• Title/Summary/Keyword: load Q

Search Result 373, Processing Time 0.026 seconds

부하가변시 3상 PWM 컨버터의 전류제어에 관한 연구 (Current Control of Three Phase PWM Converter for the Variable Load)

  • 이재훈;김은기;전기영;전지용;이승환;오봉환;이훈구;한경희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.441-443
    • /
    • 2007
  • In this paper, The authors design the current controller which independently control the d, q axis current transformed by the synchronously rotating d, q axis and a Space Vector Pulse Width Modulation(SVPWM) to steadily control the output DC-Link voltage against the variable load of the three phase PWM converter. Also, This study improves the high power factor, stability, and rapid response by the phase angle control using the digital Phase Locked Loop(PLL).

  • PDF

Effect of Shifting the Pole-shoe and Damper-bar Centerlines on the No-load Voltage Waveform of a Tubular Hydro-generator

  • Fan, Zhen-nan;Han, Li;Liao, Yong;Xie, Li-dan;Wen, Kun;Wang, Jun;Dong, Xiu-cheng;Yao, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1294-1303
    • /
    • 2018
  • This study optimises the no-load voltage waveform of tubular hydro-generators by a simple design scheme. For different centerlines of the pole shoe and damper bar, the optimisation effects on the no-load voltage waveform are investigated in two tubular hydro-generators with different weighted powers (34 MW and 18 MW). The results are compared with those of the traditional stator-slots skewed design. The quality of the no-load voltage waveform was related to the shifting degree, and the different optimisation effects between the integer slot generator (q = 2) and the fractional slot generator (q = 11/2) were analysed. This research can improve the quality of the power output and no-load voltage waveform, and provide an effective reference for improving the industrial design and manufacture level of tubular hydro-generators.

등가변형을 이용한 테이터 말뚝의 지지력 산정 (Estimation of Axial toad Capacity for Tapered Piles Using Equivalent Transformation)

  • 전성남;서경범;송원준;이준환
    • 한국지반공학회논문집
    • /
    • 제25권8호
    • /
    • pp.57-64
    • /
    • 2009
  • 본 연구에서는 등가변형을 이용하며 테이퍼 말뚝의 지지력을 산정하는 방법을 제안하였다. 지반조건과 테이퍼각도를 고려하여 지지력을 산정하던 기존의 방법과 달리, 테이퍼말뚝의 지지력산정시 콘관입시험 결과를 활용하도록 하였다. 이때 테이퍼말뚝은 등가변형을 이용하여 형태를 단순화 시켰으며 이를 통해 실무에서 비교적 쉽게 지지력을 산정 할 수 있는 방법을 제안하였다. 제안된 방법의 검증을 위해 실내시험과 현장시험을 실시하였다. 실내모형시험 결과로부터 측정된 극한지지력과 본 연구에서 제안된 방법에 의한 예측값을 비교한 결과 표준편차는 $0.05{\sim}0.121$, COV는 $0.04{\sim}0.05$의 값을 보여 대체적으로 유사한 결과를 보였으며, 현장시험은 약 2.5%의 오차를 보여 측정값에 근접함을 알 수 있었다. 그 결과 제안된 지지력 산정법은 테이퍼말뚝의 지지력을 비교적 정확하게 예측하는 것으로 나타났다.

A Numerical Investigation on Restrained High Strength Q460 Steel Beams Including Creep Effect

  • Wang, Weiyong;Zhang, Linbo;He, Pingzhao
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1497-1507
    • /
    • 2018
  • Most of previous studies on fire resistance of restrained steel beams neglected creep effect due to lack of suitable creep model. This paper presents a finite element model (FEM) for accessing the fire resistance of restrained high strength Q460 steel beams by taking high temperature Norton creep model of steel into consideration. The validation of the established model is verified by comparing the axial force and deflection of restrained beams obtained by finite element analysis with test results. In order to explore the creep effect on fire response of restrained Q460 steel beams, the thermal axial force and deflection of the beams are also analyzed excluding creep effect. Results from comparison infer that creep plays a crucial role in fire response of restrained steel beam and neglecting the effect of creep may lead to unsafe design. A set of parametric studies are accomplished by using the calibrated FEM to evaluate the governed factors influencing fire response of restrained Q460 steel beams. The parametric studies indicate that load level, rotational restraint stiffness, span-depth ratio, heating rate and temperature distribution pattern are key factors in determining fire resistance of restrained Q460 steel beam. A simplified design approach to determine the moment capacity of restrained Q460 steel beams is proposed based on the parametric studies by considering creep effect.

결합계수 해석에 의한 유도가열용 인버터의 공진회로 설계법 (A Resonant Circuit Design of the Inverter for Induction Heating by Analysis of the Coupling Coefficient)

  • 이광직;김주홍
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권6호
    • /
    • pp.90-95
    • /
    • 1997
  • 고주파 유도가열을 위한 인버터의 공진회로 설계에서 인덕턴스 L의 작용과, 출력전달 요소로 사용된 변압기의 결합계수, 그리고 코일을 사용한 가열부하의 결합계수가 공진회로의 출력, 회로의 Q와 공진주파수에 큰 영향을 주고 있음을 등가회로를 도출하여 그 특성을 해석하였다. 또한 변압기를 테브난 등가회로로 구성할 경우, 변압기의 이차측 임피던스를 일차측 임피던스고 환산하면, 권선비 n$^2$에 비례 할 뿐만 아니라 결합계수 $K^2$에도 비례함을 도출하여 결합계수형 테브난 등가회로에 의한 정확성이 큰 인버터 공진회로 설계의 기초방식을 나타냈다.

  • PDF

강우시 채수빈도가 논 오염부하량 산정에 미치는 영향 (Effect of Sampling Frequency During Storm Period on Estimation of Pollutant Load from Paddy Field)

  • 한국헌;김진호;이종식;이정택;조재영;윤광식
    • 한국환경농학회지
    • /
    • 제24권1호
    • /
    • pp.17-23
    • /
    • 2005
  • 한정된 수질자료를 이용 오염부하 산정시 집중적으로 많은 샘플을 채취한 경우에 비해 어느 정도 차이를 갖는지를 규명하는 것은 모니터링에 따른 오염부하량 산정결과의 신뢰범위 파악뿐만 아니라 경제적인 수질 샘플 채수빈도 수립에 곡 필요할 것으로 사료된다. 그 결과를 요약하면 다음과 같다. 논에서의 강-은유출시 채수 빈도가 오염부하 산정에 미치는 영향을 파악하기 위해 9개의 강우사상에 대해 2시간 간격으로 연속 수질샘플을 실시하여 분석한 결과 전체적으로 강우-유출과정 중 T-N, T-P, SS 농도는 시간별로 증 감변동을 하였으나 유량과의 상관성은 나타나지 않았다. 수질샘플 횟수에 의한 영향은 강우-유출과정 중 5회 정도 샘플을 실시하면 많은 수의 샘플을 채수한 경우에 비해 T-N ${\pm}15.2%$, T-P는 $-20.0{\sim}26.2%$, SS는 $-28.6{\sim}35.7%$ 범위안에서 오염부하를 추정할 수 있는 것으로 나타났으며, 차이범위가 ${\pm}10%$ 내에 들어가기 위한 샘플수는 일주기 조사시 T-N, T-P의 경우는 6회, SS의 경우는 단기유출시는 4회 정도 실시하면 되고, 장기 유출시에는 11회 정도 실시하면 되는 것으로 조사되었다. 유량-유하부하량 관계식에서 ${\pm}10%$내의 차이를 보일 샘플횟수는 T-N의 경우는 6회 이상, T-P와 SS는 9회 이상 정도 실시하면 되는 것으로 조사되었다.

撒水濾床法에 依한 畜産廢水의 處理效果에 관한 연구 (Efficiency of Livestock Farming Wastewater Treatment by Trickling Filters)

  • Ahu, Soo Mi
    • 한국환경보건학회지
    • /
    • 제11권2호
    • /
    • pp.17-27
    • /
    • 1985
  • The objectives of this study is to examine efficiency of swinery wastewater treatment by trickling filters' pilot plant. The results of this study are as follows: 1. The characteristics of sample. The BOD$_5$ was from 2,450 to 2,880mg/l, COD(KMnO$_4$ acid method) was from 910 to 1,064mg/l, and SS was from 920 to 990mg/l. The pH of influent was from 7.3 to 7.6, and the temperature of water was from 17.0$\circ$C to 22.5$\circ$C. 2. For experiment by recirculation, the BODs removal efficiency is 65.2% at recirculation ratio (r)=0, and 70.7% at r=1. The ramoval efficiency of this study is higher than NRC formula of U.S.A.. The recirculation is not significant effect on removal efficiency. 3. For experiment by hydraulic load, the BOD$_5$ removal rate decreased from 73.1% at $3.1m^3/m^2\cdot d$ to 65.3% at $9.2m^3/m^2\cdot d$. The design formula of this study which shows the removal rate of soluble BOD is $Le/Li =10^{-0.24} D/Q^{0.24}$ (Q: hydraulic load, D: depth of filter). 4. For experiment by organic load, the BOD$_5$ removal rate is increased from 70.2% at $0.77kg/m^3\cdot d$ to 75.4% at $4.28kg/m^3\cdot d$. We can obtain the straight line y=0.749 x (y: removed BOD, x :applied BOD) by the least squares method. 5. We can know that trickling filters is strong with the hydraulic load and the organic matter shock load. Here, we can judge that trickling filters is a good method for the treatment of swinery wastewater which containing high concentrated organic matter.

  • PDF

Nonlinear analysis of interaction between flexible pile group and soil

  • Liu, Jie;Li, Q.S.;Wu, Zhe
    • Structural Engineering and Mechanics
    • /
    • 제20권5호
    • /
    • pp.575-587
    • /
    • 2005
  • Using the nonlinear load transfer function for pile side soil and the linear load transfer function for pile end soil, a combined approach of the incremental load transfer matrix method and the approximate differential equation solution method is presented for the nonlinear analysis of interaction between flexible pile group and soil. The proposed method provides an effective approach for the solution of the nonlinear interaction between flexible pile group under rigid platform and surrounding soil. To verify the accuracy of the proposed method, a static load test for a nine-pile group under a rigid platform is carried out. The finite element analysis is also conducted for comparison purposes. It is found that the results from the proposed method match very well with those from the experimental test and are better in comparison with the finite element method.

표준 공수 설정에 관한 연구 -K자동차 회사의 사례를 중심으로- (A Study on the Determination of the Standard Time and Load)

  • 이원근
    • 산업경영시스템학회지
    • /
    • 제5권7호
    • /
    • pp.59-62
    • /
    • 1982
  • The purpose of this paper is to increase the effectiveness of decreasing time - load and cost down in manufacturing company using the new way of regulating standard time - load. Let us take an example of K automobile factory. This company have avoided the used to way of regulating standard ti me load in staff members and increased the effectiveness of decreasing time - load having participated all members centering around the Q.C circle. Here, We can take conclusions as below. 1. We could improve the consciousness of question and the consciousness of efficiency progress as a result of new way. 2. We could encourage the activation of organization and working desire of all members to be participated.

  • PDF

Designing of the Beheshtabad water transmission tunnel based on the hybrid empirical method

  • Mohammad Rezaei;Hazhar Habibi
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.621-633
    • /
    • 2023
  • Stability analysis and support system estimation of the Beheshtabad water transmission tunnel is investigated in this research. A combination approach based on the rock mass rating (RMR) and rock mass quality index (Q) is used for this purpose. In the first step, 40 datasets related to the petrological, structural, hydrological, physical, and mechanical properties of tunnel host rocks are measured in the field and laboratory. Then, RMR, Q, and height of influenced zone above the tunnel roof are computed and sorted into five general groups to analyze the tunnel stability and determine its support system. Accordingly, tunnel stand-up time, rock load, and required support system are estimated for five sorted rock groups. In addition, various empirical relations between RMR and Q i.e., linear, exponential, logarithmic, and power functions are developed using the analysis of variance (ANOVA). Based on the significance level (sig.), determination coefficient (R2) and Fisher-test (F) indices, power and logarithmic equations are proposed as the optimum relations between RMR and Q. To validate the proposed relations, their results are compared with the results of previous similar equations by using the variance account for (VAF), root mean square error (RMSE), mean absolute percentage error (MAPE) and mean absolute error (MAE) indices. Comparison results showed that the accuracy of proposed RMR-Q relations is better than the previous similar relations and their outputs are more consistent with actual data. Therefore, they can be practically utilized in designing the tunneling projects with an acceptable level of accuracy and reliability.