• Title/Summary/Keyword: local exhaust ventilation

Search Result 74, Processing Time 0.022 seconds

On-site Application of a Vehicle Tunnel Ventilation Simulator (도로터널 환기시뮬레이션 모델 현장적용 연구)

  • 이창우;김효규
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.319-327
    • /
    • 2001
  • Introduction of new design tools has been required to optimally design and operate the ventilation system of long vehicle tunnels.. The demand has led to wide spread use of the simulation technique throughout the would to analysis the dynamic relationship among the variables associated with vehicle tunnel ventilation. This paper aims at performing on-site study at local tunnels to test the applicability of NETVEN, a simulation model vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels model of vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels employing different ventilation systems as well as traffic methods. There were some discrepancies sound between the simulation output and measurements and the following four factors are considered to mainly cause those disagreement. (1) The real situation shows distinctive transient and retarding characteristics with respect to air flow and contaminant dispersion, while ventilation forces are not steady-state and in particular those traffic and climatic variables show significant instantaneous variation. (3) Near the exit portal, the CO levels show bigger differences. The general trend is that data with higher CO concentrations carry bigger discrepancies. Turbulent diffusion is though to be the main reason for it and also contribute to the fact hat the highest CO concentrations are found at the locations somewhat inward, not at the exit portals. (4) Higher traffic rate results in higher discrepancies of ventilation velocity. Along with the exhaust characteristics, the vehicle aerodynamic characteristics need to be studied continuously in order to reduce the velocity disagreement.

  • PDF

Evaluation of Chromium and Manganese Exposure in Welders and Establishment of Efficient Preventive Measures for Fume Exposure (철강용접자의 크롬 및 망간 노출평가와 산업위생관리 대책에 관한 연구)

  • Lee, Young-Sei;Yoon, Chong-Guk;Park, Jong-An;Lee, Song-Kwon;Chae, Jong-Hong;Kim, Ek-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.45-57
    • /
    • 2000
  • Results of environmental monitoring for 35 steel industry welders exposed to manganese and chromium fume were evaluated. Efficiency of respiratory protectors, welding face shields and local exhaust ventilation were also evaluated to establish more efficient preventive measures that can protect welders from occupational disease as related to welding fume. The results are as follows; 1. Total fume from $CO_2$ arc welding with mild steel occurred 1.5 to 2.2 times more than that from shielded metal arc welding. Chromium and nickel fume from welding with stainless steel occurred 27 to 59 times and 18 to 30 times, respectively, than those with mild steel. 2. Proportions of water-soluble chromium(VI) and insoluble chromium(VI) Compare to total chromium occurring from $CO_2$ arc welding with stainless steel were 10.5% and 8.7%, respectively, while those with mild steel were 57.1 to 63.2% and 31.6 to 38.1%, respectively. 3. The efficiencies of 4 types of respiratory protectors to reduce welding fume exposure were evaluated as 54.4 to 64.4%. 4. The reducing effect of head type welding face shield was 67.6%, and that of hand type welding face shield was 58.5%. The highest reducing effect was shown in air supply welding face shield as 99.2%, although it is not convenient to wear. 5. When welding face shield and respiratory protectors were worn together, the reducing efficiency increased to 79.0 to 87.5%. 6. When local exhaust ventilation was installed in workplace, the reducing efficiencies varied from 31.5 to 73.1% according to the types of welding.

  • PDF

A Study on Improvement of Inhalation Efficiency of Hood in Ventilation System for Elimination of Industrial Dust (산업용 분진 제거를 위한 배기장치 내 후드의 흡입성능 개선에 관한 연구)

  • Yang, Ho-Dong;Oh, Yool-Kwon
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • The present study investigates on improvement of inhalation efficiency of hood in ventilation system for elimination of industrial dust. The hood, one of local exhaust ventilation system, has an important function to inhale a pollution source such as harmful dust and industrial waste. In this study, in order to improve the inhalation efficiency of the industrial hood, a new device named "gas-guide-device" was attached to inside of hood. The thermal fluid commercial code "Phoenics ver 3.1" was used to analyze the flow velocity distribution at the hood inlet and around the hood after gas-guide-device was installed. And the flow velocity on each position inside and around the hood was actually measured using the hot wire type anemometer under the same condition as that of numerical analysis. Also, in order to identify the optimum shape of gas-guide-device, numerical analysis and experiments are performed under various conditions and their results are presented. The results of this study revealed that the hood attached with gas-guide-device was higher the inhalation efficiency than that for without one and can be possible to improve the capture velocity of the industrial dust. And the optimum shape of gas-guide-device was identified that the ratio of two sizes of gas-guide-device, X to Y, has 4 to 6 on the basis of the hood size in use and the width (b) of gas-guide-device.

A Study on Improvement of Ventilation Efficiency of Multi-Stage Slot Hood (외부식 다단형 슬로트 후드의 효율 향상에 관한 연구)

  • Kim, Hyun Seok;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.2
    • /
    • pp.204-212
    • /
    • 1993
  • This study was conducted to evaluate ventilation efficiency of 4-stage slot hood by variation of slot width, flow rate, hood size and baffle size. The slot velocity, control velocity and plenum velocity were related to slot width and the distance between source of contamination and hood. The results obtained from laboratory experiment for local exhaust ventilation systems were as follows ; 1. When slot widths were constant(equally changed) and the velocity was 6-10 m/s, the slot velocity from 1st slot to 4th slot gradually decreased. As the slot width-to-slot length ratio(WLR) decreased, the slot velocity of each stage increased. But if WLR value was less than 0.04, the slot velocity decreased. 2. When slot velocity exceeded 10 m/s with constant slot widths, the slot velocity of each stage was uniform. 3. When the slot velocity was uniform within 10 m/s and the first slot width was 14-20 mm, the slot width ratio between 1st slot and each of three other slots were 1, 1.25, 1.5 and 3.0, respectively. 4. The slot and plenum velocity were uniform when exhaust flow rate changed from 14 to $19m^3/min$ and there were no hood splitter vanes. 5. When the slot velocity at each stage was uniform, the control velocity at site 30 cm away from hood No.2 increased from 0.15-0.30 to 0.25-0.45 m/s and the control distance from 20 to 30 cm(about 1.5 times).

  • PDF

Health Risk Factors and Ventilation Improvements in Welding Operation at Large-sized Casting Process (대형 주물공정 용접작업장의 건강 위해인자 및 환기 개선)

  • Jung, Jong Hyeon;Jung, Yu Jin;Lee, Sang Man;Lee, Jung Hee;Shon, Byung Hyun;Lim, Hyun Sul
    • Clean Technology
    • /
    • v.20 no.2
    • /
    • pp.171-178
    • /
    • 2014
  • In this study we have examined the health risk factors and analyzing data of laborers working at the welding operation at large-sized casting process. In order to improve the working environment of workplace, an effective ventilation method was proposed after performing CFD (computational fluid dynamics) modeling and measurement of pollutants. As a result of examining the health risk factors of workers, oxidized steel dust is the main pollution source in the company A, welding fume in the companies B and C, and welding fume and oxidized steel dust in the company D. The fume concentration in the workers' breathing zone was $0.05{\sim}4.37mg/m^3$, and the fume concentration in the indoor air at the welding process was $0.13{\sim}7.54mg/m^3$. From a result of CFD, a local exhaust with an exhaust duct adjacent to welding point was found to be most effective in case of the exhaust process. In case of air supply, we found that a desired location of air supply fan would be at the end of the opening. If a standardizing the ventilation system for tunnel-type semi-enclosed space at a large-sized casting process is introduced in welding work places in the future, it would be more effective to protect the health of welding workers working at the casting industry and shipbuilding industry and improve the work environment.

Evaluation of Airflow Control Capability of Natural Ventilators with Various Dampers (자연환기 벤틸레이터의 댐퍼 형태별 환기량 조절능력 평가)

  • Kim, Tae-Hyeong;Ha, Hyun-Chul;Park, Seung-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.364-374
    • /
    • 2006
  • Natural ventilation technique could be the substitute for or the complement to the local exhaust ventilation system in the sense of protecting work environment. Moreover, it has many strong points ; almost no mechanical parts, no energy use and no noise. If applied appropriately, it could have the very high ventilation rate and save a lot of energy expense. But, it depends on the outdoor environment, especially temperature and wind speed/direction. Predicting the capacity of natural ventilation is not an easy job because it comes from both buoyancy and wind effect. Another problem is too much flow through the ventilator especially in winter time due to too much difference between indoor and outdoor temperature. Thus some ventilators in industries are sealed by door or plastic sheet, resulting in bad work environment. Various types of dampers are used to control the flow rate through ventilators. The capabilities of flow control by damper has not been estimated. In addition, it was not tested whether the damper could obstruct the flow through ventilator when fully opened. To answer these questions, 4 types of dampers were tested by using computational fluid dynamics. 10 different configurations includes no damper, full open and half open. Flow rates were estimated and airflow fields were analysed to clarify the before-mentioned questions. The dual type damper was the best choice for controling the capability of ventilator. In addition, the upward grill type damper was the best for not obstructing the air flow when fully opened.

A Study on Worker Exposure to Trichlorethylene and Emission Factor for Degreasers in Plating Plants (중소기업 도금공정에서의 트리클로로에틸렌 폭로와 발산량에 관한 연구)

  • Lee, Keoung Hee;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.3-13
    • /
    • 1993
  • This study was conducted at seven degreasing processes in plating plants located in Seoul, Incheon, Ansan, and Taejeon areas from July 21 to august 27, 1992. This study was performed to assess the TWA exposures to trichloroethylene (TCE) and evaluate factors affecting TCE concentrations in degreasing process. Two-Point Eddy Diffusional Model suggested by Wadden et al. was employed to calculalte emission factors according to degreaser type. Results are summarized as follows. 1. The TWA exposures of the degreasing operators ranged from 1.4 ppm to 123 ppm, and those of three plants out of seven were exceeding 50 ppm of both the Korean and U.S. OSHA standards. Degreasing assistant of Plant B, was exposed to 59 ppm. 2. The average concentrations at the distance 0, 1.5, 3.0 m from the degreasers were 1.014, 24, and 18 ppm, respectively, and showed a signifficant difference by distance (p<0.01). 3. The emission of TCE was reduced by installing local exhaust systems, condensers, and refrigeration lines at the degreasers (p<0.01). 4. The major factors related to exposure of operators were workload (r=.9621. p<0.01) and dimensions of degreansing room(r=-.8667, p<0.05). 5. If the air in degreasing room is mixed violently by other factors in addition to diffusion, the emission factors can not be evaluated because the important hypothesis of the Two-Point Eddy Diffusional Model can not be accepted. 6. The ultrasonic degreaser without the local exhaust ststem, condenser, and refrigeration lines emitted TCE three times greater than the ultrasonic degreaser with condenser and refrigeration 1ines only.

  • PDF

Improvement of hot work environment in the curing processes of a tire manufacturing company (타이어 제조공장 가류공정의 온열환경 개선에 관한 연구)

  • Lim, Jung-ho;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.1
    • /
    • pp.1-10
    • /
    • 2011
  • Generally, the tire curing process is the process in which the sulfur is added and subsequently the tire is heated to give the tire elasticity. In this process, all kinds of the chemicals in the tire are emitted with a lot of heat. The chemical fume and heat aggravate the work environment. To solve this problem, 92 local exhaust ventilators and 8 gravity ventilators were used, but not satisfactory yet. Preliminary survey showed that the temperatures in the process were very high: 30.3, 32.9 and $37.2^{\circ}C$ at 2, 4 and 6m above the ground level, respectively in the winter (outside temperature was $2^{\circ}C$). It can be imagined that the process is severely hot in the summer time. The higher temperature distribution in the higher space tells us that the hot plume could not be removed with the existing ventilation systems. Therefore, in this study, some alternative ventilation systems were designed. The partitions were used to contain the hot plume to increase the capture efficiency. The gravity ventilators were newly designed to improve the extraction efficiency of hot fume. To satisfy the balance of pressure in the curing process, some supply air system was introduced by renewing the existing air conditioning system. Many alternative solutions were evaluated by using computational fluid dynamics modelling. The best and applicable solution was selected and the existing ventilation system was modified. After implementing the new ventilation system, the hot environment was much improved. The temperature reduction in the curing process was about $6.4^{\circ}C$.

Understanding and Application of Stoffenmanager Nano Tool into Synthesis and Packing Process of Nanomaterials (Stoffenmanager nano 컨트롤 밴딩 도구 이해와 나노물질 합성 및 포장 공정 적용 연구)

  • Lee, Naroo;Ahn, Jungho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.95-103
    • /
    • 2015
  • Objectives: This study was conducted in order to better understand the conceptual model and Stoffenmanager nano module and apply it to the synthesis and packing processes of nanomaterials. Methods: Site visits were conducted to five nanomaterial production processes. Product and exposure variables were investigated in these workplaces. Hazard banding and exposure classification of the synthesis and packing processes of nanomaterials were conducted using documents and the website of Stoffenmanager Nano. Results: The five sites featured different products, packing tasks, ventilation and local exhaust, and others. The hazards for nano-nickel and copper were classified as E. The hazards for both fumed silica and indium tin oxide were classified as D. The hazard for spherical silica was classified as C. The exposure classes in the synthesis process of nanomaterials ranged from 2 through 4. The exposure classes in the packing process of nanomaterials ranged from 1 through 4. Conclusions: Application of Stoffenmanager nano to the synthesis and packing processes of nanomaterials helped to better understand the control level of the work environment and to suggest appropriate actions. The comparison of each process showed the effect of the production process and handling of solids and ventilation on exposure class.

Local Exhaust Ventilation Characteristics of Coal Dust in Coal Preparation Plant of a Coal Mine (석탄광산 선탄장에서 비산분진의 국소배기 특성)

  • Lee, Seung-Chul;Jo, Woo-Hyun;Park, Young-Rok;Ok, Yun-Yong;Kim, Tae-Hyuk
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.12a
    • /
    • pp.259-262
    • /
    • 2009
  • 본 연구에서는 석탄광산 선탄장설비와 국소배기시스템의 일부를 모형화하여 포집특성과 유동특성실험을 수행하였으며 동일조건에서 수치해석을 수행하여 그 결과를 비교 검토하였다. case 5가 46.35%의 가장 높은 포집효율을 보였으며 실험의 3가지 변수 중 고무 커튼의 사용유무가 국소배기시스템의 포집효율에 가장 큰 영향을 미치는 것으로 판단된다. 또한 case 1, 5, 6에 대해 포집된 입자크기 확인 결과, 포집성능이 우수한 case 5가 입경 $20{\mu}m$ 초과 입자들이 약 55%로 가장 많이 포집된 것을 알 수 있었다. 따라서 제어거리는 0.5m 이상이 적절한 것으로 판단된다.

  • PDF