• 제목/요약/키워드: loading height

검색결과 524건 처리시간 0.028초

가방 하중의 크기와 방식에 따른 척추 정적 자세의 변화 (Alteration of the Static Posture of Spine under Different Types and Amounts of Loading)

  • 박용현;김영관;김윤혁
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.230-236
    • /
    • 2011
  • The aim of this study was to investigate the alteration of lumbar spine and trunk postures on different load-carrying types and amounts under static loading. Two load-carrying types(unilateral carrying: UC vs. bilateral carrying: BC) and four different loads(0, 5, 10, and 15 kg) were randomly tested in this study. Carrying a heavy bag would affect human body posture, specifically lumbar spine curvature, which is considered as one of sources of back problems. Previous studies have not paid attention to the approach of the multisegment model of the lumbar spine and trunk. This study separated two compartments of trunk segment(the lumbar and thorax) in the analysis. The multisegment model of the lumbar spine in addition to Helen-Hayes marker set was used. Eight motion analysis cameras and a force plate were utilized. Ten male subjects(mean mass, $70.6{\pm}3.97$ kg; mean height, $178{\pm}4.18$ m) having no musculoskeletal disease participated in this study. We analyzed trunk angles in three anatomical planes and the spinal curvature in sagittal and frontal planes. Increased loading in both UC and BC significantly resulted in increases in trunk forward lean but only UC induced increases in trunk lateral lean. In addition, increased loading in BC produced flatten lumbar curvature in sagittal plane. As far as coupling motion, subjects tended to use axial rotation of the lumbar spine in transverse plane in response to increased UC loading. Finally, it is concluded that the increased static loading in UC rather than in BC tends to causes combined alterations of the spinal postures(sagittal and transverse planes together), which would be vulnerable to improper mechanical stresses on the spine.

진동대시험을 이용한 콘크리트 표면 차수벽형 석괴댐의 내진성능 평가 (Evaluation of Resistance of Concrete-Face Rockfill Dam to Seismic Loading Using Shaking Table Test)

  • 하익수;김용성;서민우;박동순
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1118-1125
    • /
    • 2005
  • In this study, seismic safety of CFRD(Concrete-Face Rockfill Dam) type "D" dam in operation is evaluated from the results of 1-g shaking table test using similitude laws. Model dam is made by similitude law considering the grain size of prototype dam component. After the model dam is impounded to the normal water level(N.W.L), it is excited by artificial earthquake wave corresponding to standard design respond spectrum of the "D" dam site. Displacement response behavior of the dam is examined through the measurement of vertical and horizontal displacement of dam crest. Also, amplification characteristics of acceleration with dam height is examined through the measurement of acceleration with dam height. Finally, the purpose of this study is to evaluate seismic safety of "D" dam in operation. From the results of acceleration measurement, it was found that acceleration of dam crest was amplified about 1.52 times compared to the acceleration of dam bottom and amplification phenomenon is outstanding at three quarters of dam height from the bottom of dam. From the analysis of displacement behavior, it was estimated that vertical displacement of prototype dam is 6.8cm (0.1% of dam height) and horizontal displacement 12.3cm(0.2% of dam height). These percentages is much lower than 1% of dam height(general stability criteria). Therefore, it was concluded that seismic stability of "D" dam against an estimated earthquake is guaranteed.

  • PDF

Effect of height-to-width ratio on composite wall under compression

  • Qin, Ying;Yan, Xin;Zhou, Guan-Gen;Shu, Gan-Ping
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.507-519
    • /
    • 2020
  • Double skin composite walls are increasingly popular and have been applied to many safety-related facilities. They come from the concept of composite slabs. Conventional connectors such as shear studs and binding bars were used in previous studies to act as the internal mechanical connectors to lock the external steel faceplates to the concrete core. However, the restraint effects of these connectors were sometimes not strong enough. In this research, a recently proposed unique type of steel truss was employed along the wall height to enhance the composite action between the two materials. Concrete-filled tube columns were used as the boundary elements. Due to the existence of boundary columns, the restraints of steel faceplates to the concrete differ significantly for the walls with different widths. Therefore, there is a need to explore the effect of height-to-width ratio on the structural behavior of the wall. In the test program, three specimens were designed with the height of 3000 mm, the thickness of 150 mm, and different widths, to simulate the real walls in practice. Axial compression was applied by two actuators on the tested walls. The axial behavior of the walls was evaluated based on the analysis of test results. The influences of height-to-width ratio on structural performance were evaluated. Finally, discussion was made on code-based design.

2경간 P.S. 연속합성보 교량의 설계에 관한 연구 (A Study on the Design of Two-Span Continuous P.S. Composite Bridges)

  • 구민세;신동기;이재혁
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1995년도 봄 학술발표회 논문집
    • /
    • pp.203-210
    • /
    • 1995
  • A construction method for continuous prestressed Composite Bridges(PCB's) is developed and successfully applied to the design of two-span continuous PCB's of five different span lengths. The construction of continuous PCB's goes through 17 different loading conditions. for each loading condition, the allowable stress design method is used to determine section properties. The analytical results of two-span continuous PCB's arc compared with those of simple PCB's. The comparison shows that the use of the proposed method can reduce 10-15 percents of the concrete section area and approximate 28 percents of the steel section area, as well as 5-8 percents of the girder height. The study indicates that the use of the proposed PCB's method can significantly reduce construction and maintenance costs of bridges.

  • PDF

비행시험 자료를 이용한 경항공기의 조종력 시뮬레이션 (Simulation of the control force of the light aircraft using flight test data)

  • 김정환;황명신;이정훈
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.203-206
    • /
    • 1996
  • The purpose of this paper is to find how to determine the parameters of the basic control system design such as hinge moment coefficients and to display the controllability of the ChangCong-91. Since the estimation from the flight test of real aircraft is the most reliable, we performed the flight test of ChangGong-91 to get the various parameters such as velocity, height, control force, control surface deflection, 3 axis acceleration, 3 axis angular rate, pitch angle, angle of attack temperature and so on. We recorded the flight test data in VHS tapes and stored them to personal computer using A/D(analog to digital) converter. Flight test was done in various conditions, and the acquired data was processed with parameter identification method such as least square method. These data will be utilized for the development of Autopilot System design and Control Loading System design.

  • PDF

반복 하중을 받는 철근콘크리트 기둥의 소성힌지 길이 (Length of Plastic Hinge in RC Columns under Cyclic Loading)

  • 박종욱;최임준;문초화;이정윤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.11-12
    • /
    • 2009
  • 전단 경간비가 작은 철근콘크리트 기둥은 주 인장근이 항복 한 후 전단에 지배를 받게 되고 축력의 영향으로 인해 에너지 소산 능력이 현저하게 줄어든다. 이러한 과정은 소성힌지 영역에서 일어나게 되는데, 전 구간에 걸쳐서 동시에 발생하지 않고 에너지가 집중되는 곳에서부터 점진적으로 일어나게 된다. 본 연구는 실험을 통해서 반복하중을 받는 철근콘크리트 기둥의 소성힌지 길이 변화를 파악하고자한다.

  • PDF

굽힘-비틀림 복합하중을 받는 복합재료 구조물의 최적 강건 설계 (Robust Design of Composite Structure under Combined Loading of Bending and Torsion)

  • 윤지용;오광환;남현욱;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.211-214
    • /
    • 2005
  • This research studied robust design of composite structure under combined loading of bending and torsion. DOE (Design of Experiment) technique was used to find important design factors. The results show that the beam height, beam width, layer thickness and stack angle of outer-layer are important design parameter. The $2^{nd}$ DOE and RSM (Response Surface Model) were conducted to obtain optimum design. Multi-island genetic algorithm was used to optimum design. An approximate value of 6.65 mm in deflection was expected under optimum condition. Six sigma robust design was conducted to find out guideline for control range of design parameter. To acquire six sigma level reliability, the sigma level reliability, the standard deviation of design parameter should be controlled within 2.5 % of average design value.

  • PDF

재하상태에 따른 철근콘크리트 보의 탄소섬유쉬트 보강효과 (CFS Strengthening Effect of Reinforced Concrete Beams under Loading States)

  • 김민수;오용복;권영웅
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.757-762
    • /
    • 2000
  • The target of this study is to compare and analyze the strengthening effect of damaged reinforced concrete beams under unloading and loading conditions through the simulation of strengthening condition in real structures. The conclusion of test results are as follows : For the concrete beam wrapped at the side in addition to be strengthened at the bottom, the strength and stiffness increase. although the flexural capacity depends on the strengthening method, it generally shows that the strength improve in the range of 22% to 39% in comparison with the specimen without strengthening. In case of applying th equation suggested by CangaRao & Vijay for the wraped concrete beam, it must be modified because it is likely to overestimate the flexural capacity considering the height of wrapping as the width of concrete. The strength an stiffness of reinforced concrete beams in proportion to the percentage of damage decrease. Damaged beams, which are strengthened by CFS, is structurally efficient and show reduction of strength comparing with the specimen without strengthening but stiffness is increasing.

  • PDF

알루미늄봉을 이용한 셀(Cell) 채움재의 전단거동에 관한 연구 (A Study on Shear Behavior of Fill in Cellular Bulkhead by Two Dimensional Model Test with Aluminium Rods)

  • 장정욱
    • 한국지반공학회지:지반
    • /
    • 제12권5호
    • /
    • pp.55-62
    • /
    • 1996
  • Lateral loading model tests were performed on the rigid box-shaped cellular bulkhead by displacement-controlled method. The materials of ground and fill used in this study are two aluminium rods with different sections. The behalf·iotas of ground and fill were recorded by photo/video techniques and failure mechanism created in ground and fill has been simulated two-야mensionally. Also the theoretical consideration about the test results was done on the basis of Hansen's earth pressure theory. As a result, the shape of sliding face the location of sliding face and the loading height was also investigated.

  • PDF

Meteorological events causing extreme winds in Brazil

  • Loredo-Souza, Acir M.
    • Wind and Structures
    • /
    • 제15권2호
    • /
    • pp.177-188
    • /
    • 2012
  • The meteorological events that cause most strong winds in Brazil are extra-tropical cyclones, downbursts and tornadoes. However, one hurricane formed off the coastline of southern Brazil in 2005, a tropical storm formed in 2010 and there are predictions that others may form again. Events such as those described in the paper and which have occurred before 1987, generate data for the wind map presented in the Brazilian wind loading code NBR-6123. This wind map presents the reference wind speeds based on 3-second gust wind speed at 10 m height in open terrain, with 50-year return period, varying from 30 m/s (north half of country) to 50 m/s (extreme south). There is not a separation of the type of climatological event which generated each registered velocity. Therefore, a thunderstorm (TS), an extra-tropical pressure system (EPS) or even a tropical cyclone (TC) are treated the same and its resulting velocities absorbed without differentiation. Since the flow fields generated by each type of meteorological event may be distinct, the indiscriminate combination of the highest wind velocities with aerodynamic coefficients from boundary layer wind tunnels may lead to erroneous loading in buildings.