• Title/Summary/Keyword: local electric field

Search Result 103, Processing Time 0.037 seconds

Two-Dimensional Numerical Simulation of GaAs MESFET Using Control Volume Formulation Method (Control Volume Formulation Method를 사용한 GaAs MESFET의 2차원 수치해석)

  • Son, Sang-Hee;Park, Kwang-Mean;Park, Hyung-Moo;Kim, Han-Gu;Kim, Hyeong-Rae;Park, Jang-Woo;Kwack, Kae-Dal
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.1
    • /
    • pp.48-61
    • /
    • 1989
  • In this paper, two-dimensional numerical simulation of GaAs MESFFT with 0.7${\mu}m$ gate length is perfomed. Drift-diffusion model which consider that mobility is a function of local electric field, is used. As a discretization method, instead of FDM (finite difference method) and FEM (finite element method), the Control-Volume Formulation (CVF) is used and as a numerical scheme current hybrid scheme or upwind scheme is replaced by power-law scheme which is very approximate to exponential scheme. In the process of numerical analysis, Peclet number which represents the velocity ratio of drift and diffusion, is introduced. And using this concept a current equation which consider numerical scheme at the interface of control volume, is proposed. The I-V characteristics using the model and numerical method has a good agreement with that of previous paper by others. Therefore, it is confined that it may be useful as a simulator for GaAs MESFET. Besides I-V characteristics, the mechanism of both velocity saturation in drift-diffusion model is described from the view of velocity and electric field distribution at the bottom of the channel. In addition, the relationship between the mechanism and position of dipole and drain current, are described.

  • PDF

SIMULTANEOUS OBSERVATIONS OF PI 2 PULSATIONS ON THE SATELLITE AND GROUND-BASED MEASUREMENTS (위성 및 지상자력계에서의 PI 2 파동 동시 관측)

  • 이성환;이동훈;김관혁
    • Journal of Astronomy and Space Sciences
    • /
    • v.14 no.2
    • /
    • pp.275-285
    • /
    • 1997
  • We have investigated Pi 2 pulsations which were observed both on ground magnetometer array and by satellites. On November 9th in 1994, Pi 2 pulsations appeared globally on the 190/210 magnetometer chain and Hermanus station when two satellites(EXOS-D and ETS-VI) were located near the magnetic meridian of the 210 array. The local time of measurements covers from morning(LT=8.47hr) to afternoon(LT=20.3hr) and the bandwidth of peak frequency is found relatively small. The signals of the electric field are highly coherent with ground-based observations with the out of phase oscillations. However, the magnetic field measurement on the ETS-VI in the outer magnetosphere(L=6.60) shows no signature of Pi 2 pulsations over the same time interval and the correlation with any of the ground-based stations is found to be very weak, even through both satellites and magnetometer chain are located close to each other in local time. We suggest that this event may be a direct evidence of Pi 2 pulsations as virtual resonant modes which are localized in the plasmasphere(Lee 1996). The results show that the cavity mode oscillations can occur in the inner magnetosphere with less spectral noise compared to the outer magnetospheric case.

  • PDF

A REVIEW OF CANDU FEEDER WALL THINNING

  • Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.568-575
    • /
    • 2010
  • Flow Accelerated Corrosion is an active degradation mechanism of CANDU feeder. The tight bend downstream to Gray loc weld connection, close to reactor face, suffers significant wall thinning by FAC. Extensive in-service inspection of feeder wall thinning is very difficult because of the intense radiation field, complex geometry, and space restrictions. Development of a knowledge-based inspection program is important in order to guarantee that adequate wall thickness is maintained throughout the whole life of feeder. Research results and plant experiences are reviewed, and the plant inspection databases from Wolsong Units One to Four are analyzed in order to support developing such a knowledge-based inspection program. The initial thickness before wall thinning is highly non-uniform because of bending during manufacturing stage, and the thinning rate is non-uniform because of the mass transfer coefficient distributed non-uniformly depending on local hydraulics. It is obvious that the knowledge-based feeder inspection program should focus on both fastest thinning locations and thinnest locations. The feeder wall thinning rate is found to be correlated proportionately with QV of each channel. A statistical model is proposed to assess the remaining life of each feeder using the QV correlation and the measured thicknesses. W-1 feeder suffered significant thinning so that the shortest remaining life barely exceeded one year at the end of operation before replacement. W-2 feeder showed far slower thinning than W-1 feeder despite the faster coolant flow. It is believed that slower thinning in W-2 is because of higher chromium content in the carbon steel feeder material. The average Cr content of W-2 feeder is 0.051%, while that value is 0.02% for W-1 feeder. It is to be noted that FAC is reduced substantially even though the Cr content of W-2 feeder is still very low.

Electrical and Reliability properties of MOS capacitors with $N_{2}O$ oxides ($N_{2}O$ 산화막을 갖는 MOS 캐패시터의 전기적 및 신뢰성 특성)

  • 이상돈;노재성;김봉렬
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.117-127
    • /
    • 1994
  • In this paper, electrical and reliability properties of N$_2$O oxides, grown at the temperature of 95$0^{\circ}C$ and 100$0^{\circ}C$ to 74$\AA$, and 82$\AA$. respectively, using NS12TO gas in a conventional furnace, have been compared with those of pure oxide grown at the temperature of 850 to 84$\AA$ using O$_2$ gas. Initial IS1gT-VS1gT characteristics of N$_2$O oxides were similar to those of pure oxide, and reliability properties of N$_2$O oxides, such as charge trapping, interface state density and leakage current at low electric field under F-N stress, were improved much better than those of pure oxide. But, with increasing capacitor area. TDDB characteristics of N$_2$O oxides were more degraded than those of pure oxide and this degradation of TDDB characteristics was more severe in 100$0^{\circ}C$ N$_2$Ooxide than in 95$0^{\circ}C$ N$_2$O oxide. The improvement of reliability properties excluding TDDB in N$_2$Ooxides was attributed to the hardness of the interface improved by nitrogen pile-up at the interface of Si/SiO$_2$, but on the other hand, the degradation of TDDB characteristics in N$_2$O oxides was obsered due to the increase of local thinning spots caused by excessive nitrogen at interface during the growth of N$_2$O oxides.

  • PDF

THEMIS Pi2 observations near dawn and dusk sectors in the inner magnetosphere

  • Kwon, Hyuck-Jin;Kim, Khan-Hyuk;Lee, Dong-Hun;Takahashi, K.;Park, Young-Deuk;Bonnell, J.W.
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.40.3-40.3
    • /
    • 2010
  • The most frequently suggested source for Pi2 pulsations in the inner magnetosphere (L < 4) is standing fast-mode waves trapped in the plasmasphere (i.e., plasmaspheric resonances). They have been considered as the source of low-latitude Pi2 pulsations. The plasmaspheric resonance model suggests that compressional fast-mode waves can be detected at all local times inside the plasmasphere provided reflection of the wave energy is efficient. Until now, however, there are no reports about compressional Pi2s observed in the dayside inner magnetosphere. That is, there is longitudinal limit of inner magnetosphere. In February 2008, THEMIS probes were near dawn and/or dusk sides, which are the transition regions between the nightside and dayside, in the inner magnetosphere (L = 2-4) when low-altitude Pi2s were identified at Bohyun (L = 1.35) station in Korea. Using the THEMIS electric field data, we examined if Pi2s are excited by longitudinally localized disturbances. We found that compressional Pi2s having high coherence with a low-latitude Pi2 pulsation occur on dawnside. However, any compressional pulsations in the Pi2 frequency band were not detected on duskside. This indicates that compressional Pi2s disappear near the duskside. Our observations are discussed with spatial plasmaspheric structure and possible Pi2 mechanisms.

  • PDF

Development of Spontaneous Polarization of Epitaxial Iron-Excess Gallium Ferrite Thin Films

  • Oh, S.H.;Shin, R.H.;Lee, J.H.;Jo, W.;Lefevre, C.;Roulland, F.;Thomasson, A.;Meny, C.;Viart, N.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2012.05a
    • /
    • pp.121-122
    • /
    • 2012
  • Iron-excess gallium ferrite, $Ga_{0.6}Fe_{1.4}O_3$ (GFO), is known to have room-temperature ferromagnetic phases and potentially exhibit ferroelectricity as well [1]. But, leaky polarization-electric field (PE) hysteresis curves of the GFO thin film are hurdle to prove its spontaneous polarization, in other words, ferroelecticity. One of the reasons that the GFO films have leaky PE hysteresis loop is carrier hopping between $Fe^{2+}$ and $Fe^{3+}$ sites due to oxygen deficiency. We focus on reducing conducting current by substituting divalent cations at $Fe^{2+}$ sites. GFO thin films were grown epitaxially along b-axis normal to $SrRuO_3/SrTiO_3$ (111) substrates by pulsed laser deposition. Current density of the ion-substituted GFO thin films was reduced by $10^3$ or more. Ferroelectric properties of the ion-substituted GFO thin films were measured using macroscopic and microscopic schemes. In particular, local ferroelectric properties of the GFO thin films were exhibited and their remnant polarization and piezoelectric d33 coefficient were obtained.

  • PDF

Evaluation of Chromosomal Alteration in Electrical Workers Occupationally Exposed to Low Frequency of Electro Magnetic Field (EMFs) in Coimbatore Population, India

  • Balamuralikrishnan, Balasubramanian;Balachandar, Vellingiri;Kumar, Shanmugam Suresh;Stalin, Nattan;Varsha, Prakash;Devi, Subramaniam Mohana;Arun, Meyyazhagan;Manikantan, Pappuswamy;Venkatesan, Chinnakulandhai;Sasikala, Keshavarao;Dharwadkar, Shahnaz N.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2961-2966
    • /
    • 2012
  • Extremely low frequency electro magnetic fields (EMFs) have been classified as possibly carcinogenic to humans by the International Agency for Research on Cancer. An increased number of chromosomal alterations in peripheral lymphocytes are correlated with elevated incidence of cancer. The aim of the present study was to assess occupationally induced chromosomal damage in EMF workers exposed to low levels of radiation. We used conventional metaphase chromosome aberration (CA) analysis and the micronucleus (MN) assay as biological indicators of non ionizing radiation exposure. In the present study totally 70 subjects were selected including 50 exposed and 20 controls. Informed written consent was obtained from all participants and the study was performed in accordance with the Declaration of Helsinki and the approval of the local ethical committee. A higher degree of CA and MN was observed in exposed subjects compared to controls, the frequency of CA being significantly enhanced with long years of exposure (P<0.05). Moreover increase in CA and MN with age was noted in both exposed subjects and controls, but was significantly greater in the former. The results of this study demonstrated that a significant induction of cytogenetic damage in peripheral lymphocytes of workers occupationally exposed to EMFs in electric transformer and distribution stations. In conclusion, our findings suggest that EMFs possess genotoxic capability, as measured by CA and MN assays; CA analysis appeared more sensitive than other cytogenetic end-points. It can be concluded that chronic occupational exposure to EMFs may lead to an increased risk of genetic damage among electrical workers.

Probabilistic rock mass classification using electrical resistivity - Theoretical approach of relationship between RMR and electrical resistivity- (전기비저항을 이용한 확률론적 암반분류 - RMR과 전기비저항 관계 이론 중심으로-)

  • Ryu, Hee-Hwan;Joo, Gun-Wook;Cho, Gye-Chun;Kim, Kyoung-Yul;Lim, Young-Duck
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.2
    • /
    • pp.97-111
    • /
    • 2013
  • It is very important to understand the condition of the surround rock for the successful construction of underground space. Representative methods of estimating the rock mass condition are RMR method and Q-system, and they are applied on design, construction, and maintenance. However, many problems with the accuracy of the measurement method and the subjective viewpoint are questioned continuously, so many researchers have been studied for estimating rock condition from various methods. Most of them show only the local relation and a tendency between site investigation data and rock conditions. In this paper, the relationship between RMR method and electrical resistivity is deducted using the analytical equation derived theoretically from electric field analysis on jointed rock mass. And also, probabilistic relationship between RMR method and electrical resistivity is deducted for the increase of accuracy. If a suggested method is applied with the conventional method for estimating the rock condition, it will be helpful to estimate RMR values on the field.

Analysis of Subwavelength Metal Hole Array Structure for the Enhancement of Quantum Dot Infrared Photodetectors

  • Ha, Jae-Du;Hwang, Jeong-U;Gang, Sang-U;No, Sam-Gyu;Lee, Sang-Jun;Kim, Jong-Su;Krishna, Sanjay;Urbas, Augustine;Ku, Zahyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.334-334
    • /
    • 2013
  • In the past decade, the infrared detectors based on intersubband transition in quantum dots (QDs) have attracted much attention due to lower dark currents and increased lifetimes, which are in turn due a three-dimensional confinement and a reduction of scattering, respectively. In parallel, focal plane array development for infrared imaging has proceeded from the first to third generations (linear arrays, 2D arrays for staring systems, and large format with enhanced capabilities, respectively). For a step further towards the next generation of FPAs, it is envisioned that a two-dimensional metal hole array (2D-MHA) structures will improve the FPA structure by enhancing the coupling to photodetectors via local field engineering, and will enable wavelength filtering. In regard to the improved performance at certain wavelengths, it is worth pointing out the structural difference between previous 2D-MHA integrated front-illuminated single pixel devices and back-illuminated devices. Apart from the pixel linear dimension, it is a distinct difference that there is a metal cladding (composed of a number of metals for ohmic contact and the read-out integrated circuit hybridization) in the FPA between the heavily doped gallium arsenide used as the contact layer and the ROIC; on the contrary, the front-illuminated single pixel device consists of two heavily doped contact layers separated by the QD-absorber on a semi-infinite GaAs substrate. This paper is focused on analyzing the impact of a two dimensional metal hole array structure integrated to the back-illuminated quantum dots-in-a-well (DWELL) infrared photodetectors. The metal hole array consisting of subwavelength-circular holes penetrating gold layer (2DAu-CHA) provides the enhanced responsivity of DWELL infrared photodetector at certain wavelengths. The performance of 2D-Au-CHA is investigated by calculating the absorption of active layer in the DWELL structure using a finite integration technique. Simulation results show the enhanced electric fields (thereby increasing the absorption in the active layer) resulting from a surface plasmon, a guided mode, and Fabry-Perot resonances. Simulation method accomplished in this paper provides a generalized approach to optimize the design of any type of couplers integrated to infrared photodetectors.

  • PDF

Case study of microseismic techniques for stability analysis of pillars in a limestone mine (석회석 광산 내 광주의 안정성 분석을 위한 미소진동 계측기술의 현장적용)

  • Kim, Chang Oh;Um, Woo-Yong;Chung, So-Keul;Cheon, Dae-Sung
    • Tunnel and Underground Space
    • /
    • v.26 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • This study deals with the case that was the field application of the microseismic monitoring techniques for the stability monitoring in a domestic mine. The usefulness and limitations of the microseismic techniques were examined through analyzing the microseismic monitored data. The target limestone mine adopted a hybrid room-and-pillar mining method to improve the extraction ratio. The accelerometers were installed in each vertical pillar within the test bed which has the horizontal cross-section $50m{\times}50m$. The measured signals were divided into 4 types; blasting induced signal, drilling induced signal, damage induced signal, and electric noise. The stability analysis was performed based on the measured damage induced signals. After the blasting in the mining section close to the test bed, the damage of the pillar was increased and rockfall near the test bed could be estimated from monitored microseismic data. It was possible to assess the pillar stability from the changes of daily monitored data and the proposed safety criteria from the accumulated monitored data. However, there was a difficulty to determine the 3D microseismic source positions due to the 2D local sensor arrays. Also, it was needed to use real-time monitoring methods in domestic mines. By complementing the problems encountered in the mine application and comparing microseismic monitored data with mining operations, the microseismic monitoring technique can be used as a better safety method.