• Title/Summary/Keyword: local compression

Search Result 408, Processing Time 0.029 seconds

Local Buckling in Steel Box Girder Bridge with Lifting and Lowering Support Method (지점 상승 하강 공법에 의한 강상자형교의 국부좌굴)

  • Koo, Min Se;Jeong, Jae Woon;Na, Gwi Tae
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.1
    • /
    • pp.77-85
    • /
    • 2003
  • The lifting and lowering supports method makes up for the weak points in the classical method and provides makes construction economical effect to construction. The application of pre-compression to continuous steel box girder bridges makes it possible to reduce the amount of steel, the height of girders and consequently, the cost consequentlyof the bridges' construction by through the process of concrete filling- up and the lifting-lowering of the inner supports. The lifting and lowering supports method is apt to cause local buckling in the lower flange and web plates by due to the process of the lifting of the inner supports. Therefore iln this study, therefore, the possibility of local buckling could be decreased, in consideration of the lifting force and the buckling strength of stiffened plates, by increasing the number of longitudinal stiffeners and the installation of extended longitudinal stiffeners on the lower flange and the web plates in the range of positive moment.

Modelling reinforced concrete beams under mixed shear-tension failure with different continuous FE approaches

  • Marzec, Ireneusz;Skarzynski, Lukasz;Bobinski, Jerzy;Tejchman, Jacek
    • Computers and Concrete
    • /
    • v.12 no.5
    • /
    • pp.585-612
    • /
    • 2013
  • The paper presents quasi-static numerical simulations of the behaviour of short reinforced concrete beams without shear reinforcement under mixed shear-tension failure using the FEM and four various constitutive continuum models for concrete. First, an isotropic elasto-plastic model with a Drucker-Prager criterion defined in compression and with a Rankine criterion defined in tension was used. Next, an anisotropic smeared crack and isotropic damage model were applied. Finally, an elasto-plastic-damage model was used. To ensure mesh-independent FE results, to describe strain localization in concrete and to capture a deterministic size effect, all models were enhanced in a softening regime by a characteristic length of micro-structure by means of a non-local theory. Bond-slip between concrete and reinforcement was considered. The numerical results were directly compared with the corresponding laboratory tests performed by Walraven and Lehwalter (1994). The advantages and disadvantages of enhanced models to model the reinforced concrete behaviour were outlined.

Robust Person Identification Using Optimal Reliability in Audio-Visual Information Fusion

  • Tariquzzaman, Md.;Kim, Jin-Young;Na, Seung-You;Choi, Seung-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.3E
    • /
    • pp.109-117
    • /
    • 2009
  • Identity recognition in real environment with a reliable mode is a key issue in human computer interaction (HCI). In this paper, we present a robust person identification system considering score-based optimal reliability measure of audio-visual modalities. We propose an extension of the modified reliability function by introducing optimizing parameters for both of audio and visual modalities. For degradation of visual signals, we have applied JPEG compression to test images. In addition, for creating mismatch in between enrollment and test session, acoustic Babble noises and artificial illumination have been added to test audio and visual signals, respectively. Local PCA has been used on both modalities to reduce the dimension of feature vector. We have applied a swarm intelligence algorithm, i.e., particle swarm optimization for optimizing the modified convection function's optimizing parameters. The overall person identification experiments are performed using VidTimit DB. Experimental results show that our proposed optimal reliability measures have effectively enhanced the identification accuracy of 7.73% and 8.18% at different illumination direction to visual signal and consequent Babble noises to audio signal, respectively, in comparison with the best classifier system in the fusion system and maintained the modality reliability statistics in terms of its performance; it thus verified the consistency of the proposed extension.

Clinical experience of a Hemipelvectomy in the End-Stage of the Pressure Sore (말기 압박궤양에 있어서 일측성 골반제거술의 임상례)

  • Lee, Sung-Su;Hong, Jong-Won;Chung, Yoon-Kyu;Oh, Jin-Rok;Hong, Joon-Pio
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.1
    • /
    • pp.47-52
    • /
    • 2002
  • One of the most common problems in cord injury is pressure sores. In the early stage of pressure sores, the wound can be covered by advancing or transpositioning a local myocutaneous flap. However, it can be a great challenge to treat end-stage paraplegic patient who underwent multiple prior flaps, where continuous treatment is needed to prevent recurrent pressure sore due to infection and metabolic drain. In these patients, a local myocutaneous flap may be very difficult for coverage of the wounds. Therefore, hemipelvectomy may be considered. The authors performed a hemipelvectomy on a 33 year-old male paraplegic patient who presented with multiple, large wounds seen in end-stage pressure sores. He had a compression fracture of the lumber spine 9 years ago during a motor vehicle accident. After a wide exicision of the wound, the anterior flap was used as a fillet-flap for reconstruction. On the sixth day postoperatively, secondary repair was done due to wound dehiscence and the postoperative results have been satisfactory thus far.

  • PDF

An Image-guided Radiosurgery for the Treatment of Metastatic Bone Tumors using the CyberKnife Robotic System

  • Cho, Chul-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2007
  • Bone is a common site for metastatic spread from many kinds of malignancies. The morbidity associated with this metastatic spread can be significant, including severe pain. When it comes to spinal metastasis, occupying nearly 40% of skeletal metastases, the risks of complications, such as vertebral body collapse, nerve root impingement, or spinal cord compression, are also significant. Because of the necessity of preserving the integrity of the spinal column and the proximity of critical structures, surgical treatment has limitations when durable local control is desired. Radiotherapy, therefore, is often used as an adjunct treatment or as a sole treatment. A considerable limitation of standard radiotherapy is the reported recurrence rate or ineffective palliation of pain, either clinically or symptomatically. This may be due to limited radiation doses to tumor itself because of the proximity of critical structures. CyberKnife is an image-guided robotic radiosurgical system. The image guidance system includes a kilovoltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator (6 MV) mounted on a robotic arm. Highly conformal fields and hypofractionated radiotherapy schedules are increasingly being used as a means to achieve biologic dose escalation for body tumors. Therefore, we can give much higher doses to the targeted tumor volume with minimizing doses to the surrounding critical structures, resulting in more effective local control and less severe side effects, compared to conventional fractionated radiotherapy. A description of this technology and a review of clinical applications to bone metastases are detailed herein.

  • PDF

Crippling Test of Z-section Graphite/Epoxy Stringers (Z-단면 Graphite/Epoxy 스트링거의 크리플링 실험)

  • 최상민;권진희
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.32-41
    • /
    • 2001
  • Z-section composite stringers with various lengths and flange-widths are tested in axial compression for the validation of a finite element algorithm to calculate the buckling and crippling stresses of composite laminated stringers. The stacking sequence considered is $[{\pm}45/0/90]s$. Strain gages are attached to each specimen, and deflection and end-shortening are obtained by two LVDTs. The buckling load is determined from the load vs. strain response, load vs. end-shortening curves, and load vs. out-of-plane deflection curves. The ultimate stress after local buckling is used as the crippling stress. Comparison between finite element and experimental results shows good agreement in the local buckling and crippling stresses.

  • PDF

A novel approach to design of local quantizers for distributed estimation

  • Kim, Yoon Hak
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.558-564
    • /
    • 2018
  • In distributed estimation where each node can collect only partial information on the parameter of interest without communication between nodes and quantize it before transmission to a fusion node which conducts estimation of the parameter, we consider a novel quantization technique employed at local nodes. It should be noted that the performance can be greatly improved if each node can transmit its measurement to one designated node (namely, head node) which can quantize its estimate using the total rate available in the system. For this case, the best strategy at the head node would be simply to partition the parameter space using the generalized Lloyd algorithm, producing the global codewords, one of which is closest to the estimate is transmitted to a fusion node. In this paper, we propose an iterative design algorithm that seeks to efficiently assign the codewords into each of quantization partitions at nodes so as to achieve the performance close to that of the system with the head node. We show through extensive experiments that the proposed algorithm offers a performance improvement in rate-distortion perspective as compared with previous novel techniques.

Teleoperation System of a Mobile Robot over the Internet (인터넷을 이용한 이동로봇의 원격 운용 시스템)

  • Park, Taehyun;Gang, Geun-Taek;Lee, Wonchang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.3
    • /
    • pp.270-274
    • /
    • 2002
  • This paper presents a teleoperation system that combines computer network and an autonomous mobile robot. We control remotely an autonomous mobile robot with vision over the Internet to guide it under unknown environments in the real time. The main feature of this system is that local operators need a web browser and a computer connected to the communication network and so they can command the robot in a remote location through the home page. The hardware architecture of this system consists of an autonomous mobile robot, workstation, and local computers. The software architecture of this system includes the client part for the user interface and robot control as well as the server part for communication between users and robot. The server and client systems are developed using Java language which is suitable to internet application and supports multi-platform. Furthermore. this system offers an image compression method using JPEG concept which reduces large time delay that occurs in network during image transmission.

Pain Management for low back Pain and Lumbosacral Radiculopathy (요통에 대한 통증관리)

  • Kang, Keung-Mo;Ban, Jong-Seok;Min, Byung-Woo
    • The Korean Journal of Pain
    • /
    • v.1 no.2
    • /
    • pp.181-187
    • /
    • 1988
  • Since the introduction of epidural corticosteroid injections for the management of sciatica, lumbosacral radiculopathy has become one of the most common pain problems encountered by anesthesiologists. In order to function effectively, anesthesiologists should be able to: (1) recognize those syndromes which may respond to nerve block; (2) understand the pathophysiology of the conditions being treated and (3) be familiar with alternate therapeutic pathways for patients not responding to merre block. There are many etiologic factors of low back pain and lumbosacral radiculopathy. Particularly, Nerve root compression caused by a protruding disc, a osteophyte or tumors are usually responsible for pain. Neural inflammation, therefore, is considered to play a major role in pain production. The use of local anesthetics in mixture with steroids is believed to break down neural inflammation. Steroids and local anesthetics were injected lumbar or caudal epidmal to 106 patients for the purpose of relieving low back pain and lumbosacral radiculopathy. The results are as follows: Excellent pain relieved group: 27 patients (25.5%) Good pain relieved group: 49 patients (46.1%) Fair pain relieved group: 15 patients(14.2%) Not effective group: 15 patients(14.2%).

  • PDF

Implementation of Self-frequency Synchronizing Circuit using Single-sideband Up-converter and Image Rejection Mixer (단측파대 상향변환기와 이미지제거 혼합기를 이용한 자기동조회로의 구현)

  • Yeom, Seong-Hyeon;Kim, Tae-Young;Kim, Tae-Hyun;Park, Boem-June
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1058-1063
    • /
    • 2010
  • In this paper, we designed self-frequency synchronizing circuit using image rejection mixer(IRM) and single-sideband(SSB) up-converter which can effectively eliminate the image frequencies occurred in multi-channel super-heterodyne receivers and help us to match inter-channel phase. Also the self-frequency synchronizing circuit simplifies system because there need no extra devices for making intermediate frequency(IF) by creating the local signal within several nanoseconds by means of generating the same frequency of IF signal and modulating radio frequency(RF) signal. We adopt the limiting amplifier for the purpose of protecting the circuit from spurious signals which come from the front end side having wide instantaneous bandwidth characteristics and constantly injecting same level into the input local signal of IRM. The IRM we fabricated has image rejection ratio of 27dB, which is good over 7dB for foreign company's. Also, the SSB up-converter we fabricated has 1dB compression point of 18dBm, which is good over 16dB for foreign company's. And the size is compact about one-forth.