• Title/Summary/Keyword: loading performance

Search Result 2,636, Processing Time 0.035 seconds

Pyroshock and Vibration Isolation using SMA Mesh Washer Isolator (형상기억합금 메쉬 와셔 절연계의 파이로 충격 및 진동 절연 시험)

  • Youn, Se-Hyun;Jang, Young-Soon;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.3
    • /
    • pp.307-313
    • /
    • 2009
  • In general, pyroshock is generated from the actuation of separation devices for several stage, fairing, and satellite separation in the flight of a launch vehicle. During these events, transient vibration phenomenon called pyroshock, which shows large acceleration in the high frequency range, occurs and it can result in the malfunction of electronic components which is equipped inside the launch vehicle or satellite. In this paper, mesh washer isolators made out of SMA were introduced for the isolation of pyroshock. One type of isolator primarily used pseudoelastic characteristics of SMA and the other type of isolator used shape memory effect of SMA. For the study of basic load-displacement relationship of each SMA isolator, compressive loading tests were performed and the results showed the capability of the isolator itself. Pyroshock isolation tests were followed and verified the outstanding isolation performance of isolator. In addition, random vibration tests were also performed and checked the dynamic characteristics of each SMA isolator.

An Experimental Study on the Fatigue Behaviors Strengthened by Ventilation-Glass Fiber Plate of Reinforced Concrete Beams (철근콘크리트 보의 통기성 유리섬유판 보강에 따른 피로거동에 관한 실험적 연구)

  • Kim, Woonhak;Kang, Seokwon;Shin, Chunsik
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.391-400
    • /
    • 2012
  • Recently, the construction industry commonly uses FRP as a reinforcement material because of its material advantages. FRP attached reinforcement has various advantages such as high strength, stiffness, excellent durability and construction practicability comparing to its weight. However, external attachment of FRP is water-tighted with low water permeable material, not draining water, probably causing damages on a permanent structure. The study manufactured it through pultrusion and examined GP(glass fiber panel) of which material-mechanical properties are almost same as the existing FRP but durability and attachment performance are better by stationary experiments, testing load-deflection curve, destruction types and load-deflection relation under repetitive loading test. As a result of 2,000,000 fatigue tests, it did not result in the destruction and showed excellent permanent attachment and durability as it displays significantly low compressive strain of concrete.

Access Control using Secured Container-based Virtualization (보안 컨테이너 가상화 기반 접근 제어)

  • Jeong, Dong-hwa;Lee, Sunggyu;Shin, Youngsang;Park, Hyuncheol
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.330-334
    • /
    • 2017
  • Container-based virtualization reduces performance overhead compared with other virtualization technologies and guarantees an isolation of each virtual execution environment. So, it is being studied to block access to host resources or container resources for sandboxing in restricted system resource like embedded devices. However, because security threats which are caused by security vulnerabilities of the host OS or the security issues of the host environment exist, the needs of the technology to prevent an illegal accesses and unauthorized behaviors by malware has to be increased. In this paper, we define additional access permissions to access a virtual execution environment newly and control them in kernel space to protect attacks from illegal access and unauthorized behaviors by malware and suggest the Container Access Control to control them. Also, we suggest a way to block a loading of unauthenticated kernel driver to disable the Container Access Control running in host OS by malware. We implement and verify proposed technologies on Linux Kernel.

  • PDF

A Study of Noise Characteristics Induced by Slab Vibration for the Elevated Railway Station (선하역사의 슬래브 진동에 의한 소음방사 특성에 관한 연구)

  • Kim, Jin-Ho;Jang, Dongdoo;Ji, Yong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3557-3566
    • /
    • 2015
  • In the case of elevated railway station in which railway is connected with superstructure of station, vibration and noise level is relatively higher than those of general structure type station due to structural characteristic which transmits vibration directly. Therefore, characteristic understanding of structural vibration and accompanying structure cause noise and establishment of reduction plan through the results are in need. Test and analysis are performed in this research to consider correlativity between structural vibration and accompanying structure cause noise when external forces are applied on standard slab and floating slab which is able to isolate vibration. By producing and loading on standard and floating slab, vibration and noise response are measured while simulation using numerical analysis, finite element method and SEA method is performed. The results about structural dynamic behavior of slab, correlativity between structural vibration and noise, reduction performance of floating slab is deduced through the analysis of tests.

Impact Factor Analysis of Response Adjustment Factor of PSC Composite Bridge Using Optical Fiber Sensor (광섬유 센서를 이용한 PSC 합성형교의 응답보정계수 영향인자 분석)

  • Kim, Ho Sun;Jang, Hwa Sup;Yang, Dong Woon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • In general, load carrying capacity, one of the load & resistance capacities in bridges, has more margins than the load carrying capacity evaluated with theoretical methods, unless there are severe damages, defects or material deterioration phenomena that can have a great impact on the behavior of bridges. However, errors have been already included in the current processes of loading tests and structural analysis for measuring load carrying capacity, thus devaluing the reliability of response adjustment factor. Therefore, this study found out the problems of existing electric resistance strain and displacement sensors in sensor suite to solve the problems with sensors and the errors in the appropriateness of structural analysis model, thereby leading to the changes into an optical fiber smart sensor with excellent performance. Besides, the study attempted to ensure the accuracy of response adjustment factor by selecting the optimal models through the interpretation of various structural analysis models.

Verification on the Compressive Behavior of Corrugated Steel Plates due to Details of Bolted Lap Joint (압축하중을 받는 파형강판 연결부 상세에 따른 구조거동 분석)

  • Oh, Hong Seob;Nam, Ki Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.9-17
    • /
    • 2012
  • This study is dealt with the experimental seam strength of deep corrugated steel plate which is used as underpasses, storm sewers and other buried applications. The soil-metal structure using deep corrugated plate should be sufficient to ensure safety for compressive loading. The experimental and theoretical results on the seam strength are accumulated enough to take the design guideline, even if the seam strength at the bolt connected lap joint in construction site can be varied depending on the connection detailing and the thickness of plate. In this study, compressive behavior of bolted lap jointed plates using various connection detail such as gasket, slot hole, washer was experimentally analyzed. From the test, failure pattern with an increases in the thickness of specimens was changed from plate bearing to bolt shearing. In case of thicker plates than 6.0mm, the structural performance of lap joint using gasket and slot hole is more effective than it of the plate adopted washer.

Improvement of Methanogenic activity in the Anaerobic Treatment of Wastewater with High Sulfate (고농도 황산염을 함유한 폐수의 혐기성 처리시 메탄균의 효율 향상을 위한 연구)

  • Shin, Hang Sik;Oh, Sae Eun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.2
    • /
    • pp.47-54
    • /
    • 1996
  • UASB reactor was operated for treating wastewater containing high sulfate to assess their performance, competition between sulfate-reducing bacteria(SRB) and methane-producing bacteria(MPB), and the change in the characteristics of microbial granules according to change of hydraulic retention time(HRT) in the reactor. The reactor was fed with a synthetic moderate strength wastes(glucose, 2000 mgCOD/l) containing high sulfate($2400mgSO_4{^{2-}}/l$). The organic loading rate(OLR) ranged from 1.5 to 3.0 gCOD/l.d as HRT maintained 15 to 30 hrs in the stage I. The COD removal efficiency was between 80 to 92%. During this period, methane yield rapidly decreased from 0.3 to 0.1 1 $CH_4$/gCODremoved. While sulfide concentration in the effluent increased from 80 to 200 mgS/l. This indicates that SRB becomes dominant over MPB at a relatively long HRT in the excess sulfate. When OLR of reactor maintained from 5 to 8 gCOD/l.d in the stage II, methane yield increased from 0.1 to 0.17 1 $CH_4$/gCODremoved regardless of decrease of COD removal efficiency. This indicates that SRB is more sensitive to the change of a short HRT than MPB. In the competition between SRB and MPB, about 30% of the removed COD was utilized by SRB at HRT of 30 hrs during the start-up period, while about 73% was used by SRB at HRT of 15hrs at the final step of second experimental stage. Whereas after shock exposure of OLR about 62% was utilized by SRB at HRT of 5hrs. It indicates that SRB is strongly suppressed by the wash-out of significant dispersed SRB since a large electron flow is distributed to the MPB. In addition, the granulation in the presence of high sulfate is unfavoured at a long HRT because of substrate transport limitations into MPB like Methanothrix spp. which is an important factor in the composition of the granules. Accordingly, granule sizes in the UASB reactor decreased with time due to weak network frame of granules by the decreased activity of MPB.

  • PDF

Performance Study on Pilot-scale Constructed Wetlands in order to Restore Contaminated Stream (오염하천의 정화를 위한 파일럿 규모의 인공습지 적용)

  • Kim, Seung-Jun;Choi, Yong-Su;Bae, Woo-keun
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.3
    • /
    • pp.546-556
    • /
    • 2006
  • The purpose of this study is to improve the polluted stream water quality by pilot-scale five different constructed wetlands (CWs). Cell 1 to 3 are newly designed 2SFCW (Surface-subsurface flow CW) with 1 to 3 flow shifters (FS) in the middle of the wetland system. Cell 4 and 5 are control CW (CCW), but Cell 5 is the same type as Cell 3. The FS, which converts the route of surface and subsurface flow between two wetlands connected in series, was able to enhance the treatability of TN via nitrification and denitrification and of SS due to filtration and sedimentation. The void fraction and dispersion number of Cell 1, 2 and 3 obtained from the RTD analysis were found to be 0.73 and 0.17, respectively. COD and TP removal efficiencies of Cell 1 to 3 were similar to that of Cell 4 and 5. SS removal efficiencies of Cell 1 to 3 and 5 with FS were 5-10% higher than that of Cell 4 without FS. TN removal efficiencies of Cell 1 to 3 were 3-14% higher than that of Cell 4 and 5. The average $R^2$ values of COD, SS, TN and TP obtained from nonlinear regression analysis were similar to the results of other researchers.

Effect of Hydraulic Loading Rate of a Continuous Stirred Tank Reactor(CSTR) on the Removal Efficiency of Pollutants of Pig Slurry (CSTR의 수리학적 부하율이 돈슬러리의 유기물 및 영양염류 저감효율에 미치는 영향)

  • 정우철;최홍림
    • Journal of Animal Environmental Science
    • /
    • v.5 no.3
    • /
    • pp.189-196
    • /
    • 1999
  • Anaerobic digestion is a naturally occuring microbial process involving the decomposition of organic materials such as livestock manure. This study explores the effect of the operating conditions, HRT (Hydraulic Retention Time) and feeding frequency on treatment efficiency for digestion of pig slurry, which has been one of most difficult organic waste for proper treatment in livestock production industry in Korea at the present time. The pilot-scale CSTR of 5 m3 in volume was designed. manufactured, and operated at the temperature of 35$\pm$1$^{\circ}C$. The digester was designed to hydraulically stir for complete mixing and to supply heat from the water bath to maintain mesophilic temperature. The HRT of the digester for Test 1 and Test 2, and Test 3 was set for 17 days and 13 days respectively and pig slurry was fed once a day with 300$\ell$ each for Test 1 and Test 3, while twice with 150$\ell$each for Test 2. Test 2 showed better performance by increase of 4% in VS removal efficiency and 5% in biogas production rate. This is mainly attributed to smaller temperature drop by feeding frequently with half amount, which eventually led to lesser impact on anaerobic mocrobes in the digester. Test 2 maintained optimum pH 7.8 which uplifted the activaton of sulfur-reduction bacteria, alkalinity of around 4,000mg/$\ell$, VA of over 3,000mg/$\ell$ for whole period of experiment. Further research may require to provide the practical operation strategy of anaerobic treatment system for treatment of pig slurry.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.