• Title/Summary/Keyword: loading performance

Search Result 2,637, Processing Time 0.026 seconds

Particle loading as a design parameter for composite radiation shielding

  • Baumann, N.;Diaz, K. Marquez;Simmons-Potter, K.;Potter, B.G. Jr.;Bucay, J.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3855-3863
    • /
    • 2022
  • An evaluation of the radiation shielding performance of high-Z-particle-loaded polylactic acid (PLA) composite materials was pursued. Specimens were produced via fused deposition modeling (FDM) using copper-PLA, steel-PLA, and BaSO4-PLA composite filaments containing 82.7, 75.2, and 44.6 wt% particulate phase contents, respectively, and were tested under broad-band flash x-ray conditions at the Sandia National Laboratories HERMES III facility. The experimental results for the mass attenuation coefficients of the composites were found to be in good agreement with GEANT4 simulations carried out using the same exposure conditions and an atomistic mixture as a model for the composite materials. Further simulation studies, focusing on the Cu-PLA composite system, were used to explore a shield design parameter space (in this case, defined by Cu-particle loading and shield areal density) to assess performance under both high-energy photon and electron fluxes over an incident energy range of 0.5-15 MeV. Based on these results, a method is proposed that can assist in the visualization and isolation of shield parameter coordinate sets that optimize performance under targeted radiation characteristics (type, energy). For electron flux shielding, an empirical relationship was found between areal density (AD), electron energy (E), composition and performance. In cases where ${\frac{E}{AD}}{\geq}2MeV{\bullet}cm{\bullet}g^{-1}$, a shield composed of >85 wt% Cu results in optimal performance. In contrast, a shield composed of <10 wt% Cu is anticipated to perform best against electron irradiation when ${\frac{E}{AD}}<2MeV{\bullet}cm{\bullet}g^{-1}$.

Experimental and numerical analyses on axial cyclic behavior of H-section aluminium alloy members

  • Wu, Jinzhi;Zheng, Jianhua;Sun, Guojun;Chang, Xinquan
    • Structural Engineering and Mechanics
    • /
    • v.81 no.1
    • /
    • pp.11-28
    • /
    • 2022
  • This paper considers the combination of cyclic and axial loads to investigate the hysteretic performance of H-section 6061-T6 aluminum alloy members. The hysteretic performance of aluminum alloy members is the basis for the seismic performance of aluminum alloy structures. Despite the prevalence of aluminum alloy reticulated shells structures worldwide, research into the seismic performance of aluminum alloy structures remains inadequate. To address this deficiency, we design and conduct cyclic axial load testing of three H-section members based on a reliable testing system. The influence of slenderness ratios and bending direction on the failure form, bearing capacity, and stiffness degradation of each member are analyzed. The experiment results show that overall buckling dominates the failure mechanism of all test members before local buckling occurs. As the load increases after overall buckling, the plasticity of the member develops, finally leading to local buckling and fracture failure. The results illustrate that the plasticity development of the local buckling position is the main reason for the stiffness degradation and failure of the member. Additionally, with the increase of the slenderness ratio, the energy-dissipation capacity and stiffness of the member decrease significantly. Simultaneously, a finite element model based on the Chaboche hybrid strengthening model is established according to the experiment, and the rationality of the constitutive model and validity of the finite element simulation method are verified. The parameter analysis of twenty-four members with different sections, slenderness ratios, bending directions, and boundary conditions are also carried out. Results show that the section size and boundary condition of the member have a significant influence on stiffness degradation and energy dissipation capacity. Based on the above, the appropriate material constitutive relationship and analysis method of H-section aluminum alloy members under cyclic loading are determined, providing a reference for the seismic design of aluminum alloy structures.

Pseudo-Dynamic Test of Circular Reinforced Concrete Bridge Piers for Seismic Performance (원형 콘크리트 교각의 내진거동에 관한 유사동적 실험)

  • 박종협
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.409-416
    • /
    • 2000
  • This research aims at evaluating the seismic performance of the existing R/C bridge piers which were nonseismically or seismically designed in accordance with the provision of Korea Highway Design Specification. Further experimental investigations have been doing to figure out the retrofitting effects of nonseismic R/C bridge piers confined with glass fiber at the plastic hinge zone. Pseudo-dynamic tests have been carried out on nine scaled R/C column specimens to investigate their hysteretic behavior under earthquake loading, Test parameters are axial load input ground motion confinement steel ration glass fiber and etc,

  • PDF

A Study on the Power Supply for Endura Electrodeless Lamp (엔두라 무전극 램프용 전원장치 연구)

  • 한수빈;박석인;정봉만;김규덕;이선근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.15-18
    • /
    • 2002
  • Power supply technique for electrodeless lamps, especially Endura of Osram, is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Less performance but sufficient to predict future success compared to Osram's one is verified as a result of experiment of the prototype.

  • PDF

A Study on the Power Supply for Electrodeless Lamp (무전극 형광등용 전원)

  • Han, Soo-Bin;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.13-16
    • /
    • 2004
  • Power supply technique for electrodeless lamps is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Experiment and performance comparison for both Endura md QL are performed and further study to commercialization are discussed.

  • PDF

Dynamic Analysis for Bridge Using the Experimental Results of Hysteretic Damping Bearing and Dynapot (교량용 내진 받침의 동특성 실험 결과를 이용한 교량의 해석)

  • 윤정방;박동욱;이동하;안창모
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.04a
    • /
    • pp.465-474
    • /
    • 2001
  • Base Isolation system is an effective design strategy that provides a practical substitute for the seismic design of bridge. In this study, the dynamic tests was performed on HDB (Hysteretic Damping Bearing) and Dynapot. Then, the dynamic analysis was carried out for a bridge using the experimental results to estimate the seismic performance of bearings. Analysis for bridge was performed for four types of earthquake loadings. The result of dynamic test and theoretical analysis indicate that the performance of HDB and Dynapot is appropriate for the earthquake loading.

  • PDF

Experimental Study on Active Control of Building Structures by Feedback Variables (피드백 변화에 따른 건물의 능동제어 실험)

  • 민경원
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.286-294
    • /
    • 1998
  • This paper presents an experimental study on the performance of the active damper device by feedback variables. The damper is a mass-typed active device, which exerts the inertia control force on the building by AC servo motor. The control performance is experimentally analyzed considering the building response and the control force. It is found that the building response is greatly reduced by mass-typed device under the resonant and earthquake loading. Also, the experimental results show that the velocity feedback reduces the building responses with the smallest amount of control force than any other feedback variables.

  • PDF

A reliability-based criterion of structural performance for structures with linear damping

  • Kovaleva, Agnessa
    • Smart Structures and Systems
    • /
    • v.2 no.4
    • /
    • pp.313-320
    • /
    • 2006
  • The reliability analysis of structures subjected to stochastic loading involves evaluation of time and probability of the system's residence in a reference domain. In this paper, we derive an asymptotic estimate of exit time for multi-degrees-of-freedom structural systems. The system's dynamics is governed by the Lagrangian equations with linear dissipation and fast additive noise. The logarithmic asymptotic of exit time is found explicitly as a sum of two terms dependent on kinetic and potential energy of the system, respectively. As an example, we estimate exit time and an associated structural performance for a rocking structure.

Effects of elastic foundation on the dynamic stability of cylindrical shells

  • Ng, T.Y.;Lam, K.Y.
    • Structural Engineering and Mechanics
    • /
    • v.8 no.2
    • /
    • pp.193-205
    • /
    • 1999
  • A formulation for the dynamic stability analysis of cylindrical shells resting on elastic foundations is presented. In this previously not studied problem, a normal-mode expansion of the partial differential equations of motion, which includes the effects of the foundation as well as a harmonic axial loading, yields a system of Mathieu-Hill equations the stability of which is analyzed using Bolotin's method. The present study examines the effects of the elastic foundation on the instability regions of the cylindrical shell for the transverse, longitudinal and circumferential modes.

Compressive Properties of Ultra High Strength Concrete Exposed to High Temperature (고온에 노출된 초고강도 콘크리트의 압축특성)

  • Kang, Yong-Hak;Kang, Choong-Hyun;Choi, Hyun-Guk;Shin, Hyun-Jun;Kim, Wha-Jung
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.3
    • /
    • pp.377-384
    • /
    • 2014
  • Recently, the trend toward larger architectural structures continues and accelerates demand for Ultra High Strength Concrete (UHSC) which satisfies structural performance. However, UHSC has weakness in fire and the performance tests are required. In this paper, the change of mechanical properties of 100 MPa grade UHSC exposed to high temperatures ($20^{\circ}C{\sim}800^{\circ}C$) was observed to develop high temperature material model of UHSC: residual compressive strength, modulus of elasticity, property of stress-strain on monotonous loading and property of stress-strain on cyclic loading. In addition, TG/DTA and SEM Images analyses were performed to investigate chemical and physical characteristics of UHSC, and the results of this research were compared with those of previous studies. As a result, UHSC at the heating temperature of $300^{\circ}C$ showed a sharp decrease of residual compressive strength and modulus of elasticity. And It was shown that UHSC had a plastic behavior at more than $400^{\circ}C$ on the cyclic loading and revealed a same tendency in both monotonous and cyclic loading of all heating temperatures. In addition, through TG/DTA and SEM images analyses compared with those from previous studies, it was shown that the deterioration of concrete inner tissue, water evaporation and chemical reaction caused the decrease of residual compressive strength and modulus of elasticity.