• 제목/요약/키워드: load test

검색결과 8,084건 처리시간 0.041초

22.9[kV] 모선의 계절별 부하특성에 관한 연구 (A Study on the Seasonal Load Characteristics in 22.9[kV] Bus)

  • 이종필;임재윤;지평식;김기동;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.279-286
    • /
    • 2001
  • A load modeling, micro method, is performed by component load modeling, load composition rate estimation and aggregation of component load model, etc. The load model obtained from this process must be applied to actual load bus to verify it and to get reliable load model. But it is difficult to apply every load bus due to al lot of load buses and complex experiment. This paper proposed the field test method in load bus to verify the load modeling. For appropriate field test, representative load buses are selected by the proposed algorithm considering the composition rate of user category in all load buses. The field tests were performed at selected load buses to obtain load characteristics of bus by time and seasonal without blackout. The results of measurement and analysis are presented in detail.

  • PDF

최대 산소소모량 평가에 있어서 자전거 에르고미터를 이용한 최대하부하검사방법의 타당도 (Validity on Submaximal Load Tests Using Cycle Ergometer in Evaluation of Maximum Oxygen Consumption Volume)

  • 강동묵;박용균;이용환;설진곤
    • 한국산업보건학회지
    • /
    • 제16권2호
    • /
    • pp.145-151
    • /
    • 2006
  • Because of the limitations of maximal load tests for $VO_2max$, submaximal tests using cycle ergometer are used for field study in general. This study was conducted to evaluate validity of various submaximal tests using cycle ergometer. This study had been conducted during May to June 2005, which subjects were 15 males and 15 females in twenties. Experiment was performed with restrictive conditions which regulated ambient temperature, noise, and entrance restriction. Submaximal load test protocols including YMCA Protocol (YP), ${\AA}strand$-Rhyming Protocol (ARP), Relative heart ratio Protocol (RP), and Ramp test Protocol (RP) were compared with maximal load test which used gas mask analyser using Bruce Protocol. All submaximal load tests were highly related with maximal load test (Spearman's correlation coefficient > 0.60) with statistical significancy. The highest correlation coefficient with maximal test was found in RP. Three submaximal test results except RP were significantly different with maximal test results (Wilcoxon rank test). All submaximal tests had high validity. The reason why RP had highest validity might be that it represents Korean physical strength and individual differences better than the others. RP using cycle ergometer would make easy to study for physical capacity evaluation and field workload estimation.

탄소섬유강화플라스틱 재료 레저선박의 구조강도 평가를 위한 시험설비 구축과 운용에 관한 연구 (The Development of Structural Test Facility for the Strength Assessment of CFRP Marine Leisure Boat)

  • 정한구;장양;염덕준
    • 대한조선학회논문집
    • /
    • 제54권4호
    • /
    • pp.312-320
    • /
    • 2017
  • This paper deals with the development of structural test facility for the strength assessment of marine leisure boat built from carbon fiber reinforced plastics (CFRP) materials. The structural test facility consists of test jig, load application and control system, and data acquisition system. Test jig, and load application and control system are designed to accommodate various size and short span to depth ratios of single skin, top-hat stiffened and sandwich constructions in plated structural format such as square and rectangular shapes. A lateral pressure load, typical and important applied load condition to the plates of the hull structure for marine leisure boat, is simulated by employing a number of hydraulic cylinders operated automatically and manually. To examine and operate the structural test facility, five carbon/epoxy based FRP square plates having the test section area of $1m^2$, which are part of CFRP marine leisure boat hull, are prepared and they are subjected to monotonically increasing lateral pressure loads. In the test preparation, considering the symmetry of the plates geometry, various strain gauges and linear variable displacement transformer are used in conjunction with data acquisition system utilizing LabVIEW. From the test observation, the responses of the CFRP hull structure of marine leisure boat are understood by obtaining load to deflection and strain to load curves.

Agricultural tractor roll over protective structure (ROPS) test using simplified ROPS model

  • Ryu-Gap Lim;Young-Sun Kang;Dae-Hyun Lee;Wan-Soo Kim;Jun-Ho Lee;Yong-Joo Kim
    • 농업과학연구
    • /
    • 제49권4호
    • /
    • pp.771-783
    • /
    • 2022
  • In this study, the feasibility of alternative tractor Roll Over Protective Structure (ROPS) designed to evaluate conditions required for testing was confirmed. In accordance with Organization for Economic Cooperation and Development (OECD) code 4, the required load energy of the tractor ROPS was determined. First, the tractor ROPS test was performed and a repeated test was performed using a simplified ROPS as an alternative tractor ROPS. The test procedure is first rearward, second lateral, and last forward based on ROPS. The load test device consists of a load cell that measures force and a LVDT that measures deformation. Precision was confirmed by calculating the relative standard deviation of the simplified ROPS repeated test. Accuracy was analyzed by calculating the mean relative error between the mean measured values in the simplified ROPS test and the tractor ROPS test. As a result, the relative standard deviation was less than 2.5% for force and 3.3% for maximum deformation overall, showed the highest precision in lateral load. The mean relative error value for force measured at the lateral load of simplified ROPS was 0.5%, showing the highest accuracy. In the front load test, the mean relative error of maximum deformation was 20.5%, showing the lowest accuracy. The mean relative error (MRE) was high in the forward load test was because of structural factors of the ROPS. The simplified ROPS model is expected to save money and time spent preparing tractors.

Load Test Simulator Development for Steam Turbine-Generator System of Nuclear Power Plant

  • Jeong, Chang-Ki;Kim, Jong-An;Kim, Byung-Chul;Choi, In-Kyu;Woo, Joo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1384-1386
    • /
    • 2005
  • This paper focuses on development of load test simulator of a steam turbine-generator in a nuclear power plant. When load is taken off from electrical power network, it is very difficult to effectively control the steam flow to turbine of the nuclear turbine-generator, because of disturbances, such as electrical load and network unbalance on electrical network. Up to the present time, the conventional control system has been used for the load control on nuclear steam generator, owing to the easy control algorithms and the advantage which have been proven on the nuclear power plant. However, since there are problems with stability control during low power and start-up, only a highly experienced operator can operate during those procedures. Also, a great deal of time and an expensive simulator is needed for the training of an operator. The KEPRI is developed simulator for 600MW nuclear power plant to take a test of generator load rejection, throttle valve, and turbine load control. Total load test is implemented before start up.

  • PDF

과학로케트 날개조립체의 구조강도시험 및 안전성 평가 (Structural Test and Safety Evaluation for Fin Assembly of Scientific Sound Rocket)

  • 허용학;김갑순;주진원
    • 대한기계학회논문집
    • /
    • 제18권12호
    • /
    • pp.3395-3403
    • /
    • 1994
  • The structural test technique and equipment for strength test of astronautical structures, such as rocket, were presented in this paper. Structural strength tests of the fin assembly with fin and fin frame in the scientific sound rocket were performed with load levels of 100% limit load and 150% ultimate load of design lift force. Safety factors in each part of the fin assembly were calculated at these two load levels and the stiffnesses based on the measured deflection of fin assembly and strains on fin and fin frame were evaluated at these two load level. As the result of structural test, the fin assembly was estimated to be safe.

전기철도 급전시스템의 안정화를 위한 전압강하 측정 결과 분석 (Measurement and Analysis of Voltage Drop in Traction Power Supply System)

  • 김주락;이영흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2210-2211
    • /
    • 2011
  • Load capacity varies according to a day of the week in traction power supply system, because time schedule in railway is changed as demand for passengers and freights. Therefore, Voltage drop also varies as load capacity. In Korea railway, Voltage collected from catenary in train is decreased, as load supplied traction power supply system is increased. Therefore, investigation about voltage drop should be performed, before development of countermeasure against voltage drop. The investigation can be performed by simulation or field test. Naturally, field test is more precise than simulation. In addition, field test should be carried out at peak load. This paper presents test and analysis about voltage drop in railway. The test is performed in both a day of the week and weekend. The analysis is figured out comparison load capacity between two days and voltage drop across terminal.

  • PDF

신형전동차 대차프레임 하중시험결과 분석 연구 (A Study on Analysis of Load Test Result of Bogie Frame for New Electrical Multiple Unit)

  • 김원경;윤성철;전창성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1056-1062
    • /
    • 2005
  • This paper describes the results of structure analysis and load test of a bogie frame. The purpose of the test is to evaluate the safety and functionality of the bogie frame under maximum load. The bogie system consist of the bogie frame, suspensions, whee/sets, a brake system and a transmission system. Of these components, the bogie frame is the major component subjected to the vehicle and passenger loads. The evaluation method used the JIS E 4207 specifications throughout static load test. The test results have shown the bogie frame to be safe under design load conditions.

  • PDF

Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

  • Kim, Si Moon;Yun, Wan No;Jang, Cheol Ho;Park, Se Ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.83-88
    • /
    • 2016
  • This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.

RC 슬래브 교량의 현장재하시험을 통한 안전성 평가 (Safety Evaluation through Field Load Test of RC Slab Bridge)

  • 조한민
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.