• Title/Summary/Keyword: load sizes

Search Result 323, Processing Time 0.028 seconds

Dependence of the Diamond Coating Adhesion on the Microstructure of WC-Co Substrates (WC-Co계 미세조직에 따른 CVD 다이아몬드 코팅막의 접착력 변화)

  • Lee, Dong-Beum;Chae, Ki-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.10 s.269
    • /
    • pp.728-734
    • /
    • 2004
  • The effect of microstructure of WC-Co substrates which have different WC grain sizes from submicron to 5 $\mu$m on the diamond-substrate adhesion strength was investigated. The substrates were pre-treated by two methods : chemical etching with Murakami's solution and subsequently with $H_2SO_4$, and thermal heat-treatment. The adhesion strength was estimated by degree of peeling after Rockwell indentation. Diamond films of 20 $\mu$m thickness deposited on the heat-treated substrates showed an excellent adhesion strength at the load of 100 kg, which ascribed to the large and elongated WC grains. However, the cutting edge of insert was deformed after heat treatment and the surface morphology of heat treated substrate strongly affected on the surface roughness of the deposited diamond films. On the contrary, the diamond film of 10 $\mu$m in thickness on the chemically etched substrates of average WC grain size over 2 $\mu$m showed good adhesion strength enough not to peel-off under a load of 60 kg. Especially, the substrate of average WC grain size over 5 $\mu$m exhibited much improved reliability of adhesion comparing with the substrate of average grain size under 2 $\mu$m. No substrate deformation was observed in this case after the chemical etching, which is more advantageous and more practical in terms of precious machining than the heat treatment case.

A Preliminary Study for Assessing the Risk of Road Collapse Using Accelerated Pavement Testing (도로함몰 위험도 평가를 위한 실대형 포장가속시험 기초 연구)

  • Park, Hee Mun;Kim, Yeon Tae;Choi, Ji Young;Kim, Ki Hyun
    • International Journal of Highway Engineering
    • /
    • v.18 no.5
    • /
    • pp.57-62
    • /
    • 2016
  • PURPOSES : The objective of this study is to evaluate the effect of size and depth of cavities on the pavement failure using the full-scale accelerated pavement testing. METHODS : A full-scale testbed was constructed by installing the artificial cavities at a depth of 0.3 m and 0.7 m from the pavement surface for accelerated pavement testing. The cavities were made of ice with a dimension of 0.5 m*0.5m*0.3m, and the thickness of asphalt and base layer were 0.2 m and 0.3 m, respectively. The ground penetrating radar and endoscope testing were conducted to determine the shape and location of cavities. The falling weight deflectometer testing was also performed on the cavity and intact sections to estimate the difference of structural capacity between the two sections. A wheel loading of 80 kN was applied on the pavement section with a speed of 10 km/h in accelerated pavement testing. The permanent deformation was measured periodically at a given number of repetitions. The correlation between the depth and size of cavities and pavement failure was investigated using the accelerated pavement testing results. RESULTS : It is found from FWD testing that the center deflection of cavity section is 10% greater than that of the intact section, indicating the 25% reduction of modulus in subbase layer due to the occurrence of the cavity. The measured permanent deformation of the intact section is approximately 10 mm at 90,000 load repetitions. However, for a cavity section of 0.7 m depth, a permanent deformation of 30 mm was measured at 90,000 load repetitions, which is three times greater than that of the intact section. At cavity section of 0.3 m, the permanent deformation reached up to approximately 90 mm and an elliptical hole occurred at pavement surface after testing. CONCLUSIONS : This study is aimed at determining the pavement failure mechanism due to the occurrence of cavities under the pavement using accelerated pavement testing. In the future, the accelerated pavement testing will be conducted at a pavement section with different depths and sizes of cavities. Test results will be utilized to establish the criteria of risk in road collapse based on the various conditions.

Uplift Capacity of Shallow Foundation for Greenhouse (온실용 얕은기초의 인발저항력 검토)

  • Yun, Sung Wook;Choi, Man Kwon;Lee, Si Young;Kang, Dong Hyeon;Moon, Sung Dong;Yu, Chan;Yoon, Yong Cheol
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.187-195
    • /
    • 2015
  • In this study, a field test of uplift load was carried out using 15 greenhouse foundations fabricated in full scale on a sand soil to examine the uplift capacity of plastic film greenhouse and glasshouse foundations for disasterproof standard. As a result, the maximum uplift capacity of the target greenhouse foundations was shown to be in the range from 11.6kN to 82.4kN according to the differences between the forms and sizes of the foundation. As a result of the examination of the applicability using the field uplift load test result of the theoretical equation proposed for maximum uplift capacity calculation of greenhouse foundations, we found that in general, the conventional theoretical equation for the calculation provided numerical values close to the field test results. However, the soil considered in this study was a sand; thus, in the future, verifying the conventional theoretical equation for the uplift capacity calculation of a cohesive soil would be necessary.

A Study on the Activities of IV Team In the Children's Hospital (소아병원의 정맥주사팀 활동에 대한 조사연구)

  • Hwang, Jeong Hae;Hwang, Jee In;Kim, Mi Ran;Shin, Hee Young;Ahn, Hyo Seop
    • Quality Improvement in Health Care
    • /
    • v.6 no.1_2
    • /
    • pp.92-106
    • /
    • 1999
  • Background : In many university hospitals, intravenous(IV) therapies and samplings had been one of the most important works of doctors who are in training. However, recently as patient oriented care is becoming more weighted for qualified health service IV therapies should be the works of specialized personnels. This study was conducted to investigate the medical staff's perception on IV team, to survey patient or parent's expectation on IV team, and to assess the frequency of IV therapy related complications and the characteristics of phlebitis among the hospitalized children. Methods : We collected data prospectively before the start of IV team from February 22 to February 29. 1999 and from September 27 to October 3, 1999, 6 months after beginning of IV team at Seoul National University Children's Hospital. IV team started their activities from March 1, 1999. General pediatric wards were not included for the IV and sampling team and oncology ward and surgical units were all included for the IV and sampling team's work. IV specialist was the well trained nurse who had been working in the field of pediatrics especially for the oncology patients. The subjects of this study were medical staffs who were working in children's hospital as doctors in training and patients who were treated with IV therapies in children's hospital during the same period. Results : Doctors responded that IV team need to be organized for IV care and expected IV team could reduce their work load. Parents of patients also responded IV team was very improtant to perform high quality IV care. They had willingness to pay extra charge for IV team care. In the wards where IV team did not work, they used various kinds and sizes of catheters, but in the wards where IV team worked, they needed just one or two types of catheters. As the exact role of IV team is not still established, job description is needed between the IV team and medical doctors. In the aspects of medical costs. it could save the materials for the IV also. Conclusion : This study showed that IV team could increase patient's satisfaction with decrease of medical doctors work load and concomitantly could save the costs of IV materials. And for the expansion of the IV team, job description is needed and for the total care of the children IV specialist and sampling team should expand their roles.

  • PDF

Nitrogen and Phosphorus Excretion of Nile Tilapia (Oreochromis niloticus) Fed Commercial Diets (시판 사료를 먹인 틸라피아( Oreochromis nijoticus) 의 질소 및 인 부하량)

  • KIM Youhee;JO Jae-Yoon;JEONG Kwan-Sik
    • Journal of Aquaculture
    • /
    • v.7 no.3
    • /
    • pp.165-175
    • /
    • 1994
  • Attempts were made to find out nitrogen and phosphorus loads to aquatic environment resulting from feeding Nile tilapia (Oreochromis niloticus). Two different size groups, small and large, were used. The average sizes of small and large tilapia were 65.2 g and 389.2 g respectively, and three kinds of commercial diets were used for each size. The 3 kinds of commercial diets for tilapia contained in average 33.8% crude protein ($5.4\%$ nitrogen) and $1.4\%$ total phosphorus. The load of nitrogen and phosphorus were measured by subtracting the amounts of nutrients retained in the body of fish from consumed nutrients. Sixty, five percentage of total feces was excreted within 24 hours after feeding at $23^{\circ}C$. Nitrogen content in the feces was higher in large fish than small ones. The apparent digestibility of dietary protein for small and large tilapia was $90.0\%$ and $89.7\%$, respectively. Availability of dietary phosphorus for small and large tilapia was $44.7\%\;and\;51.4\%$, respectively. The total load of nitrogen and phosphorus per 1 metric ton of tilapia production was 49.5kg and 6.3kg, respectively, for small ones with feed conversion ratio (FCR) of 1.4, and 61.3 kg and 13.4kg, respectively, for large ones with the FCR of 1.8. Nitorgen balance appeared that small and large tilapia excreted $7.1\%\;and\;9.9\%$ of consumed nitrogen through fecal-nitrogen and $55.5\%\;and\;62.3\%$ through urine and gills, retaining $37.4\%\;and\;27.8\%$ in the body, respectively. These results show that small fish pollute less than large fish, excreting less and retaining more nutrients in the body.

  • PDF

Preparation of Uniform Porous Carbon from Mesophase Pitch and Its Characteristics of Catalyst Support for the Direct Methanol Fuel Cell (메조페이스 핏치로부터 균질한 다공성 탄소 제조 및 이를 이용한 직접 메탄올 연료전지의 촉매 담지체 특성)

  • Nam, Ki-Don;Kim, Tae-Jin;Kim, Sang-Kyung;Lee, Byoung-Rok;Peck, Dong-Hyun;Ryu, Seung-Kon;Jung, Doo-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.17 no.2
    • /
    • pp.223-228
    • /
    • 2006
  • Pore-size controlled porous carbons for the catalyst supports of the direct methanol fuel cell were prepared from the mesophase pitch by using the silica spheres with different sizes. Pitch solution in THF and spheres were mixed, carbonized and etched by 5 M NaOH to make porous carbon. Specific surface area of the porous carbons was $14.7{\sim}87.7m^2/g$ and average pore diameter was 50~550 nm which were dependent on the size of silica spheres. Aqueous reduction method was used to load 60 wt% PtRu on the prepared porous carbon supports. The electro-oxidation activity of the supported 60 wt% Pt-Ru catalysts was measured by cyclic voltammetry and unit cell test. For the 60 wt% Pt-Ru/porous carbon synthesized by 50 nm silica, current density value in the cyclic voltammetry test was $123mA/cm^2$ at 0.4 V and peak power density in the unit cell test were 105 and $162mW/cm^2$ under oxygen at 60 and $80^{\circ}C$, respectively.

Evaluation of Reinforcement Effect of Rock Bolts in Anisotropic Rock Mass Using Tunnel Scaled Model Tests (터널 축소모형실험을 통한 이방성 암반내 록볼트의 보강효과 검토)

  • Kim, Jong-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.442-456
    • /
    • 2018
  • Scaled model tests were performed to evaluate the reinforcement effect of rock bolts in anisotropic rock mass. For this purpose, two tunnel cases were experimented which had different tunnel sizes, rock strengths, anisotropic angles and coefficients of lateral pressure. The fully grouted rock bolts of the D25 deformed bar were modeled as the basting pins with bead and were systematically installed at the roof and the side wall of the model tunnel. As results of the first case experimentations, the unsupported model showed initial crack at the roof of tunnel, but the supported model with rock bolts showed initial crack at the floor of tunnel where rock bolts were not installed. The crack initiating pressure and the maximum pressure of the supported model with rock bolts were 11% and 7% larger than those of the unsupported model, respectively. Moreover, the effect of the existing discontinuities in anisotropic rock mass on the fracture behavior of tunnel was reduced in the supported model, and so the reinforcement effect of rock bolt turned out to be experimentally verified. As results of the second case experimentations considering different support patterns, the crack initiating pressures of models were larger and the reduction ratios of tunnel area according to applied load were smaller as the length and the quantity of rock bolts were larger. Therefore, it was found that the performance of the rock bolts turned out to be improved as they were larger.

Friction of calcium phosphate brackets to stainless steel wire (인산칼슘재 브라켓과 강선사이의 마찰저항에 관한 연구)

  • Joo, Hyo-Jin;Park, Young-Guk
    • The korean journal of orthodontics
    • /
    • v.37 no.5
    • /
    • pp.376-385
    • /
    • 2007
  • Esthetic brackets which resemble the color of natural teeth have been widely used. But the frictional resistance of ceramic brackets, a typical esthetic bracket, is greater than that of metal brackets. The purpose of this study was to measure the frictional resistance of the new calcium phosphate brackets (CPB) which were recently developed and to evaluate its clinical usability by comparing the frictional differences of CPB with metal brackets and metal slot inserted ceramic brackets. Methods: Experimental groups were CPB (Hyaline II, Tomy, Tokyo, Japan), metal bracket (Kosaka, Tomy, Tokyo, Japan) and metal slot inserted ceramic bracket (Clarity, 3M Unitek, Monrovia, CA, USA). All of the brackets had 0.022-inch slot sizes. The brackets were tested with $0.019\;{\times}\;0.025$ inch stainless steel wire (3M Unitek, Monrovia, CA, USA). A biologic model was used to simulate the situation which would occur during orthodontic treatment with fixed appliances. Retraction force was applied at a speed of 5 mm/min for 30 seconds. The frictional resistance was measured on a universal testing machine (Instron 4467, Instron, Norwood, MA, USA). Results: CPB showed significantly higher friction than metal brackets (p < 0.05) and lower friction than metal slot inserted ceramic brackets (p < 0.01). Conclusions: CPB can be considered to be a useful orthodontic esthetic bracket with respect to frictional resistance, as its friction is remarkably lower than that of metal slot inserted ceramic brackets.

Development and Uncertainty Assessment of Interface Friction Prediction Equation Between Steel Surface and Cohesionless Soils (강재면과 사질토 사이의 경계면 마찰각 예측식 개발 및 불확실성 평가)

  • Lee, Kicheol;Kim, So-Yeun;Kim, Dongwook
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.2
    • /
    • pp.33-40
    • /
    • 2018
  • Characteristics of interface friction between cohesionless soils and geotechnical structure surfaces play an important role in the analysis of earth load and resistance on the structure. In general, geotechnical structures are mainly composed of either steel or concrete, and their surface roughnesses with respect to soil particle sizes influence the interface characteristics between soils and the structures. Accurate assessment of the interface friction characteristics between soils and structures is important to ensure the safety of geotechnical structures, such as mechanically stabilized earth walls reinforced with inextensible reinforcements, piles embedded into soils, retaining wall backfilled with soils. In this study, based on the database of high quality interface friction tests between frictional soils and solid surfaces from literature, equation representing peak interface friction angle is proposed. The influential factors of the peak interface friction angle are relative roughness between soil and solid surface, relative density of frictional soil, and residual (constant volume) interface friction angle. Futhermore, for the developed equation of the interface friction angle, its uncertainty was assessed statistically based on Goodness-of-fit test results.

The Influence of Sensory Interference Arising from View-Height Differences on Visual Short-Term Memory Performance (조망 높이의 차이가 초래한 감각적 간섭이 시각단기기억 수행에 미치는 영향)

  • Ka, Yaguem;Hyun, Joo-Seok
    • Science of Emotion and Sensibility
    • /
    • v.23 no.1
    • /
    • pp.17-28
    • /
    • 2020
  • Lowering observers' view-height may increase the amount of occlusion across objects in a visual scene and prevent the accurate identification of the objects in the scene. Based on this possibility, memory stimuli in relation to their expected views from different heights were displayed in this study. Thereafter, visual short-term memory (VSTM) performance for the stimuli was measured. In Experiment 1, the memory stimuli were presented on a grid-background drawn according to linear perspectives, which varied across observers' three different view-heights (high, middle, and low). This allowed the participants to remember both the color and position of each memory stimulus. The results revealed that testing participants' VSTM performance for the stimuli under a different memory load of two set-sizes (3 vs. 6) demonstrated an evident drop of performance in the lowest view-height condition. In Experiment 2, the performance for six stimuli with or without the grid-background was tested. A similar pattern of performance drop in the lowest condition as in Experiment 1 was found. These results indicated that different view-heights of an observer can change the amount of occlusion across objects in the visual field, and the sensory interference driven by the occlusion may further influence VSTM performance for those objects.