• Title/Summary/Keyword: loading BOD

Search Result 237, Processing Time 0.263 seconds

Stability Evaluation of Phased Isolation Intra-Clarifier Ditch Process on Short-Term Hydraulic Shock Loading (단기 수리학적 충격부하시 침전지 내장형 상분리 산화구공정의 처리 안정성 평가)

  • Hong, Ki-Ho;Chang, Duk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.791-799
    • /
    • 2005
  • The phased isolation intra-clarifier ditch system used in this study is a simplified novel process enhancing simultaneous removal of biological nitrogen and phosphorus in municipal wastewater in terms of elimination of additional pre-anaerobic reactor, external clarifier, recycle of sludge, and nitrified effluent recirculation by employing intrachannel clarifier. Laboratory-scale phased isolation ditch system was used to assess the treatability on municipal wastewater. When the system was operated at the HRTs of 6~12hours, SRTs of 9~31days, and cycle times of 2~8hours, the system showed removals of BOD, TN, and TP as high as 88~97%, 70~84%, and 65~90%, respectively. The rainfall in Korea is generally concentrated in summer because of site-specific characteristics. Especially, the wet season has set in on June to August. In combined sewers, seasonal variations are primarily a function of the amount of stormwater that enters the system. In order to investigate the effect of hydraulic shock loading on system performance, the laboratory-scale system was operated at an HRT of 6hours (two times of influent flowrate) during two cycles (8hours). The system performance slightly decreased by increasing of influent flowrate and decreasing of system HRT. Nitrification efficiency and TN removal were slightly decreased by increasing of influent flowrate (decreasing of system HRT), whereas, the denitrification was not affected by hydraulic shock loading. However, the higher system performance could be achieved again after four cycles. Thus, the phased isolation technology for enhanced biological nutrient removal in medium- and small-scale wastewater treatment plants suffering fluctuation of influent quality and flowrate.

A Study on BASINS/WinHSPF for Evaluation of Non-point Source Reduction Efficiency in the Upstream of Nam-Han River Watershed (BASINS/WinHSPF를 이용한 남한강 상류 유역의 비점오염원 저감효율평가)

  • Yoon, Chun-Gyeong;Shin, Ah-Hyun;Jung, Kwang-Wook;Jang, Jae-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.951-960
    • /
    • 2007
  • Window interface to Hydrological Simulation Program-FORTRAN (WinHSPF) developed by the United States Environmental Protection Agency (EPA) was applied to the upstream of Nam-Han river watershed to examine its applicability for loading estimates in watershed scale and to evaluate non-point source control scenarios using BMPRAC in WinHSPF. The WinHSPF model was calibrated and verified for water flow using Ministry of Construction and Transportation (MOCT, 3 stations, 2003~2005) and water qualities using Ministry of Environment (MOE, 5 station, 2000~2006). Water flow and water quality simulation results were also satisfactory over the total simulation period. But outliers were occurred in the time series data of TN and TP at some regions and periods. Therefore, it required more profit calibration process for more various parameters. As a result, all the study was performed within the expectation considering the complexity of the watershed, pollutant sources and land uses intermixed in the watershed. The estimated pollutant load for annual average about $BOD_5$, T-N and T-P respectively. Nonpoint source loading had a great portion of total pollutant loading, about 86.5~95.2%. In WinHSPF, BMPRAC was applied to evaluate non-point source control scenarios (constructed wetland, wet detention ponds and infiltration basins). All the scenarios showed efficiency of non-point source removal. Overall, the HSPF model is adequate for simulating watersheds characteristics, and its application is recommended for watershed management and evaluation of best management practices.

Optimum Configuration, Filter Media Depth and Wastewater Load of Small-scale Constructed Wetlands for Treating the Hydroponic Waste Solution in Greenhouses (시설하우스 폐양액 처리를 위한 소형 인공습지의 최적 조합방법, 여재깊이 및 폐양액 부하량)

  • Park, Woo-Young;Seo, Dong-Cheol;Lim, Jong-Sir;Park, Seong-Kyu;Cho, Ju-Sik;Heo, Jong-Soo;Yoon, Hae-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.217-224
    • /
    • 2008
  • To obtain optimum configuration, depth and load of constructed wetlands(CWs) for treating of hydroponic waste solution(HWS) which was produced in greenhouses, the study was conducted with 4 kinds of combined systems such as Vertical flow(VF)-Horizontal flow(HF), VF-VF, HF-VF and HF-HF CWs. In four configurations of CWs, the treatment efficiency of pollutants from HWS under depth of HF and VF beds, HWS loading and HWSs were investigated. Removal rate of pollutants under different depth of VF and HF in 2-stage hybrid CWs was in the order of 50 cm < 70 cm regardless of CWs configuration. Removal rate of pollutants under HWS loading in 2-stage hybrid CWs was in the order of $150L\;m^{-2}\;day^{-1}{\fallingdotseq}300L\;m^{-2}\;day^{-1}\;>\;450L\;m^{-2}\;day^{-1}$. The optimum depth and HWS loading were 70 cm and $300L\;m^{-2}\;day^{-1}$ in four configurations of CWs, respectively. Using this optimum condition, for various HWSs (cucumber, paprika and strawberry HWS), removal rate of pollutants in HF-HF CWs was higher than that in HF-VF CWs. Optimum configuration of 2-stage hybrid CWs for treating hydroponic waste solution in greenhouses was found out to be HF-HF CWs. Therefore, under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P in HF-HF CWs were 84, 81, 84, 51 and 93%, respectively.

A Study on Process Improvement for Reduction of Pollution Loading Rate in Small Individual Sewage Plant (소규모 개인하수처리시설의 MBR공정 적용에 관한 연구)

  • Eom, Han Ki;Choi, Yoo Hyun;Joo, Hyun Jong
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.323-329
    • /
    • 2016
  • In this study, the applicability of MBR process was evaluated to improve processing of personal sewage treatment facilities of $50m^3/day$ or less. As result of the research, stable discharge water quality could be secured as result of the MBR effector operation according to rate of inflow and inflow load and treatment efficiency of 98% or higher was shown by the membrane filtering method operation for SS, $BOD_5$. it was found that high treatment efficiency of 99% or higher. It is judged that detention time can be designed until 6.9 hr when applying MBR process on personal sewage treatment facilities with high pollution load and that cutback of pollution load can be possible through this study. It was shown that MBR process application reduces an annual cost of 4,829,600 won based on the basic unit calculation results and solves burden of amount of borne by causers according to excess of discharge water quality standards.

Effects of Algae Growth on the Effluent of Wastewater Treatment Systems by Using Water Hyacinth (조류 성장이 부레옥잠을 이용한 폐수처리공법의 유출수에 미치는 영향)

  • Lee, Byung-Hun;Lee, Nam-Hee;Kim, Jeong-Suk
    • Journal of Environmental Science International
    • /
    • v.1 no.2
    • /
    • pp.81.2-92
    • /
    • 1992
  • Growing algae spread over open water surface of water hyacinth system the leaves of hyacinth prevented the passage of sunlight through the water surface. The objectives of this study were to investigate the effects of the algae growth on the effluent of water hyacinth wastewater treatment systems operated with the variation of an organic loading rate between 190 to 550 kg COD/ha.day. The effluent from the system contained algae was discharged for about 2-3 weeks from the beginning of experimental operation of water hyacinth systems. BOD and 55 concentration of effluents during algae growthing periods were higher than those during the period of algae control. But nitrogen and phosphrous romoval efficiencies during in algae growthing periods were slighty higher than those during the period of algae control.

  • PDF

Characteristics of Pollutant Loads and Water Quality in Kwangyang Bay, Korea

  • Lee Dae-In;Park Chung-Kil;Cho Hyeon-Seo
    • Fisheries and Aquatic Sciences
    • /
    • v.6 no.3
    • /
    • pp.149-154
    • /
    • 2003
  • The characteristics of pollutant loads from the various sources and seawater quality in Kwangyang Bay were evaluated. Total flow rate was estimated to be $10,868,066.8 m^3/day$ with a flow rate of R2l (the Seomjin River) as the highest one. Total COD, TN and TP loads of the input rivers and the ditches were about 27,591.8, 25,029.6 and 586.4 kg/day, respectively. Wastewater discharging loads was the greatest contributors to pollutant loads in the inner part of Kwangyang Bay. COD values in the inner part of the bay was over 3.0 mg/L, which exceeded the seawater quality criteria III of Korea. The average values of DIN and DIP were 8.62 ${\mu}gN/L\;and\;1.26\;{\mu}gP/L$, respectively. The limiting factor for algal growth was DIN. In he total discharging loads of the watershed from unit loading estimations, BOD, TN and TP were 9,132.3, 2,727.2 and 304.2 kg/day, respectively. In addition, municipal sewage by the population as pollution sources and the city of Kwangyang as administrative district had the highest loads. For a appropriate water quality recovery of Kwangyang Bay, it is suggested that it is essential to estimate reduction rate of total pollutant loads by water quality modeling.

The study for Biological nutrient removal of High-strength nitrogen loading rate using B3 pilot plant (B3 Pliot plant를 이용한 고농도 질소부하에서의 고도처리에 관한 연구)

  • Eorn Tae-Kyu;Han Dong-Yueb;Kim Boo-Gil
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.771-775
    • /
    • 2005
  • The purpose of this research was to investigate applicative possibility of field. Pilot-scale experiments were conducted, at outdoor temperature, HRT l0hour, IR(Internal Recycle) $150\%$ and used $2.8m^3$ Reactor. External carbon source was varied 80 to 120 mg/L. When External carbon source and Alkalinity were injected to the B3 pilot plant, the removal efficiencies of COD and BOD were not decreased. Nitrification rate were 5.95, 5.40, 4.08 $mgNH_4^+-N/gSS/d$ during operation periods and denitrification rate was $3.l2mgNO_3^--N/gSS/d.$ When we surveyed the relationship between loading rate of nitrogen and nitrogen removal quantity, this data was 0.949, B3 process will be possible application process of field.

Pollutants Unit Loadings of the Stormwater Runoff in Industrial Complex (강우시 산업단지에서의 유출오염부하량 원단위 산정)

  • Lee, Jun-Ho;Bang, Ki-Woong;Choi, Jong-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.355-362
    • /
    • 2000
  • The objective of this paper is to estimate the pollutant load based on event mear concentrations(EMC) in industrial complex. Eight sub-basins in the Chongju industrial complex were selected for sampling and study with different characteristics during the period from June 1997 to August 1998. During the storm events, measured EMC ranges of $BOD_5$, COD, SS, TKN, TP, HEM, $NO_3-N$, $PO_4-P$, Cr, Pb, Cu and Fe in the industrial complex watersheds were 11~176mg/L, 40~502mg/L, 23~633mg/L, 104~20.9mg/L, 0.22~7.51mg/L, 12.7~548.7mg/L, 0.06~2.66mg/L, 0.12~3.39mg/L, 0.01~0.50mg/L. 0.02~0.42mg/L, 0.01~0.15mg/L and 1.29~11.51mg/L respectively. And the calculated annual average pollutant unit loadings of $BOD_5$ COD, SS, TKN, $NO_3-N$, $PO_4-P$, TP, HEM, Cr, Pb, Cu and Fe were 374.4kg/ha/yr 924.1kg/ha/yr, 983.6kg/ha/yr, 48.8kg/ha/yr, 8.1kg/ha/yr, 9.7kg/ha/yr, 17.8kg/ha/yr 943.0kg/ha/yr, 0.7kg/ha/yr, 0.9kg/ha/yr, 0.3kg/ha/yr and 28.9kg/ha/yr, respectively.

  • PDF

Spatial and Temporal Variations of Water Quality in an Urban Miho Stream and Some Influences of the Tributaries on the Water Quality (청주지역의 도심하천인 미호천에서 시공간적 수질변이 특성 및 유입지천의 영향)

  • Kim, Ji-Il;Choi, Ji-Woong;An, Kwang-Guk
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.433-445
    • /
    • 2014
  • The objective of study was to analyze seasonal and inter-annual patterns of water chemistry of Miho Stream watershed during 2004 - 2007 along with some influences of tributaries and summer monsoon on the stream water quality. For the study, eight physico-chemical parameters such as nitrogen, phosphorus, BOD, COD and chlorophyll-a (CHL) etc. were analyzed in relation to spatial and temporal variability of seven sampling sites of the mainstream and some tributaries in the watershed. In the upstream reach, Mean of BOD, COD and TP averaged 3.2 mg/L, 6.5 mg/L and $186{\mu}g/L$, respectively, indicating an eutrophic conditions as a III-rank in the stream water quality criteria from the Ministry of Environment, Korea(MEK). The eutrophic water was due to a combined effect of Chiljang tributary with high nutrients ($TP=844{\mu}g/L$, TN=8.087 mg/L) and the point sources from some wastewater treatment plants. In the meantime, BOD, TN, and TP in the downstream reach were about > 1.2-1.5 folds than the values of the midstream reaches. This was mainly attributed to effluents of nutrient rich-water (mean TN: 11.980 mg/L) from two tributaries of Musim Stream and Suknam Stream, which is directly influenced by nearby wastewater disposal plants. Seasonal analysis of water chemistry showed that summer monsoon rainfall was one of the important factors influencing the water quality, and water quality had a large spatial heterogeneity during the rainfall period. In the premonsoon, BOD in the downstream averaged $6.0{\pm}2.47mg/L$, which was 1.4-fold greater than the mean of upstream reach. Mean of CHL-a as an indicator of primary productivity in the water body, was > 2.2 - 2.9 fold in the downstream than in the upstream, and this was a result of the high phosphorus loading from the watershed. Overall, our data suggest that some nutrient controls in point-source tributary streams are required for efficient water quality management of Miho Stream.

Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Cherry Tree Plot - (강우시 비점오염원의 오염부하 특성 - 벚나무 재배지를 대상으로 -)

  • Kang, Mee-A;Choi, Byoung-Woo;Yu, Jae-Jeong
    • The Journal of Engineering Geology
    • /
    • v.20 no.4
    • /
    • pp.401-407
    • /
    • 2010
  • This study was carried out to produce the characteristics of pollutant loads caused by a cherry tree plot as a nonpoint sources(NPS) unit in agricultural areas. The relationship between rainfall and runoff didn't show a good coefficient with 0.5. Despite precipitation amount was less than 20 mm, runoff occurred with $0.5\;m^3$ because of high rainfall intensity of 8.8 mm/hr. In contrast, runoff was not occurred when precipitation amount was 47.4 mm in one case. In that case the primal effect on runoff was not precipitation amount. Correlation between load of pollutants such as BOD, COD, TN and TP and runoff' volumes showed significantly positive values which were more than r = 0.92 for all pollutants except SS(r = 0.71). SS could be a proper factor for estimating pollutant loads of BOD, COD, TN and TP because of a high correlation more than r = 0.73 between SS load and pollutant loads of BOD, COD, TN and TP. Both Organics and nutrient pollutants could be reduced if we control SS in runoff. The highest concentration of TN was detected in the event which was affected by fertilization activities directly. Therefore fertilization must be considered as a function of impact parameters on TN load in agricultural areas.