• 제목/요약/키워드: load-slip curve

검색결과 39건 처리시간 0.023초

Experimental and numerical study of large high strength bolt shear connector embedded in HFRC

  • Yuliang He;Zhengxin Wang;Weiming Wu;Ying Yang;Yiqiang Xiang
    • Steel and Composite Structures
    • /
    • 제49권2호
    • /
    • pp.197-213
    • /
    • 2023
  • To investigate the static properties of large high strength bolt shear connector in hybrid fiber-reinforced concrete (HFRC) and normal concrete (NC), eight push-out test specimens with single/double nut and HFRC/NC slabs were designed and push-out tests were conducted. A fine 3D nonlinear finite element (FE) model including HFRC constitutive model was established by using ANSYS 18.0, and the test results were used to verify FE models of the push-out test specimens. Then a total of 13 FE models were analyzed with various parameters including fiber volume fractions of HFRC, bolt diameter and thickness of steel flange. Finally, the empirical equations considering the contribution of polypropylene fiber (PF) and steel fiber (SF) obtained from the regression of the test results and FE analysis were recommended to evaluate the load-slip curve and ultimate capacity of the large high strength bolt shear connector embedded in HFRC/NC.

Experimental studies on steel frame structures of traditional-style buildings

  • Xue, Jianyang;Qi, Liangjie
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.235-255
    • /
    • 2016
  • This paper experimentally investigated the behavior of steel frame structures of traditional-style buildings subjected to combined constant axial load and reversed lateral cyclic loading conditions. The low cyclic reversed loading test was carried out on a 1/2 model of a traditional-style steel frame. The failure process and failure mode of the structure were observed. The mechanical behaviors of the steel frame, including hysteretic behaviors, order of plastic hinges, load-displacement curve, characteristic loads and corresponding displacements, ductility, energy dissipation capacity, and stiffness degradation were analyzed. Test results showed that the Dou-Gong component (a special construct in traditional-style buildings) in steel frame structures acted as the first seismic line under the action of horizontal loads, the plastic hinges at the beam end developed sufficiently and satisfied the Chinese Seismic Design Principle of "strong columns-weak beams, strong joints-weak members". The pinching phenomenon of hysteretic loops occurred and it changed into Z-shape, indicating shear-slip property. The stiffness degradation of the structure was significant at the early stage of the loading. When failure, the ultimate elastic-plastic interlayer displacement angle was 1/20, which indicated high collapse resistance capacity of the steel frame. Furthermore, the finite element analysis was conducted to simulate the behavior of traditional-style frame structure. Test results agreed well with the results of the finite element analysis.

ATB 프로그램에서 삼점식 좌석 벨트 모델의 구현 (Implementation of 3-point Seat Belt Model into ATB Program)

  • 전규남;손권;최경현
    • 한국자동차공학회논문집
    • /
    • 제11권3호
    • /
    • pp.145-154
    • /
    • 2003
  • Occupant simulation models have been used to study trends or specific design changes in several typical crash situations. The ATB, Articulated Total Body, was developed and used to predict gross human body responses to vehicle crashes and pilot ejections. Since the ATB source code is open to public, the user can add their own defined modules and functions. The introduction of seat belts into cars significantly decreased the injury risk of passengers in frontal impacts. In this paper, a new seat belt model was developed and implemented into the ATB. For this purpose, a subroutine of the new seat belt was constructed. A force-deflection function was added to replace an existing function to consider energy absorption. The function includes hysteresis effects of the experiment data of the loading and unloading parts of the seat belt load-extension curve. Moreover, this belt model considers a slip between ellipsoid and belt segments. This paper attempted to validate the ATB program which includes the subroutine of new belt models comparing with the real car frontal crash experiments and MADYMO frontal models. The analysis focusses on the human movement and body accelerations.

Corrosion effects on tension stiffening behavior of reinforced concrete

  • Shayanfar, M.A.;Ghalehnovi, M.;Safiey, A.
    • Computers and Concrete
    • /
    • 제4권5호
    • /
    • pp.403-424
    • /
    • 2007
  • The investigation of corrosion effects on the tensile behavior of reinforced concrete (RC) members is very important in region prone to high corrosion conditions. In this article, an experimental study concerning corrosion effects on tensile behavior of RC members is presented. For this purpose, a comprehensive experimental program including 58 cylindrical reinforced concrete specimens under various levels of corrosion is conducted. Some of the specimens (44) are located in large tub containing water and salt (5% salt solution); an electrical supplier has been utilized for the accelerated corrosion program. Afterwards, the tensile behavior of the specimens was studied by means of the direct tension tests. For each specimen, the tension stiffening curve is plotted, and their behavior at various load levels is investigated. Average crack spacing, loss of cross-section area due to corrosion, the concrete contribution to the tensile response for different strain levels, and maximum bond stress developed at each corrosion level are studied, and their appropriate relationships are proposed. The main parameters considered in this investigation are: degree of corrosion ($C_w$), reinforcement diameter (d), reinforcement ratio (${\rho}$), clear concrete cover (c), ratio of clear concrete cover to rebar diameter (c/d), and ratio of rebar diameter to reinforcement percentage ($d/{\rho}$).

Ti$_3$SiC$_2$의 소성 변형 특성에 미치는 결정립 크기의 효과 (Effect if Grain Size on Plasticity of Ti$_3$SiC$_2$)

  • 이승건
    • 한국세라믹학회지
    • /
    • 제35권8호
    • /
    • pp.807-812
    • /
    • 1998
  • Mechanical properties of two types of polycrystlline {{{{ { { Ti}_{3 }SiC }_{2 } }} with different grain size were investigated. A fine grain {{{{ { { Ti}_{3 }SiC }_{2 } }} has a higher fracture strength and hardness. Plot of strength versus Vickers indentation load indicated that {{{{ { { Ti}_{3 }SiC }_{2 } }} has a high flaw tolerance. Hertzian indentation test using a spherical indenter was used to study elastic and plastic behavior in {{{{ { { Ti}_{3 }SiC }_{2 } }}. Indentation stress-strain curves of each material are made to evaluate the plasticity of {{{{ { { Ti}_{3 }SiC }_{2 } }} Both find and coarse grain {{{{ { { Ti}_{3 }SiC }_{2 } }} showed high plasticity. In-dentation stress-strain curve of coarse grain {{{{ { { Ti}_{3 }SiC }_{2 } }} deviated even more from an ideal elastic limit in-dicating exceptional plasticity in this material. Deformation zones were formed below the contact as well as around the contact area in both materials but the size of deformation zone in coarse grain {{{{ { { Ti}_{3 }SiC }_{2 } }} was much larger than that in fine grain {{{{ { { Ti}_{3 }SiC }_{2 } }} Intragrain slip and kink would account for high plasticity. Plastic behavior of {{{{ { { Ti}_{3 }SiC }_{2 } }} was strongly influenced by grain size.

  • PDF

합성보 전단연결부의 구조거동에 대한 비교 분석 (Analysis of a Load Carrying Behavior of Shear Connection at the Interface of the Steel-Concrete Composite Beam)

  • 신현섭
    • 한국강구조학회 논문집
    • /
    • 제17권6호통권79호
    • /
    • pp.737-747
    • /
    • 2005
  • 강재 보와 콘크리트 슬래브로 구성되어 지는 합성보에서 두 부재는 일반적으로 전단연결재에 의해 서로 합성되어져 일체적인 구조거동을 하게 된다. 현재까지 전단연결재로서는 스터드(stud)가 널리 사용되어지고 있다. 합성보의 구조적 거동은 사용된 부재의 재료적 특성 외에도 스터드에 의한 전단합성작용에 의해 많은 영향을 받게 된다. 합성보 전단연결부에서의 전단합성거동은 합성보에서가 아닌 단순화된 Push-Out 시험체(Push-Out Test Specimen)에 의해 실험적으로 결정되고 있다. 최근의 연구결과에 따르면, Push-Out 실험에서 얻은 전단 스터드의 합성거동과 실제 합성보에서의 전단합성거동에는 분명한 차이점이 존재하며, 특히 부분합성된 합성보에서는 그 차이가 매우 크다는 것이 밝혀지고 있다. 본 연구에서는 표준 Push-Out 시험체 및 합성보의 구조거동 해석을 위해, Push-Out 실험으로부터 결정되는 스터드에 대한 하중-상대변위 곡선의 도입이 필요 없는 3차원 유한요소모델을 개발하였다. 해석결과의 비교 분석으로부터 합성보 전단연결부에서의 합성거동을 평가할 수 있었고, 이를 Push-Out 실험결과와 비교하여 보았으며 전단합성거동의 차이점에 대한 구체적 원인을 찾을 수 있었다.

Distribution of shear force in perforated shear connectors

  • Wei, Xing;Shariati, M.;Zandi, Y.;Pei, Shiling;Jin, Zhibin;Gharachurlu, S.;Abdullahi, M.M.;Tahir, M.M.;Khorami, M.
    • Steel and Composite Structures
    • /
    • 제27권3호
    • /
    • pp.389-399
    • /
    • 2018
  • A perforated shear connector group is commonly used to transfer shear in steel-concrete composite structures when the traditional shear stud connection is not strong enough. The multi-hole perforated shear connector demonstrates a more complicated behavior than the single connector. The internal force distribution in a specific multi-hole perforated shear connector group has not been thoroughly studied. This study focuses on the load-carrying capacity and shear force distribution of multi-hole perforated shear connectors in steel-concrete composite structures. ANSYS is used to develop a three-dimensional finite element model to simulate the behavior of multi-hole perforated connectors. Material and geometric nonlinearities are considered in the model to identify the failure modes, ultimate strength, and load-slip behavior of the connection. A three-layer model is introduced and a closed-form solution for the shear force distribution is developed to facilitate design calculations. The shear force distribution curve of the multi-hole shear connector is catenary, and the efficiency coefficient must be considered in different limit states.

이중합성 교량의 복합스터드 전단연결부의 정적강도 평가 (Evaluation of Static Strength of Mixed Stud Shear Connection in Double Composite Bridges)

  • 김현호;심창수;윤광중;이필구
    • 한국강구조학회 논문집
    • /
    • 제17권5호통권78호
    • /
    • pp.549-559
    • /
    • 2005
  • 철도교는 강성이 주요한 설계인자이기 때문에 기존의 2거더 교량의 구조적 효율성을 높이기 위해서 이중합성 구조를 가진 철도교를 제안하였다. 일반적으로 강합성 연속교를 설계할 경우, 부모멘트 구간에 존재하는 콘크리트 바닥판은 인장에 저항하지 못한다고 가정하고 바닥판 단면을 무시하게 된다. 부모멘트 구간에서는 합성단면의 강성이 감소하게 되므로 이를 보완하기 위해 강재단면이 커지게 되는데, 이러할 경우 변단면의 적용이 불가피하게 되고 강합성형으로서의 장점이 반감된다고 할 수 있다. 이와 같은 문제점을 해결하기 위한 다양한 접근법이 존재하지만 그 중에서도 경간을 확대하고 강성이 중요한 설계인자가 되는 경우에 적절하게 사용될 수 있도록 제안된 교량의 형태가 이중합성구조이다. 따라서 본 연구에서는 이중합성 전단연결부의 거동을 파악하기 위하여 수평스터드, 수평스터드와 수직스터드가 함께 배치된 복합스터드 부재에 대한 push-out 실험을 수행하였다. 실험결과의 분석을 통하여 기존의 설계식과의 비교를 수행하고 정적 거동을 평가하였다.

Shear stiffness of headed studs on structural behaviors of steel-concrete composite girders

  • He, Jun;Lin, Zhaofei;Liu, Yuqing;Xu, Xiaoqing;Xin, Haohui;Wang, Sihao
    • Steel and Composite Structures
    • /
    • 제36권5호
    • /
    • pp.553-568
    • /
    • 2020
  • Steel-concrete composite structures have been extensively used in building, bridges, and other civil engineering infrastructure. Shear stud connectors between steel and concrete are essential in composite members to guarantee the effectiveness of their behavior in terms of strength and deformability. This study focuses on investigating the shear stiffness of headed studs embedded in several types of concrete with wide range of compressive strength, and their effects on the elastic behavior of steel-concrete composite girders were evaluated. Firstly, totally 206 monotonic push-out tests from the literature were reviewed to investigate the shear stiffness of headed studs embedded in various types of concrete (NC, HPC, UHPC etc.). Shear stiffness of studs is defined as the secant stiffness of the load-slip curve at 0.5Vu, and a formulation for predicting defined shear stiffness in elastic state was proposed, indicating that the stud diameter and the elastic modulus of steel and concrete are the main factors. And the shear stiffness predicted by the new formula agree well with test results for studs with a diameter ranging from 10 to 30 mm in the concrete with compressive strength ranging from 22.0 to 200.0MPa. Then, the effects of shear stiffness on the elastic behaviors of composite girders with different sizes and under different loading conditions were analyzed, the equations for calculating the stress and deformation of simply supported composite girders considering the influence of connection's shear stiffness were derived under different loading conditions using classical linear partial-interaction theory. As the increasing of shear stiffness, the stress and deflection at the most unfavorable section under partial connected condition tend to be those under full connected condition, but the approaching speed decreases gradually. Finally, the connector's shear stiffness was recommended for fully connection in composite girders with different dimensions under different loading conditions. The findings from present study may provide a reference for the prediction of shear stiffness for headed studs and the elastic design of steel-concrete composite girder.