• Title/Summary/Keyword: local average

Search Result 1,899, Processing Time 0.035 seconds

Splitting and Merging Algorithm Based on Local Statistics of Sub-Regions in Document Image

  • Thapaliya, Kiran;Park, Il-Cheol;Kwon, Goo-Rak
    • Journal of information and communication convergence engineering
    • /
    • v.9 no.5
    • /
    • pp.487-490
    • /
    • 2011
  • This paper presents splitting and merging algorithm based on adaptive thresholding. The algorithm first divides the image into blocks, and then compares each block using the calculated thresholding value. The blocks which are same are merged using the certain threshold value and different blocks are split unless it satisfies the threshold value. When the block has been merged, maximum and minimum block sizes are determined then the average block size is determined. After the average block size is determined the average intensity and standard deviation of average block is calculated. The process of thresholding is applied to binarize the image. Finally, the experimental results show that the proposed method distinguishes clearly the background with text in the document image.

Comparison of K-index Calculations between Several Geomagnetic Stations during IQDs and IDDs

  • Hwang, Junga;Kim, Hang-Pyo;Park, Young-Deuk
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.3
    • /
    • pp.169-174
    • /
    • 2013
  • BOH magnetometer was installed at Mt. Bohyun in 2007 and has provided continuous dataset for 3-axis geomagnetic field over the South Korea. We have calculated real-time K-index based on BOH magnetic field data using well-known FMI method. Local K-index is calculated eight times a day, per every three hours. To calculate K-index, it is critical to get the Quiet Day Curve (QDC). For QDC calculation, we take the previous one month's average of H-component. In this paper, we compared four geomagnetic stations' magnetic field data over South Korea and Japan and K-indices of each stations; Bohyun, Gangneung, Jeju, and Kakioka for two years data, 2011-2012. To investigate the difference depending on the latitude, longitude and local time in more detail, we compare K-index on International Quiet Days (IQDs) and International Disturbed Days (IDDs). As a result, we report the correlation between local K-indices are higher than those between Kp and local K-indices, and the correlation is much better after sunset than after sunrise. As the geomagnetic activity becomes stronger, the correlation between the local K-indices and global Kp-index become higher.

A Study on the Local Regression Rate of Solid Fuel in Hybrid Rocket (하이브리드 로켓에서의 고체연료의 국부 후퇴율에 관한 연구)

  • Kim, Soojong;Lee, Jungpyo;Kim, Gihun;Cho, Jungtae;Kim, Hakchul;Woo, Kyoungjin;Moon, Heejang;Sung, Hong-Gye;Kim, Jin-Kon
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.4
    • /
    • pp.1-6
    • /
    • 2008
  • In generally, the regression rate was expressed with average value and oxidizer mass flux in hybrid propulsion system. This can not represent the local value of regression rate along with oxidizer flow direction. In this study, experimental studies were performed with Separation method and Cutting method for measure local regression rate. In axial injection, the local regression rate decreases rapidly with axial location near entrance and increases with axial direction from the leading edge and the empirical formula for local regression rate with function of oxidizer mass flux and location was derived. Swirl injection regression rate has higher value at the leading edge of the fuel and comparatively uniform regression rate at the downstream. Overall regression rate of swirl injection is higher increased about 54 % than regression rate of axial injection.

  • PDF

Pain control using the Point-Inject Technique in dental local anesthesia (Point Inject Technique을 이용한 치과 국소마취의 통증 조절 및 진료 효율의 극대화)

  • Lee, Jae-youn;Choe, Sunga
    • Journal of Korean Academy of Dental Administration
    • /
    • v.9 no.1
    • /
    • pp.32-37
    • /
    • 2021
  • Many approaches to local anesthesia have been studied in dentistry. In this study, we introduce a new local anesthetic method, "Point-Inject Technique (PIT)", and compare it with traditional injection techniques. The PIT method utilizes both the vasoconstrictive and antinociceptive properties of local anesthetics as well as the application of controlled pressure during injection, reducing the time to complete anesthesia. Fifty patients were selected as the experimental group who were anesthetized using PIT, and the other 50 patients were selected as the control group using the direct injection method with a carpool syringe. The PIT group received 0.25 cartridges of 2% lidocaine with 1:100,000 epinephrine. The control group received 1.5~2 cartridges of 2% lidocaine with 1:100,000 epinephrine. Both groups were asked to mark the intensity of the pain caused by anesthesia using the Numeric Pain Rating Scale. The average time to recover from anesthesia was 40 minutes in the experimental group and 90 minutes in the control group. Additionally, 96% of the experimental group reported feeling no pain, while 78% of the control group reported having some form of pain during injection. The PIT method reduced both the reported pain scores of patients as well as time to recover from local anesthesia than the widely-used syringe injection method.

A Video Cache Replacement Scheme based on Local Video Popularity and Video Size for MEC Servers

  • Liu, Pingshan;Liu, Shaoxing;Cai, Zhangjing;Lu, Dianjie;Huang, Guimin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.9
    • /
    • pp.3043-3067
    • /
    • 2022
  • With the mobile traffic in the network increases exponentially, multi-access edge computing (MEC) develops rapidly. MEC servers are deployed geo-distribution, which serve many mobile terminals locally to improve users' QoE (Quality of Experience). When the cache space of a MEC server is full, how to replace the cached videos is an important problem. The problem is also called the cache replacement problem, which becomes more complex due to the dynamic video popularity and the varied video sizes. Therefore, we proposed a new cache replacement scheme based on local video popularity and video size to solve the cache replacement problem of MEC servers. First, we built a local video popularity model, which is composed of a popularity rise model and a popularity attenuation model. Furthermore, the popularity attenuation model incorporates a frequency-dependent attenuation model and a frequency-independent attenuation model. Second, we formulated a utility based on local video popularity and video size. Moreover, the weights of local video popularity and video size were quantitatively analyzed by using the information entropy. Finally, we conducted extensive simulation experiments based on the proposed scheme and some compared schemes. The simulation results showed that our proposed scheme performs better than the compared schemes in terms of hit rate, average delay, and server load under different network configurations.

Wavelet Based Non-Local Means Filtering for Speckle Noise Reduction of SAR Images (SAR 영상에서 웨이블렛 기반 Non-Local Means 필터를 이용한 스펙클 잡음 제거)

  • Lee, Dea-Gun;Park, Min-Jea;Kim, Jeong-Uk;Kim, Do-Yun;Kim, Dong-Wook;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.3
    • /
    • pp.595-607
    • /
    • 2010
  • This paper addresses the problem of reducing the speckle noise in SAR images by wavelet transformation, using a non-local means(NLM) filter originated for Gaussian noise removal. Log-transformed SAR image makes multiplicative speckle noise additive. Thus, non-local means filtering and wavelet thresholding are used to reduce the additive noise, followed by an exponential transformation. NLM filter is an image denoising method that replaces each pixel by a weighted average of all the similarly pixels in the image. But the NLM filter takes an acceptable amount of time to perform the process for all possible pairs of pixels. This paper, also proposes an alternative strategy that uses the t-test more efficiently to eliminate pixel pairs that are dissimilar. Extensive simulations showed that the proposed filter outperforms many existing filters terms of quantitative measures such as PSNR and DSSIM as well as qualitative judgments of image quality and the computational time required to restore images.

Heat Transfer from Single and Arrays of Impinging Water Jets(I)-Single Water Jet- (단일수분류 및 수분류군에 의한 열전달(I)-단일수분류-)

  • Eom, Gi-Chan;Lee, Jong-Su;Yu, Ji-O
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.9
    • /
    • pp.1105-1114
    • /
    • 1997
  • The heat transfer characteristics of free surface water jet impinging normally against a flat uniform heat flux surface were investigated. This deals with the effect of three nozzle configurations (Cone type, Reverse cone type, Vertical circular type) on the local and the average heat transfer. Heat transfer measurements were made for water jet issuing from a nozzle of which exit diameter 8 mm. The experimental conditions investigated are Reynolds number range of 27000 ~ 70000( $V_{O}$=3 ~ 8 m/s), nozzle-to-target plate distances H/D=2 ~ 10, and radial distance from the stagnation point r/D ~ = 0 ~ 7.42. For all jet velocities of H/D=2, the local Nusselt number decreased monotonically with increasing radial distance. However, for H/D from 4 to 10, and for the jet velocity $V_{O}$.geq.7 m/s for Cone type nozzle and $V_{O}$.geq.6 m/s for the other type nozzles, the Nusselt number distributions exhibited secondary peaks at r/D=3 ~ 3.5. For Reverse cone type nozzle and Vertical circular nozzle, the maximum stagnation point heat transfer and the maximum average heat transfer occurs at H/D=8. But for the Cone type nozzle, the maximum stagnation and average heat transfer occurs at H/D=10, 4, respectively. From the optimum nozzle-to-target plate distance, the stagnation and the average heat transfer reveal the following ranking: Reverse cone type nozzle, Vertical circular type nozzle, Cone type nozzle.ozzle.

Comparative Analysis on the Cremation Rate of the Capital Area and the Increase Rate of Cremated Bodies Using the Online Cremation Reservation Service in Funeral Information System

  • Choi, Jae-sil;Kim, Jeong-lae
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.11 no.3
    • /
    • pp.87-94
    • /
    • 2019
  • In the study, we show the annual average increasing rate of death bodies in the capital area was 2.1% while the annual average increasing rate of cremated bodies was 4.5%. As the annual average increasing rate of cremated bodies was about 2.1 times higher than the annual average increasing rate of death bodies, the increase rate of cremated bodies contrast to the increase rate of death bodies was relatively high. Also, the cremation rate of the capital area was increased by 9.5% from 80.3% in 2011 to 89.8% in 2017 while the increase rate of cremated bodies was 27.2%(N=21,694 people) from 79,866 people in 2011 to 101,560 people in 2017. Thus, the increase rate of cremated bodies contrast to the increase of cremation rate of the capital area was relatively very high. On the basis of 2017, the utilization rate of public cremation facilities in by capital area was 94.5% in Incheon Metropolitan City, 91.1% in Seoul Metropolitan City, and 20.9% in Gyeonggi-do, which showed huge differences in the utilization rate of public cremation facilities in the jurisdiction area of by capital area. Focusing on the actual state shown in the results of this study above, it would be necessary for Seoul Metropolitan City to carry forward a supply & demand policy of cremation facilities through the extension of cremation furnaces, for Gyeonggi-do to carry forward a policy to build the public cremation facilities focusing on the basic local government in the jurisdiction area, and for Incheon Metropolitan City to enforce the measures for the joint use of cremation facilities with the basic local government in the adjacent Gyeonggi-do jurisdiction area in order to improve the efficiency of the operation of cremation facilities.

A Study of the Pitch Estimation Algorithms of Speech Signal by Using Average Magnitude Difference Function (AMDF) (AMDF 함수를 이용한 음성 신호의 피치 추정 Algorithm들에 관한 연구)

  • So, Shinae;Lee, Kang Hee;You, Kwang-Bock;Lim, Ha-Young;Park, Jisu
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.4
    • /
    • pp.235-242
    • /
    • 2017
  • Peaks (or Nulls) finding algorithms for Average Magnitude Difference Function (AMDF) of speech signal are proposed in this paper. Both AMDF and Autocorrelation Function (ACF) are widely used to estimate a pitch of speech signal. It is well known that the estimation of the fundamental requency (F0) for speech signal is not only important but also very difficult. In this paper, two algorithms, are exploited the characteristics of AMDF, are proposed. First, the proposed algorithm which has a Threshold value is applied to the local minima to detect a pitch period. The Other proposed algorithm to estimate a pitch period of speech signal is utilized the relationship between AMDF and ACF. The data in this paper, is recorded by using general commercial device, is composed of Korean emotion expression words. The recorded speech data are applied to two proposed algorithms and tested their performance.

A Study on the Extremely Low Frequency Magnetic Fields Exposure Characteristics of Workers in LCD Manufacturing Process (LCD 제조공정 종사근로자의 극저주파자기장 노출특성 연구)

  • Kim, JoonBeom;Kang, Joon Hyuk;Chung, Eun-Kyo;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.1
    • /
    • pp.10-20
    • /
    • 2022
  • Objectives: The aim of this study is to evaluate exposure levels of the extremely low frequency magnetic fields(ELF-MF) radiated from various electric facilities in Liquid Crystal Display(LCD) manufacturing processes. Methods: This study measured the exposure levels of personal and local ELF-MF for the electronic facilities installed in two LCD manufacturing companies. Samplers were installed around workers' waist during working hours to identify personal exposure levels, and direct reading equipment were located at 3 cm, 10 cm, and 30 cm away from the surface of the electronic facilities to measure local exposure levels. Average and maximum(ceiling) values were calculated for personal and local exposure levels. Results: Average and maximum of personal exposure levels for each worker were 0.56(mean) ± 0.02(SE) µT and 6.31 ± 0.75 µT, respectively. Statistical analyses of the study found that maximum of the personal exposure levels for engineers was significantly higher than that for operators since engineers spend more time near the electronic facilities for repairing. The range of maximum personal exposure levels was 0.50 ~ 43.50 µT and its highest level was equivalent to 4.35 % of ACGIH(American Conference of Governmental Industrial Hygienists) exposure limit value(1 mT). Maximum of local exposure levels was 8.18 ± 0.52 µT and the electronic facilities with higher exposure levels were roof rail and electric panel, which were not related to direct manufacturing. The range of maximum local exposure levels was 0.60 ~ 287.20 µT and its highest level was equivalent to 28.7 % of the ACGIH exposure limit value. Lastly, the local exposure levels significantly decreased as the measurement distance from the electronic facilities increased. Conclusions: Maximum of personal and local exposure levels did not exceed the exposure limit value of ACGIH. However, it is recommended to keep the workers as far as possible from the sources of ELF-MF.