• Title/Summary/Keyword: local water temperature

Search Result 333, Processing Time 0.034 seconds

Kinetic Study of Hydrations and Volume Change of Soybeans during Soaking (침지중 콩의 흡수 및 부피변화의 속도론적 연구)

  • Kim, Dong-Hee;Yum, Cho-Ae;Kim, Woo-Jung
    • Applied Biological Chemistry
    • /
    • v.33 no.1
    • /
    • pp.18-23
    • /
    • 1990
  • Seven varieties of soybeans(Paldal, Danyeob, Jangbaek, Baegun, Jangyeob and 2 cultivars of Local 1 and Local 2) were investigated to compare the water uptake properties and volume changes during soaking in water. The hydration properties showed that the equilibrated weight increase ratio decreased as the soaking temperature raised to higher than $40^{\circ}C$, while the initial water uptake rate increased upto $80^{\circ}C$. The increase in hydration showed a linear relationship with the square root of the soaking time at $4^{\circ}{\sim}60^{\circ}C$. Local 1 was the highest in water uptake rate constant while Local 2 was the lowest. The activation energy calculated was in the range of $3,246{\sim}4,694\;cal/mole$. The Jangbaek and Local 1 were the highest and the Paldal was the lowest in the rate of volume increase. The activation energy for volume increase was in the range of $3,310{\sim}4,190\;cal/mole$. The z-values calculated from volume change was a little higher than those obtained from weight change.

  • PDF

Method of Integrating Landsat-5 and Landsat-7 Data to Retrieve Sea Surface Temperature in Coastal Waters on the Basis of Local Empirical Algorithm

  • Xing, Qianguo;Chen, Chu-Qun;Shi, Ping
    • Ocean Science Journal
    • /
    • v.41 no.2
    • /
    • pp.97-104
    • /
    • 2006
  • A useful radiance-converting method was developed to convert the Landsat-7 ETM+thermal-infrared (TIR) band's radiance ($L_{{\lambda},L7/ETM+}$) to that of Landsat-5 TM TIR ($L_{{\lambda},L5/TM+})$ as: $L_{{\lambda},L5/TM}=0.9699{\times}L_{{\lambda},L7/ETM+}+0.1074\;(R^2=1)$. In addition, based on the radiance-converting equation and the linear relation between digital number (DN) and at-satellite radiance, a DN-converting equation can be established to convert DN value of the TIR band between Landsat-5 and Landsat-7. Via this method, it is easy to integrate Landsat-5 and Landsat-7 TIR data to retrieve the sea surface temperature (SST) in coastal waters on the basis of local empirical algorithms in which the radiance or DN of Lansat-5 and 7 TIR band is usually the only input independent variable. The method was employed in a local empirical algorithm in Daya Bay, China, to detect the thermal pollution of cooling water discharge from the Daya Bay nuclear power station (DNPS). This work demonstrates that radiance conversion is an effective approach to integration of Landsat-5 and Landsat-7 data in the process of a SST retrieval which is based on local empirical algorithms.

DEVELOPMENT OF A LOCAL MEAN TEMPERATURE EQUATION FOR GPS-BASED PRECIPITABLE WATER VAPOR OVER THE KOREAN PENINSULA (GPS 가강수량 결정을 위한 한국형 평균온도식 개발)

  • Ha, Ji-Hyun;Park, Kwan-Dong;Heo, Bok-Haeng
    • Journal of Astronomy and Space Sciences
    • /
    • v.23 no.4
    • /
    • pp.373-384
    • /
    • 2006
  • The Bevis' mean temperature equation (MTE) is generally used in estimating Precipitable Water Vapor (PWV) based on GPS measurements. Because the equation was derived from Worth American meteorological data, however, it may induce errors in PWV if the equation is applied to Korea which has different climate conditions. In this study, we developed a new MTE using local meteorological data. We compared PWVs from the new equation with those from the Bevis and two other local equations. The PWV differences from the four equations increase as a function of surface temperatures at the observation site, reaching up to $1{\sim}3mm$.

Effect of Chip Spacing in a Multichip Module on the Heat Transfer for Paraffin Slurry Flow

  • Choi, Min-Goo;Cho, Keum-Nam
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.9
    • /
    • pp.997-1004
    • /
    • 2000
  • The experiments were conducted by using water and paraffin slurry to investigate the effect of a chip spacing in the multichip module on the cooling characteristics from an in-line $4{\times}3$ array of discrete heat sources which were flush mounted on the top wall of a channel. The experimental parameters were chip spacing in a multichip module, heat flux of simulated VLSI chip, mass fraction of paraffin slurry, and channel Reynolds number. The removable heat flux at the same chip surface temperature decreased as the chip spacing decreased at the first and fourth rows. The local heat transfer coefficients for the paraffin slurry were larger than those for water, and the chip spacing on the local heat transfer coefficients for paraffin slurry influenced less than that for water. The enhancement factor for paraffin slurry showed the largest value at a mass fraction of 5% regardless of the chip spacing, and the enhancement factors increased as the chip spacing decreased. This means that the paraffin slurry is more effective than water for cooling of the highly integrated multichip module.

  • PDF

Numerical Simulation for Local Circulation of Urban Area and Deposition Phenomenon (도시지역의 국지순환과 침적현상에 관한 수치모의)

  • 이화운;오은주;노순아;반수진
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.773-787
    • /
    • 2003
  • There are variations in the temperature Held due to urban heat island and anthropogenic heating so that regional scale meteorological field is changed. Therefore we simulate and predict the regional climate change according to surface characteristics through regional meteorological model. This study investigates the regional meteorological field by urbanization that influences in local circulation system using CSU-RAMS and simulates dry deposition velocity (V$_{d}$) using PNU/DEM which includes surface characteristics (such as albedo, surface hydrology and rough-ness length etc.) with calculated meteorological field. During the summer, horizontal distributions of V$_{d}$ were simulated using CSU-RAMS and PNU/DEM at Busan metropolitan area. The estimated values of V$_{d}$ were larger in forest and agricultural areas than water areas since ozone with low water solubility is destroyed slowly at wet surface or water.water.

Study on Effect of Increase in Inlet Temperature on Nafion Membrane Humidifier (입구온도 변화가 중공사형 나피온 막가습기의 성능에 미치는 영향에 대한 연구)

  • Hwang, Jun-Young;Chang, Hyo-Sun;Kang, Kyung-Tae;Kang, Heui-Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.361-369
    • /
    • 2011
  • The effect of an increase in the temperature of inlet air on the performance of a membrane humidifier for a PEMFC (Polymer Electrolyte Membrane Fuel Cell) vehicle was investigated both experimentally and numerically. A shell-and-tube type gas-to-gas humidifier with Nafion membrane was tested. The experimental result showed that water transfer varies nonlinearly with the temperature elevation. Numerical analysis based on detailed modeling was also conducted in simplified geometry of a single tube to explain this nonlinear behavior. The simulation revealed that the local water flux varies nonlinearly and dramatically along the tube. The analysis was based on the inverse relationship between the increase in temperature and decrease in relative humidity, both of which seriously affect the water conductivity of the membrane.

Measurement of temperature profile using the infrared thermal camera in turbulent stratified liquid flow for estimation of condensation heat transfer coefficients

  • Choi, Sung-Won;No, Hee-Cheon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1999.05a
    • /
    • pp.107-107
    • /
    • 1999
  • Direct-contact condensation experiments of atmospheric steam and steam/air mixture on subcooled water flowing co-currently in a rectangular channel are carried out uszng an infrared thermal camera system to develop a temperature measurement method. The inframetrics Model 760 Infrared Thermal Imaging Radiometer is used for the measurement of the temperature field of the water film for various flow conditions. The local heat transfer coefficient is calculated using the bulk temperature gradient along the (low direction. It is also found that the temperature profiles can be used to understand the interfacial condensation heat transfer characteristics according to the flow conditions such as noncondensable gas effects, inclination effect, and flow rates.

  • PDF

A MIXED CORE FOR SUPERCRITICAL WATER-COOLED REACTORS

  • Cheng, Xu;Liu, Xiao-Jing;Yang, Yan-Hua
    • Nuclear Engineering and Technology
    • /
    • v.40 no.2
    • /
    • pp.117-126
    • /
    • 2008
  • In this paper, a new reactor core design is proposed on the basis of a mixed core concept consisting of a thermal zone and a fast zone. The geometric structure of the fuel assembly of the thermal zone is similar to that of a conventional thermal supercritical water-cooled reactor(SCWR) core with two fuel pin rows between the moderator channels. In spite of the counter-current flow mode, the co-current flow mode is used to simplify the design of the reactor core and the fuel assembly. The water temperature at the exit of the thermal zone is much lower than the water temperature at the outlet of the pressure vessel. This lower temperature reduces the maximum cladding temperature of the thermal zone. Furthermore, due to the high velocity of the fast zone, a wider lattice can be used in the fuel assembly and the nonuniformity of the local heat transfer can be minimized. This mixed core, which combines the merits of some existing thermal SCWR cores and fast SCWR cores, is proposed for further detailed analysis.

The Wearing Sensation of Men and Women in Sports Wear with Waterproof and Water Vapor Permeable Fabrics (성인 남녀의 투습방수소재 스포츠 웨어의 소재별 착용감에 관한 연구)

  • Cho, Ji-Hyun;Ryu, Duck-Hwan
    • Korean Journal of Human Ecology
    • /
    • v.9 no.1
    • /
    • pp.47-61
    • /
    • 2000
  • The purpose of this study was to examine the performance and properties of sports wear that have the excellent wearing sensation and are in harmony with the functions of human bodies. With four kind(sample A, B, C, D) of materials which have different water vapor transmission, the physiological responses of human bodies and the changes of subjective sensations were studied through the actual aerobic sports program at $20^{\circ}C$, 60%R.H. The forehead temperature had the minimal variation among the local skin temperatures. The fabrics of low water vapor transmission demonstrated high breast temperature. There are significant differences among materials depending on the humidity in clothes(especially back and breast), which was about 6 % for breast and about 14 % for back. The order of loss in body weight was in the opposite direction to that of water vapor transmission for each material.

  • PDF

Cooling characteristics of the multichip module using paraffin slurry (파라핀 슬러리를 사용한 다칩모듈의 냉각특성)

  • Jo, Geum-Nam;Choe, Min-Gu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.888-898
    • /
    • 1998
  • The present study investigated the effects of the experimental parameters on the cooling characteristics of the multichip module cooled by the indirect liquid cooling method using water and paraffin slurry. The experimental parameters are mass fraction of 2.5 ~ 7.5% for paraffin slurry, heat flux of 10 ~ 40 W/cm$^{2}$ for the simulated VLSI chips and Reynolds numbers of 5,300 ~ 15,900. The apparatus consisted of test section, paraffin slurry maker, pump, constant temperature baths, flowmeter, etc. The test section made of in-line, four-row array of 12 heat sources for simulating 4 * 3 multichip module which was flush mounted on the top wall of a horizontal rectangular channel with the aspect ratio of 0.2. The inlet temperature was 20 deg. C for all experiments. The size of paraffin slurry was constant as 10 ~ 40 .mu.m befor and after the experiment. The chip surface temperatures for paraffin slurry with the mass fraction of 7.5% showed lower by 16 deg. C than those for water when the heat flux is 40 W/cm$^{2}$. The local heat transfer coefficients for the paraffin slurry with the mass fraction of 7.5% were larger by 17 ~ 25% than those for water at the first and the fourth row. The local heat transfer coefficients reached to a row-number-independent, thermally fully developed value approximately after the third row. The local Nusselt numbers at the fourth row for paraffin slurry with the mass fraction of 7.5% were larger by 23 ~ 29% than those for water.