• Title/Summary/Keyword: location assessment

Search Result 751, Processing Time 0.027 seconds

Prospects of Cumulative Installed Power Capacity of Domestic Offshore Wind Projects for K-RE100 (K-RE100 이행에 필요한 국내해상풍력단지 누적 설치량 전망 연구)

  • Hong Goo Kang;Byung Ha Kim;Hun Jo Kim;Chang Jo Yang;Hae Chang Jeong
    • New & Renewable Energy
    • /
    • v.20 no.2
    • /
    • pp.44-54
    • /
    • 2024
  • The objective of this study was to contribute to domestic offshore wind farms by reasonably predicting the expected completion time and installed power generation capacity of offshore wind projects in South Korea. Offshore wind power is drastically regarded as a core tool for clean energy transition and industrial decarbonization in the fight against the climate crisis globally. Especially in South Korea offshore wind power is the main tool in partaking in RE100 and K-RE100, and the Korean government aims to install 14.9 GW of offshore wind farms by 2030. However, this seems to have been significantly delayed due to the complex process of obtaining permits for offshore wind power in Korea. Thus, a reasonable prediction of power generation and a timeline for the final construction are imperative. To establish the delay time for permit licenses, classified location factors were included into site analysis. These factors comprised reviews of transmission and military operability, environmental impact assessment, maritime traffic safety examination, wind resource assessment and an analysis of current offshore wind projects. According to the analysis, the majority of offshore wind projects currently being developed in Korea are predicted to be delayed by 3-5 years as they are among the criteria included in key discussion points for obtaining permits. The cumulative installed power capacity and annual power generation after construction are expected to be 37 GW and 97 TWh respectively.

Open Space Spacial Pattern Analysis from the Perspective of Urban Heat Mitigation (도시 열저감 관점에서의 오픈스페이스 토지이용 공간패턴분석)

  • Sangjun Kang
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.4
    • /
    • pp.155-163
    • /
    • 2024
  • The purpose is to explore the meaning of the open space land use space pattern from the perspective of urban heat reduction using the land-use scenario. The employed methods are as follows: (1) to calculate the cooling capacity Index for each of five land use scenarios, using the InVEST Urban Cooling Model, (2) to calculate open space entropy & morphological spatial pattern for each land use scenario, using the Guidos Spatial Pattern Toolbox, and (3) to perform a Spearman rank correlation analysis between the InVEST and Guidos results. It is found that the rank correlation is moderate between the cooling capacity Index and the open space area ratio (rho=0.50). However, other relations are low. It is observed that only the total amount of open space is likely to have a meaning from the perspective of urban heat reduction, and that other open space location spatial patterns may not have much meaning from the perspective of urban thermal environment management.

Environmentally Available Potential of Renewable Energy in Korea: Onshore Wind and Photovoltaic (육상풍력 및 육상태양광의 환경적 가용입지 분석)

  • Lee, Young-Joon;Park, Jong-Yoon
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.6
    • /
    • pp.339-354
    • /
    • 2021
  • The purpose of this study is to provide valuable information and data by analyzing the environmental status and potential forrenewable energy projects (or plans) based on environmental assessment (EA) data, so that more objective and scientific environmental assessments can be conducted. The study also suggests regional directions that could satisfy the goals of nature conservation and renewable energy. Based on the analysis of EA data that was conducted up until June 2019, the study analyzed the size, location and characteristics of both onshore wind power and onshore photovoltaic. The environmentally available potential by region was also derived by considering the main constraints and requirements related to the potential siting ofrenewable energy projects at the EA. Based on EA data, 63 out of 80 (79%) onshore wind power projects are shown to be located in mountainous areas. For onshore photovoltaic projects, a total of 7,363 projects were subjected to environmental assessment over the country. The environmentally potential area for onshore wind power, considering all the environmental regulatory factors, is 2,440 km2. For onshore photovoltaic, the environmentally available area estimated as idle farmland is 2,877 km2. The distribution and characteristics of the environmentally available potential of the region may be the most important factor that local governments should bear in mind in terms of promoting renewable energy development projects in the region. Based on the results of this study, even if we consider the national energy plan including the expected future increase, as well as environmental goals and socio-economic acceptance through an environmental assessment, the available resources forrenewable energy projects are not insufficient. It is possible to examine the adequacy of the target distribution rate of renewable energy sources by region taking into consideration the quantitative and scientific results such as the environmentally available potential data derived from this study.

Development and Utilization of Evaluation Methods for Offshore Wind Farm Landscape Quality Assessment (해상풍력발전단지 경관의 질 평가를 위한 평가기법의 개발 및 활용방안)

  • Jin-Oh Kim;Byoungwook Min;Kyung-Sook Woo;Jin-Pyo Kim
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.577-589
    • /
    • 2023
  • In Korea, the technical techniques for assessing visual impacts are standardized, but the methods for assessing the marine landscape itself are not standardized and need to be improved. In particular, in the landscape impact assessment of offshore wind power generation in Korea, it is necessary to recognize the landscape itself as a receptor and prepare a system that can evaluate the characteristics and sensitivity of the landscape. In this study, we propose an evaluation method for preparing a marine landscape quality assessment document that reflects the project characteristics of offshore wind power projects, and examine the possibility of utilization by applying it to actual project sites as an example. To evaluate the quality of marine scenery in offshore wind power projects, evaluation items of landscape characteristics, physical characteristics, and socio-cultural characteristics were evaluated based on the preliminary survey contents, and the quality of marine scenery was divided into five grades. Next, the evaluation criteria of the evaluation items were synthesized and the quality of the marine landscape was classified into preservation grade (grade 5), semi-preservation grade (grade 4), buffer grade (grade 3), semi-improvement grade (grade 2), and improvement grade (grade 1). In addition, the Sinan-Ui Offshore Wind Farm, an actual project site, was randomly selected to conduct the evaluation process and examine its utilization. This study aims to complement the existing method of visual impact assessment in offshore wind power projects and evaluate the quality of the marine landscape itself to effectively conserve marine landscape resources during offshore wind power projects. Rather than relying on mechanical and quantitative evaluation, this study is expected to be used as a basis for comprehensive understanding of the location and socio-cultural characteristics of the project site and for communication and cooperation with stakeholders.

Assessment of location of the air quality monitoring stations according to the analysis of wind sector division in Pohang (포항지역의 바람권역 분석에 따른 대기측정망 위치 평가)

  • Jung, Jong-Hyeon;Lee, Hyung-Don;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1931-1938
    • /
    • 2012
  • This study evaluated whether the installed location of air quality monitoring stations is at an optimal level in an effort to improve the health and environmental quality of the surrounding areas of the Pohang Steel Complex. As a result of analyzing the atmospheric flow field, it was found that the location of air quality monitoring stations was acceptable in case of Daesong-myeon(The 1st Division of Local Wind Sector) and Jukdo-dong(The 3rd Division of Local Wind Sector). However, the air quality monitoring stations installed at Daedo-dong and Jukdo-dong is judged to have made an overlapped measurement because the stations existed at the Division of the same Wind Sector. Accordingly, this study suggests that the further air quality monitoring stations should be additionally installed at Buk-gu areas of Pohang where more than 50% of the population of Pohang is living presently. As a result of the analysis of air contaminant concentration distribution, the Jangheung-dong area showed higher concentration distribution than other areas in case of $PM_{10}$ while the Daesong-myeon area showed a comparatively higher concentration distribution in case of $O_3$. Conclusively, this study indicates that it is high time to prepare an aggressive management of $PM_{10}$ and $O_3$ which causes a harmful impact on the life and health of the residents of the target areas.

An Analysis on the Status of Barrier Free Design Certifications in Center for Elderly (경로당 건축물의 장애물 없는 생활환경 인증실태 분석)

  • Lee, Jeong-Soo;Oh, Young-Sook;Eun, Dong-Shin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.313-320
    • /
    • 2018
  • The purposes of this study were to verify the status of Barrier Free Design Certification in the center for the elderly. To achieve these purposes, the architectural characteristics of the center for elderly and the status of Barrier Free Design Certification was analyzed. The results of this study were as follows. (1) The functional composition of centers for the elderly are similar regardless of the location, but the area and shape of the plot are very different according to the location. (2) According to an analysis on the status of Barrier Free Design Certification in centers for elderly, the sanitation and intermediate facilities are necessarily considerable adjustment. (3) For the accessability and conveniences of Barrier Free Design Certification in a small building, such as centers for the elderly, they are necessary to simplify the self-assessment documents, minimize the period for judging, and reducing the fees for certification.

Bare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location (혈액투석 접근로 기능부전에서의 비피복형 스텐트: 접근로 종류와 스텐트 위치에 따른 개통률 평가)

  • Kyungmin Lee;Je Hwan Won;Yohan Kwon;Su Hyung Lee;Jun Bae Bang;Jinoo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.197-211
    • /
    • 2023
  • Purpose To evaluate the circuit patency after nitinol bare-metal stent (BMS) placement according to the type of access and location of the stent in dysfunctional hemodialysis access. Materials and Methods Between January 2017 and December 2019, 159 patients (mean age, 64.1 ± 13.2 years) underwent nitinol BMS placement for dysfunctional access. The location of stents was as follows: 18 brachiocephalic vein, 51 cephalic arch, 40 upper arm vein, 10 juxta-anastomotic vein, 7 arteriovenous (AV) anastomosis, and 33 graft-vein (GV) anastomosis. Circuit patency was evaluated by the Kaplan-Meier method, and cox regression model. Results A total of 159 stents were successfully deployed in 103 AV fistula (AVF) and 56 AV graft (AVG). AVG showed lower primary and secondary patency at 12-months compared with AVF (primary patency; 25.0% vs. 44.7%; p = 0.005, secondary patency; 76.8% vs. 92.2%; p = 0.014). Cox regression model demonstrated poorer primary patency at 12 months after stenting in the cephalic arch and GV anastomosis compared with the other sites. Conclusion AVF showed better primary and secondary circuit patency at 12 months following the placement of BMS compared with AVG. Stents in the cephalic arch and GV anastomosis were associated with poorer primary patency at 12 months compared to those in other locations.

Assessment of a smartphone-based monitoring system and its application

  • Ahn, Hoyong;Choi, Chuluong;Yu, Yeon
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.3
    • /
    • pp.383-397
    • /
    • 2014
  • Information technology advances are allowing conventional surveillance systems to be combined with mobile communication technologies, creating ubiquitous monitoring systems. This paper proposes monitoring system that uses smart camera technology. We discuss the dependence of interior orientation parameters on calibration target sheets and compare the accuracy of a three-dimensional monitoring system with camera location calculated by space resectioning using a Digital Surface Model (DSM) generated from stereo images. A monitoring housing is designed to protect a camera from various weather conditions and to provide the camera for power generated from solar panel. A smart camera is installed in the monitoring housing. The smart camera is operated and controlled through an Android application. At last the accuracy of a three-dimensional monitoring system is evaluated using a DSM. The proposed system was then tested against a DSM created from ground control points determined by Global Positioning Systems (GPSs) and light detection and ranging data. The standard deviation of the differences between DSMs are less than 0.12 m. Therefore the monitoring system is appropriate for extracting the information of objects' position and deformation as well as monitoring them. Through incorporation of components, such as camera housing, a solar power supply, the smart camera the system can be used as a ubiquitous monitoring system.

Numerical Reconstruction of Holographic Stereogram with Radial Distortion (방사 왜곡을 포함하는 홀로그래픽 스테레오그램의 수학적 복원)

  • Park, Jiyong;Kang, Hoonjong;Hong, Sunghee;Jung, Kwangmo;Lee, Seunghyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38C no.10
    • /
    • pp.911-919
    • /
    • 2013
  • Evaluation of the effect of radial distortion for a holographic stereogram demands conducting an experiment which comprises rendering of a 3D obejc, acquisition of perspective images, rearrangement of the acquired images for hogel images and quality assessment of the observing image reconstructed from the holographic stereogram. We propose numerical implementation of this evaluation by a specially developed algorithm for modeling of all required steps. The modeling is done by using a numerical model of an optical engine for generation of radially distorted hogel images at various degrees of distortion. The distorted images are used to form the holographic stereogram and to make the numerically reconstructed images from the holographic stereogram which are observed by an observer at desired location. The reconstructed images are compared by using PSNR.

A Study on the Problems and Solutions of Environmental Impact Assessment System for Environmentally Sound and Sustainable Development (ESSD를 위한 지역 환경영향평가제도의 문제점 및 개선방안 연구)

  • Oh, Hae-Sub;Lim, Hyung-Baek
    • Journal of Agricultural Extension & Community Development
    • /
    • v.6 no.1
    • /
    • pp.15-24
    • /
    • 1999
  • There have always been dilemmas between development and environmental conservation throughout the world. Gradually environmental contamination threatens sustainable development and conservation. we try to study on the sustainable development with environmental conservation. One of the instruments to get this goal is Environmental Impact Statement. Environmental Impact Statement has now become a standard tool of decision making in Environmentally Sound and Sustainable Development. The objectives of this study is to explore and suggest some suggestions for improvements of EIA. 1. Identify all criteria and standards that apply to physical and social environmental components and dynamics. 2. Giving attention to the purpose of the criterion and standard, with respect to resource use and quality. 3. Demonstrate the relevance legal, technical, and scientific authority by early planning through construction, operation and maintenance phases. 4. Implement rationales and protocols for the documentation of standard analytical methods, location of sampling points and statistical analysis of data. 5. Establish precise protocols by predictions of environmental impact relevant for established criteria and standards. Reviewing these protocols with relevant legal authorities prior to their implementation is important.

  • PDF