• Title/Summary/Keyword: load levels

Search Result 822, Processing Time 0.022 seconds

An Experimental Study on Accelerated Life Testing for Aluminum Electrolytic Capacitors (알루미늄전해콘덴서의 가속수명시험에 관한 실험연구)

  • Kim, Heung-Jin;Cheon, Ho-Sung;Kim, Seong-Deuk;Park, Young-Taek;Jin, Hong-Gee;Park, Chan-Woong
    • Journal of Korean Society for Quality Management
    • /
    • v.23 no.4
    • /
    • pp.128-147
    • /
    • 1995
  • An accelerated life testing(ALT) for aluminum electrolytic capacitors is conducted and analyzed. A testing equipment, which consists of part fixtures, relay board, controller, video bridge and microcomputer, is made for the ALT. Load factors are temperature with four levels and voltage with three levels. Base on 'optimized 4:2:1 plan', 2,000 electrolytic capacitors are allocated at 12 experimental conditions(; 4 levels of temperature ${\times}3$ levels of voltage), and the ALT is conducted. From the experimental results, an acceleration model is derived and acceleration factors are estimated. A discussion on the experimental results is included.

  • PDF

Effects of auditory feedback and task difficulty on the cognitive load and virtual presence in a virtual reality dental simulation

  • Kim, Byunggee;Yang, Eunbyul;Choi, Namki;Kim, Seonmi;Ryu, Jeeheon
    • The Journal of the Korean dental association
    • /
    • v.58 no.11
    • /
    • pp.670-682
    • /
    • 2020
  • This research examined the difference in cognitive load and the virtual presence depending on auditory feedback and task difficulty in haptic-based dental simulation. In the field of dental education, practice-centered training using handpiece has been crucial because a practitioner's psychomotor experience has a significant impact on the mastery of treatment skills. For the novice, it is necessary to reduce errors in dental treatment to enhancing skill acquisition in the haptic practice. In the training process, the force-feedback is crucial to elaborate subtle movement to guide what to do and how it should be hard or soft. However, It is not easy to add force-feedback to generate kinetic experience training. As an alternative method, we examined that auditory feedback can help learners' skill training. In this study, we analyzed how the presence/absence of auditory feedback at the different levels of task difficulty impacts learners' psychological demand and virtual presence in the virtual reality simulation. For this study, 29 dental college students participated in a dental simulation. The participants were grouped into two conditions that are with and without auditory feedback. Additionally, two consecutive tooth preparation tasks with different levels of difficulty were used in the simulation. The auditory feedback condition gives alarms to a learner when he treats a non-targeted tooth with a virtual handpiece. The user's cognitive load and virtual presence were measured to examine the effects of auditory feedback. The results revealed that the main effect was found in cognitive loads. Also, a significant interaction effect was shown in the virtual presence. We discussed the effective design methods for the virtual reality-based dental simulation through the result of this study.

  • PDF

Study on the In-Plane Vibration Characteristics of the Pneumatic Tires (공기압(空氣壓)타이어의 평면진동특성(平面振動特性)에 관(關)한 연구(硏究))

  • Kim, Nam Joen;Lee, Chong-Ho
    • Journal of Biosystems Engineering
    • /
    • v.12 no.4
    • /
    • pp.9-15
    • /
    • 1987
  • The vibrational characteristics of a radial-ply (155SR13 4PR) and a biased-ply tire (6.15-134PR) were investigated for examining the effects of tires with different structure on the ride characteristics of the vehicle. The natural frequencies at the tread band, mode shapes, and damping factors of two tires at the state of plane vibration were determined experimentally. The test work was performed at four levels of the inflation pressure, ranging from 171.7 kPa to 245.2 kPa, and three levels of the vertical load, deviating by 10% from the standard load designated by the Department of Transportation of the United States of America. The following results were drawn by the analysis of the test results: 1. The first-order natural frequencies of the radial-ply and the biased-ply tires at the tread band were 112 Hz and 159 Hz, respectively, at the state o f the free vibration when the inflation pressure of 196.2 kPa was applied. It was known that the biased-ply tire has higher resonant frequency than the radial-ply tire and the natural frequencies of the both tires move to the high frequency range as t he inflation pressure is increased. 2. The vibration modes of both tires were quite different. No big difference in mode shapes was examined as the inflation pressure was increased. But the natural frequencies of two tires were changed. For the radial-ply tire, no difference in mode shape was found whether the vertical load was applied or not. But a significant difference in mode shape was examined for the biased-ply tire. 3. Any difference was not found in damping factor as the different inflation pressures were applied. 4. When no vertical load was applied, damping factors of the radial-ply and biased-ply tire at the state of the natural vibration ranged from 2.6 to 5.9%, and from 4.1 to 7.8%, respectively. It was estimated that the radial-ply tire would have better cushioning than the biased-ply tire since the vertical spring rate of the radial-ply tire was much less than that of the biased-ply tire, even though the damping effect of the radial-ply tire was smaller than that of the biased-ply tire.

  • PDF

Seismic behavior of reinforced concrete exterior beam-column joints strengthened by ferrocement composites

  • Li, Bo;Lam, Eddie Siu-shu;Wu, Bo;Wang, Ya-yong
    • Earthquakes and Structures
    • /
    • v.9 no.1
    • /
    • pp.233-256
    • /
    • 2015
  • This paper presents an experimental study to assess the effectiveness of using ferrocement to strengthen deficient beam-column joints. Ferrocement is proposed to protect the joint region through replacing concrete cover. Six exterior beam-column joints, including two control specimens and four strengthened specimens, are prepared and tested under constant axial load and quasi-static cyclic loading. Two levels of axial load on column (0.2fc'Ag and 0.4fc'Ag) and two types of skeletal reinforcements in ferrocement (grid reinforcements and diagonal reinforcements) are considered as test variables. Experimental results have indicated that ferrocement as a composite material can enhance the seismic performance of deficient beam-column joints in terms of peak horizontal load, energy dissipation, stiffness and joint shear strength. Shear distortions within the joints are significantly reduced for the strengthened specimens. High axial load (0.4fc'Ag) has a detrimental effect on peak horizontal load for both control and ferrocement-strengthened specimens. Specimens strengthened by ferrocement with two types of skeletal reinforcements perform similarly. Finally, a method is proposed to predict shear strength of beam-column joints strengthened by ferrocement.

COMPARISON OF THE FRICTIONAL RESISTANCE BETWEEN ORTHODONTIC BRACKET & ARCHWIRE (교정용 BRACKET과 ARCHWIRE 사이의 마찰저항에 대한 비교연구)

  • Sung, Hyun Mee;Park, Young Chel
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.543-560
    • /
    • 1991
  • Practitioners are aware of the presence of friction between bracket system and archwire during sliding movement of teeth. Clinically a mesiodistally applied force must exceed the frictional force to produce a tooth movement. The objective of this study were to determine, on a dry condition, changes in magnitude of friction with respect to load, 3rd order inclination (Torque), archwire materials and ligature type. Three wire alloys (Stainless Steel, TMA, NiTi) in two wire sizes (.016, .016x, .022 inch) were examined respect to two bracket system (Straight, Standard), and two ligature type (Metal, Plastic ligature) at three levels of load (100g, 150g, 200g). The results were as follows; 1. Frictional resistance was found to increase with increasing load for S.S., TMA, NiTi. 2. The straight bracket system was exhibited more frictional force than standard bracket system for .016x, .022 S.S. tightly ligated metal ligature. But, torque difference did not increase friction for loose metal ligature & plastic ligature. 3. Regardless of the ligature type, torque and load, stainless steel wire sliding against stainless steel exhibited the lowest friction, and TMA sliding against stainless steel exhibited the highest friction. 4. The loose stainless steel ligature generated lower frictional resistance than plastic ligature in all experimental groups. 5. The following factors affected friction in decreasing order; wire material ligature type, and load.

  • PDF

Further study on improvement on strain concentration in through-diaphragm connection

  • Qin, Ying;Zhang, Jingchen;Shi, Peng;Chen, Yifu;Xu, Yaohan;Shi, Zuozheng
    • Steel and Composite Structures
    • /
    • v.39 no.2
    • /
    • pp.135-148
    • /
    • 2021
  • Hollow structural section (HSS) columns have been increasingly popular due to their structural and architectural merits. However, practical difficulty lies in developing proper connections. The through-diaphragm connections are considered as suitable connection type that is widely adopted in Asian countries. However, the stress concentration occurs at the location connecting through-diaphragm and steel beam. Furthermore, the actual load path from the beam flange is not uniformly transferred to the HSS column as conventionally assumed. In this paper, tensile tests were further conducted on three additional specimens with beam flange plate to evaluate the load versus displacement response. The load-displacement curves, yield and ultimate capacity, ductility ratio were obtained. Furthermore, the strain development at different loading levels was discussed comprehensively. It is shown that the studied connection configuration significantly reduces the stress concentration. Meanwhile, simplified trilinear load-displacement analytical model for specimen under tensile load was presented. Good agreement was found between the theoretical and experimental results.

Seismic collapse safety of high-rise RC moment frames supported on two ground levels

  • Wu, Yun-Tian;Zhou, Qing;Wang, Bin;Yang, Yeong-Bin;Lan, Tian-Qing
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.349-360
    • /
    • 2018
  • Reinforced concrete (RC) moment frames supported on two ground levels have been widely constructed in mountainous areas with medium to high seismicity in China. In order to investigate the seismic collapse behavior and risk, a scaled frame model was tested under constant axial load and reversed cyclic lateral load. Test results show that the failure can be induced by the development of story yielding at the first story above the upper ground. The strong column and weak beam mechanism can be well realized at stories below the upper ground. Numerical analysis model was developed and calibrated with the test results. Three pairs of six case study buildings considering various structural configurations were designed and analyzed, showing similar dynamic characteristics between frames on two ground levels and flat ground of each pair. Incremental dynamic analyses (IDA) were then conducted to obtain the seismic collapse fragility curves and collapse margin ratios of nine analysis cases designated based on the case study buildings, considering amplification of earthquake effect and strengthening measures. Analysis results indicate that the seismic collapse safety is mainly determined by the stories above the upper ground. The most probable collapse mechanism may be induced by the story yielding of the bottom story on the upper ground level. The use of tie beam and column strengthening can effectively enhance the seismic collapse safety of frames on two ground levels.

The Development of an Adjustable Dual-Level Load Limiter (적응형 듀얼레벨 로드리미터 개발)

  • Lee, In-Beom;Kang, Shin-You;Kim, Seock-Hyun;Ryoo, Won-Wha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.10
    • /
    • pp.1187-1191
    • /
    • 2011
  • In this paper, the development of an adjustable load limiter is presented, which is a component of the seat belt. The adjustable load limiter is loaded at different levels for varied weights and heights of occupant. The recent regulation FMVSS 208 demands strict safety standards for different percentiles of dummy size. In this work, high- and low-level load conditions are proposed according to dummy scale and thoracic injury criteria. The suggested load conditions were verified by performing a sled test using the benchmark model. A dual-level load limiter has been developed on the basis of these tests. Experiments were conducted on the product performance, and finite element analysis was carried out; the results confirmed the points for improvement.

Synergic identification of prestress force and moving load on prestressed concrete beam based on virtual distortion method

  • Xiang, Ziru;Chan, Tommy H.T.;Thambiratnam, David P.;Nguyen, Theanh
    • Smart Structures and Systems
    • /
    • v.17 no.6
    • /
    • pp.917-933
    • /
    • 2016
  • In a prestressed concrete bridge, the magnitude of the prestress force (PF) decreases with time. This unexpected loss can cause failure of a bridge which makes prestress force identification (PFI) critical to evaluate bridge safety. However, it has been difficult to identify the PF non-destructively. Although some research has shown the feasibility of vibration based methods in PFI, the requirement of having a determinate exciting force in these methods hinders applications onto in-service bridges. Ideally, it will be efficient if the normal traffic could be treated as an excitation, but the load caused by vehicles is difficult to measure. Hence it prompts the need to investigate whether PF and moving load could be identified together. This paper presents a synergic identification method to determine PF and moving load applied on a simply supported prestressed concrete beam via the dynamic responses caused by this unknown moving load. This method consists of three parts: (i) the PF is transformed into an external pseudo-load localized in each beam element via virtual distortion method (VDM); (ii) then these pseudo-loads are identified simultaneously with the moving load via Duhamel Integral; (iii) the time consuming problem during the inversion of Duhamel Integral is overcome by the load-shape function (LSF). The method is examined against different cases of PFs, vehicle speeds and noise levels by means of simulations. Results show that this method attains a good degree of accuracy and efficiency, as well as robustness to noise.

Accelerated Life Evaluation of Drive Shaft Using Vehicle Load Spectrum Modeling (차량 부하 스펙트럼 모델링을 이용한 구동축의 가속 수명 평가)

  • Kim, Do Sik;Lee, Geun Ho;Kang, E-Sok
    • Transactions of the KSME C: Technology and Education
    • /
    • v.5 no.2
    • /
    • pp.115-126
    • /
    • 2017
  • This paper proposes an accelerated life evaluation of drive shaft for the power train parts of special purpose vehicle. It is necessary the real load data of usage level driving load condition for life evaluation of power train parts, but we can't get the load spectrum data for evaluation in many case of special purpose vehicle. So, in this paper, the road load spectrum data for evaluation is created by modeling and simulation based on vehicle data and special road condition. The inverse power model is used for accelerated life test. The equivalent torque of load spectrum is achieved using the Miner's Rule. This paper also proposes the calibrated acceleration life test method for drive shaft. The fatigue test is performed through three stress levels. The lifetime at normal stress level is predicted by extrapolation, and is verified through comparison of experimental results and load spectrum data.