• Title/Summary/Keyword: loading BOD

Search Result 237, Processing Time 0.031 seconds

Estimating Unit Load of Non-Point Source Pollutants for Landuse Types in Anseongchun Watershed (안성천 유역의 토지이용별 비점오염원 원단위 산정)

  • Hwang, Byung-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1026-1033
    • /
    • 2009
  • In this study, we computed the unit load of nonpoint source for the forest, agricultural, and urban representative region in Anseongchun watershed. In addition, Flow-weighted mean concentration (FWMC) that well represents runoff characteristics of storm water during rainfall, was calculated, and runoff pollutants loading was also examined. FWMCs of 1st rainfall, which runoff coefficient was high, had a tendency higher than those of 2nd rainfall. Based on landuse results, pollutant concentration of the non-urban such as forest and agricultural regions was higher than that of urban region. In case of BOD, runoff pollutants loading was calculated as 1,395, 1,623, 2,268kg/d in 1st rainfall for forest, agricultural, and urban regions, respectively, while runoff loading of 2nd rainfall was 503kg/d in forest), 512kg/d in agricultural, and 898kg/d in urban. By landuses, unit load of the urban as 72.7kg/ha/yr was 12 times higher than that of the agricultural as 6.5kg/ha/yr, and 8 times higher than that of the forest as 9.5kg/ha/yr.

The Evaluation of Effect Indicators on Estimation of Aeration Volume for Wastewater Treatment Plants (하수처리장 송풍량 산정에 미치는 영향 인자들의 평가)

  • Kim, Byoung Soo;Choi, Mi Young;Kwon, Hyuck;Kim, Jin Man;Cha, Woon Ou;Chun, Wan Myung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.38-44
    • /
    • 2013
  • To construct the system controlling the aeration volume for D wastewater treatment plant effectively, the fluctuation of aeration volume was analyzed with changes of factors of the influent. As a result, the range of aeration volume was wide to maintain the certain concentration of DO, and the key factor to decide the aeration volume was found to be the temperature, F/M ratio, the loading rate of $BOD_5$ and T-N of the influent. Among the factors, the temperature of the influent had the most decisive effect on the aeration volume. The result showed that $45.8m^3/h$ of the aeration volume was needed with an increase of $1^{\circ}C$ of the influent, and the effect of the season was considered. Since the temperature of the influent is affected by a change of season, same as F/M ratio, the loading rate of the influent and the concentration of MLSS, it seemed that the change of the temperature of the influent affects the aeration volume even more. Therefore, it is preferable to consider the loading rate of the influent and F/M ratio altogether, rather than considering only one factor when deciding aeration volume.

Dischatge Loads of Nonpoint Source Pollutant in the Upper Watershed of Inigation Reservoir - Case Study of the Goseong Reservoir - (농업용 저수지 상류유역의 비점원오염 유출부하량 산정 - 고성저수지를 대상으로 -)

  • Kim, Jin-Ho;Han, Kuk-Heon;Ryu, Jong-Soo;Jung, Goo-Bok;Kwun, Soon-Kuk
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.324-331
    • /
    • 2007
  • This study was conducted to evaluate the influence of pollutant loads on the water quality in the Goseong reservoir from May 2005 to October 2006. Annual total runoff at the Goseong-cheon watershed was 968.0 mm in 2005, 382.6 mm in 2006, respectively. The mean concentration of BOD, COD and SS in the stream were 2.28, 6.03, 46.97 mg/L in rainy seasons and 0.95, 2.14, 6.05 mg/L in dry seasons at SWT C sub-watershed. Total-N concentrations ranged from 2.60 to 3.18 mg/L at SWT C sub-watershed, which was generally higher than the quality standard of agricultural water (1.0 mg/L). Total-P concentrations ranged from 0.044 to 0.130 mg/L at SWT C sub-watershed. Measured pollutant loads in the SWT C sub-watershed were 36.7 kg/day of BOD, 72.3 kg/day of T-N and 2.3 kg/day of T-P in 2005 at SWT C sub-watershed, 63.9 kg/day of BOD, 82.8 kg/day of T-N and 1.1 kg/day of T-P in 2006 at SWT C sub-watershed, respectively. In the analysis of the effluent characteristics for NPS pollutants, it appeared that the loading rates of effluent from SWT C watershed were, respectively, BOD 62.3%, T-N 69.6%, T-P 71.1%, SS 70.1% during the rainy season in 2006. The calculated T-N daily pollutant loadings by the unit loading factor method from each sub-watershed were much greater than observed, but the calculated T-P daily pollutant loadings much lesser than observed.

Evaluation of Wastewater Treatment Efficiency in Dongbokcheon Constructed Wetlands for Treating Non-point Source Pollution at Different Treatment Time and Wastewater Loading (비점오염원 처리를 위한 동복천 인공습지의 시기별 및 부하량별 수처리 효율 평가)

  • Lee, Sang-Gyu;Seo, Dong-Cheol;Kang, Se-Won;Choi, Ik-Won;Lim, Byung-Jin;Park, Jong-Hwan;Kim, Kap-Soon;Lee, Jun-Bae;Heo, Jong-Soo;Cho, Ju-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.929-936
    • /
    • 2011
  • To treat non-point source pollution in Dongbok lake, removal efficiencies of pollutants were investigated in Dongbokcheon constructed wetlands (CWs) at different treatment time and wastewater loading. The wetlands consisted of forebay, wetlands ($1^{st}$, $2^{nd}$, $3^{rd}$, $4^{th}$, $5^{th}$, $6^{th}$, $7^{th}$, and $8^{th}$ wetlands) and sedimentation pond. The concentrations of BOD, SS, T-N, and T-P in inflow ranged $0.85{\sim}3.14mg\;L^{-1}$, $3.33{\sim}9.70mg\;L^{-1}$, $0.64{\sim}5.33mg\;L^{-1}$, and $0.03{\sim}0.10mg\;L^{-1}$ from April to October in 2008, respectively. The removal rates of BOD, SS, T-N, and T-P in Dongbokcheon CWs were 34%, 5%, 31%, and 13%, respectively. The removal rates of BOD and T-N were higher than those for SS and T-P. The amounts of pollutant removal in Dongbokcheon CWs were higher in the order of forebay > wetlands > sedimentation pond for BOD, sedimentation pond > wetlands > forebay for SS, sedimentation pond > forebay > wetlands for T-N. The amount of T-P removal in wetlands was higher than forebay and sedimentation pond.

Spatial Analysis of Nonpoint Source Pollutant Loading from the Imha dam Watershed using L-THIA (L-THIA를 이용한 낙동강수계 임하댐유역 비점오염원의 공간적 분포해석)

  • Jeon, Ji-Hong;Cha, Daniel K.;Choi, Donghyuk;Kim, Tae-Dong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.1
    • /
    • pp.17-29
    • /
    • 2013
  • Long-Term Hydrologic Impact Assessment (L-THIA) model which is a distributed watershed model was applied to analyze the spatial distribution of surface runoff and nonpoint source pollutant loading from Imha watershed during 2001~2010. L-THIA CN Calibration Tool linked with SCE-UA was developed to calibrate surface runoff automatically. Calibration (2001~2005) and validation (2006~2010) of monthly surface runoff were represented as 'very good' model performance showing 0.91 for calibration and 0.89 for validation as Nash-Sutcliffe (NS) values. Average annual surface runoff from Imha watershed was 218.4 mm and Banbyun subwatershed was much more than other watersheds due to poor hydrologic condition. Average annual nonpoint source pollutant loading from Imha wateshed were 2,295 ton/year for $BOD_5$, 14,752 ton/year for SS, 358 ton/year for T-N, and 79 ton/year for T-P. Amount of pollutant loading and pollutant loading rates from Banbyun watershed were much higher than other watersheds. As results of analysis of loading rate from grid size ($30m{\times}30m$), most of high 10 % of loading rate were generated from upland. Therefore, major hot spot area to manage nonpoint source pollution in Imha watershed is the combination of upland and Banbyun subwatershed. L-THIA model is easy to use and prepare input file and useful tool to manage nonpoint source pollution at screening level.

Early Stage Performance of Constructed Wetland System for Nonpoint Source Pollution Control (비점원오염 제어를 위한 인공습지의 초기단계 연구)

  • Kim, Hyung-Chul;Ham, Jong-Hwa;Han, Jung-Yoon;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.4 s.118
    • /
    • pp.481-488
    • /
    • 2006
  • The field scale experiment was performed to examine the performance of the constructed wetland for nonpoint source (NPS) pollution loading reduction. Four sets (0.88 ha each) of wetland and pond system were used. After three growing seasons of the wetland construction, plant coverage increased to about 90% even without plantation from bare soil surfaces at the initial stage. During the start up period of constructed wetlands, lower water levels should be maintained to avoid flooding newly plants, if wetland plants are to start from germinating seeds. The average removal rate of $BOD_5$, TSS, T-N and T-P during the first two years was 5.6%, 46.6%, 45.7%, and 54.8%, respectively. The $BOD_5$ removal rate was low and it might be attributed to the low influent concentration. The early stage of wetland performance demonstrated the effectiveness of water quality improvement and was satisfactory for treating polluted stream waters. From the first-order analysis, T-P was virtually not temperature dependent, and $BOD_5$ and TSS were more temperature dependent than T-N. A pond-wetland system was more effective than a wetland-pond or a wetland alone system in water quality improvement, particularly to reduce T-P. Overall, the wetland system was found to be an adequate alternative for treating a polluted stream water with stable removal efficiency and recommended as a NPS control measures.

Study on the Performance of Constructed Wetland System for Sewage Treatment (인공습지 오수처리시설의 처리성능에 관한 연구)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.4
    • /
    • pp.96-105
    • /
    • 2000
  • Field experiment was performed from August 1996 to December 1999 to examine the performance of constructed wetland system for wastewater treatment in rural area. The constructed wetland system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand bed with planted reed. From August 1996 to June 1998 the hydraulic loading rate was fixed with about 15.63cm/day and theoretical detention time was 1.38 days, and from July 1998 to December 1999 the hydraulic loading rate was about 6.25cm/day and theoretical detention time was 3.5days. It worked continuously even during winter time, and the sewage flowed without freezing even when average daily air temperature was below -1$0^{\circ}C$. Average removal rate of BOD , COD, and SS was about 70%, T-P removal rate was about 50.8% , and T-N removal rate was 23.9%. The reason for poor T-N removal might be due to high influent concentration and short retention times. At the later years BOD and COD removal rates were increased , and SS and T-P removal rates did not change significantly , but T-N removal rates were decreased. The effluent of the wetland system often effluent water quality standards for sewage treatment plant, therefore, further treatment would be required if the effluent need to be discharged to the public water. Wetland system involves relatively large land area and could be suitable for rural area. Therefore, utilization of reclaimed sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage for agricultural purpose or subsequent land treatment is recommended as a ultimate disposal of sewage in rural area.

  • PDF

A Study on the Effect of Buddhist Dietary Life on the Degradation of Water Pollution (불교전통 식생활방식에 따른 수질오염 저감 효과 연구)

  • Choi, Kwang-Soo
    • Journal of Environmental Science International
    • /
    • v.24 no.2
    • /
    • pp.221-228
    • /
    • 2015
  • In this research traditional Buddhist dietary life style was studied as an alternative for both saving water and decreasing water pollution from household. A traditional dietary life style for the Buddhist monks, called Balwoo Gongyang, and its modernized one for citizens, called Dish Gongyang were examined with water use amount, wastewater quality and pollutant loading rate, and were compared with the kitchen wastewater from household. And several types of natural detergent were also examined to compare their effect on the wastewater quality and pollutant loading rate. This research was carried out using the wastewater from Balwoo and Dish Gongyang in J building located in Seoul. Wastewater generation from Balwoo Gongyang that was about $1.0{\ell}$/capita/day was very low compare to that from dish washing in normal household($32.6{\ell}$/capita/day). In case of Dish Gongyang, water generation was 1.8 times higher than that from Balwoo Gongyang, but it was just 1/19.2 of normal household. When the wastewater quality of Balwoo Gongyang was compared with the kitchen wastewater of normal household, SS was 1/16($15mg/{\ell}$), COD was 1/7($22.1mg/{\ell}$), BOD was 1/9($24.1mg/{\ell}$) and T-N was 1/16($1.7mg/{\ell}$). Pollutant loading rate from Balwoo Gongyang was very low, COD 18.0 mg/capita/day, SS 12.3 mg/capita/day and it was 1/290, 1/639 of that from dish washing wastewater from normal household, respectively. Pollutant loading rate from Dish Gongyang was also low 1/13(SS)~1/144(TN) compared to dish washing wastewater from normal household. As a natural detergent, used water from washing rice showed very low pollutant loading rate. It was concluded that Dish Gongyang that was a modernized and simplified dietary life style of Balwoo Gongyang, was very eco-friendly. Especially when it was combined with natural detergents using by-product from cooking process, its effect on the water pollution was very low.

Sewage Treatment using Aerated Submerged Biological Filter(ASBF) (호기성 침지형 생물막 여과장치를 이용한 오수처리)

  • Park, Jong-Woong;Song, Ju-seok
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.523-532
    • /
    • 2000
  • The purpose of this study was to investigate the effects of the hydraulic retention time (HRT) and organic loading rate (OLR) on microbial characteristics and treatment efficiency in sewage treatment using aerated submerged biological filter (ASBF) reactor. This reactor combines biodegradation of organic substrates by fixed biomass with a physical separation of biomass by filtration in a single reactor. Both simulated wastewater and domestic wastewater were used as feed solutions. The experimental conditions were a temperature of 17 to $27^{\circ}C$, a hydraulic retention time of 1 to 9hr, an organic loading rate of 0.47 to $3.84kg\;BOD/m^3{\cdot}day$ in ASBF reactor. This equipment could obtain a stable effluent quality in spite of high variation of influent loading rate. Total biomass concentration. biofilm thickness and biofilm mass increased an exponential function according to the increasing OLR. The relationships between water content and biofilm density were in inverse proportion. The percentage of backwash water to influent flow was almost 9%. The separation efficiency of biomass was the percentage of 91 to 92 in ASBF reactor. The sludge production rates in feed solutions of simulated wastewater and domestic wastewater were 0.14~0.26 kg VSS/kg BODrem, 0.43~0.48 kg VSS/kg BODrem, respectively.

  • PDF

Characterization of Combined Sewer Overflows from a Small Urban Watershed and Determination of Optimum Detention Volume (소규모 도시유역 합류식 하수관거 월류수 특성화 및 최적 저류지 용량 결정)

  • Jo, Deokjun;Kim, Geonha
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.314-320
    • /
    • 2006
  • Diffuse pollution from an urban area contributes to the significant pollution loading to a receiving water body. In this paper, rainfall runoffs from an urban basin with combined sewer systems located in the city of Daejeon were monitored to measure the rainfall runoff discharge rates and pollutant concentrations. Strong first flush effects were observed for all monitored rainfall runoffs. The first flush effects were closely related to rainfall intensity, while suspended solids were closely related to pollutant constituents. The observed averaged Event Mean Concentrations (EMCs) of Combined Sewer Overflows (CSOs) were 536.1 mg SS/L, 467.7 mg CODcr/L, 142.7 mg BOD/L, 16.5 mg TN/L, and 13.5 mg TP/L. Storage volumes for containing the first flush to improve water quality of the receiving stream can be estimated based on suspended solid concentration. In this study, retainment of the first flush equivalent to 5mm of precipitation could reduce diffuse pollution loading induced by CSOs to a receiving water body by up to 80% of suspended solid loading.