone burst, and the response signals were obtained at the receiving point for each defect or deterioration case. In addition, the received time domain signals were analyzed, particularly by measuring the magnitudes of the maximum amplitudes. Finally, the presence and severity of each type of damage were identified by the decreasing ratios of the maximum amplitudes. The results showed that the received signals for the models had the same global pattern with minor changes in the amplitudes and phases, and the decreasing ratio generally increased as the damage area increased. In addition, we found that the defect depth was more critical than the width in the decrease of the amplitude. This mainly occurred because the layout of the depth interfered with the elastic wave propagation in a more severe manner than the layout of the width. An inverse analysis showed that the proposed method is applicable for detecting mechanical defects and quantifying their severity.

Design of Integrated Urban Management System and its Applications Based on RoF and PON Technologies (RoF 및 PON 기술 기반 통합 도심 관리 시스템 (IUMS)의 설계와 그 응용)

  • Yun Chang-Ho;Cho Tae-Sik;Lim Wan-Su;Lee Hyun-Ju;Shin Sung-Moon;Kim Myun-Sik;Kim Ki-Seon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.5 s.347
    • /
    • pp.51-58
    • /
    • 2006
  • A variety of systems have been attempted for effective urban management. In this paper we introduce the Integrated Urban Management System (IUMS), which consists mainly of an optical line terminal (OLT), optical network terminals (ONTs) and wireless access points (APs), by combining passive optical network (PON) and radio over fiber (RoF) technologies so as to take advantage of both systems. Further, several IUMS services such as a disaster detection and prevention system (DDPS), a bus information system (BIS) and a real time location system (RTLS) we demonstrated in order to verify the employment of IUMS for the realization of a future ubiquitous city (U-city).

Late Stage and Grave Prognosis of Esophageal Cancer in Thailand

  • Nun-anan, Pongjarat;Vilaichone, Ratha-korn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.1747-1749
    • /
    • 2015
  • Background: Esophageal cancer is one of the major health concerns in Southeast Asian countries, including Thailand. However, only a limited number of studies have been reported from this region. This study was designed to evaluate the prevalence, clinical characteristics and survival rate of esophageal cancer in Thailand. Materials and Methods: Clinical information, histological features and endoscopic findings were collected from a tertiary care center in central region of Thailand between September 2011- November 2014 and reviewed. Results: A total of 64 esophageal cancer patients including 58 men and 6 women with mean age of 62.6 years were enrolled. Common presenting symptoms were dysphagia (74%), dyspepsia (10%) and hematemesis (8%). Mean duration of symptoms prior to diagnosis was 72 days. Esophageal stenosis with contact bleeding was the most common endoscopic finding (55.6%). The location of cancer was found in proximal (16%), middle (50%) and distal (34%) esophagus. Squamous cell carcinoma was far more common histology than adenocarcinoma (84.2% vs 10.5%). However, esophageal adenocarcinoma was significantly more common than squamous cell carcinoma in distal area of esophagus (100% vs 22.9%; p=0.0001, OR=1.6, 95%CI=1.1-2.2). Esophageal cancer stages 3 and 4 accounted for 35.2% and 59.3% respectively. Overall 2-year survival rate was 20% and only 16% in metastatic patients. Conclusions: Most esophageal cancer patients in Thailand have squamous cell carcinoma and nearly all present at advanced stage with a grave prognosis. Screening of high risk individuals and early detection might be important keys to improve the survival rate and treatment outcome in Thailand.

The Design of Object-of-Interest Extraction System Utilizing Metadata Filtering from Moving Object (이동객체의 메타데이터 필터링을 이용한 관심객체 추출 시스템 설계)

  • Kim, Taewoo;Kim, Hyungheon;Kim, Pyeongkang
    • Journal of KIISE
    • /
    • v.43 no.12
    • /
    • pp.1351-1355
    • /
    • 2016
  • The number of CCTV units is rapidly increasing annually, and the demand for intelligent video-analytics system is also increasing continuously for the effective monitoring of them. The existing analytics engines, however, require considerable computing resources and cannot provide a sufficient detection accuracy. For this paper, a light analytics engine was employed to analyze video and we collected metadata, such as an object's location and size, and the dwell time from the engine. A further data analysis was then performed to filter out the target of interest; as a result, it was possible to verify that a light engine and the heavy data analytics of the metadata from that engine can reject an enormous amount of environmental noise to extract the target of interest effectively. The result of this research is expected to contribute to the development of active intelligent-monitoring systems for the future.

Research of Phase Correlation Method for Identifying Quantitative Similarity in Adjacent Real-time Streaming Frame

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.157-157
    • /
    • 2017
  • To minimize the damage by wild birds and acquire the benefits such as protection against weeds and maintenance of water content in soil, the mulching black color vinyl after seeding should be carried out. Non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. Non-linear integral interpolation was one of method for analyzing the frequency using the normalization image and then arbitrarily increasing the limited data value of $16{\times}4pixels$ in one frame. It was a method to relatively reduce the size of overlapping pixels by arbitrarily increasing the limited data value. The splitted frames into 0.1 units instead of 1 pixel can propose more than 10 times more accurate and original method than the existing correction method. The non-integral calibration method was conducted by applying the subdivision method to the pixels to find the optimal correction resolution based on the first reversed frequency. In order to find a correct resolution, the expected location of the first crop was indicated on near pixel 4 in the inversion frequency. For the most optimized resolution, the pixel was divided by 0.4 pixel instead of one pixel to find out where the lowest frequency exists.

  • PDF