• 제목/요약/키워드: loading BOD

검색결과 237건 처리시간 0.028초

PAC-A/O 공정을 이용한 안료폐수의 질소 제거 특성 (Nitrogen removal characteristics of pigment wastewater using PAC-A/O process)

  • 정종식
    • 상하수도학회지
    • /
    • 제32권1호
    • /
    • pp.19-25
    • /
    • 2018
  • The objectives of this study were to evaluate the removal characteristics of total nitrogen, the influence factor of denitrification and the optimum operating condition in the pigment wastewater treatment using PAC-A/O process. The operating conditions of PAC-A/O process were mean BOD volumetric loading $0.86kgBOD/m^3/day$, mean F/M ratio 0.072~0.13 kgBOD/kgMLVSS/day and mean C/N ratio 3.47, respectively. The conditions of anoxic process in the field plant test were mean pH 8.3~8.7 and mean temperature $34.1{\sim}44.0^{\circ}C$. The ORP bending point knee was eventually appeared in the ORP -107 mV and $NO_3{^-}-N$ removal efficiency was increased according to the ORP decrease. In the ORP -107 mV below condition, the removal efficiency of T-N and $NO_3{^-}-N$ was 92.3~95.0% and 98.5~99.7%. Denitrification rate was calculated to be 1.581~1.791 mg $NO_3{^-}-N/gMLSS/hr$. The experimental results showed that the ORP control in the PAC-A/O process could be an effective method for treatment of pigment wastewater.

토양미생물을 이용한 축산폐수 처리의 공정별 제거효율 및 동력학적 상수 (Swine wastewater treatment with soil microbes and its efficiency and dynamic parameters)

  • 박완철;신남철
    • 한국환경농학회지
    • /
    • 제19권2호
    • /
    • pp.177-182
    • /
    • 2000
  • 토양 미생물을 이용한 고농도 축산폐수의 과부하 처리를 위한 공정개발 연구결과 유기물 제거율은 99%이었다. 상온 혐기조에서 $0.7kg\;BOD/m^3/d$ 이하에서 처리수의 BOD 농도는 150mg/L 이하를 이었다. 상온 혐기조를 운전한 실험에서 후속 폭기조의 물질 대사계수(km)는 $0.73hr^{-1}$, 세포증식계수(Y)는 0.433 g/VSS/g BODrm/d 였으며 중온으로 운전한 경우 후속 폭기조에서 각각 $1.45hr^{-1}$과 0.776 g VSS/g BODrm/d 로 반응계수 값이 두 배에 가깝게 개선되었다.

  • PDF

합류식 하수관거 월류수 저장 시설에 대한 효과 - 강우시 합류식 하수관거에서의 오염물질 유출특성 분석 (Effect for CSOs Storage Construction - Analysis of Storm Water Run-off Characteristics in combined sewer system)

  • 박진규;이남훈;김해룡;이웅;이채영
    • 상하수도학회지
    • /
    • 제25권6호
    • /
    • pp.949-957
    • /
    • 2011
  • This aim of study was to investigate the characteristics of discharge of pollutants as well as the correlation between flow rate and water quality constituents in a combined sewer system according to the characteristics of rainfall. For the loading rates for each pollutant, the median concentrations of all pollutants except T-N was increased when a CSO took place. The loading rates of BOD, COD, SS, T-N, T-P, Cu and Zn at the CSOs were 328-1255, 25-129, 83-2009, 4-12, 14-51, 5-11 and 5-13 times higher than the DWF (Dry Whether Flow), respectively. Especially, SS loading rate was found to be highest in all pollutants. On the other hand, the range of the first flush coefficient, b for water quality constituents such as BOD, COD, SS, T-N, T-P, Cu and Zn were 0.537-0.878, 0.589-0.888, 0.516-1.062, 0.852-1.031, 0.649-0.954, 0.975-1.015 and 0.900-1.114, respectively. In term of correlation between flow rate and pollutant concentrations, SS concentration was highly correlated to flow rate. However, there was an inverse correlation between EC (Electrical Conductivity) and flow rate because of the high dilution of flow rate. In case of correlation between pollutants, there was a high correlation between SS and T-P.

광합성세균에 의한 미생물막의 형성

  • 오광근;이철우;전영중;이재홍
    • 한국미생물·생명공학회지
    • /
    • 제24권6호
    • /
    • pp.733-737
    • /
    • 1996
  • The formation of microbial films(biofilm) by a non-sulfur phototrophic bacteria, Rhodopseudomonas capsulata, on inorganic media was studied. Porous ceramic beads(PCB) were superior to other immobilizing media for the biofilm formation in a packed-bed reactor. It was found that the formation of microbial films favored a lower hydraulic retention time, showing a higher ratio of cells attatched to the media to those suspended in the solution. The cell concentration in the biofilm reactor was as high as 11,400mg/l, which is 8-folds of the cell concentration in an ordinary suspended treatment. It was observed that the formation of micribial film by R. capsulata followed a general serial process of cell attachment, microcolony formation, and biofilm formation. The microbial films thus formed was very stable even for an extremely high volumetric BOD loading rate of 15gBOD/l day. The scanning electron micrographs of the microbial films showed that the cells were attached to both the surface and pores of the media.

  • PDF

생물학적 질소.인 제거를 위한 SMMIAR(Submerged Moving Media Intermittent Aeration Reactor) 공정의 운전 특성 (The Operating Characteristics of SMMIAR process for Biological Nitrogen.phosphorus Removal)

  • 김홍태;김학석;김규창
    • 한국환경과학회지
    • /
    • 제12권1호
    • /
    • pp.55-61
    • /
    • 2003
  • This study was carried out to obtain the operating characteristics of SMMIAR process for biological nitrogenㆍphosphorus removal. SMMIAR was operated at HLR(Hydraulic loading rate) of 39.6, 52.8, 63.4 and 79.2 $\ell$/$m^2$/d respectively and the operating parameters such as intermittent aeration time ratio of aerobic/anoxic, DO and microorganism concentration were changed to confirm the optimum operating condition. The concentrations of the wastewater BOD, TN(Total nitrogen) and TP(Total phosphorus) were 150, 30 and 7.5mg/$\ell$ respectively. Achieving better removal efficiencies of BOD, TN and TP up to 90, 85.4 and 95.4% respectively, we must keep in operation condition of SMMIAR by 0.75 of time ratio of aerobic/anoxic and by minimum 45 minutes of oxic period simultaneously.

간접 포기식 유동상의 이상적 설계에 관한 연구 (A Study on the Optimal Design in the Indirect Aerated Fluidized Bed)

  • 안송엽;김환홍;권희태
    • 한국환경과학회지
    • /
    • 제8권1호
    • /
    • pp.95-100
    • /
    • 1999
  • Process intensification without any increase in bed requires the exploitation of fluid mechanical phenomena as the basis for elegant solutions to the process engineering problems which result from the need to retain and control the immobilized biomass, and for biomass recovery. The fluidized bed biological reactor provides a solution to these needs. The wastewater treatment characteristics of the fluidized bed was filled with sand media. Indirect aeration were studied experimentally. The researcher was filled with sand particle size(0.60~0.42mm) in three reactors with different section area(A)/height(H), in the state BOD loading 4.5kg-$BOD_5/m^3$ㆍd, and under the fixed state of hydraulic retention time for around 32 minutes.

  • PDF

삽교호 유입하천에서 강우시 주요 오염물질의 유출 특성 (Runoff Characteristics of Major Pollutants at the Inflow Stream to Lake Sap-Kyo in Rainy Periods)

  • 박재영;김영철;오종민
    • 생태와환경
    • /
    • 제34권1호통권93호
    • /
    • pp.62-69
    • /
    • 2001
  • 본 연구는 삽교호 유입지천(곡교천, 무한천, 삽교천, 남원천)에서 강우시 유량 및 수질 관측을 1999년 6월부터 11월까지 실시하여 분석한 것이다. 연구의 최종 목적은 삽교호 수질을 개선시키는 것이며, 그 일환으로 삽교호 유입지천의 오염부하를 저감시키기 위해 강우시 유입되는 비점오염물질의 유출 특성 및 오염부하량을 산정하는데 본 연구의 목적이 있다. 조사 결과, 평상시 삽교호 수량에 가장 많은 영향을 미치는 유입지천은 삽교천이며, 강우시에는 유역면적이 가장 넓은 곡교천이 삽교호 수량에 가장 큰 영향을 미쳤다. 유역의 토지이용형태에 따른 유출 특성에 현격한 차이를 보여 수질 관리를 위한 대책 수립시 고려되어야 할 인자로 도출되었다. 삽교호로 유입되는 연간 총오염부하량 중 강우시 발생되는 비점오염부하량의 기여율은 SS, BOD, T-N 및 T-P 각각 62%, 43%, 41% 및 27%으로 추정되어 삽교호 수질을 개선하는데 유입부하를 감소시키기 위한 관리기법을 도입할 때 점오염원과 비점오염원에 대한 부하량 저감대책을 함께 수립해야 할 것으로 판단된다.

  • PDF

대전 갑천의 수질변화 경향 및 주요 수질 영향 인자 분석 (Analysis on Trends and Major Impact Factors of Water Quality Dynamics in the Gab-Cheon River, Daejeon, Korea)

  • 이가영;서동일
    • 대한환경공학회지
    • /
    • 제37권9호
    • /
    • pp.517-525
    • /
    • 2015
  • 대전 3대 하천의 1992년 1월부터 2014년 12월까지 수질변화 추이를 분석하고, 대전하수처리장의 방류수가 갑천의 수질환경에 미치는 영향을 분석하였다. 2014년 대전의 갑천3 지점의 BOD, COD, TN, TP 연평균 농도는 각각 1.53, 3.36, 2.16, 0.03 mg/L로서 우리나라 하천수질기준으로 Ib 급수의 수준을 나타내나, 하수처리장 방류수가 유입된 이후 금강으로 유입되기 직전 지점인 갑천A 지점에서는 각각 3.43, 11.51, 8.62, 0.12 mg/L 수준으로써 COD는 매우 나쁜 수준인 VI 급수의 수준에해당하며 BOD와 TP는 III 급수의 수준을 나타낸다. 대전하수처리장이 가동을 시작한 1994년 이전의 수질에 비하여 고도처리 시설이 완공된 2013년 이후의 수질을 비교하였을 경우, 전체적으로 수질이 개선되었으나, 갑천 최상류 봉곡교 지점 및 최하류 지점의 TN농도는 각각 2배 및 3배가량 증가한 것으로 조사되었다. 갑천 최하류의 수질에 기여하는 오염부하량 분포를 산정한 결과 대전의 하수처리장 방류수가 TN, TP, BOD와 COD 총부하량의 각각 76%, 63%, 35% 및 46%를 차자하는 것으로 나타났다. 따라서 금강의 수질을 개선하기 위한 갑천의 수질관리는 TN 및 TP 등 영양염류는 하수처리장의 방류수를 추가 개선하는 것이 바람직한 것으로 판단되며, BOD 및 COD를 포함하는 유기물은 하수처리장 방류수의 오염부하와 함께 위 부하량의 각각 54% 및 47%를 차지하는 각종 소하천 및 우수거등 비점오염원에서 유입되는 부하량을 함께 관리해야 할 필요성이 있다고 분석된다.

남강댐 하류의 오염원별 기여율 분석을 위한 유역-하천 연계 모델 적용 방안 연구 (A Study on Application of Watershed-River Hybrid Model for Contribution Analysis of Pollutant Loading at Namgang Dam Downstream)

  • 황진영;김영도;권재현;이용곤
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2016년도 학술발표회
    • /
    • pp.125-125
    • /
    • 2016
  • 남강 권역은 5개의 단위유역으로 구성되어 있으며, 남강A, 남강B, 남강C, 남강D와 남강E로 명명되고 1단계 수질오염총량관리제도 시행 이후 유역 내 개발 등으로 인한 오염원이 증가하고 장기간 퇴적된 저니층으로부터 오염물질이 용출되는 등 수질의 자정능력보다 더 많은 오염물질이 수체내로 유입됨으로써 수질이 악화되자 수량확보 뿐만 아니라 남강의 수질관리에 대해서 관심을 가지기 시작하였다(GNDI, 2010). 남강 하류수계는 하상구배가 매우 완만하며 유속이 느리다. 따라서 물의 체류시간이 호수와 비슷한 양상을 보이고 있다. 더욱이 남강 하류수계는 주변의 도시와 농경지로부터 물의 소모량이 크기 때문에 하류수계의 물의 흐름이 더욱 완만해지고 이로 인하여 수질 악화가 가속화되고 수역의 영양단계가 점점 증가하는 부영양화현상이 발생되고 있다. 남강하류수계와 같이 부영양화 된 수계내의 미처리 된 영양염을 이용한 식물플랑크톤의 생산에 의해 자생BOD가 공급된다. 따라서 남강댐 하류지역과 같은 수리 수문학적 특징을 가진 유역은 수질관리를 위해서 특정 수역에 유입 BOD와 자생 BOD가 어느 정도 기여하는가를 정량적으로 파악한 후, 기여도에 따라 오염원인 물질을 줄이기 위한 수질관리 방안이 설정되어야 한다. 본 연구에서는 남강유역의 오염원의 기여율 분석을 위해 하천수질모델인 QUALKO2를 사용하였으며, 점오염원 뿐만 아니라 수질에 상당한 영향을 끼치는 비점오염원의 영향을 통합적으로 고려하기 위하여 유역 모델인 SWAT과의 연계방안을 제시하였다. 또한 모델의 연계 적용을 통해 산정된 내부오염원과 내부오염원의 기여율과 수질측정결과를 활용하여 분석한 기여도와의 비교를 수행하여 신뢰성을 확보하였다.

  • PDF

생물학적 유동층을 이용한 어류양식 순환수의 처리씨스템 개발 (Developments of Water Treatment System by Biological Fluidized Bed for Water Reuse Aquaculture)

  • 이기완
    • 한국수산과학회지
    • /
    • 제26권4호
    • /
    • pp.380-391
    • /
    • 1993
  • 고밀도의 어류양식 순환수 처리씨스템 개발을 위하여 양식장의 수질특성 조사 및 생물학적 유동층 공정에 의한 모형 폐수처리 장치로 운영 실험한 결과를 요약하면 다음과 같다. 1) 단일어종을 양식하는 H 및 S 양만장 폐수의 경우 BOD $9.4{\sim}13.1\;mg/l$, COD(Mn) $14.5{\sim}20.0\;mg/l,\;NH_4-N\;1.1{\sim}2.3\;mg/l,\;NO_3-N\;15{\sim}21\;mg/l$이었고, 틸라피아 등 3종의 어류를 사육하는 B 및 K 양식장에서는 BOD $9.3{\sim}11.3\;mg/l$, COD(Mn) $8.0{\sim}11.1\;mg/l,\;NH_4-N\;7.3{\sim}20.2\;mg/l,\;NO_3-N\;26.9{\sim}46.4\;mg/l$의 수질특성을 나타내었다. 2) H 및 S 양만장 폐수의 BOD/COD 비율은 0.65로 거의 동질의 유기물 농도 값을 가지며, 틸라피아 등 3 종의 어류를 사육한 B 및 K 양식장 폐수에서는 크게 상이하였다. 3) 양식장의 여과조 및 동육조내 DO 농도를 기준으로 한 시간별 수질변동폭은 $1.5{\sim}2.0$ 배로 조사되었다. 4) 양만장 폐수의 탄소성 유기물 분해속도상수값은 $0.049\;d^{-1}$, 질산화반응 속도상수값은 $0.035\;d^{-1}$로서 미생물 분해작용에 의한 BOD 곡선식은 다음과 같이 나타낼 수 있었다. $y_T=14.1(1-10^{-0.222t)+30.9(1-10^{-0.035(t-8)})$ 5) BFB 처리 씨스템의 $0.014{\sim}0.075g\;NH_4-N/g\;BVS{\cdot}day$ 부하 조건 하에서 5 배의 암모니아성 질소 부하량 증가에도 질산화율은 $65{\sim}79\%$로 안정되게 나타났다. 6) BFB 처리 씨스템에 있어서 $0.014g\;NH_4-N/g\;BVS{\cdot}day$의 낮은 암모니아성 질소 부하조건에서는 공존 유기물 농도가 실산화 반응속도 저하 요인으로 작용하였다. 7) 부하율 변화 영향을 받지 않을 것으로 예측되었던 미생물 농도 $3.04{\sim}3.44\;g/l$의 무산소 BFB 탈질 씨스템에서 T-N 부하율 증가시 T-N 제거율 감소경향이 뚜렷하였던 바, 그 이유는 화기성조내에서 호기성 질산화 미생물의 증식이 억제되었기 때문으로 파악되었다. 8) 부하율 변화에 따른 처리율의 안정성과 반응조내에서 고농도의 미생물유지 잠재력을 확보하는 BFB 방법은 소요 부지면적이 작고 처리효율을 임의로 선택할 수 있는 실용성이 보장되므로 기존의 처리방법보다 설계 및 운영면에서 유리할 것으로 평가되었다.

  • PDF