• Title/Summary/Keyword: load effects

Search Result 3,993, Processing Time 0.031 seconds

Factors to Affect the Growth of Filamentous Periphytic Algae in the Artificial Channels using Treated Wastewater (하수처리수를 이용한 인공수로에서 사상성 부착조류의 성장에 영향을 미치는 요인들)

  • Park, Ku-Sung;Kim, Ho-Sub;Kong, Dong-Soo;Shin, Jae-Ki;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.100-109
    • /
    • 2006
  • This study evaluated the effects of water velocity, substrates, and phosphorus concentrations on the growth of filamentous periphytic algae (FPA) in the two types of artificial channel systems using treated wastewater. Controlled parameters included 5 ${\sim}$ 15 cm $s^{-1}$ for the water velocity; 10 and 20 mm wire meshes, natural fiber net, gravel and tile for the substrates: and 0.05 ${\sim}$ 1.0 mgP $L^{-1}$ for the P concentration. Algal growth rate of FPA was compared using both chi. a and dry weight change with time. Under the controlled water velocity range, the growth of FPA increased with the velocity, but the maximum growth rate was shown in the velocity of 10 cm $s^{-1}$. The substrate that showed the maximum growth of FPA differed between the artificial channel and indoor channel, due to the influence of suspended matters which caused the clogging of the meshed substrates. Under the controled range of P concentration, the growth rates of all three FPA species (Spirogyra turfosa, Oedogonium fovelatum, Rhizoclonium riparium) increased with the P increase, but they showed the differential growth rates among different P concentrations. The results of this study suggest that under the circumstance having an large amount of nutrients FPA develop the biomass rapidly and that even a little increase over the threshold velocity causes the detachment of filamentous periphytic algae. Thus, FPA dynamics in eutrophic streams, such as those receiving treated wastewater, seem to be sensitive to the water velocity. On the other hand, detached algal filaments could deteriorate water quality and ecosystem function in receiving streams or down-stream, and thus they need to be recognized as an important factor in water quality management in eutrophic streams.

Effects of Precombustion Chamber Shape on the Start ability of Small Diesel Engine under the Cold Weather (소형(小型) 디젤엔진의 예연소실(豫燃焼室) 형상(形狀)이 냉시동성(冷始動性)에 미치는 영향(影響)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Moon, Gyeh Song;Kim, Yong Whan;Lee, Seung Kyu
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.9-19
    • /
    • 1982
  • The aim of this study was to improve the startability of the diesel engine at low temperature. The specific objective was to determine the optimum type of precombustion chamber. The eight different types of precombustion chamber and two different types of the cylinder head were designed and tested by $2^7$ factorial experiments with four replications. The lowest starting temperature for first operation, the maximum output, and the specific fuel consumption at full load and overload were checked and analyzed. The results of the study are summarized as follows; 1. The lowest starting temperature was lowered as much as $2.4^{\circ}C$ and the maximum output was increased as much as 0.3 ps with respect to the difference in the relative angle of the main passageway against the piston head from 20 degree to 18 degree. 2. The lowest starting temperature and the maximum out-put were lowered as much as $3.3^{\circ}C$ and 0.3 ps respectively with respect to the difference in the angle of the cylinder head groove from 20 degree to 18 degree. 3. The lowest starting temperature and the maximum out put were lowered as much as $2^{\circ}C$ and 0.2 ps respectively with respect to the difference in the length of the precombustion chamber from 17.5 mm to 15.5mm. 4. There was no significant difference in the startability but the maximum output was increased as much as 0.2 ps with respect to the difference in the diameter of the main passageway from 4.8mm to 4.5mm. 5. The lowest starting temperature was obtained under the condition at 47 degree in the angle of the main passageway and at 18 degree in the angle of the cylinder head groove. The maximum output and the minimum specific fuel consumption was obtained under the condition at 4.5mm in the diameter of the main passageway and at 17.5mm in the length of the precombustion chamber. 6. The angle of the cylinder head groove and the main passageway appeared to the major factors affecting the startability significantly. The interaction between the diameter of the main pass ageway and the length of the precombustion chamber had an significant influence on the maximum output. So it would be recommended to study further on the interaction between two factors mentioned above by expanding their levels. 7. The optimum condition suggested by this study could lower the starting temperature by $6^{\circ}C$ compared to the conventional precombustion chambers.

  • PDF

Voluntary stand-up physical activity enhances endurance exercise capacity in rats

  • Seo, Dae Yun;Lee, Sung Ryul;Kwak, Hyo-Bum;Seo, Kyo Won;McGregor, Robin A;Yeo, Ji Young;Ko, Tae Hee;Bolorerdene, Saranhuu;Kim, Nari;Ko, Kyung Soo;Rhee, Byoung Doo;Han, Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.3
    • /
    • pp.287-295
    • /
    • 2016
  • Involuntary physical activity induced by the avoidance of electrical shock leads to improved endurance exercise capacity in animals. However, it remains unknown whether voluntary stand-up physical activity (SPA) without forced simulating factors improves endurance exercise capacity in animals. We examined the effects of SPA on body weight, cardiac function, and endurance exercise capacity for 12 weeks. Twelve male Sprague-Dawley rats (aged 8 weeks, n=6 per group) were randomly assigned to a control group (CON) or a voluntary SPA group. The rats were induced to perform voluntary SPA (lifting a load equal to their body weight), while the food height (18.0 cm) in cages was increased progressively by 3.5 every 4 weeks until it reached 28.5 cm for 12 weeks. The SPA group showed a lower body weight compared to the CON group, but voluntary SPA did not affect the skeletal muscle and heart weights, food intake, and echocardiography results. Although the SPA group showed higher grip strength, running time, and distance compared to the CON group, the level of irisin, corticosterone, genetic expression of mitochondrial biogenesis, and nuclei numbers were not affected. These findings show that voluntary SPA without any forced stimuli in rats can effectively reduce body weight and enhance endurance exercise capacity, suggesting that it may be an important alternative strategy to enhance endurance exercise capacity.

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

An Estimate of Ballast Track Condition on Dynamic Behavior of Railway Bridge (철도교량의 동적거동 특성을 고려한 자갈도상궤도의 상태추정에 관한 연구)

  • Kweon, Oh-Soon;Choi, Jung-Youl;Kang, Myoung-Seok;Lee, Hee-Up;Park, Yong-Gul
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.480-493
    • /
    • 2007
  • Many railway-advanced countries are using the various types of track to reduce the track maintenance and repair cost according to the improvement of velocity. It spends on much maintenance and repair cost for ballast track due to abrasion of ballast, track irregularity and unisotropical ballast-support stiffness. The ballast track on railway bridge is accelerating the deterioration of ballast according to interaction of railway bridge and track. As continuing the deterioration, it is caused dynamic loads. Due to these effects, it increases negative loads of track and bridge. However, when designing the railway bridge, the effect of ballast track was applicate only dead load, so elastic behavior effect of ballast track is not influenced. Therefore, this paper presumes the stiffness of ballast track on railway bridge considering dynamic behavior of railway bridge, it was evaluated that effect on dynamic behaviors of railway bridge according to ballast track stiffness.

  • PDF

Effect of Supercritical Carbon Dioxide on Physicochemical Properties and Microbial Reduction of Freeze-Dried Bovine Liver (초임계 이산화탄소 처리가 동결 건조된 소간의 이화학적 특성 및 미생물 저감화에 미치는 영향)

  • Kim, Hye-Min;Woo, Sung-Woon;Kim, Ah-Na;Heo, Ho-Jin;Chun, Ji-Yeon;Choi, Sung-Gil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.12
    • /
    • pp.1847-1855
    • /
    • 2015
  • Supercritical carbon dioxide ($SC-CO_2$) treatment has been becoming an important method for substituting the use of organic solvents for samples extraction prior to analysis due to its low toxicity, ease of handling, low cost of disposal etc. Freeze-dried bovine liver was treated with $SC-CO_2$ under different pressures (200, 300, and 450 bar) in order to investigate effects on physicochemical properties and reduction of microbial load. The yield of lipid extraction from bovine liver by $SC-CO_2$ treatment increased with increasing pressure, with values of 84, 86, and 90% in response to 200, 300, and 450 bar, respectively. Results of high performance liquid chromatography analysis showed that vitamin A and coenzyme $Q_{10}$ ($CoQ_{10}$), which is soluble in lipid, were almost removed from bovine liver by $SC-CO_2$ treatment. Saturated fatty acids ratio of bovine liver decreased with increasing pressure, whereas polyunsaturated fatty acids increased with increasing pressure. Total content of amino acids in bovine liver treated by $SC-CO_2$ was less than that of the control sample without treatment. The number of aerobic bacteria in bovine liver, which was stored at $5^{\circ}C$ for 5 days and freeze-dried, decreased from 6.2 to 4.2 log CFU/g by $SC-CO_2$ treatment at 100 bar for 3 h. Interestingly, coliform bacteria were not found in the bovine liver sample by $SC-CO_2$ at 100 bar for 3 h under all storage conditions. This indicates that $SC-CO_2$ treatment can effectively reduce coliform bacteria in the food matrix even at low moisture. In conclusion, freeze-dried bovine liver by proper $SC-CO_2$ treatment may be used as a potential high protein source, with increasing microbial safety and stability of lipid oxidation.

Channel Changes and Effect of Flow Pulses on Hydraulic Geometry Downstream of the Hapcheon Dam (합천댐 하류 하천지형 변화 예측 및 흐름파가 수리기하 변화에 미치는 영향)

  • Shin, Young-Ho;Julien, Pierre Y.
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.7
    • /
    • pp.579-589
    • /
    • 2009
  • Hwang River in South Korea, has experienced channel adjustments due to dam construction. Hapcheon main dam and re-regulation dam. The reach below the re-regulation dam (45 km long) changed in flow regime, channel width, bed material distribution, vegetation expansion, and island formation after dam construction. The re-regulation dam dramatically reduced annual peak flow from 654.7 $m^3$/s to 126.3 $m^3$/s and trapped the annual 591 thousand $m^3$ of sediment load formerly delivered from the upper watershed since the completion of the dam in 1989. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that non-vegetated active channel width narrowed an average of 152 m (47% of 1982) and non-vegetated active channel area decreased an average of 6.6 km2 (44% of 1982) between 1982 and 2004, with most narrowing and decreasing occurring after dam construction. The effects of daily pulses of water from peak hydropower generation and sudden sluice gate operations are investigated downstream of Hapcheon Dam in South Korea. The study reach is 45 km long from the Hapcheon re-regulation Dam to the confluence with the Nakdong River. An analysis of a time series of aerial photographs taken in 1982, 1993, and 2004 showed that the non-vegetated active channel width narrowed an average of 152 m (47% reduction since 1982). The non-vegetated active channel area also decreased an average of 6.6 $km^2$ (44% reduction since 1982) between 1982 and 2004, with most changes occurring after dam construction. The average median bed material size increased from 1.07 mm in 1983 to 5.72 mm in 2003, and the bed slope of the reach decreased from 0.000943 in 1983 to 0.000847 in 2003. The riverbed vertical degradation is approximately 2.6 m for a distance of 20 km below the re-regulation dam. It is expected from the result of the unsteady sediment transport numerical model (GSTAR-1D) steady simulations that the thalweg elevation will reach a stable condition around 2020. The model also confirms the theoretical prediction that sediment transport rates from daily pulses and flood peaks are 21 % and 15 % higher than their respective averages.

Prediction of Concrete Temperature and Its Effects on Continuously Reinforcement Concrete Pavement Behavior at Early Ages (초기재령에서 연속철근콘크리트포장 거동에 콘크리트 온도의 영향과 예측)

  • Kim Dong-Ho;Choi Seong-Cheol;Won Moon-Cheol
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.55-62
    • /
    • 2006
  • Transverse cracks in continuously reinforced concrete pavement (CRCP) occur at early ages due to temperature and moisture variations. The width and spacing of transverse cracks have a significant effect on pavement performance such as load transfer efficiency and punchout development. Also, crack widths in CRCP depend on 'zero-stress temperature,' which is defined as a temperature where initial concrete stresses become zero, as well as drying shrinkage of concrete. For good long-term performance of CRCP, transverse cracks need to be kept tight. To keep the crack widths tight throughout the pavement life, zero-stress temperature must be as low as practically possible. Thus, temperature control at early ages is a key component In ensuring good CRCP performance. In this study, concrete temperatures were predicted using PavePro, a concrete temperature prediction program, for a CRCP construction project, and those values were compared with actual measured temperatures obtained from field testing. The cracks were also surveyed for 12 days after concrete placement. Findings from this study can be summarized as follows. First, the actual maximum temperatures are greater than the predicted maximum temperature in the ranges of 0.2 to 4.5$^{\circ}C$. For accurate temperature predictions, hydration properties of cementitious materials such as activation energy and adiabatic constants, should be evaluated and accurate values be obtained for use as input values. Second, within 24 hours of concrete placement, temperatures of concrete placed in the morning are higher than those placed in the afternoon, and the maximum concrete temperature occurred in the concrete placed at noon. Finally, from the 12 days of condition survey, it was noted that the rate of crack occurrence in the morning placed section was 25 percent greater than that in the afternoon placed section. Based on these findings, it is concluded that maximum concrete temperature has a significant effect on crack development, and boner concrete temperature control is needed to ensure adequate CRCP performance.

  • PDF

The effects of short-term application of calcium hydroxide on dentin fracture strength (단기간의 수산화 칼슘 적용이 상아질 파절강도에 미치는 영향)

  • Shin, Eun-Jung;Park, Yeong-Joon;Lee, Bin-Na;Jang, Ji-Hyun;Chang, Hoon-Sang;Hwang, In-Nam;Oh, Won-Mann;Hwang, Yun-Chan
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.425-430
    • /
    • 2011
  • Objectives: This in vitro study investigated whether short-term application of calcium hydroxide in the root canal system for 1 and 4 wk affects the fracture strength of human permanent teeth. Materials and Methods: Thirty two mature human single rooted mandibular premolars in similar size and dentin thickness without decay or restorations were hand and rotary instrumented and 16 teeth vertically packed with calcium hydroxide paste and sealed coronally with caviton to imitate the endodontic procedure and the other 16 teeth was left empty as a control group. The apicies of all the samples were sealed with resin, submerged in normal saline and put in a storage box at $37^{\circ}C$ to mimic the oral environment. After 1 and 4 wk, 8 samples out of 16 samples from each group were removed from the storage box and fracture strength test was performed. The maximum load required to fracture the samples was recorded and data were analysed statistically by the two way ANOVA test at 5% significance level. Results: The mean fracture strengths of two groups after 1 wk and 4 wk were similar. The intracanal placement of calcium hydroxide weakened the fracture strength of teeth by 8.2% after 4 wk: an average of 39.23 MPa for no treatment group and 36.01 MPa for CH group. However there was no statistically significant difference between experimental groups and between time intervals. Conclusions: These results suggest that short term calcium hydroxide application is available during endodontic treatment.