• Title/Summary/Keyword: load-pull

Search Result 271, Processing Time 0.024 seconds

Comparison of the tribological behaviors of various organic molecular films (다양한 유기분자막의 마찰특성 비교)

  • ;;;V. Tsukruk
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.06a
    • /
    • pp.49-54
    • /
    • 2001
  • Monolayers such as self-assembled monolayer (SAM) have received considerable attention to reduce stiction and friction in micro-devices and microelectromechanical systems (MEMS). Various organic molecular films were investigated to obtain better understanding of their tribological behaviors and adhesion property. The organic molecular films studied in this work are: epoxysilane SAMs, octadecyltricholosilane (OST), multi-layers composed of epoxysilane SAMs, poly〔styrene-b-(ethylene-co-butylene)-b-styrene〕(SEBS) and compound of epoxy resin and poly (paraphenylene) (EP/PPP). The pull-off forces of these films were also obtained from force-distance curves measured in static mode of operation of atomic force microscope (AFM). Tribological tests were conducted with a ball-on-flat reciprocating friction tester. The OST showed the lowest pull-off force, indicating its low adhesion property. It was revealed that, the OST, EP/PPP and the multi-layer of epoxysilane SAMs, SEBS and EP/PPP exhibited good tribological properties at the lower load (0.3 N) whereas the OST showed best performance at the higher load (1.8 N).

  • PDF

Ergonomic and Performance Analyses of a Pull-type Prayer for Floriculture in Greenhouse (시설화훼용 견인형 방제기의 작업자세 및 성능 분석)

  • Lee, Seung-Ki;Kim, Woong
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.426-433
    • /
    • 2010
  • This study was conducted to develop a pull-type sprayer which performs the safe spraying with improved ergonomic postures while pesticide spraying of roses in floricultural facilities. The performance of the ergonomically designed sprayer was analyzed with a comparison of a conventional spray method. The pull-type sprayer, consisting of power pump, hose and nozzle parts was designed to manually pull and spray to upward and horizontal directions. From the analysis of postures with the RULA method, the labor load to arm and wrist using the pull-type sprayer was less than that with conventional power sprayer, so that the intensity of labor reduces. Working capacity with pull-type sprayer was two-fold greater than the conventional power sprayer. After performing pesticide spraying with the pull-type sprayer, the operating cost was reduced to \585,000/yr, which is 79% less than that of cost (\2,197,500/yr) for using conventional power sprayer.

High Frequency Circuit Design using Feedback Control with Body Load Fluctuation for Pain Relief Therapy (통증 완화 치료기용 인체 부하 변동에 따른 피드백 제어가 가능한 고주파 회로 설계)

  • Park, Chul-Won;Won, Chul-Hee
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.45-49
    • /
    • 2013
  • High frequency system has been used for the purpose of skin care and obesity treatment, by high-frequency energy is applied to the human body generates deep heat. Conventional high frequency system could not selection control by depending on the body load fluctuations. Such as burns and side effects have been reported by system instability and then therapeutic effect is insufficient. During treatment, objective information about the status of the patient was no. Because of treatment methods are subjective, and so tailored treatments were impossible. In this paper, high frequency medical system with sinusoidal frequency characteristics without distortion of the Push pull switching scheme for pain relief therapy was designed. And control circuit that was designed by feedback using the output changes according to the body-load fluctuation. Last, power circuit for efficient control the heat generated from the hardware was proposed.

Development of Removable-Strand Compression Anchor (압축형 제거 앵커의 개발 및 성능 평가)

  • 김낙경;김성규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.339-346
    • /
    • 2001
  • For temporary excavation support in private land area, the strand of ground anchor should be removed In order to get permission to install anchors. The extractable or removable-strand compression anchor system was developed and evaluated by a series of pull-out load tests. Anchor pull-out tests were performed on seven instrumented full-scale low-pressure grouted anchors installed in weathered soil at the Geotechnical Experimentation Site at Sungkyunkwan University, Four anchors are the compression type anchors and three are the tension anchors. Performance test, creep test, and long term relaxation test were performed and presented. Load distributor was developed in order to distribute large compressive stresses in grout.

  • PDF

Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test (실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.

A Study on the Adhesive Characteristics of Nano Scale Particles Considering Asperity Interaction (거칠기 돌기의 상호작용을 고려한 미세입자의 응착특성에 관한 연구)

  • Lee, Chang-Hun;Lee, Kyong-Hun;Yoon, Jun-Ho;Shin, Young-Eui
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.56-62
    • /
    • 2008
  • In this paper, elastic and plastic adhesion index was very important in deciding adhesive characteristics and varying elastic and plastic index, dimensionless load and pull-off force were analyzed and simulated. Finally, using AFM, experimental surface roughness parameters of substrates and pull-off force between tip and substrates were produced. Using these values, pull-off forces were calculated and were compared with experimental pull-off forces. Through simulation and experiment, it was found that interaction of asperity also had very important influence on adhesive contact.

Mechanical Properties on the Pull-Out Response of Steel Fibers Embedded in Cementitious Matrices (시멘트 매트릭스 내 강섬유의 매입 일반에 관한 성능)

  • Jeon Esther;Kim Sun Woo;Park Wan Shin;Han Byung Chan;Hwang Sun Kyung;Yun Hyun Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.762-765
    • /
    • 2004
  • The main objective of this study is to provide a parametric evaluation of the pull-out response of steel fibers embedded in cementitious matrices. The various parameters controlling the behavior of the bond stress versus end slip relationship are analyzed; their effects on the entire pull-out load versus end slip response and the corresponding pull-out energy up to total pull-out are investigated. Also discussed are the effects of the fiber length, the water/binder ratio of the mixtures and embedded length.

  • PDF

Research Dual Band Power Amplifier using PBG Structure (PBG 구조를 이용한 Dual Band 전력증폭기 연구)

  • 전익태;서철헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.8
    • /
    • pp.788-793
    • /
    • 2004
  • This paper proposes new configuration for the dual power amplifier that operates at 5.8 GHz for the wireless LAN and 1.8 GHz for the PCS. It dose not select the input signal but amplify the dual band signals simultaneously. Broadband diplexer is used at the input to separate the dual band signals. Output power of each amplifier is 1 W. The PBG is employed to improve the performance of power amplifier. Generally, the PBG is employed at the end of output matching network. But in this paper, the PBG is employed in the load pull output matching circuit of amplifer to maximize the output power.

Analysis of Optimum Impedance for X-Band GaN HEMT using Load-Pull (로드-풀을 이용한 X-Band GaN HEMT의 최적 임피던스 분석)

  • Kim, Min-Soo;Rhee, Young-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.5
    • /
    • pp.621-627
    • /
    • 2011
  • In this paper, we analysed performance for on-wafer GaN HEMT using load-pull in X-band, and studied optimum impedance point based on analysis result. We suggested method of optimum performance device by analysis of optimum impedance for solid state device on-wafer condition before packaging. The measured device is gate length 0.25um, and gate width is 400um, 800um. device 400um is performed $P_{sat}$=33.16dBm, PAE=67.36%, Gain=15.16dBm, and device 800um is performed $P_{sat}$=35.91dBm, PAE=69.23%, Gain=14.87dBm.

Response of square anchor plates embedded in reinforced soft clay subjected to cyclic loading

  • Biradar, Jagdish;Banerjee, Subhadeep;Shankar, Ravi;Ghosh, Poulami;Mukherjee, Sibapriya;Fatahi, Behzad
    • Geomechanics and Engineering
    • /
    • v.17 no.2
    • /
    • pp.165-173
    • /
    • 2019
  • Plate anchors are generally used for structures like transmission towers, mooring systems etc. where the uplift and lateral forces are expected to be predominant. The capacity of anchor plate can be increased by the use of geosynthetics without altering the size of plates. Numerical simulations have been carried out on three different sizes of square anchor plates. A single layer geosynthetic has been used as reinforcement in the analysis and placed at three different positions from the plate. The effects of various parameters like embedment ratio, position of reinforcement, width of reinforcement, frequency and loading amplitude on the pull out capacity have been presented in this study. The load-displacement behaviour of anchors for various embedment ratios with and without reinforcement has been also observed. The pull out load, corresponding to a displacement equal to each of the considered maximum amplitudes of a given frequency, has been expressed in terms of a dimensionless breakout factor. The pull out load for all anchors has been found to increase by more than 100% with embedment ratio varying from 1 to 6. Finally a semi empirical formulation for breakout factor for square anchors in reinforced soil has also been proposed by carrying out regression analysis on the data obtained from numerical simulations.