• Title/Summary/Keyword: loading protocols

Search Result 33, Processing Time 0.021 seconds

Structural Performance Evaluation of Buckling-Restrained Braces Made of High-Strength Steels (고강도강 비좌굴 가새의 구조성능 평가)

  • Park, Man Woo;Ju, Young Kyu;Kim, Myeong Han;Kim, Ji Young;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.1
    • /
    • pp.33-42
    • /
    • 2008
  • Buckling-Restrained Braces (BRB) has been developed to inhibit buckling and exhibit stable behavior underboth tensile and compresive cycles. In this study, an experime nt has been conducted by using the strength of its members and loading protocols as parameters to evaluate the structural performance of BRB (without in-filed concrete). Specimens are composed of an inner core and an outer tube with diferent steel strengths. When high-strength steels were used as iner cores, the ductility of BRB decreased, and the requirements (Cumulative Plastic Ductility) of the AISC Seismic Provisions were not satisfied. however, when high-strength steels were used as inner cores instead of conventional strength stel cores, the maximum capacity increased significantly and displayed similar performance in total energy dissipation.

Seismic demand estimation of electrical cabinet in nuclear power plant considering equipment-anchor-interaction

  • Cho, Sung Gook;Salman, Kashif
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1382-1393
    • /
    • 2022
  • This paper investigates the seismic behavior of an electrical cabinet considering the influence of equipment-anchor-interaction (EAI) that is generally not taken into consideration in a decoupled analysis. The hysteresis behavior of an anchor bolt in concrete was thereby considered to highlight this interaction effect. To this end, the experimental behavior of an anchor bolt under reversed cyclic loading was taken from the recently developed literature, and a numerical model for the anchor hysteresis was developed using the component approach. The hysteresis properties were then used to calibrate the multi-linear link element that is implemented as a boundary condition for the cabinet incorporating the EAI. To highlight this EAI further, the nonlinear time history analysis was performed for a cabinet considering the hysteresis behavior comparative to a fixed boundary condition. Additionally, the influence on the seismic fragility was evaluated for the operational and structural condition of the cabinet. The numerical analysis considering the anchor hysteresis manifests that the in-cabinet response spectra (ICRS) are significantly amplified with the corresponding reduction in the seismic capacity of 25% and 15% for an operational and structural safety condition under the selected protocols. Considering the fixed boundary condition over a realistic hysteresis behavior of the anchor bolt is more likely to overestimate the seismic capacity of the cabinet in a seismic qualification procedure.

Comparison of sandblasted and acid-etched surface implants and new hydrophilic surface implants in the posterior maxilla using a 3-month early-loading protocol: a randomized controlled trial

  • Kim, Hyeong Gi;Yun, Pil-Young;Kim, Young-Kyun;Kim, Il-hyung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.3
    • /
    • pp.175-182
    • /
    • 2021
  • Objectives: In this prospective randomized controlled trial, we measured the primary and secondary stability of two surface-treated implants placed in the posterior maxilla, applied 3-month loading protocols, and compared and analyzed the short-term outcomes of the implants. Patients and Methods: From June 2018 to June 2019, patients with a residual bone height of 4 mm in the posterior maxilla were enrolled and randomly divided into two groups to place SA implants (Osstem Implants, Korea) in Group A and NH implants (Hiossen, USA) in Group B. Finally, 14 implants placed in 13 patients in Group A and 17 implants placed in 14 patients in Group B were analyzed. The measured primary and secondary stability of each implant was represented by implant stability quotient (ISQ), and treatment outcomes were evaluated. Results: Group A consisted of patients with an average age of 62.2 years (range, 48-80 years), and Group B consisted of patients with an average age of 58.1 years (range, 35-82 years). Primary stability was 73.86±6.40 and 71.24±5.32 in Groups A and B, respectively (P=0.222). Secondary stability was 79.07±5.21 in Group A and 78.29±4.74 in Group B (P=0.667). A steep increase in ISQ during the healing period was observed in Group B, though it was not significant (P=0.265). The mean follow-up period was 378.5±164.6 days in Group A and 385.3±167.9 days in Group B. All implants in each group met the success criteria, and the success rate was 100%. Conclusion: Two surface-treated implants placed in the posterior maxilla with greater than 4 mm alveolar bone height exhibited successful one-year treatment outcomes if a primary stability of 65 or higher ISQ was obtained and a 3-month early loading protocol was applied.

Analysis of 1,590 Patients of IV-PCA for Postoperative Pain Management (정맥내 통증 자가조절법에 의한 술후통증관리 1,590예에 대한 분석)

  • Song, Sun-Ok;Jee, Dae-Lim;Koo, Bon-Up
    • The Korean Journal of Pain
    • /
    • v.9 no.2
    • /
    • pp.354-362
    • /
    • 1996
  • Background: We started postoperative pain management service using an intravenous patient-controlled analgesia (IV-PCA, PCA), which is known as convenient and effective analgesic method. In this report, we describe the efficacy and safety of PCA and the experience of developing an acute pain service to treat postoperative pain using a PCA. Methods: Practices of an acute pain service were started at a ward for general surgery after preparation of the standardized protocols for PCA. In each patient, PCA was connected following administration of initial loading doses of analgesics at recovery room after operation. All patients were checked by acute pain service team once or twice daily. The scope of acute pain service was gradually spread to other departments such as orthopedic, thoracic, obstetric and gynecologic departments by requests of patients or surgeons. We managed 1,590 patients during first 22 months. among them, nine hundred seventy two cases were prospectively evaluated for their analgesis efficacy and side effects of PCA. Results: The number of patients was increased day by day. the most common type of operation was gastrectomy (21.6%). Commonly used analgesics were nalbuphine (59%) and morphine (37%). The mean duration of PCA attachment was 3.3 days. The degree of analgesia on operation day was good in 44.8% and tolerable in 52.6% of patients. Only 3.9% of patients complained severe pain during their postoperative periods. One elderly patient experienced respiratory depression (0.06%) owing to accidental misuse of PCA by his relatives. Overall patient's satisfaction was over 93%. Conclusion: According to our experiences, we conclude that PCA is an effective, relatively safe and highly satisfactory method for postoperative pain management. Because of these advantages of PCA, the creation of our acute pain service using a PCA was successful and expanded rapidly.

  • PDF

The Effects of Varying Sampling Flow Rates on the Measurements of Total Nitrate and Sulfate in Dry Acid Deposition

  • Park, Jong-Kil;Kim, Jo-Chun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E1
    • /
    • pp.1-12
    • /
    • 2002
  • One technique for determining dry acid deposition fluxes involves measurement of time - averaged ambient concentrations of dry acid deposition species using filter packs (FP) coupled with estimates of mean deposition velocities for the exposure period. A critical problem associated with filter pack data comparisons between various field sampling networks is the use of diverse sampling flow rates and duration protocols. Field experiments were conducted to evaluate the effects of varying sampling flow rates, from 1.5 to 10 standard liters per minute, on total nitrate and sulfate measurements of specific dry acid deposition species . Collocated FP samplers were used to determine sampling and analysis data reproducibility and representativeness . Ambient air samples were simultaneously collected using groups of filter packs operated at various flow rates over identical 7 day periods. The species measured were sulfur dioxide, particulate sulfate , nitric acid and particulate nitrate. Statistical results (ANOVA; alpha level 5%) showed that neither the low nor high sampling flow rates caused a significant difference in the measurements of total sulfate and adjusted total nitrate (ATN) . However, it was concluded that for high flow rate sampling measurements, total nitrate (TN) could be affected during extended sampling durations because of potential nitric acid overloading and breakthrough. Although the previous workers (Costello, 1990; Quillian, 1990) used much higher sampling flow rates (~ 17 sLpm) than employed here, it was assumed that for a high loading (> 50$\mu\textrm{g}$ HNO$_3$) of nitric acid on the Nylon filters, a significant fraction (~10%) of nitric acid could pass through the Nylon filters and be collected on the carbonate impregnated filters. It was concluded that even at the highest sampling flow rate employed (10 sLpm) at the Cary Forest site, nitric acid breakthrough was less than 10% of the total HNO$_3$ collected. However, for a heavily polluted urban airshed or with longer sampling times , higher filter loadings could result in substantial nitric acid breakthrough and HNO$_3$concentrations would be underestimated.

An advanced key distribution mechanism and security protocol to reduce a load of the key management system (키 관리시스템의 부하절감을 위한 향상된 키 분배 메커니즘과 보안프로토콜)

  • Jeon, Jeong-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.11 no.6 s.44
    • /
    • pp.35-47
    • /
    • 2006
  • In an Ubiquitous Environment, the growth of various services and equipment is forecasted to increase both the multicast users and diverse hacking attacks of the multicast key. Rapid increasing of multicast users and application security protocols reduce the performance of the Central key management system. Accordingly. We propose to elevate the functionality of the key management mechanism for greater efficiency and stability of the multicast services. in this paper The existing key management mechanism comparison and simulation will analyze these problems. We propose the advanced SMKD (Secure Multicast Key Distribution) mechanism application of the small group and key length control new security protocol by methods to solve these problems. The SMKD Model in this paper will help reduce loading the key distribution and encryption execution of a central key management system, and this model can also ensure stability to a central key management system by efficient key management.

  • PDF

Application of dental implant for orthodontic anchorage (보철 수복용 임플란트의 교정치료를 위한 고정원의 활용)

  • Kang, Hyo-Jin;Park, Eun-Jin;Kim, Sun-Jong;Pang, Eun-Kyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.6
    • /
    • pp.404-413
    • /
    • 2016
  • Currently, dental implants have become predictable and reliable adjuncts for oral rehabilitation. Osseointegrated implants can be used to provide rigid orthodontic anchorage and have advantages compared conventional orthodontic anchorage especially when there were edentulous areas and implants were scheduled as a treatment plan. Orthodontic force doesn't cause the bone loss of osseointegrated implants. Implant materials, surgical protocols and healing time before loading follow the conventional treatment protocol. Because the implants, once installed, can't change the location, meticulous treatment planning should be preceded. Further investigations are needed to standardize the treatment protocol.

  • PDF

Short dental implants in the posterior maxilla: a review of the literature

  • Esfahrood, Zeinab Rezaei;Ahmadi, Loghman;Karami, Elahe;Asghari, Shima
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.70-76
    • /
    • 2017
  • The purpose of this study was to perform a literature review of short implants in the posterior maxilla and to assess the influence of different factors on implant success rate. A comprehensive search was conducted to retrieve articles published from 2004 to 2015 using short dental implants with lengths less than 10 mm in the posterior maxilla with at least one year of follow-up. Twenty-four of 253 papers were selected, reviewed, and produced the following results. (1) The initial survival rate of short implants in the posterior maxilla was not related to implant width, surface, or design; however, the cumulative success rate of rough-surface short implants was higher than that of machined-surface implants especially in performance of edentulous dental implants of length <7 mm. (2) While bone augmentation can be used for rehabilitation of the atrophic posterior maxilla, short dental implants may be an alternative approach with fewer biological complications. (3) The increased crown-to-implant (C/I) ratio and occlusal table (OT) values in short dental implants with favorable occlusal loading do not seem to cause peri-implant bone loss. Higher C/I ratio does not produce any negative influence on implant success. (4) Some approaches that decrease the stress in posterior short implants use an implant designed to increase bone-implant contact surface area, providing the patient with a mutually protected or canine guidance occlusion and splinting implants together with no cantilever load. The survival rate of short implants in the posterior edentulous maxilla is high, and applying short implants under strict clinical protocols seems to be a safe and predictable technique.

Cryopreservation of in vitro Grown Shoot Tips of Korean Potato Varieties by Droplet-vitrification

  • Ji-Won Han;Jinjoo Bae;Jae-Young Song;Ho Chul Ko;Sung-Hee Nam;Jung-ro Lee
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2023.04a
    • /
    • pp.33-33
    • /
    • 2023
  • Potatoes are the world's 4th major food crop after maize, rice, and wheat and also are a staple food for 1.3 billion people. Due to their wide adaptability to various environmental conditions, their yeild capacity, and high commercial value, potatoes have contributed to global food security. Many potato germplasms are commonly preserved as whole plants in fields or in storage to maintain their particular genetic combinations. However, field maintenance is expensive and has the risk of potential losses from diseases, pests, plant ageing and climate change. Over the past four decades, meaningful efforts have been made toward the safe long-term conservation of potatoes through cryopreservation methods such as droplet-vitrification. In this study, we tested 4 Korean potato varieties('Golden Egg', 'Golden Ball', 'Ja-Young' and 'Ha-Ryeong') with the modified potato droplet -vitrification protocol. Potato shoot tips are precultured in a sucrose-enriched medium(0.3 and 0.7M for 7 and 17hrs, respectively) and submitted to a loading step with C4 solution for osmoprotection. The treated explants were dehydrated with Plant Vitrification Solution(PVS)2 which is 80% A3 solution in ice for 30 minutes. Thawing and unloading steps were performed with 0.8M sucrose solution for 30 sec(40℃) followed by 30min(25℃, room temperature). In a potato post-culture medium(MS+0.1 mg·L-1 GA3+0.1 mg·L-1 kinetin), we obtained a survival rates of post-thawed explants ranging 16.1-82.2%. The results suggest that modified and optimized protocols are required dependinig on every cultivar, genetic and ecological types. To achieve higher survival and regeneration rates, each step within the cryoprocedure must be carefully optimized.

  • PDF

Practical Application of Cryopreservation of In Vitro Grown Shoot Tips of Strawberry (Fragaria × ananassa Duch.) using Droplet-Vitrification

  • Jinjoo Bae;Young-Yi Lee;Jae-Young Song;Jung-Ro Lee;Munsup Yoon
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2021.04a
    • /
    • pp.36-36
    • /
    • 2021
  • Cryopreservation has been broadly used as an efficient method for a long-term conservation for many types of plants especially vegetatively propagated plants. Among several cryopreservation methods, a droplet-vitrification was the most widely applicable and efficient method. Studies have developed protocols for strawberry using droplet-vitrification method and suggested the practical use of the protocol for large number of germplasm with a little modification. In this study, the droplet vitrification method of shoot tip has been tested on 31 accessions provided around the world. Shoot tips were precultured on Murashige and Skoog (MS) liquid medium supplemented with 0.3~0.5M sucrose. Precultured explants were osmoprotected with loading solution, 35% of PVS3 (C4, 17.5% glycerol and 17.5% sucrose) for 40 min and exposed to dehydration solution, PVS3 (B1, 50% glycerol and 50% sucrose) for 60 min. Then, the explants were transferred onto droplets containing 2.5 uL PVS3 on sterilized aluminum foils prior to direct immersion in liquid nitrogen (LN) for 1hr. The cryopreserved shoot tips were rapidly warmed in a water bath at 40C and then unloaded in MS with 0.8M sucrose for 40 min. The shoot tips were cultured in NH4NO3-free MS post culture medium for 2 weeks. Subsequently, the explants were moved to the MS medium for 6 weeks and evaluated the regrowth rate. By this droplet-vitrification protocol, twenty-four accessions showed at least 40% regrowth rate. Out of 24 accessions, 'Nonsan1ho' had the highest regeneration rate of 85.8% and 'Jumbo pureberry' had the lowest with 42.1%.

  • PDF