• 제목/요약/키워드: load margin

검색결과 254건 처리시간 0.024초

바이오 가스를 사용하는 가스터빈 열병합 시스템의 전부하 및 부분부하 운전특성 해석 (A Study on Full and Part Load Operations of a Biogas-fired Gas Turbine Combined Heat and Power System)

  • 강도원;이종준;김동섭;허광범
    • 한국유체기계학회 논문집
    • /
    • 제14권2호
    • /
    • pp.35-40
    • /
    • 2011
  • This study analyzed the influence of firing biogas on the performance and operation of a gas turbine combined heat and power (CHP) system. A reference CHP system designed with natural gas fuel was set up and off-design simulation was made to investigate the impact of firing biogas in the system. Changes in critical operating parameters such as compressor surge margin and turbine blade temperature caused by firing biogas were examined, and a couple of operating schemes to mitigate their changes were simulated. Part load operation of the biogas-fired system was compared with that of natural-gas fired system, and it was found that as long as the two system produce the same electric power output, they exhibit nearly the same heat recovery.

송전계통에서의 공급능력여유의 평가에 관한 연구 (A Study for Load Supplying Margin of Transmission Networks)

  • 송길영;남궁재용;최재석;김용하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.513-515
    • /
    • 1995
  • Based on the concept of Load Supplying Capability of a transmission network, we provides an information concerning network adequacy. In particular this paper describes an algorithm regarding load supplying margin of transmission networks. And a different growth rate is assigned to each load point so that various demand characteristics can be taken into consideration at respective locations. In addition to this, in this paper, both generation and transmission equipment will be considered in determining the system capability. A 10 bus model system is used to demonstrate the capability of the proposed algorithm.

  • PDF

Pap Smear Combined with HPV Testing: A Reasonable Tool for Women with High-grade Cervical Intraepithelial Neoplasia Treated by LEEP

  • Mo, Ling-Zhao;Song, Hong-Lin;Wang, Jian-Li;He, Qing;Qiu, Zhang-Can;Li, Fei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권10호
    • /
    • pp.4297-4302
    • /
    • 2015
  • Background: To evaluate HPV testing by Hybrid Capture II (HCII) in conjunction with cytology in detecting the residual/recurrence disease after treatment of high-grade cervical intraepithelial neoplasia (CIN II-III) with loop electrosurgical excision procedure (LEEP). Materials and Methods: A retrospective review of 158 patients with histologically confirmed CIN II-III who underwent LEEP between January 2011 and October 2012 was conducted. Post-treatment control was scheduled at the 3rd, 6th, 12th and 18th month. All patients were followed up by Pap smear and HR-HPV genotype and viral load testing. Results: Pre-treatment, HR-HPV DNA, was detected in all specimens of the patients. At follow-up, 25 patients were diagnosed as the residual/recurrent disease during the FU visit, among whom, 16 patients with positive margin: 13 patients (52%) with HR-HPV DNA+/cytology+, 2 patients (8%) with HR-HPV DNA+/cytology-, 1 patient (4%) with cytology+/HR-HPV DNA-; 9 patients with clean margin - 5 patients (55.6%) with HR-HPV DNA+/cytology+; 2 patients (22.2%) with HRHPV DNA+/cytology-, 2 patients (22.2%) with cytology+/HR-HPV DNA-. None of them persisting HR-HPV DNA-/cytology-with positive or negative margin was identified as the residual/recurrent disease. The majority of residual/recurrent disease was detected at the 12th and 18th month FU, and there was almost no difference in the sensitivity and negative predictive value (NPV) between at the 3rd month and the 6th month FU visits. 14 residual/recurrence disease (14/46:30.4%) had pre-treatment high viral load (>5 000 RUL/PC) and 11 (11/112, 9.8%) with pre-treatment low viral load, P<0.05. Conclusions: (1) The persistence HR-HPV DNA is the root cause of the residual/recurrent disease for the women treated for high-grade CIN; the pre-treatment viral load and margin can be seen as the predictor. (2) The FU visit beginning at the 6th month post-treatment and lasting at least 24 months with the combination of cytology and HPV testing. (3) Patients with high pre-treatment HPV load, which is considered as one risk of developing the residual/recurrent disease, should be paid more attention (especially above 500RUL/PC) to by clinicians.

확률론적 기법을 이용한 시변 가용송전용량 결정 (Probabilistic Approach to Time Varying Available Transfer Capability Calculation)

  • 신동준;김규호;김진오
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권11호
    • /
    • pp.533-539
    • /
    • 2005
  • According to NERC definition, Available Transfer Capability (ATC) is a measure of the transfer capability remaining in the physical transmission network for the future commercial activity. To calculate Available Transfer Capability, accurate and defensible Total Transfer Capability, Capacity Benefit Margin and Transmission Reliability Margin should be calculated in advance. This paper proposes a method to quantify time varying Available Transfer Capability based on probabilistic approach. The uncertainties of power system and market are considered as complex random variables. Total Transfer Capability is determined by optimization technique such as SQP(Sequential Quadratic Programming). Transmission Reliability Margin with the desired probabilistic margin is calculated based on Probabilistic Load Flow analysis, and Capacity Benefit Margin is evaluated using LOLE of the system. Suggested Available Transfer Capability quantification method is verified using IEEE RTS with 72 bus. The proposed method shows efficiency and flexibility for the quantification of Available Transfer Capability.

수질오염총량관리 계획수립의 개선방안에 관한 연구 (A Study on the Improvement Scheme of the Total Water Pollution Load Management Plan)

  • 김영일;이상진
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.977-981
    • /
    • 2006
  • In order to improve water quality in drinking water sources, Ministry of Environment (MOE) was implemented total water pollution load management (TWPLM) in all the major river basins. From the experience of the application of TWPLM, we could find some problems relating the target watershed, standard operating procedure (SOP) of establishment and implementation plan, water quality and flow rate, design flow, water quality model, margin of safety (MOS), and estimation of wasteload were found. The authors were reviewed ongoing TWPLM and presented the improvement schemes for a successful TWPLM. For the application of these suggestions, further detailed studies should be done to implement TWPLM in the future.

우리나라 오염총량관리제도의 적용 및 개선: 2. 안전율 산정 및 삭감부하량 할당 (Improvement and Application of Total Maximum Daily Load Management System of Korea: 2. Determination of Margin of Safety and Allocation of Pollutant Loads)

  • 김경태;정은성;김상욱;이길성
    • 한국물환경학회지
    • /
    • 제26권1호
    • /
    • pp.168-176
    • /
    • 2010
  • This study proposes the improvement of the present Total Maximum Daily Load (TMDL) management system of MOE (Ministry of Environment). The margin of safety (MOS) is calculated by a method using standard error and a method using variability and uncertainty. The allocation of pollutant loads are calculated using three methods, equal load reduction method, equal percent removal method and method using equity standards. This study applied the improved TMDL management system to the Anyangcheon watershed. Since MOS varies from 12% to 44% due to the high variability of measured and simulated data, it must not be ignored in the TMDL. The method using equity standards is the most proper in this application since the others produced unrealistic allocations. Area, runoff, water use quantity, population and budget are considered for equity standards. This study shows that this allocation method can be also applicable for the administrative units as well as the sub-watersheds. Finally, Hydrologic Simulation Program-FORTRAN (HSPF) with the allocated pollutant load was used to confirm whether it satisfy the water quality standard or not. This study will be helpful to improve the MOS and allocation system TMDL in the future.

200kW 급 마이크로 가스터빈의 운전특성 분석 (Analysis of Operating Characteristics of 200kW Class Micro Gas Turbine)

  • 김정호;강도원;김동섭
    • 대한기계학회논문집B
    • /
    • 제37권11호
    • /
    • pp.1015-1022
    • /
    • 2013
  • 본 연구에서는 현재 개발중인 200kW 급 마이크로 가스터빈의 운전 특성을 모사하였다. 세부적인 성능 데이터를 이용하여 부분부하 제어방식(터빈 입구온도 제어방식(constant TIT control)과 터빈 출구온도 제어방식(constant TET control))과 외기온도에 따른 성능 및 작동특성을 분석하였다. 넓은 운전 범위에 대하여 압축기 서지마진과 터빈 입출구 온도 같은 작동 파라미터의 민감도를 단위 연료량 변화에 따라 예측하였다. 정상상태 계산으로 부분부하 변동 시 최대서지마진의 감소에 대한 정보를 민감도 분석을 통해 알 수 있다.

Research on Voltage Stability Boundary under Different Reactive Power Control Mode of DFIG Wind Power Plant

  • Ma, Rui;Qin, Zeyu;Yang, Wencan;Li, Mo
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권6호
    • /
    • pp.1571-1581
    • /
    • 2016
  • A novel method is proposed to construct the voltage stability boundary of power system considering different Reactive Power Control Mode (RPCM) of Doubly-Fed Induction Generator (DFIG) Wind Power Plant (WPP). It can be used for reflecting the static stability status of grid operation with wind power penetration. The analytical derivation work of boundary search method can expound the mechanism and parameters relationship of different WPP RPCMs. In order to improve the load margin and find a practical method to assess the voltage security of power system, the approximate method of constructing voltage stability boundary and the critical points search algorithms under different RPCMs of DFIG WPP are explored, which can provide direct and effective reference data for operators.

확률론적 조류계산을 이용한 송전 신뢰도 여유 계산 (Calculate Transmission Reliability Margin using Probabilistic Load Flow)

  • 신동준;김진오;김규호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.569-571
    • /
    • 2003
  • As a definition of NERC, Available Transfer Capability(ATC) is a measure of the transfer capability remaining in the physical transmission network for the future commercial activity. To calculate ATC, accurate and defensible TTC, CBM and TRM should be calculated in advance. In this paper, we propose a method to quantify TRM using probabilistic load flow based on the method of moment. Generation output, bus voltages, loads, and line outages are considered as complex random variables (CRV) to take into account for uncertainties related to the transmission network conditions. Probability Density Function (PDF) of line flow at the most limiting line is used to quantify TRM with the desired probabilistic margin. Suggested method is compared with the results from conventional CPF method and verified using 24 bus MRTS, and the suggested method based on PLF shows efficiency and flexibility for the quantification of TRM compared with the conventional method.

  • PDF

Flowable 및 microfill 복합레진으로 충전된 제 5급와동에서 load cycling 전,후의 미세변연누출 비교 (MICROLEAKAGE OF MICROFILL AND FLOWABLE COMPOSITE RESINS IN CLASS V CAVITY AFTER LOAD CYCLING)

  • 강석호;김오영;오명환;조병훈;엄정문;권혁춘;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제27권2호
    • /
    • pp.142-149
    • /
    • 2002
  • Low-viscosity composite resins may produce better sealed margins than stiffer compositions (KempScholte and Davidson, 1988: Crim, 1989). Plowable composites have been recommended for use in Class V cavities but it is also controversial because of its high rates of shrinkage. On the other hand, in the study comparing elastic moduli and leakage, the microfill had the least leakage (Rundle et at. 1997) Furthermore, in the 1996 survey of the Reality Editorial Team, microfills were the clear choice for abfraction lesions. The purpose of this study was to evaluate the microleakage of 6 compostite resins (2 hybrids, 2 microfills, and 2 flowable composites) with and without load cycling. Notch-shaped Class V cavities were prepared on buccal surface of 180 extracted human upper premolars on cementum margin. The teeth were randomly divided into non-load cycling group (group 1) and load cycling group (group 2) of 90 teeth each. The experimental teeth of each group were randomly divided into 6 subgroups of 15 samples. All preparations were etched, and Single bond was applied. Preparations were restored with the following materials (n=15) : hybrid composite resin [Z250(3M Dental Products Inc. St. Paul, USA), Denfil(Vericom, Ahnyang, Korea)], microfill [Heliomolar RO(Vivadent, Schaan, Liechtenstein), Micronew(Bisco Inc. Schaumburg, IL, USA)], and flowable composite[AeliteFlo(Bisco Inc. Schaumburg, IL, USA), Revolution(Kerr Corp. Orange, CA, USA)]. Teeth of group 2 were subjected to occlusal load (100N for 50,000 cycles) using chewing simulator(MTS 858 Mini Bionix II system, MTS Systems Corp. Minn. USA). All samples were coated with nail polish 1mm short of the restoration, placed in 2% methylene blue for 24 hours, and sectioned with a diamond wheel. Enamel and dentin/cementum margins were analyzed for microleakage on a sclale of 0 (no leakage) to 3 (3/3 of wall). Results were statistically analyzed by Kruscal-Wallis One way analysis, Mann-Whitney U-test, and Student-Newmann-Keuls method. (p = 0.05) Results : 1. There was significantly less microleage in enamel margins than dentinal margins of all groups (p<0.05) 2. There was no significant between six composite resin in enamel margin of group 1. 3. In dentin margin of group 1, flowable composite had more microleakage than others but not of significant differences. 4. there was no significant difference between six composite resin in enamel margin of group 2. 5. In dentin margin of group 2, the microleakage were R>A =H=M>D>Z. But there was no significant differences. 6. In enamel margins, load cycling did not affect the marginal microleakage in significant degree. 7. In enamel margins, load cycling did affect the marginal microleakage only in Revolution. (p<0.05).