• 제목/요약/키워드: local loop

Search Result 261, Processing Time 0.031 seconds

An Influence of Groundwater Flow on Performance of Closed Borehole Heat Exchangers (Part-1) (지하수류가 밀폐형 천공 지중열교환기 성능에 미치는 영향(1))

  • Hahn, Jeong Sang;Hahn, Chan;Yoon, Yun Sang;Kiem, Young Seek
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.3
    • /
    • pp.64-81
    • /
    • 2016
  • To analyze the influence of various groundwater flow rates (specific discharge) on BHE system with balanced and unbalanced energy loads under assuming same initial temperature (15℃) of ground and groundwater, numerical modeling using FEFLOW was used for this study. When groundwater flow is increased from 1 × 10−7 to 4 × 10−7m/s under balanced energy load, the performance of BHE system is improved about 26.7% in summer and 22.7% at winter time in a single BHE case as well as about 12.0~18.6% in summer and 7.6~8.7% in winter time depending on the number of boreholes in the grid, their array type, and bore hole separation in multiple BHE system case. In other words, the performance of BHE system is improved due to lower avT in summer and higher avT in winter time when groundwater flow becomes larger. On the contrary it is decreased owing to higher avT in summer and lower avT in winter time when the numbers of BHEs in an array are increased, Geothermal plume created at down-gradient area by groundwater flow is relatively small in balanced load condition while quite large in unbalanced load condition. Groundwater flow enhances in general the thermal efficiency by transferring heat away from the BHEs. Therefore it is highly required to obtain and to use adequate informations on hydrogeologic characterristics (K, S, hydraulic gradient, seasonal variation of groundwater temperature and water level) along with integrating groundwater flow and also hydrogeothermal properties (thermal conductivity, seasonal variation of ground temperatures etc.) of the relevant area for achieving the optimal design of BHE system.

A New Decision-Directed Carrier Recovery Algorithm (새로운 결정지향 반송파 복원 알고리즘)

  • 고성찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7A
    • /
    • pp.1028-1035
    • /
    • 1999
  • To increase the throughput of data transmission in burst-mode TDMA communication systems and also to get a good BER performance at the same time, it is essential to rapidly acquire the carrier while keeping the desirable tracking performance. To achieve this goal, in this paper, a new decision-directed carrier recovery algorithm is presented. The proposed scheme does not incorporate the PLL and suppress the Gaussian random process of input noise by the pre-stage low pass filter so as to get both the fast acquisition and a good performance. Through computer simulations, the performance of the scheme is analyzed with respect to the acquisition time and bit error rate. The cycle slip in the proposed scheme is seldom observed at very low SNR environment in contrast to the previous proposed one. Because of this merit, it is not required to do the differential encoding and decoding in the proposed scheme.

  • PDF

Capacity esitmation of microcell in macro/microcell overlaid W-CDMA WLL system (매크로셀과 마이크로셀이 중첩된 W-CDMA 무선가입자망에서 마이크로셀의 용량 산정)

  • 손성찬;노재성;김수용;조성준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2153-2164
    • /
    • 1998
  • This paper has presented the parameters for the coexistence between two systems in macro/microcell ovelaid W-CDMA WLL (wideband CDMA wireless local loop) and has calculated the capacity of forward/reverse link in microcell. To produce the capacity for analyzing system interference effects, we have shown tables and graphs with the parameters sucyh as RF channel bandwidth of WLL(W), the transmission rate of service message(R), the required signal power to noise power ratio( $E_{b/}$ $N_{0}$) for achieving accepatable error rate, te user number ( $N_{W1}$, $N_{W2}$) of the neighboring system, the signal power to interference power ratio(.GAMMA.$_{C1B}$, .GAMMA.$_{C2B}$) of the neighboring system, the normalized distance(d) between microcell and macrocell base-station, and microcell to macrocell radius ratio ( $R_{d}$). From the results, we have convinced that the capacity of microcell diminishes as increasing the user number ( $N_{W2}$) in macrocell, increasing the microcell radius, and decreasing the normalized distance(d) between microcell and macrocell base-station. Especially, we have known that when $R_{d}$=0.1, $N_{W2}$ must be below 24 at .GAMMA.$_{C2B}$ = 0 dB and below 8 at .GAMMA.$_{C2B}$ = 4 dB for the acceptable capacity raito to be over 80%. Therfore, this paper is usefult to design microcell W-CDMA WLL for accommodating more user number under the interference effects of macrocell W-CDMA WLL and is expected to be reference in power control if base-station.ation.ion.ation.ation.

  • PDF

Overcoming OBI Problem by Means of Heterodyne Detection in Upstream Transmission of WDM/SCM-PON (WDM/SCM-PON의 상향 전송에서 헤테로다인 방식을 이용한 광간섭잡음 문제 극복방안 연구)

  • Jeon, You-Chan;Shin, Hong-Seok;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2A
    • /
    • pp.202-208
    • /
    • 2010
  • The performance of upstream transmission in SCM-PON is generally limited by the presence of OBI which is caused by the beating of two or more lasers. In this paper, we propose a novel approach for reducing OBI problem by using heterodyne detection with an additional LD as a local oscillator, resulting that the RF signal is shifted to the other spectal band. In addition, it is possible that the proposed method can provide the cost-effective solution thanks to the loop-back mechanism using R-SOA in ONUs. The performance is superior when the spectral width of LD is smaller and the power difference between the transmission LD and the oscillation LD is bigger. System configuration and design consideration are discussed. Performance of the systems is evaluated by simulator called OptSim. It is expected to provide WDM/SCM-PON system not only cost-effective but also efficient in increasing the number of subscribers.

Topical Formulation and Antimicrobial Activity of Ketonic Fraction from Leptospermum scoparium (Leptospermum scoparium의 케톤체 분획물을 함유한 외용제제의 항균력)

  • Kim, Eun-Hee;Hwang, Sung-Joo;Park, Song-Hee;Park, Seung-Youg;Rhee, Gye-Ju
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.3
    • /
    • pp.151-158
    • /
    • 2000
  • Gel and cream containing 5% and 10% ketonic fraction (KF) of Leptospermum scoparium, respectively were formulated. Antimicrobial activity, stability, anti-inflammatory effect, rheological properties, drug release and acute toxicity for these topical efficacy were evaluated. Gel and cream containing neomycin or gentamycin in combination with KF has potent antimicrobial activity. Gel and cream were physically stable and did not show any creaming for 6 months storage. Gel showed plastic flow with yield value and cream showed pseudoplastic flow with hysteresis loop. The gel and cream containing KF showed higher viscosity than control or commercial one. The viscosity increased as the concentration of KF increased. Both 10% gel and cream showed a significant decrease in swelling when applied to the carrageenan- injected paw, suggesting local antiinflammatory activity. Particularly, 10% gel preparation showed similar antiinflammatory activity when compared with commercially available drugs. Percent of drug released and diffusion coefficient were in the order of 5% gel, 10% gel, 5% cream, and 10% cream, respectively. There were no significant changes of body weight in rats percutaneously administered with 10% cream and gel when compared with control. There were no induced acute toxicity when 10% cream or gel was applied to rats. Leptospermum scoparium could be practicaly used in topical preparations.

  • PDF

A 3 Stage MMIC Low Noise Amplifier for the Ka Band Satellite Communications and BWLL System (Ka 대역 위성통신 및 BWLL 시스템용 3단 MMIC 저잡음 증폭기 설계 및 제작)

  • 염인복;정진철;이성팔
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.71-76
    • /
    • 2001
  • A Ka Band 3-stage MMIC (Monolithic Microwave Integrated Circuits) LNA (Low Noise Amplifiers) has been designed and fabricated far the Ka band satellite communications and BWLL(Broad Band Wireless Local Loop)system. The MMIC LNA consists of two single-ended type amplification stages and one balanced type amplification stage to satisfy noise figure, high gain and amplitude linearity. The 0.15${\mu}{\textrm}{m}$ pHEMT has been used to provide a ultra low noise figure and high gain amplification. Series and Shunt feedback circuits and λ/4 short lines were inserted to ensure high stability over the frequency range form DC to 80 GHz. The size of the MMIC LNA is 3.1mm$\times$2.4mm(7.44mm$^2$). The on wafer measured performance of the MMIC LNA, which agreed with the designed performance, showed the noise figure of less than 2.0 dB, and the gain of more than 26 dB, over frequency ranges from 22 GHz to 30 GHz.

  • PDF

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

Stereo image compression based on error concealment for 3D television (3차원 텔레비전을 위한 에러 은닉 기반 스테레오 영상 압축)

  • Bak, Sungchul;Sim, Donggyu;Namkung, Jae-Chan;Oh, Seoung-jun
    • Journal of Broadcast Engineering
    • /
    • v.10 no.3
    • /
    • pp.286-296
    • /
    • 2005
  • This paper presents a stereo-based image compression and transmission system for 3D realistic television. In the proposed system, a disparity map is extracted from an input stereo image pair and the extracted disparity map and one of two input images are transmitted or stored at a local or remote site. However, correspondences can not be determined in occlusion areas. Thus, it is not easy to recover 3D information in such regions. In this paper, a reconstruction image compensation algorithm based on error block concealment and in-loop filtering is proposed to minimize the reconstruction error in generating stereo image pair. The effectiveness of the proposed algorithm is shown in term of objective accuracy of reconstruction image with several real stereo image pairs.

Blood Flow Changes by Anastomotic Method in Fontan Operation (폰탄 수술에서 문합방법에 따른 혈류 변화)

  • Kim, S.H.;Park, Y.H.;Cho, B.K.;Kim, J.H.;Hong, Y.S.;Kim, Y.H.;Kim, S.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.203-206
    • /
    • 1996
  • To understand the local fluid dynamics for different desists of Fontan operation, five models were made out of Pyrex glass to facilitate in-vitro study. Model I, II and III have same position of the center of the anastomosis of the IVC( inferior vena cava) with that of the SVC(superior vena cava), but Model IV and V have 10 mm offset between them. Also the anastomotic junction angles are different(Model I and $IV:90^{\circ}$, Model II and $V:70^{\circ}$, Model $III:45^{\circ}$). These models were then connected to a flow loop for flow visualization study. In Model I any dominant vortex was not seen in the central region of the juntion, but a large unstable vortex was created in the Model II and III. In Model IV and V a significant stagnation region was created in the middle of the offset region. It also showed that the flow direction from the IVC and SVC to the LPA(left pulmonary artery) and RPA(right pulmonary artery) highly depends on the offset of the junction rather than the anastomotic junction angle.

  • PDF

New Method for Vehicle Detection Using Hough Transform (HOUGH 변환을 이용한 차량 검지 기술 개발을 위한 모형)

  • Kim, Dae-Hyon
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.1
    • /
    • pp.105-112
    • /
    • 1999
  • Image Processing Technique has been used as an efficient method to collect traffic information on the road such as vehicle counts, speed, queues, congestion and incidents. Most of the current methods which have been used to detect vehicles by the image processing are based on point processing, dealing with the local gray level of each pixel in the small window. However, these methods have some drawbacks. Firstly, detection is restricted by image quality. Secondly, they can not deal with occlusion and perspective projection problems, In this research, a new method which possibly deals with occlusion and perspective problems will be proposed. It extracts spatial information such as the position, the relationship of vehicles in 3-dimensional space, as well as vehicle detection in the image. The main algorithm used in this research is based on an extension of the Hough Transform. The Hough Transform which is proposed to estimates parameters of vertices and directed edges analytically on the Hough Space, is a valuable method for the 3-dimensional analysis of static scenes, motion detection and the estimation of viewing parameters.

  • PDF