• Title/Summary/Keyword: loading BOD

Search Result 237, Processing Time 0.02 seconds

A Study on the Characteristics of the Soysauce Wastewater Treatment in Aerobic Submerged Biofilter (간접포기식 침지여상의 장류 폐수처리특성에 관한 연구)

  • 권영호;원찬희;신승원
    • Journal of Environmental Science International
    • /
    • v.7 no.5
    • /
    • pp.679-685
    • /
    • 1998
  • The Soysauce wastewater removal characteristics of submerged biofilters filled with two filter media respectively were experimentally examined with constant temperature, pH value and variable BOD loading and recirculation ratio. The decreasing order of BOD removal is Netring(random plastic media), cubic wire meshes(plastic module). This is mainly due to the media characteristics such as void ratio, specific surface area and media shapes. The BOD removal ratio decreases with increasing $BOD_5$/ volumetric loading rate, and the loading rate for the BOD removal over 85% is lower than 1.5kg$BOD_5$ 5/$m^3$d for the plastic media of Netring and cubic wire meshes. The $BOD_5$ removal rate increases with the recirculation ratio, but the rate of increase become smaller as the recirculation ratio increases over 20. When $BOD_5$ volumetric loading is 1.5kg$BOD_5$/$m^3$d, the required recirculation ratio to obtain 85% BOD$_{5}$ removal is about 20 for Netring and it was about 30 for cubic wire meshes.s.

  • PDF

A Study on the Wastewater Treatment Characteristics according to Operating Condition of the Indirectly Aerated Fluidized Bed (간접(間接) 포기식 유동상(流動床)의 운전조건(運轉條件) 변화에 따른 처리(處理) 특성(特性)에 관한 연구 -오니전환율 및 산소이용속도를 중심으로-)

  • Lee, Jeoung-Su
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.3
    • /
    • pp.79-86
    • /
    • 1997
  • The characteristics of wastewater treatment according to operating condition of indirectly aerated fluidized bed filled with sand media were studied experimentally, and the obtained results were as follows; 1. During be operated under the BOD loading rate, $4.5kg-BOD/m^3{\cdot}day$, effluent SS according to the increase of recirulation velocities was gradually decreased. 2. According to the increase of media concentration, sludge convertion rate was gradually increased. 3. Under the same BOD loading rate, according to the increase of recirulation velocities, F/M ratio was gradually increased, however, sludge convertion rate was greatly decreased. On the other hand, inffluent BOD concentration has not an important effect. 4. Under the constant recirulation velocities, according to the increase of BOD loading rate, sludge convertion rate was gradually increased. 5. Under the same BOD loading rate, according to the increase of recirulation velocities, oxygen consumpion rate of microorgnism was gradually increased.

  • PDF

광합성세균 미생물막반응기에 의한 유기성폐수의 처리특성

  • Oh, Kwang-Keun;Lee, Cheol-Woo;Jeon, Yeong-Joong;Lee, Jae-Heung
    • Microbiology and Biotechnology Letters
    • /
    • v.24 no.6
    • /
    • pp.738-742
    • /
    • 1996
  • An efficient packed-bed type biofilm reactor charged with immobilized phototrophs was developed to treat organic wastewater at an extremely high volumetric loading rate. The packed bed reactor (PBR) charged with porous ceramic beads was superior to a fluidized-bed reactor suspended with activated carbon powders in terms of many aspects such as BOD removal efficiency, operational stability, and overall economics. For wastewater with BOD concentration as high as 20, 000mg/l, the BOD removal efficiency was maintained above 90% when the hydraulic retention time (HRT) was longer than 1 day. The allowable volumetric BOD loading rate of this reactor (20gBOD/l day) is more than ten-folds higher than that of an ordinary activated sludge method. The behaviour of the reactor was represented well by a Monod type kinetic equation with a maximum specific BOD loading rate(P) of 22.2gBOD/l day and a half saturation constant(K$_{s}$) of 1, 750 mgBOD/l.

  • PDF

Yeast Loading BOD Biosensor (효모균을 이용한 BOD Biosensor)

  • Kim, Mal-Nam
    • The Korean Journal of Mycology
    • /
    • v.23 no.4 s.75
    • /
    • pp.354-358
    • /
    • 1995
  • A yeast loading biochemical oxygen demand (BOD) sensor was designed and constructed to quickly measure the concentration of biologically assimilable organic substances dissolved in water as BOD values to feed back to the waste water treating processes. The sensitivity of the BOD sensor reached maximum at around pH 7.0 and $30^{\circ}C$ where yeast showed the highest assimilation activity. Biomass also affected the sensor output, and biomass of $ 0.14\;mg/cm^2$ on the dialysis membrane appeared to be the optimum cell mass level. The sensitivity of the sensor depended on the kinds of pollutants and increased considerably when the yeast was preincubated in the solution of respective pollutants before loading on the sensor.

  • PDF

The Effect of Discharge Loading at Sewage Treatment Plants on Water Quality in Kyoungan Stream (경안천 수질에 대한 환경기초시설 방류부하량의 영향)

  • Kim, Ho-Sub;Lee, Su-Woong;Rhew, Doug-Hee;Kong, Dong-Soo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.452-458
    • /
    • 2009
  • This study was carried out to assess the effect of discharge loading at sewage treatment plants (STP) on water quality in Kyoungan stream. The seasonal variations of water quality (BOD, COD, SS, TN, and chl.a) at site 1(Mesanribo) were similar with those at site 2(Sehabo). BOD, COD, SS, and chl.a concentration were also similar except for TN and TP concentration which were lower than those at site 1. The BOD, COD, TN, TP and chl.a concentration at site 2 in dry period were higher than that of wet period. The ratios of BOD, TP, COD, SS discharge loading at all STP in Kyoungan stream watershed to delivery loading at site 2 were 0.69, 0.54, 0.48, 0.31, and 0.26 on average, respectively. Both site 1 and site 2, the seasonal variations of discharge loading at STP did not showed any relationship with those of water quality. The mean ratios of inflow loading at site 1 to delivery loading at site 2 were relatively high that ranged from 0.43 to 0.61. In dry period, the ratios of discharge loading at STP in Sehabo watershed to delivery loading at site 2 were below 0.2 except for BOD (0.24), and decreased <0.1 in wet period. While, SS loading from watershed between site 1 and site 2 to delivery loading at site 2 ratios increased in wet period.

Water Quality Analysis in Nakdong River Tributaries Using 2012-2016 Monitoring Data (2012-2016년 모니터링 자료를 이용한 낙동강 지류·지천 수질 특성 분석)

  • Son, Younggyu;Na, Seungmin;Im, Tae Hyo;Kim, Sang-hun
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.680-688
    • /
    • 2017
  • Water quality monitoring for flow rates and BOD/COD/T-N/T-P/SS/TOC concentrations has been conducted in Nakdong river tributaries since 2011. In this study concentrations and loading rates of BOD, T-P, and TOC were analyzed to evaluate water quality monitoring stations using accumulated data at 206 tributary monitoring stations in Nakdong river 2012 ~ 2016. Average concentration ranges for 206 monitoring stations were 0.3 ~ 6.4 mg/L, 0.025 ~ 1.562 mg/L, and 0.6 ~ 10.7 mg/L for BOD, T-P, and TOC, respectively. Additionally, average loading rate ranges were 0.96 ~ 46,040 kg/d, 0.087 ~ 1,834 kg/d, and 1.51 ~ 80,425 kg/d for BOD, T-P, and TOC, respectively. Average concentration for BOD, T-P, and TOC at each monitoring station was evaluated using ambient water quality standards of rivers and water quality regulation level for medium-sized management areas. Average loading rate and specific loading rate (loading rate/drainage basin area) for BOD, T-P, and TOC at each monitoring station was considered to evaluate monitoring stations using suggested classification (BOD, TOC: -1, 1 ~ 10, 10 ~ 100, 100 ~ 1,000, and 1,000 ~ kg/d; T-P: -0.1. 0.1 ~ 1, 1 ~ 10, 10 ~ 100, and 100 ~ kg/d) Using results of this study, various water quality status maps were provided, and three evaluation methods were suggested to determine priority monitoring stations in Nakdong river for rational water quality control and tributaries basin management.

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

A Study on the BOD Removal Characteristics of Aerobic Submerged Biofilter (Media를 충전(充塡)한 간접폭기식(間接曝氣式) 침지여상(浸漬濾床)에 의한 BOD제거 특성에 관한 연구)

  • Yang, Sang Hyun;Kwon, Young Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.669-678
    • /
    • 1994
  • The BOD removal characteristics of submerged biofilters filled with three kinds of filter media respectively were experimentally examined with constant temperature, pH value and variable BOD loading and recirculation ratio. Obtained results are as follows; 1. The BOD removal ratio decreases with the increasing $BOD_5$ volumetric loading rate, and the loading rate for the BOD removal over 90% is lower thean $1.6kg{\cdot}BOD_5/m^3{\cdot}d$ for the plastic media of Netring and cubic wire meshes. This is a much large value than $0.3{\sim}0.8kg{\cdot}BOD_5/m^3{\cdot}d$ for conventional activated sludge process. The required submerged biofilter volume is found to be much samller than that of conventional activated sludge process. 2. The decreasing order of BOD removal is Netring (random plastic media), cubic wire meshes (plastic module), and then gravel (stone media). This is mainly due to the media characteristics such as void ratio, specific surface area and media shapes. 3. The $BOD_5$ removal rate increases with the recircuration ration, but the rate of increases becomes samaller as the recirculation ratio increases over 20. When $BOD_5$ loading is $1.8kg{\cdot}BOD_5/m^3{\cdot}d$, the required recirculation rationto obtain 90% $BOD_5$ removal is about 20 for Netring and it was about 30 for cubic wire meshes. 4. Reynold's Number increases with recirculation ratio, and the Reynold's Numbers corresponding to the recircuration ratio of 10~50 are less than 52, showing laminar up flows in the filter. The settled and effluent sludges increase with increase of Reynol's Number, and there are the definite Reynold's Numbers at which the settling sludge concentrations become nearly constant respectively in each filters. 5. In this submerged biofilter system, small volume of sludge hopper can be substituted for a separated settling tank.

  • PDF

A Study on the Treatment Efficiency of Sequencing Batch Reactor with the Livestock Nightsoil Organic Loading Rate Variance (가축분뇨 유기물질부가별 연속회분식반응조 효율에 관한 연구)

  • 여운호
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.32-36
    • /
    • 1995
  • This study was carried out to investigate the treatment efficiency of sequencing batch reactor when the livestock nightsoil organic loading rate was varied. Sequencing batch reactor was operated with the variance of influent BOD concentration and operating cycle. The average influent BOD concentrations in this study were 150 mg/l, 200 mg/l, 250 mg/l, 300 mg/l, 350 mg/l, 400 mg/l, 450 mg/l and 500 mg/l in the condition of 1~3 cycles/day. The treatment efficiency of sequencing batch reactor is good at the volumetric loading of 0.05~0.20 kg $BOD/m^3\cdot day$. Therefore, sequencing batch reactor process would become an effective alternative for the process of small scale livestock nightsoil treatment plants.

  • PDF

The Study on Decline Plan of Primary Production Organic Matter of Uiam Lake Basin (의암호 유역에서 발생하는 자체생산 유기물 저감방안에 관한 연구)

  • 허인량;이건호;함광준;최지용;정의호
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.1
    • /
    • pp.50-58
    • /
    • 2004
  • The present study was designed to evaluate primary production organic matter in basin of lake around by execution of total maximum daily loading. BOD influent loading of Uiam lake was 2,819 kg/day, which was less then 28.3 percent, total effuluent loading as 3,619 kg/day, in comparision with BOD, total nitrogen influent loading was 4,681 kg/day, which was less then 10.0 percent, total effuluent loading as 5,150 kg/day. But in case of total phosphors influent loading was 73.3 kg/day, which was more then 34.2 percent, total run off loading as 48.3 kg/day. The result of survey reduction plan of primary production organic matter in basin of lake around which objectives of abstract is as follows. First plan was reduction of primary production organic matter by moving the outlet of municipal wastewater treatment center from present place to lake downstream. Secondary plan was improvement by diffusion type of outlet municipal wastewater treatment center. The third plan was reduction of environmental impact by passing and storing of municipal wastewater. Finally plan was decline water surface level which was present hydrouric retention time was reduction from 7.6 day to 6.0 day per meter.