• 제목/요약/키워드: loading performance

Search Result 2,637, Processing Time 0.028 seconds

AEffects of Impeller Blade Thickness on Performance of a Turbo Blower (임펠러 블레이드 두께가 터보블로워 성능에 미치는 영향)

  • Park, Jun-Young;Park, Moo-Ryong;Hwang, Soon-Chan;Ahn, Kook-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.5-10
    • /
    • 2010
  • This study is concerned with effects of impeller blade thickness on performance of a turbo blower. This turbo blower is developed as an air supply system in 250 kW MCFC system. The turbo blower consists of an impeller, two vaneless diffusers, a vaned diffuser and a volute. The three dimensional, steady state numerical analysis is simultaneously conducted for the impeller, diffuser and volute to investigate the performance of total system. To consider the non-uniform condition in volute inlet due to volute tongue, full diffuser passages are included in the calculation. The results of numerical analysis are validated with experimental results of thin blade thickness. Total pressure ratio, efficiency, slip factor and blade loading are compared in two cases. The slip factor is different in two cases and the comparison of two cases shows a good performance in thin blade thickness in all aspects.

Performance Analysis of Synchronous Downlink MC-CDMA with Precoding and Frequency Offset

  • Jang, Won-Mee;Lee, Moon-Woo
    • Journal of Communications and Networks
    • /
    • v.9 no.2
    • /
    • pp.192-197
    • /
    • 2007
  • We analyze the performance of code division multiple access (CDMA) system with multicarrier (MC) that employs precoding in synchronous downlink channels. Even though considerable efforts are undergoing for frequency offset estimation and correction, it is inevitable for the system to bear the remaining frequency offset. Therefore it is important to predict accurately the system performance in the presence of the residual frequency offset. We obtain the bit error rate (BER) performance in terms of the number of users, the spreading factor, the number of sub-carriers, and frequency offset. We assume that the spreading factor is equal to the number of sub-carriers, although we can generalize the case. The simulation results show that the BER of MC-CDMA with precoding shows a performance that varies with frequency offset as well as system loading.

A numerical study of scale effects on performance of a tractor type podded propeller

  • Choi, Jung-Kyu;Park, Hyoung-Gil;Kim, Hyoung-Tae
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.2
    • /
    • pp.380-391
    • /
    • 2014
  • In this study, the scale effect on the performance of the podded propeller of tractor type is investigated. Turbulent flow computations are carried out for Reynolds numbers increasing progressively from model scale to full scale using the CFD analysis. The result of the flow calculation for model scale Reynolds numbers agrees well with that of the experiment of a large cavitation tunnel. The existing numerical analysis indicates that the performance of the podded propeller blades is mainly influenced by the advance coefficient and relatively little by the Reynolds number. However, the drag of pod housing with propeller in operation is different from that of pod housing without propeller due to the acceleration and swirl of propeller slipstream which is altered by propeller loading as well as the pressure recovery and friction according to Reynolds number, which suggests that the pod housing drag under the condition of propeller in operation is the key factor of the scale effect on the performance between model and full scale podded propellers. The so called 'drag ratio', which is the ratio of pod housing drag to total thrust of podded propeller, increases as the advance coefficient increases due to accelerated flow in the slipstream of the podded propeller. However, the increasing rate of the drag ratio reduces continuously as the Reynolds number increases from model to full scale progressively. The contribution of hydrodynamic forces, which acts on the parts composed of the pod housing with propeller operating in various loading conditions, to the thrust and the torque of the total propeller unit are presented for a range of Reynolds numbers from model to full scales.

Performance Analysis of Maximum Likelihood Joint Detection for MIMO MC-CDMA Systems (순방향 다중 안테나 MC-CDMA 시스템에서 Maximum Likelihood 합동 검파 성능 분석)

  • Kim, Young-Ju;Song, Hyoung-Joon;Hong, Dae-Sik
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.11
    • /
    • pp.1-8
    • /
    • 2008
  • In this paper, we analyze the symbol error rate (SER) performance of maximum likelihood (ML) joint detection in downlink multiple-input multiple-output (MIMO) multicarrier code division multiple access (MC-CDMA) systems by deriving a tight union bound on the symbol error rate (SER). The union bound for ML joint detection is utilized to demonstrate the performance of MIMO MC-CDMA systems quantitatively in multiuser and frequency selective Rayleigh fading environments. An analysis of the diversity order of the systems shows the effects of multiple users, spread subcarriers, and multiple antennas on the ML joint detection performance. Furthermore, the analysis shows that MIMO MC-CDMA systems without full loading can achieve more diversify than MIMO orthogonal frequency division multiplexing (OFDM) systems.

Effects of sulphuric acid on mechanical and durability properties of ECC confined by FRP fabrics

  • Gulsan, Mehmet Eren;Mohammedameen, Alaa;Sahmaran, Mustafa;Nis, Anil;Alzeebaree, Radhwan;Cevik, Abdulkadir
    • Advances in concrete construction
    • /
    • v.6 no.2
    • /
    • pp.199-220
    • /
    • 2018
  • In this study, the effects of sulphuric acid on the mechanical performance and the durability of Engineered Cementitious Composites (ECC) specimens were investigated. The carbon fiber reinforced polymer (CFRP) and basalt fiber reinforced polymer (BFRP) fabrics were used to evaluate the performances of the confined and unconfined ECC specimens under static and cyclic loading in the acidic environment. In addition, the use of CFRP and BFRP fabrics as a rehabilitation technique was also studied for the specimens exposed to the sulphuric acid environment. The polyvinyl alcohol (PVA) fiber with a fraction of 2% was used in the research. Two different PVA-ECC concretes were produced using low lime fly ash (LCFA) and high lime fly ash (HCFA) with the fly ash-to-OPC ratio of 1.2. Unwrapped PVA-ECC specimens were also produced as a reference concrete and all concrete specimens were continuously immersed in 5% sulphuric acid solution ($H_2SO_4$). The mechanical performance and the durability of specimens were evaluated by means of the visual inspection, weight change, static and cyclic loading, and failure mode. In addition, microscopic changes of the PVA-ECC specimens due to sulphuric acid attack were also assessed using scanning electron microscopy (SEM) to understand the macroscale behavior of the specimens. Results indicated that PVA-ECC specimens produced with low lime fly ash (LCFA) showed superior performance than the specimens produced with high lime fly ash (HCFA) in the acidic environment. In addition, confinement of ECC specimens with BFRP and CFRP fabrics significantly improved compressive strength, ductility, and durability of the specimens. PVA-ECC specimens wrapped with carbon FRP fabric showed better mechanical performance and durability properties than the specimens wrapped with basalt FRP fabric. Both FRP materials can be used as a rehabilitation material in the acidic environment.

Seismic Performance of Shear Dominant Hybrid Steel Link Beam with Circular Web Opening (원형 개구부가 있는 전단지배 하이브리드 강재 연결보의 내진성능)

  • Lim, Woo-Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.30 no.1
    • /
    • pp.37-48
    • /
    • 2018
  • Cyclic loading tests for shear dominant hybrid steel link beams with circular web openings were performed to evaluate the seismic performance. Four half-scaled specimens with bolted connections were tested. The test parameter is a diameter of the web opening, i.e., shear strength ratio ($V_{pw}/V_p$) of the link beam and presence of top-seat angles. Using test results, adequate design shear strength of link beam was finally suggested. Test results showed that when the shear capacity is less than half of the plastic shear strength, seismic performance was improved due to mitigation of pinching under reversed cyclic inelastic deformations.

Performance Evaluation of Advanced Municipal Wastewater Tretment by Phased Isolation Intrachannel Clarifier Ditch (침전지내장형 상분리 산화구공정에 의한 하수 고도처리특성 평가)

  • Hong, Ki-Ho;Chang, Duk;Han, Sang-Bae
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.563-570
    • /
    • 2004
  • Phased isolation intrachannel clarifier ditch process developed in this study is an enhanced biological nutrient removal process employing two ditches with intrachannel clarifiers. Bench-scale phased isolation ditch process was used to evaluate the system performance on municipal wastewater and detailed assessment of internal behavior in a ditch and each reactions. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31 days, and cycle times of 4hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 73~78%, and 65~90%, respectively. The internal behavior were well matched on each reactions such as nitrification, denitrification, and phosphorus release and uptake. As the SRT became longer, TN removal increased gradually, whereas TP removal decreased contrarily. However, the system was capable of producing an effluent TP concentration 1mg/L or less even at longer SRTs except the case of solids discharge by malfunction of intra-clarifier occurred by its geometrical limit. The system performance slightly decreased by hydraulic shock loading(increasing of influent flowrate and decreasing of system HRT). However, the higher system performance could be achieved again after four cycles. Thus, the system reliability could be successfully achieved short-term hydraulic shock loading that occurred in medium- and small-sized wastewater treatment plants suffering fluctuation of influent quality and flowrate during wet season.

Seismic Performance Evaluation of Beam-Column Connection for Panel Zone Strength (패널존의 강도비에 따른 기둥-보 접합부의 내진성능 평가)

  • Kim, Sung-Young;Shin, Chang-Hoon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.1 s.24
    • /
    • pp.11-20
    • /
    • 2007
  • The study proposes the method to cancel the scallop to avoid fracture of the circumstance of the scallop at H shape column-to-beam connection and reinforce at beam flange two faces with the cover plates and rib. A total of four specimens were tested to enhance seismic performance of building structure by reducing the frequency of stress concentration and preventing the brittle fracture of scallop. For this purpose, four full-scale test specimens were made and loaded with quasi-static reversed cyclic loading. The main analytical parameters are panel-zone-strength ratio, yield strengths, initial stiffness, total plastic rotation, contribution of each element to total plastic rotation and energy dissipation capability. For the specimens tested under repeated loading, the experimental result was satisfied with seismic performance requirement as the Special Moment Frames (SMF). The analysis results show that all of the test specimens were found to have good performance to 4% story drift and satisfied the criteria for the plastic roation capacity of SMFs that is 0.03 rad. according to the 1997 AISC seismic provision.

An Analytical Study on Influence of Longitudinal Stiffeners on Seismic Performance of Circular Steel Columns (수직보강재가 원형강기둥의 이력거동에 미치는 영향에 대한 해석적 연구)

  • Jang, Gab-Chul;Chang, Kyong-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.1 s.23
    • /
    • pp.63-70
    • /
    • 2007
  • To improve the land use of urban, Construction of the circular steel column is required recently. The circular steel columns have a advantage for improving a load carrying rapacity as wall as reducing a effective section area. However, the circular steel columns under service load, such as earthquake, shows a tendency to cause local buckling and large deformation. To prevent these phenomena, use of longitudinal stiffeners is considered. The application of longitudinal stiffeners at the circular steel columns is expected to increase a load carrying capacity, buckling strength and seismic performance of circular steel column. However, increasing the loading carving rapacity of buckling which constructed the longitudinal stiffeners, was not investigated yet. Therefore it needs study on effect of longitudinal stiffener in pipe-section steel pier. In this study, the load rallying capacity of buckling of steel pier was investigated by using elastic-plastic finite element analysis considered geometrical and material non-linearity. Also, this study investigated the effect of longitudinal stiffeners on loading carrying capacity of buckling and the relationship between width and thickness of longitudinal stiffeners. And also, a Influence of longitudinal stiffeners on seismic performance of circular steel columns was investigated by numerical analysis

  • PDF

Numerical Analysis of the Outlet Structure Effect on the Flow and Settling Performance of the Rectangular Clarifiers (장방형 2차 침전지 유출부의 구조가 유동 및 성능에 미치는 영향에 대한 수치 해석적 연구)

  • Kim, Youngchul;Park, Moo Jong;Sheen, Dong-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.557-565
    • /
    • 2006
  • Proper operation of clarifier partly depends on outlet conditions. Effluent has to be uniformly withdrawn to prevent scouring of settled sludge and carry over of settling sludge from the clarifier. In this paper, 3-D numerical model was employed to analyze the flow and settling performance of the rectangular clarifier. There were two simulation conditions of which in the same clarifier, the first one was assumed to have a 11.5 meter weir length and the second has 8.5 meters. Shape, location and placement of the weir structure were different, but both of those outlets meet weir loading design criteria. Simulation results indicate that clarifier with longer weir generally gave strong and unstable currents at the mid-stream where the weir starts while in the clarifier with short and relatively simple weir, uniform and stable flow was observed in most parts of the settling zone, and especially at the weir region. These flow conditions affected settling performance. Effulent SS concentration from clarifier equipped with the long and complicated placement of weir was 24.5 mg/L, but 7.0 mg/L from the clarfieir having short weir length. From this study, it can be concluded that as reported from other studies, weir loading does not guarantee settling performance and 3-D numerical model can be a useful tool for determining and validating outlet structure.