• Title/Summary/Keyword: local resonance

Search Result 287, Processing Time 0.029 seconds

Sound Insulation Performance of the Panel Structures in High Speed Train: Transmission Loss of the Corrugated and Extruded Panels (고속철도 차음구조의 차음성능: 주름 및 압출재의 투과손실)

  • Kim, Seock-Hyun;Paek, In-Su;Kim, Jeong-Tae
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.82-89
    • /
    • 2007
  • Sound transmission characteristics are investigated on the corrugated steel and aluminium extruded panels used for railway vehicles. Sewell-Sharp-Cremer(SSC) model, equivalent orthotropic plate model and equivalent mass law are applied to predict the sound transmission loss. The predicted values of the sound transmission loss are compared with the measured values. The reliability and the limitation of the prediction models are investigated. For the corrugated panels and honeycomb panels, the coincidence and local resonance severely deteriorate the sound insulation performance around the corresponding frequency bands. The result of the study shows that the equivalent orthotropic plate model and the SSC model can be used as good prediction models, if the coincidence frequency or local resonance frequency is correctly applied.

  • PDF

Neuroactivation studies using Functional Brain MRI (기능적 자기공명영상을 이용한 뇌활성화 연구)

  • Chung, Kyung-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.1
    • /
    • pp.63-72
    • /
    • 2003
  • Functional MRI (fMRI) provides an indirect mapping of cerebral activity, based on the detection of the local blood flow and oxygenation changes following neuronal activity (Blood Oxygenation Level Dependent). fMRI allows us to study noninvasively the normal and pathological aspects of functional cortical organization. Each fMRI study compares two different states of activity. Echo-Planar Imaging is the technique that makes it possible to study the whole brain at a rapid pace. Activation maps are calculated from a statistical analysis of the local signal changes. fMRI is now becoming an essential tool in the neurofunctional evaluation of normal volunteers and many neurological patients as well as the reference method to image normal or pathologic functional brain organization.

195Pt NMR Study of the Influence of Nation Ionomer on the Enhanced Local Density of States at the Surface of Carbon-Supported pt Catalysts

  • Han, Kee-Sung;Lee, Moo-Hee
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.13 no.2
    • /
    • pp.135-142
    • /
    • 2009
  • $^{195}Pt$ NMR measurements were performed to deduce the variation of local density of states at the Fermi energy ($E_F$-LDOS) at the surface of carbonsupported Pt catalysts due to the addition of $Nafion^{(R)}$ ionomer in the metalelectrode-assembly for fuel cells. The results showed that the EF-LDOS at the surface of Pt particles was enhanced by the addition of $Nafion^{(R)}$ ionomers whereas it was uninfluenced in the inner (bulk) part of the Pt particles. This suggests that the effects of ionomers on the electronic states of the Pt particle surface are related to the electrochemical activity of the catalysts.

Flame-Vortex Interaction and Mixing in Turbulent Hydrogen Diffusion Flames with Coaxial Air (동축공기 수소확산화염에서 화염-와류 상호작용 및 혼합)

  • Kim, Mun-Ki;Oh, Jeong-Seog;Choi, Young-Il;Yoon, Young-Bin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.149-154
    • /
    • 2007
  • This study examines the effect of acoustic excitation using forced coaxial air on the flame characteristics of turbulent hydrogen nonpremixed flames. A resonance frequency was selected to acoustically excite the coaxial air jet due to its ability to effectively amplify the acoustic amplitude and reduce flame length and NOx emissions. Acoustic excitation causes the flame length to decrease by 15 % and consequently, a 25 % reduction in EINOx is achieved, compared to a flame without acoustic excitation. Moreover, acoustic excitation induces periodical fluctuation of the coaxial air velocity, thus resulting in slight fluctuation of the fuel velocity. From phase-lock PIV and OH PLIF measurement, the local flow properties at the flame surface were investigated under acoustic forcing. During flame-vortex interaction in the near field region, the entrainment velocity and the flame surface area increased locally near the vortex. This increase in flame surface area and entrainment velocity is believed to be a crucial factor in reducing flame length and NOx emission in coaxial jet flames with acoustic excitation. Local flame extinction occurred frequently when subjected to an excessive strain rate, indicating that intense mass transfer of fuel and air occurs radially inward at the flame surface.

  • PDF

The Early Detection of Recurrence of Malignant Peripheral Nerve Sheath Tumor by Frequent Magnetic Resonance Imaging

  • Lee, Chang-Sub;Huh, Ji-Soon;Chang, Jee-Won;Park, Ji-Kang
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.1
    • /
    • pp.51-54
    • /
    • 2010
  • Surgery has a key role in the treatment of malignant peripheral nerve sheath tumors (MPNSTs), but the resectability of paraspinal MPNSTs is only 20%. Therefore, spinal MPNSTs show frequent recurrence and poor prognosis. Local recurrence is much more common than metastasis for MPNSTs, and surgery still has a key role in the treatment of local recurrence. Therefore, it is important that recurrence must be detected before resectability is lost. However, no evidence-based follow-up protocol has been established for MPNST. The authors performed gross total resection in a 34-year-old woman presented with thoracic MPNST. Adjuvant radiotherapy and chemotherapy were not administered since these adjuvant therapies generally do not improve survival in MPNST and may cause additional neurovascular damage. Instead, the authors monitored the primary site every 3 months using magnetic resonance imaging to detect local recurrence at the earliest opportunity. The tumor recurred locally on two occasions without overt symptoms at 21 and 24 months postoperatively. These recurrences were treated successfully by gross total removal.

Sound-Insulation Design of Aluminum Extruded Panel in Next-Generation High-Speed Train (차세대 고속철도 차량용 알루미늄 압출재의 차음 설계)

  • Kim, Seock-Hyun;Seo, Tae-Gun;Kim, Jeong-Tae;Song, Dal-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.5
    • /
    • pp.567-574
    • /
    • 2011
  • Aluminum extruded panels are widely used instead of corrugated steel panels for weight reduction in high-speed trains. Of the layers in the train body, it makes the largest contribution to the sound insulation. However, compared with that of a flat panel with the same weight, the TL of the aluminum extruded panel is remarkably lower in the local resonance frequency band. We study aluminum extruded panels for next-generation 400-km/h trains. We investigate the problem of sound insulation and propose a practical method to improve the sound-insulation performance. The local resonance frequency region is increased by a modification of the core structure, and urethane foam is placed in the core. The effect on the sound insulation is verified by experiments. Finally, the improvement for the entire sound-transmission loss is estimated for the layered floor panels of express trains.

Use of Magnetic Resonance Imaging for Evaluating Residual Breast Tissue After Robotic-Assisted Nipple-Sparing Mastectomy in Women With Early Breast Cancer

  • Wen-Pei Wu;Hung-Wen Lai;Chiung-Ying Liao;Joseph Lin;Hsin-I Huang;Shou-Tung Chen;Chen-Te Chou;Dar-Ren Chen
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.640-646
    • /
    • 2023
  • Objective: Prospective studies on postoperative residual breast tissue (RBT) after robotic-assisted nipple-sparing mastectomy (R-NSM) for breast cancer are limited. RBT presents an unknown risk of local recurrence or the development of new cancer after curative or risk-reducing mastectomies. This study investigated the technical feasibility of using magnetic resonance imaging (MRI) to evaluate RBT after R-NSM in women with breast cancer. Materials and Methods: In this prospective pilot study, 105 patients, who underwent R-NSM for breast cancer at Changhua Christian Hospital between March 2017 and May 2022, were subjected to postoperative breast MRI to evaluate the presence and location of RBT. The postoperative MRI scans of 43 patients (age, 47.8 ± 8.5 years), with existing preoperative MRI scans, were evaluated for the presence and location of RBT. In total, 54 R-NSM procedures were performed. In parallel, we reviewed the literature on RBT after nipple-sparing mastectomy, considering its prevalence. Results: RBT was detected in 7 (13.0%) of the 54 mastectomies (6 of the 48 therapeutic mastectomies and 1 of the 6 prophylactic mastectomies). The most common location for RBT was behind the nipple-areolar complex (5 of 7 [71.4%]). Another RBT was found in the upper inner quadrant (2 of 7 [28.6%]). Among the six patients who underwent RBT after therapeutic mastectomies, one patient developed a local recurrence of the skin flap. The other five patients with RBT after therapeutic mastectomies remained disease-free. Conclusion: R-NSM, a surgical innovation, does not seem to increase the prevalence of RBT, and breast MRI showed feasibility as a noninvasive imaging tool for evaluating the presence and location of RBT.

27Al and 87Rb Nuclear Magnetic Resonance Study of the Relaxation Mechanisms of RbAl(CrO4)2·2H2O Single Crystals

  • Kim, Jae Sung;Lim, Ae Ran
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.16 no.2
    • /
    • pp.111-121
    • /
    • 2012
  • The spin-lattice relaxation times, $T_1$, and spin-spin relaxation times, $T_2$, of the $^{27}Al$ and $^{87}Rb$ nuclei in $RbAl(CrO_4)_2{\cdot}2H_2O$ crystals were investigated. The presence of only one resonance line for the $^{27}Al$ nuclei indicates that the results in a dynamical averaging of the crystal electric field that produces a cubic symmetry field. The changes in the temperature dependence of $T_1$ are related to variations in the symmetry of the octahedra of water molecules surrounding $Al^+$ and $Rb^+$. The $T_1$ values for the $^{27}Al$ and $^{87}Rb$ nuclei are different due to differences in the local environments of these ions. We also compared these $^{27}Al$ and $^{87}Rb$ NMR results with those obtained for $RbAl(CrO_4)_2{\cdot}2H_2O$ crystals. The relaxation mechanisms of $RbAl(XO_4)_2{\cdot}nH_2O$ (X=Cr and S) crystals are characterized by completely different NMR behaviors.

Primary Malignant Melanoma in the Pineal Region

  • Park, Jae-Hyun;Hong, Yong-Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.6
    • /
    • pp.504-508
    • /
    • 2014
  • A 59-year-old male patient had 5-month history of gait disturbance and memory impairment. His initial brain computed tomography scan showed $3.5{\times}2.8cm$ sized mass with high density in the pineal region. The tumor was hypointense on T2 weighted magnetic resonance images and hyperintense on T1 weighted magnetic resonance images with heterogenous enhancement of central portion. The tumor was totally removed via the occipital transtentorial approach. Black mass was observed in the operation field, and after surgery, histopathological examination confirmed the diagnosis of malignant melanoma. Whole spine magnetic resonance images and whole body 18-fluoro-deoxyglucose positron emission tomography could not demonstrate the primary site of this melanoma. Scrupulous physical examination of his skin and mucosa was done and dark pigmented lesion on his left leg was found, but additional studies including magnetic resonance images and skin biopsy showed negative finding. As a result, final diagnosis of primary pineal malignant melanoma was made. He underwent treatment with the whole brain radiotherapy and extended local boost irradiation without chemotherapy. His preoperative symptoms were disappeared, and no other specific neurological deficits were founded. His follow-up image studies showed no recurrence or distant metastasis until 26 weeks after surgery. Primary pineal malignant melanomas are extremely rare intracranial tumors, and only 17 cases have been reported since 1899. The most recent case report showed favorable outcome by subtotal tumor resection followed by whole brain and extended local irradiation without chemotherapy. Our case is another result to prove that total tumor resection with radiotherapy can be the current optimal treatment for primary malignant melanoma in the pineal region.

Analysis of Ride Comfort for an Automobile with flexible Vehicle Body (차체의 유연성을 고려한 차량 승차감 해석)

  • Kim Junghoon;Choi Kwangsung;Park Sungyong;Lee Jangmoo;Kang Sangwook;Kang Juseok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.4
    • /
    • pp.121-128
    • /
    • 2005
  • In most researches on the ride comfort analysis of passenger vehicles, the flexibility of the vehicle body has been not considered as an important factor, because the resonance frequencies of the vehicle body related to pitching, yawing and rolling motions are below 10Hz while the resonance frequencies of the vehicle body related to the flexibility are above 20Hz approximately. Nevertheless, the paper shows that the consideration of the local flexibility (or local stiffness) of the 4 corners on which shock absorbers are mounted influences the ride comfort. A simple beam model is devised to qualitatively examine the effect of the change of the local stiffness of the vehicle body on the ride comfort. Based on the results obtained from the analysis of the one-dimensional model, multi-body dynamic analysis considering the flexibility of the vehicle body is performed using ADAMS and MSC/NASTRAN. Natural frequencies and mode shapes computed by MSC/NASTRAN are used as input data for multi-body dynamic analysis in ADAMS. Through simulations using ADAMS, it has been found that the ride comfort can be improved by changing the local stiffness of the vehicle body and that the simulation results agree with experiment results.