• 제목/요약/키워드: loading rates

검색결과 580건 처리시간 0.037초

Influence of loading rate on flexural performance and acoustic emission characteristics of Ultra High Performance Concrete

  • Prabhat Ranjan Prem;Vignesh Kumar Ramamurthy;Vaibhav Vinod Ingle;Darssni Ravichandran;Greeshma Giridhar
    • Structural Engineering and Mechanics
    • /
    • 제89권6호
    • /
    • pp.617-626
    • /
    • 2024
  • The study investigated the behavior of plain and fibered Ultra-High Performance Concrete (UHPC) beams under varying loading conditions using integrated analysis of the flexure and acoustic emission tests. The loading rate of testing is -0.25 -2 mm/min. It is observed that on increasing loading rate, flexural strength increases, and toughness decreases. The acoustic emission testing revealed that higher loading rates accelerate crack propagation. Fiber effect and matrix cracking are identified as significant contributors to the release of acoustic emission energy, with fiber rupture/failure and matrix cracking showing rate-dependent behavior. Crack classification analysis indicated that the rise angle (RA) value decreased under quasi-static loading. The average frequency (AF) value increased with the loading rate, but this trend reversed under rate-dependent conditions. K-means analysis identified distinct clusters of crack types with unique frequency and duration characteristics at different loading rates. Furthermore, the historic index and signal strength decreased with increasing loading rate after peak capacity, while the severity index increased in the post-peak zone, indicating more severe damage. The sudden rise in the historic index and cumulative signal strength indicates the possibility of several occurrences, such as the emergence of a significant crack, shifts in cracking modes, abrupt failure, or notable fiber debonding/pull-out. Moreover, there is a distinct rise in the number of AE knees corresponding to the increase in loading rate. The crack mapping from acoustic emission testing aligned with observed failure patterns, validating its use in structural health monitoring.

음폐수 부하량에 따른 고온호기성 공정의 처리 양상 (Influence of Food Wastewater Loading Rate on the Reactor Performance and Stability in the Thermophilic Aerobic Process)

  • 장현민;최석순;하정협;박종문
    • 공업화학
    • /
    • 제24권3호
    • /
    • pp.279-284
    • /
    • 2013
  • 본 연구에서는 음식물류 폐기물 자원화 과정에서 생성되는 고농도 음폐수(food wastewater : FWW)를 대상으로 기존의 혐기성 공정의 대안책으로써 고온호기성 소화공정에 대한 성능을 검증하였고 공정 인자를 도출하였다. 이를 위해 수리학적 체류시간(Hydraulic retention time, HRT) 변화 및 유기물 부하량(Organic loading rate, OLR)에 따른 유기물 제거 효율과 안정성을 관찰하였다. 실험 결과 비교적 짧은 HRT를 가진 R1 (HRT : 5일)의 경우 OLR이 증가할 때, 급격한 pH감소가 일어나 심한 공정 저해를 받는 것으로 관찰되었다. 반면 R2 (HRT : 10일)의 경우에는 상대적으로 안정적인 공정 운전 및 효율적인 COD, 유기산 및 lipid 제거가 일어났다. 이는 상대적으로 긴 HRT로 인한 유기산 축적과 같은 공정저해 요인이 해결되어 상대적으로 높은 유기물 처리효율을 나타낸 것으로 생각된다. R1에서는 COD 부하량이 $18.6kgCOD/m^3d$에서 $28.4kgCOD/m^3d$으로 증가함에 따라 급격한 COD 제거율 감소를 보였다. 반면 R2에서는 각 OLR별로 3.61, 7.05, 9.43 그리고 $12.2kgCOD/m^3d$의 높은 COD 제거율을 보였다. 따라서 본 연구에서는 10일 이상의 HRT에서 고온 호기성 소화가 고농도 음폐수 처리에 탁월한 유기물 제거율을 나타냄을 알 수 있었다.

A Multicenter Clinical Study on the Survival and Success Rates of Two Commercial Implants of Korea according to Loading Period

  • Yoon, Sung-Hwan;Kim, Myung-In;Chung, Kwang;Jung, Seunggon;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun;Kim, Su-Gwan;Kim, Young-Kyun;Cho, Yong-Seok;Kim, Woo-Cheoul;Yang, Choon-Mo
    • Journal of Korean Dental Science
    • /
    • 제6권2호
    • /
    • pp.67-77
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the survival and success rates of Korean Osstem implants US II Plus, GS II following loading period. Materials and Methods: Dental records were obtained in total 201 patients who were treated with Korean Osstem implants US II Plus, GS II on both maxillary and mandibular anterior and posterior areas in six different clinics for 2 years from January 2007 to December 2008. Total 430 implants were evaluated clinically and radiographically using predefined success criteria prospectively and following results were obtained. Result: US II Plus, GS II implants showed high survival rates of more than 99% and high success rates more than 90% independent of loading period. As a result of cross analysis to evaluate clinical significance between implant loading period and success rate, the P-value of US II Plus was 0.10 (P>0.05), and the P-value of GS II was 0.17 (P>0.05), which showed no statistical significance. Bone quality, smoking, and edentulous state are factors that can affect the survival and success rates following differently loaded implants, but did not significantly affect in this study. Conclusion: These results suggest that selection of loading period of Korean Osstem implants US II Plus, GS II would be done carefully considering implant install area, the quality alveolar bone, the state of edentulous ridge and experience of operator, though they showed clinically good results on both maxillary and mandibular anterior and posterior areas.

혐기 소화 시 식물체 잔사 및 투입량에 따른 메탄 생산량 예측 (Predicting Methane Production on Anaerobic Digestion to Crop Residues and Biomass Loading Rates)

  • 신중두;홍승길;박상원;김현욱
    • 유기물자원화
    • /
    • 제24권3호
    • /
    • pp.75-82
    • /
    • 2016
  • 본 연구의 목적은 농업에서 발생하는 식물체 잔사 종류별 투입비율에 따른 메탄 잠재 발생량을 예측하는 것이다. 바이오가스를 생산하기 위하여 보릿짚 및 유채대 등의 식물체 잔사를 다양한 투입율로 사용하여 세륨병에서 실험을 수행하였다. 표면 방법론의 운동방법을 통하여 메탄 생산은 Gomperz 수식에 적합한 것으로 나타났다. 중온소화 시 식물체 잔사별 바이오가스 생산에 있어, 최대생산량은 보릿짚 및 유채대 투입율 1%로 혐기소화 후 각각 6.8일에 37.2 mL/g과 7.5일에 28.0 mL/g로 나타났다. 중온소화 시 메탄 함량은 보릿짚 및 유채대 투입율 5%로 혐기소화 후 각각 5.5일에 61.7%와 3.4일에 75.0%로 가장 높게 관측되었다. 중온 소화시 최대 메탄 잠재발생량은 1% 보릿짚 투입율에서 159.59 mL/g 와 3% 유채대 투입율에서 156.62 mL/g로 산정되었다. 전반적으로 중온소화 시 바이오매스 투입율은 유채대 3% 및 보릿짚 1%를 투입하는 것이 적정 비율인 것으로 나타났다.

암모니아 가스 제거를 위한 포괄고정화 담체 개발 (Development of Encapsulated Media for Ammonia Removal)

  • 정미영;남궁형규;송지현;황선진
    • 한국물환경학회지
    • /
    • 제25권2호
    • /
    • pp.306-310
    • /
    • 2009
  • Packed-bed reactor for removing ammonia was tested at different loading rates. Nitrifiers for ammonia removing was encapsulated in gel media which consisted of polyethlene glycol, alginate and activated carbon. The removal efficiency was nearly 100% when ammonia loading was $12g/m^3/hr$, and the maximum elimination capacity (EC) achieved on this study was $18g/m^3/hr$. The initial microbial portion of nitrifiers in the media was about 82% and it was increased to more than 90% at the end of the operation. Short-term shock loading test was carried out to survey the stability of the media. The inlet loading rates were varied from 2 to $20g/m^3/hr$. The packed-bed reactor overcame the shock loading i.e. removal efficiency recovered rapidly from about 80% to almost 100% within 6 hrs. The results of Live/Dead cell test showed that nitrifiers maintained there activity in the encapsulated media during the test and also against ammonia shock load.

혼합모드 하중조건에서의 철도 차륜재의 피로균열 실험에 관한 연구 (Fatigue Crack Growth Rates of a Railway Wheel Steel under Mixed Mode Loading Conditions)

  • 김택영;이만석;유인동;김호경
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.8-13
    • /
    • 2013
  • Fatigue crack growth tests were conducted on urban railway wheel steel under mode I and mixed-mode conditions. Fatigue crack growth rates were evaluated in terms of equivalent stress intensity factor ranges, using both the extended and projected crack lengths. The equivalent stress intensity factor range with the growth rate results obtained under mode I loading conditions can be used to predict the crack growth rate under mixed-mode loading conditions. Extended crack length rather than projected crack length is appropriate for the prediction of the crack growth rate under the mixed-mode loading conditions.

강우로 인해 고속도로로부터 유출되는 폐기물의 성상, 부하량 및 유출 특성 (Loading Rates and Characteristics of Litter from Highway Stormwater Runoff)

  • 김이형;강주현
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.415-421
    • /
    • 2004
  • Litter wastes on highway runoff are gradually being considered one of the major pollutants of concern in protecting the integrity of receiving waters for beneficial use. The California State Water Resources Control Board has identified in their 303(d) list at least 36 water bodies where trash or litter is considered a pollutant of concern. The first TMDL adopted by the Region 4 (Los Angeles area) of the California State Water Quality Control Board was for trash in the Los Angeles River. The first flush characteristic study was developed to obtain first flush water quality and litter data from representative stormwater runoff from standard highway drainage outfalls in the Los Angeles area. Total captured gross pollutants in stormwater runoff were monitored at six Southern California highway sites over two years. The gross pollutants were 90% vegetation and 10% litter. Approximately 50% of the litter was composed of biodegradable materials. The event mean concentrations show an increasing trend with antecedent dry days and a decreasing trend with total runoff volume or total rainfall. Event mean concentrations were ranged 0.0021 to 0.259g/L for wet gross pollutants and 0.0001 to 0.027g/L for wet litters. The first flush phenomenon was evaluated and the impacts of various parameters such as rainfall intensity, drainage area, peak flow rate, and antecedent dry period on litter volume and loading rates were evaluated. First flush phenomenon was generally observed for litter concentrations, but was not apparent with litter mass loading rates. Litter volume and loading rates appear to be directly related to peak storm intensity, antecedent dry days and total flow volume.

해수 조건에서 모래유동층 여과조의 TAN 부하량과 수온에 따른 질산화 효율 (Nitrification Efficiency of the Fluidized Sand Biofilter by TAN Leading Rates and Temperatures in the Simulated Seawater Aquaculture Condition)

  • 박정환
    • 한국수산과학회지
    • /
    • 제38권6호
    • /
    • pp.347-352
    • /
    • 2005
  • These experiments investigated the conditioning pattern and the nitrification efficiency of a fluidized sand biofilter (FSB) for seawater application. The FSB fed artificial nutrient was fully conditioned within 22 weeks. The maximum nitrification efficiency of the FSB was achieved at a superficial water velocity (SWV) of 1.0 cm/sec. After fixing the superficial water velocity at 1.0 cm/sec, the nitrification rates of the FSB were assessed at 3 total ammonia nitrogen (TAN) loading rates (250, 500, 1,000 g TAN/$m^3$/day) and 3 water temperatures (12, 16, $20^{\circ}C$). The TAN concentration in the simulated culture tank ranged from 2.87 to 9.72 mg/L at TAN loading rate of 1,000 g TAN/$m^3$/day, while that ranged from 0.45 to 1.26 mg/L at TAN loading rate of 500 g TAN/$m^3$/day. The ranges of TAN concentration in the former were too high for aquatic organisms and those in the latter were acceptable. Therefore, the safe TAN loading rate for the FSB in seawater conditions was decided as 500 g TA/$m^3$/day. From these results, daily TAN removal rates (g TAN/$m^3$/day) of FSB under conditions of inlet TAN concentration (C, mg/L) and water temperature (T, $^{\circ}C$) were calculated by the following non-linear multi-regression equation: TAN removal rate: f(z)=-1,311.295+655.714LnT+225.775LnC ($r^2=0.962$).

이축 정적 하중이 부가된 반복 인장 혹은 비틀림 하중하에서 균열 발생과 성장 거동 (Behavior of Fatigue Crack Initiation and Propagation under Cyclic Tensile or Torsional Loading with Superimposed Static Biaxial Load)

  • 허용학;박휘립;권일범;김진영
    • 대한기계학회논문집A
    • /
    • 제24권6호
    • /
    • pp.1446-1455
    • /
    • 2000
  • Fatigue crack initiation and propagation behavior under cyclic biaxial loading has been investigated using thin-walled tubular specimen with a hole. Two types of biaxial loading system, i.e. cyclic tensile loading with super-imposed static torsional load and cyclic torsional loading with superimposed static tensile load, with various values of the biaxial loading ratio, $\tau$ s/ $\sigma$ max (or $\tau$ max/ $\sigma$s) were employed. Fatigue tests show that fatigue crack near the hole initiates and propagates at 900 and 450 direction to the longitudinal direction of the specimen under cyclic tensile and torsion loading with static biaxial stress, respectively, and the static biaxial stress doesn't have any great influence on fatigue crack initiation and growth direction. Stress analysis near the hole of the specimen shows that the crack around the hole initiates along the plane of maximum tangential stress range. Fatigue crack growth rates were evaluated as functions of equivalent stress intensity factor range, strain energy density factor range and crack tip opening displacement vector, respectively. It is shown that the biaxial mode fatigue crack growth rates can be relatively consistently predicted with these cyclic parameters.

이축방향 교번반복하중을 받는 구형 철근콘크리트교각의 거동특성 시험 (Bi-Axial Alternate Cyclic Loading Test of Rectangular Reinforced Concrete Columns)

  • 김재관;김익현;이재호;김남식
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.323-328
    • /
    • 2001
  • The behavior of bridge column under multi-directional loading as well as uni-directional loading need to be studied because bridge columns will be subjected to the multi-directional cyclic loading during a strong earthquake. To evaluate the capacity of columns, uni-axial cyclic loading tests and bi-axial alternate cyclic loading tests were carried out. The number of cycles of alternate bi-axial loading were determined considering the ratio of natural frequencies in two orthogonal directions. From the test results, strength degradation and ductility reduction were observed in biaxial loading conditions. Their rates were found to be more rapid in the loading pattern that was determined considering the different natural frequencies.

  • PDF