• Title/Summary/Keyword: load allocation

Search Result 265, Processing Time 0.026 seconds

Broadcasting Message Reduction Methods in VANET

  • Makhmadiyarov, Davron;Hur, Soojung;Park, Yongwan
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.4 no.1
    • /
    • pp.42-49
    • /
    • 2009
  • Most Vehicular Ad hoc Network (VANET) applications rely heavily on broadcast transmission of traffic related information to all reachable nodes within a certain geographical area. Among various broadcast approaches, flooding is the first broadcasting technique. Each node rebroadcasts the received message exactly once, which results in broadcast storm problems. Some mechanisms have been proposed to improve flooding in Mobile Ad hoc Networks (MANET), but they are not effective for VANET and only a few studies have addressed this issue. We propose two distance-based and timer-based broadcast suppression techniques: 15P(15percent) and slotted 15P. In the first (distance based) scheme, node's transmission range is divided into three ranges (80%,15%and5%). Only nodes within 15% range will rebroadcast received packet. Specific packet retransmission range (15%) is introduced to reduce the number of messages reforwarding nodes that will mitigate the broadcaststorm. In the second (timer-based) scheme, waiting time allocation for nodes within 15% range isused to significantly reduce the broadcaststorm. The proposed schemes are distributed and reliedon GPS information and do not requireany other prior knowledge about network topology. To analyze the performance of proposed schemes, statistics such as link load and the number of retransmitted nodes are presented. Our simulation results show that the proposed schemes can significantly reduce link load at high node densities up to 90 percent compared to a simple broadcast flooding technique.

  • PDF

An Efficient Load Balancing Technique in a Multicore Mobile System (멀티코어 모바일 시스템에서 효과적인 부하 균등화 기법)

  • Cho, Jungseok;Cho, Doosan
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.5
    • /
    • pp.153-160
    • /
    • 2015
  • The effectiveness of multicores depends on how well a scheduler can assign tasks onto the cores efficiently. In a heterogeneous multicore platform, the execution time of an application depends on which core it executes on. That is to say, the effectiveness of task assignment is one of the important components for a multicore systems' performance. This work proposes a load scheduling technique that analyzes execution time of each task by profiling. The profiling result provides a basic information to predict which task-to-core mapping is likely to provide the best performance. By using such information, the proposed technique is about 26% performance gain.

TMDL Evaluation of Nakdong River Basin Using Load Duration Curve and Streamflow-Load Rating Curve (부하지속곡선과 유량-부하량 상관곡선을 이용한 낙동강 유역의 오염총량평가)

  • Shon, Tae Seok;Joo, Jae Seung;Park, Jae Beom;Shin, Hyun Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5B
    • /
    • pp.475-481
    • /
    • 2011
  • The TMDL standard flow as applying watershed management regime uses the average low flow of past 10 years. Moreover, the TMDL implementation assessment has been enforced through management of pollutant load satisfied objective water quality. Even though the present allocation and management through averaged low flow are still convenient, they are not enough to solve ultimate goals of watershed management to keep up recovery of water body. To maintain the same water quality concentration, the standard flow is required to consider total discharge in management plan which helps to keep healthy ecosystem. In view of this, it would be possible to approach reasonable assessment by reflecting variably changeable discharge from precipitation-streamflow relation and the TMDL standard establishment considering artificial regulated flow. Therefore, this study attempts to develop the TMDL method using Load Duration Curve (LDC) and Streamflow-Load Rating Curve (QLRC) considering total discharge and finds drawbacks with solutions as applying on Nakdong river TMDL unit watershed. Finally, this research evaluates possibility of application on pollutant load allocating and implementation assessment in Korea.

Cost Reduction Measure for River Water Quality Management by Cooperation between Local Governments:a Case of the Youngsan River (지자체간 협조를 통한 하천수질관리 비용절감 방안: 영산강을 대상으로)

  • Yeo, Kyu Dong;Jo, Eun Hui;Jung, Young Hun;Yi, Choong Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5B
    • /
    • pp.273-285
    • /
    • 2012
  • Current TMDL based on the 'Polluter Pays Principle' in Republic of Korea is individually operated by each local government for the designed allocated pollution load of unit watershed and unit district. However, unlike the motion of the air contaminants, the polluted contaminants in a river move from upstream to downstream, and a river can affect to districts more than two. In addition, a decision making on the construction of a sewage treatment facilities follows the concept of 'economy of scale'. These reasons support the collaboration among local governments in order to reduce the costs in improving water quality. This study suggested a method to reduce water quality management cost by redistributing reduction load considering cost-effectiveness for an entire watershed. The assessment on the suggested method is conducted in Youngsan river watershed. Without variation in total load, reduction load assigned for unit watershed and unit district is retributed in the region where pollutant source is concentrated, and then water quality and cost reduction improved from the redistribution of reduction load is analyzed. The results show that the cost saved by the suggested method is KRW 124 billion for scenario-1 and 172 billion for scenario-2 considering total cost of KRW 788 billion for the existing plan. We expect that the suggested method is a good example to reduce water quality management cost in local governments for TMDL.

Energy-aware Virtual Resource Mapping Algorithm in Wireless Data Center

  • Luo, Juan;Fu, Shan;Wu, Di
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.3
    • /
    • pp.819-837
    • /
    • 2014
  • Data centers, which implement cloud service, have been faced up with quick growth of energy consumption and low efficiency of energy. 60GHz wireless communication technology, as a new option to data centers, can provide feasible approach to alleviate the problems. Aiming at energy optimization in 60GHz wireless data centers (WDCs), we investigate virtualization technology to assign virtual resources to minimum number of servers, and turn off other servers or adjust them to the state of low power. By comprehensive analysis of wireless data centers, we model virtual network and physical network in WDCs firstly, and propose Virtual Resource Mapping Packing Algorithm (VRMPA) to solve energy management problems. According to VRMPA, we adopt packing algorithm and sort physical resource only once, which improves efficiency of virtual resource allocation. Simulation results show that, under the condition of guaranteeing network load, VPMPA algorithm can achieve better virtual request acceptance rate and higher utilization rate of energy consumption.

Adaptive algorithm for optimal real-time pricing in cognitive radio enabled smart grid network

  • Das, Deepa;Rout, Deepak Kumar
    • ETRI Journal
    • /
    • v.42 no.4
    • /
    • pp.585-595
    • /
    • 2020
  • Integration of multiple communication technologies in a smart grid (SG) enables employing cognitive radio (CR) technology for improving reliability and security with low latency by adaptively and effectively allocating spectral resources. The versatile features of the CR enable the smart meter to select either the unlicensed or the licensed band for transmitting data to the utility company, thus reducing communication outage. Demand response management is regarded as the control unit of the SG that balances the load by regulating the real-time price that benefits both the utility company and consumers. In this study, joint allocation of the transmission power to the smart meter and consumer's demand is formulated as a two stage multi-armed bandit game in which the players select their optimal strategies noncooperatively without having any prior information about the media. Furthermore, based on historical rewards of the player, a real-time pricing adaptation method is proposed. The latter is validated through numerical results.

Design of a High-Level Synthesis System for Automatic Generation of Pipelined Datapath (파이프라인 데이터패스 자동 생성을 위한 상위수준 합성 시스템의 설계)

  • 이해동;황선영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.3
    • /
    • pp.53-67
    • /
    • 1994
  • This paper describes the design of a high-level synthesis system. SODAS-VP. which automatically generates hardwares executing operation sequences in pipelined fashion.Target architecture and clocking schemes to drive pipelined datapath are determined, and the handling of pipeline hazards which degrade the performance of pipeline is considered. Partitioning of an operation into load, operation, and store stages, each of which is executed in partitiones control step, is performend. Pipelinecl hardware is generated by handling pipeline hazards with internal forwarding or delay insertion techniques in partitioning process and resolving resource conflicts among the partitioned control steps with similarity measure as a priority function in module allocation process. Experimental results show that SODAS-VP generates hardwares that execute faster than those generated by HAL and ALPS systems. SODAS-VP brings improvement in execution speed by 17.1% and 7.4% comparing with HAL and ALPS systems for a MCNC benchmark program, 5th order elliptical wave filter,respectively.

  • PDF

Analytical Approach for Optimal Allocation of Distributed Generators to Minimize Losses

  • Kaur, Navdeep;Jain, Sanjay Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1582-1589
    • /
    • 2016
  • In this paper the integration of Distributed Generation (DG) in radial distribution system is investigated by computing the optimal site and size of DG to be placed. An analytical expression based on equivalent current injection has been derived by utilizing topological structure of radial distribution system to find optimal size of DG to minimize losses. In the presented formulation, the optimal DG placement is obtained without repeatedly computing the load flow. The proposed formulation can be used to find the optimal size of all types of DGs namely Type-I, Type-II, Type-III and Type-IV DGs. The investigations are carried out on IEEE 33-bus and 69-bus radial distribution systems. The optimal DG placement results into reduction in active and reactive power losses and improvement in voltage profile of the buses.

Development of Full Coverage Test Framework for NVMe Based Storage

  • Park, Jung Kyu;Kim, Jaeho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.4
    • /
    • pp.17-24
    • /
    • 2017
  • In this paper, we propose an efficient dynamic workload balancing strategy which improves the performance of high-performance computing system. The key idea of this dynamic workload balancing strategy is to minimize execution time of each job and to maximize the system throughput by effectively using system resource such as CPU, memory. Also, this strategy dynamically allocates job by considering demanded memory size of executing job and workload status of each node. If an overload node occurs due to allocated job, the proposed scheme migrates job, executing in overload nodes, to another free nodes and reduces the waiting time and execution time of job by balancing workload of each node. Through simulation, we show that the proposed dynamic workload balancing strategy based on CPU, memory improves the performance of high-performance computing system compared to previous strategies.

Avoided Generation Costs of IPPS Considering Forced Outage Rate and Economic Loading Order (고장정지율과 경제적 투입순서를 고려한 민자발전소의 회피발전비용 계산)

  • 원종률;박종배;김진호
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.47-58
    • /
    • 2002
  • This paper presents a new method for the evaluation of avoided generation costs. Unlike conventional load decrement method, it exactly considers forced outage rate and economic loading order of IPPs (Independent Power Producers). Therefore we can provide exact generation avoided costs of IPPs by the developed method. Because probabilistic simulation is conducted in this method, effects on the costs of IPPs are exactly considered. Also we suggest an allocation method of avoided generation costs by participation factor. In the case studies we have shown avoided generation costs considering loading order and forced out-age rate by using this method.