• Title/Summary/Keyword: local resonance

Search Result 287, Processing Time 0.03 seconds

Context-Dependent Classification of Multi-Echo MRI Using Bayes Compound Decision Model (Bayes의 복합 의사결정모델을 이용한 다중에코 자기공명영상의 context-dependent 분류)

  • 전준철;권수일
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.179-187
    • /
    • 1999
  • Purpose : This paper introduces a computationally inexpensive context-dependent classification of multi-echo MRI with Bayes compound decision model. In order to produce accurate region segmentation especially in homogeneous area and along boundaries of the regions, we propose a classification method that uses contextual information of local enighborhood system in the image. Material and Methods : The performance of the context free classifier over a statistically heterogeneous image can be improved if the local stationary regions in the image are disassociated from each other through the mechanism of the interaction parameters defined at he local neighborhood level. In order to improve the classification accuracy, we use the contextual information which resolves ambiguities in the class assignment of a pattern based on the labels of the neighboring patterns in classifying the image. Since the data immediately surrounding a given pixel is intimately associated with this given pixel., then if the true nature of the surrounding pixel is known this can be used to extract the true nature of the given pixel. The proposed context-dependent compound decision model uses the compound Bayes decision rule with the contextual information. As for the contextual information in the model, the directional transition probabilities estimated from the local neighborhood system are used for the interaction parameters. Results : The context-dependent classification paradigm with compound Bayesian model for multi-echo MR images is developed. Compared to context free classification which does not consider contextual information, context-dependent classifier show improved classification results especially in homogeneous and along boundaries of regions since contextual information is used during the classification. Conclusion : We introduce a new paradigm to classify multi-echo MRI using clustering analysis and Bayesian compound decision model to improve the classification results.

  • PDF

Comparison Between Contrast-Enhanced Computed Tomography and Contrast-Enhanced Magnetic Resonance Imaging With Magnetic Resonance Cholangiopancreatography for Resectability Assessment in Extrahepatic Cholangiocarcinoma

  • Jeongin Yoo;Jeong Min Lee;Hyo-Jin Kang;Jae Seok Bae;Sun Kyung Jeon;Jeong Hee Yoon
    • Korean Journal of Radiology
    • /
    • v.24 no.10
    • /
    • pp.983-995
    • /
    • 2023
  • Objective: To compare the diagnostic performance and interobserver agreement between contrast-enhanced computed tomography (CECT) and contrast-enhanced magnetic resonance imaging (CE-MRI) with magnetic resonance cholangiopancreatography (MRCP) for evaluating the resectability in patients with extrahepatic cholangiocarcinoma (eCCA). Materials and Methods: This retrospective study included treatment-naïve patients with pathologically confirmed eCCA, who underwent both CECT and CE-MRI with MRCP using extracellular contrast media between January 2015 and December 2020. Among the 214 patients (146 males; mean age ± standard deviation, 68 ± 9 years) included, 121 (56.5%) had perihilar cholangiocarcinoma. R0 resection was achieved in 108 of the 153 (70.6%) patients who underwent curative-intent surgery. Four fellowship-trained radiologists independently reviewed the findings of both CECT and CE-MRI with MRCP to assess the local tumor extent and distant metastasis for determining resectability. The pooled area under the receiver operating characteristic curve (AUC), sensitivity, and specificity of CECT and CE-MRI with MRCP were compared using clinical, surgical, and pathological findings as reference standards. The interobserver agreement of resectability was evaluated using Fleiss kappa (κ). Results: No significant differences were observed between CECT and CE-MRI with MRCP in the pooled AUC (0.753 vs. 0.767), sensitivity (84.7% [366/432] vs. 90.3% [390/432]), and specificity (52.6% [223/424] vs. 51.4% [218/424]) (P > 0.05 for all). The AUC for determining resectability was higher when CECT and CE-MRI with MRCP were reviewed together than when CECT was reviewed alone in patients with discrepancies between the imaging modalities or with indeterminate resectability (0.798 [0.754-0.841] vs. 0.753 [0.697-0.808], P = 0.014). The interobserver agreement for overall resectability was fair for both CECT (κ = 0.323) and CE-MRI with MRCP (κ = 0.320), without a significant difference (P = 0.884). Conclusion: CECT and CE-MRI with MRCP showed no significant differences in the diagnostic performance and interobserver agreement in determining the resectability in patients with eCCA.

Helical tomotherapy for spine oligometastases from gastrointestinal malignancies

  • Choi, Yun-Seon;Kim, Jun-Won;Lee, Ik-Jae;Han, Hee-Ji;Baek, Jong-Geal;Seong, Jin-Sil
    • Radiation Oncology Journal
    • /
    • v.29 no.4
    • /
    • pp.219-227
    • /
    • 2011
  • Purpose: This study evaluated the treatment effectiveness and proper radiation dose of helical tomotherapy (HT) in spine oligometastases from gastrointestinal cancers. Materials and Methods: From 2006 to 2010, 20 gastrointestinal cancer patients were treated with HT for spine oligometastases (31 spine lesions). The gross tumor volume (GTV) was the tumor evident from magnetic resonance imaging images fused with simulation computed tomography images. Clinical target volume (CTV) encompassed involved vertebral bodies or dorsal elements. We assumed that the planning target volume was equal to the CTV. We assessed local control rate after HT for 31 spine metastases. Pain response was scored by using a numeric pain intensity scale (NPIS, from 0 to 10). Results: Spine metastatic lesions were treated with median dose of 40 Gy (range, 24 to 51 Gy) and median 5 Gy per fraction (range, 2.5 to 8 Gy) to GTV with median 8 fractions (range, 3 to 20 fraction). Median biologically equivalent dose (BED, ${\alpha}/{\beta}$ = 10 Gy) was 52 $Gy_{10}$ (range, 37.5 to 76.8 $Gy_{10}$) to GTV. Six month local control rate for spine metastasis was 90.3%. Overall infield failure rate was 15% and outfield failure rate was 75%. Most patients showed pain relief after HT (93.8%). Median local recurrence free survival was 3 months. BED over 57 $Gy_{10}$ and oligometastases were identified as prognostic factors associated with improved local progression free survival (p = 0.012, P = 0.041). Conclusion: HT was capable of delivering higher BED to metastatic lesions in close proximity of the spinal cord. Spine metastases from gastrointestinal tumors were sensitive to high dose radiation, and BED (${\alpha}/{\beta}$ = 10 Gy) higher than 57 $Gy_{10}$ could improve local control.

Radiological Recurrence Patterns after Bevacizumab Treatment of Recurrent High-Grade Glioma: A Systematic Review and Meta-Analysis

  • Se Jin Cho;Ho Sung Kim;Chong Hyun Suh;Ji Eun Park
    • Korean Journal of Radiology
    • /
    • v.21 no.7
    • /
    • pp.908-918
    • /
    • 2020
  • Objective: To categorize the radiological patterns of recurrence after bevacizumab treatment and to derive the pooled proportions of patients with recurrent malignant glioma showing the different radiological patterns. Materials and Methods: A systematic literature search in the Ovid-MEDLINE and EMBASE databases was performed to identify studies reporting radiological recurrence patterns in patients with recurrent malignant glioma after bevacizumab treatment failure until April 10, 2019. The pooled proportions according to radiological recurrence patterns (geographically local versus non-local recurrence) and predominant tumor portions (enhancing tumor versus non-enhancing tumor) after bevacizumab treatment were calculated. Subgroup and meta-regression analyses were also performed. Results: The systematic review and meta-analysis included 17 articles. The pooled proportions were 38.3% (95% confidence interval [CI], 30.6-46.1%) for a geographical radiologic pattern of non-local recurrence and 34.2% (95% CI, 27.3-41.5%) for a non-enhancing tumor-predominant recurrence pattern. In the subgroup analysis, the pooled proportion of non-local recurrence in the patients treated with bevacizumab only was slightly higher than that in patients treated with the combination with cytotoxic chemotherapy (34.9% [95% CI, 22.8-49.4%] versus 22.5% [95% CI, 9.5-44.6%]). Conclusion: A substantial proportion of high-grade glioma patients show non-local or non-enhancing radiologic patterns of recurrence after bevacizumab treatment, which may provide insight into surrogate endpoints for treatment failure in clinical trials of recurrent high-grade glioma.

Measurement of Local Elastic Properties of Flip-chip Bump Materials using Contact Resonance Force Microscopy (접촉 공진 힘 현미경 기술을 이용한 플립 칩 범프 재료의 국부 탄성계수 측정)

  • Kim, Dae-Hyun;Ahn, Hyo-Sok;Hahn, Junhee
    • Tribology and Lubricants
    • /
    • v.28 no.4
    • /
    • pp.173-177
    • /
    • 2012
  • We used contact resonance force microscopy (CRFM) technique to determine the quantitative elastic properties of multiple materials integrated on the sub micrometer scale. The CRFM approach measures the frequencies of an AFM cantilever's first two flexural resonances while in contact with a material. The plain strain modulus of an unknown or test material can be obtained by comparing the resonant spectrum of the test material to that of a reference material. In this study we examined the following bumping materials for flip chip by using copper electrode as a reference material: NiP, Solder (Sn-Au-Cu alloy) and under filled epoxy. Data were analyzed by conventional beam dynamics and contact dynamics. The results showed a good agreement (~15% difference) with corresponding values determined by nanoindentaion. These results provide insight into the use of CRFM methods to attain reliable and accurate measurements of elastic properties of materials on the nanoscale.

Intraosseous neurofibroma of the mandible involving masticator space (저작근 공간을 침범한 하악골내 신경섬유종)

  • Kim, Eun-Kyung;Han, Won-Jeong;Choi, Jin-Woo;Kim, Hak-Sun
    • The Journal of the Korean dental association
    • /
    • v.58 no.9
    • /
    • pp.556-562
    • /
    • 2020
  • Neurofibroma is a benign, heterogenous peripheral nerve sheath tumor arising from the connective tissue of peripheral nerve sheaths, especially the endoneurium. Its intraoral occurrence is uncommon and its occurrence within mandible is extremely rare. A case of solitary intraosseous neurofibroma of the mandible involving masticator space in a 8-year-old male is reported. He was referred from a private local clinic with a chief complaint of limitation in opening of the mouth. Panoramic and cone-beam computed tomographic images showed unilocular radiolucent lesion with scalloped border at the right mandibular ramus, connected posteriorly to the enlarged mandibular foramen and anteriorly to the mandibular canal. T1-weighted magnetic resonance images showed soft tissue mass of isointensity compared with muscles. Contrast-enhanced T1-weighted images showed peripheral enhancement and T2-weighted images showed the heterogeneous hyperintense mass with extension between lateral and medial pterygoid muscles. The tumor was surgically removed under general anesthesia and diagnosed to be neurofibroma at the biopsy.

  • PDF

Metastasis of Intracranial Hemangiopericytoma to Thoracic Spine - Case Report - (두개강내 혈관주위세포종의 흉추로의 전이 - 증례보고 -)

  • Oh, Jun Gyu;Kim, Joo Seung;Moon, Byung Gwan;Kang, Hee In;Lee, Seung Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.5
    • /
    • pp.666-669
    • /
    • 2001
  • We report a case of meningeal hemangiopericytoma presenting as metastasis in the vertebral body and pedicle of the thoracic spine. Hemangiopericytoma is a rare vascular neoplasm. Although the tumor has a strong propensity for both local recurrence and extracranial metastasis, metastasis to thoracic spine is very rare and only two cases were found in the literature. A 44-year-old woman with paraparesis and pain in the thoracic and lower legs was examined by plain radiographs and magnetic resonance imaging. The intracranial hemangiopericytoma was operated 3 years ago. Magnetic resonance imaging demonstrated a tumor invading the left vertebral body and pedicle of the 11th thoracic spine, and compressing the dural sac. The patient was gradually improved after surgical removal of the lesions and the histologic findings were characteristics of hemangiopericytoma.

  • PDF

Dynamics of the mobile insert helix in the domain III-IV of Aux/IAA17 probed by site-directed spin labeling and paramagnetic NMR spectroscopy

  • Han, Mookyoung;Suh, Jeong-Yong
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.2
    • /
    • pp.61-66
    • /
    • 2015
  • The plant hormone auxin is involved in all stages of plant development. Aux/IAAs are the transcriptional repressors that bind to the Auxin Response Factors (ARFs) to regulate the gene expression upon auxin release. Aux/IAA have highly conserved C-terminal domains (domains III-IV) that mediate both homotypic and heterotypic interactions between Aux/IAA and ARF family proteins. Recent studies revealed that the conserved domains III-IV share a common ${\beta}$-grasp fold that oligomerizes in a front-to-back manner. In particular, Aux/IAA contains a mobile insert helix in the domain III-IV, whereas ARFs do not. Here, we investigated the dynamics of the insert helix using paramagnetic NMR spectroscopy. The insert helix exhibited fast motions in the ps-ns time scale from $^{15}N$ relaxation data, but the amplitude of the motion is likely limited to the local neighborhood. Our result suggests that the motion of the helix may have functional implications in protein-protein interactions for transcriptional regulations.

A study on the design of a K-band harmonic oscillator using voltage controlled dielectric resonance (전압제어 유전체공진을 이용한 K-대역 발진기 설계에 관한 연구)

  • 전순익;김성철;은도현;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.12
    • /
    • pp.3215-3226
    • /
    • 1996
  • In this paper a K-band harmonic oscillator competitive to ordinary Push-Push type oscillators is introduced. This oscillator is composed of two-X-band dielectric resonance circuits. To favor its harmonic generation, the load effect and the bias effect are studied to allow the maximum harmonic distortion. As results, the dielectric resonated load and the class A bias are used for the 2nd harmonic generation. analytical study for modelling of voltage controlled dielectric resonator is carried out with theoretical background. The performance of the circuit is evaluated by simulation using harmonic balanced method. The novel structure has ont only a voltage tuning circuit but also an output port at fundamental frequency as the function of prescaler for phase lockede loop application on the just single oscillation structure. In experimentation, the output freqneyc of the 2nd harmonic signal is 20.5GHz and the maximum power level of output is +5.5dBm without additional post amplifiers. the harmonic oscillator exhibits -30dBc of high fundamental frequency rejection without added extra filters. The phase noise of -90dBc/Hz at 100kHz off-carrier has been achieved under free running condition, that satisfies phase noise requirement of IESS 308. The proposed oscillator may be utilized as the clean and stable fixed local oscillator in Transmit Block Upconvertor(TBU) or Low oise Block downconvertor(LNB) for K/Ka-band digital communications and satellite broadcastings.

  • PDF

Design and Implementation of Internal Multiband Loop Embedded Monopole Antenna for Mobile Handset

  • Jung, Pil Hyun;Yang, Cheol Yong;Lee, Seong Ha;Yang, Woon Geun
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.484-491
    • /
    • 2013
  • In this paper, we proposed an internal multiband loop embedded monopole antenna for mobile handset that could be used for smart phones. The proposed antenna has a volume of 40 mm(W) ${\times}$ 15 mm(L) ${\times}$ 5 mm(H), ground plane size is 40 mm(W) ${\times}$ 80 mm(L), and covers the GSM900 (Global System for Mobile communications : 880-960 MHz), K-PCS (Korea-Personal Communications Service : 1750-1870 MHz), US-PCS (US Personal Communications Service : 1850-1990 MHz), WCDMA (Wideband Code Division Multiple Access : 1920-2170 MHz), Wibro (2300-2390 MHz), Bluetooth (2400-2483 MHz) and WLAN (Wireless Local Area Network : 2400-2483.5 MHz) bands for VSWR (voltage standing wave ration) less than 3. The proposed loop adding design at middle section of longest branch showed wide impedance bandwidth for the lowest resonance frequency band. The proposed antenna have a lowest resonance frequency band from 738 MHz to 1075 MHz for S11 value of -6dB. A HFSS (High Frequency Structure Simulator) of the Ansys Corporation based on a finite element method is employed to analyze the proposed antenna in the design process and to compare the simulation and experimental results.