• 제목/요약/키워드: load - reducing

검색결과 1,087건 처리시간 0.024초

Impact of bonding defect on the tensile response of a composite patch-repaired structure: Effect of the defect position and size

  • N., Kaddouri;K., Madani;S.CH., Djebbar;M., Belhouari;R.D.S.G., Campliho
    • Structural Engineering and Mechanics
    • /
    • 제84권6호
    • /
    • pp.799-811
    • /
    • 2022
  • Adhesive bonding has seen rapid development in recent years, with emphasis to composite patch repairing processes of geometric defects in aeronautical structures. However, its use is still limited given its low resistance to climatic conditions and requirement of specialized labor to avoid fabrication induced defects, such as air bubbles, cracks, and cavities. This work aims to numerically analyze, by the finite element method, the failure behavior of a damaged plate, in the form of a bonding defect, and repaired by an adhesively bonded composite patch. The position and size of the defect were studied. The results of the numerical analysis clearly showed that the position of the defect in the adhesive layer has a large effect on the value of J-Integral. The reduction in the value of J-Integral is also related to the composite stacking sequence which, according to the mechanical properties of the ply, provides better load transfer from the plate to the repair piece through the adhesive. In addition, the increase in the applied load significantly affects the value of the J-Integral at the crack tip in the presence of a bonding defect, even for small dimensions, by reducing the load transfer.

그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구 (Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling)

  • 김웅회;강은호;윤종호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

손등 정맥 패턴을 이용한 개인식별 알고리즘의 회전 보상에 관한 연구 (A Study on A Rotation Compensation of Person Identification Algorithm Utilizing Hand Vein Pattern)

  • 안장용;주일용;최환수
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 추계종합학술대회 논문집(4)
    • /
    • pp.251-254
    • /
    • 2000
  • This paper proposes an enhanced algorithm for person identification system utilizing hand vein pattern. The conventional algorithm does not cope with distortion caused by image rotation caused by misplaced hands on the imaging device. A straightforward approach to consider the rotaional compensation required too much computational load, thus, we devised an approach to expect the rotation direction along with image translation, reducing the compuational requirement dramatically In this paper, we present the details of the algorithm with experimental results with the new algorithm.

  • PDF

먼지부하 저감형 하이브리드 여과집진장치(Hi-filter) (A Hybrid Dust Collector(Hi-Filter) for Reducing Dust Load)

  • 최호경;박석주;임정환;김상도;박현설;박영옥
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.223-226
    • /
    • 2002
  • 본 연구에서는 전기집진 기술과 여과집진 기술의 조합에 의한 먼지입자의 포집성능 상승효과를 최대한 높일 수 있는 먼지부하 저감형 하이브리드 집진장치(Hi-Filter)를 개발하기 위해 실험실 규모의 장치를 이용한 실험을 통하여 장치의 최적 형상을 결정하고 그 성능을 검증하였다.(중략)

  • PDF

A control of the parallel IGBT Converter for Auxiliary Block of High Speed Train

  • Geun-Woo Oh
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.543-547
    • /
    • 2000
  • Power factor and harmonics are increasingly important for high speed train auxiliary block. This paper presents experimental results of the power factor and harmonic performance of two parallel PWM circuits under various supply and load conditions. For reducing harmonics the harmonic content is eliminated by the phase shift between two converters switching phase. Experimental results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

고속전철 보조전원장치용 4병렬 IGBT PWM 컨버터에 관한 연구 (A Study on 4 Parallel IGBT PWM Converter for High Speed Train Auxiliary Block)

  • 김연충
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.274-277
    • /
    • 2000
  • Power factor and harmonics are increasingly important for high speed train auxiliary block. This paper presents experimental results of the power factor and harmonic performance of four parallel PWM converter circuits under various supply and load conditions. For reducing harmonics the harmonic content is eliminated by the phase shift between four converters switching phase. Experimental results show the usefulness of the proposed method and applicability to PWM converter in auxiliary block of high speed train.

  • PDF

Metal Dithiophosphates의 합성과 마찰 마모 특성에 관한 연구 (A Study on Synthesis and Wear Characteristics of Metal Dithiophosphates)

  • 김종호;강석춘;정근우;조원오;한두희;박미선
    • Tribology and Lubricants
    • /
    • 제6권2호
    • /
    • pp.68-75
    • /
    • 1990
  • The metal-dithiophosphates as lubricant additives for reducing friction and wear, increasing load-carrying capacity and a antioxidant are very important as new additives developed in these day. The synthetic results of Metal-DTPs were described. The wear test was conducted with 4-Ball machine and wear debris were analyzed by ferrography. The tribological performances of Metal-DTPs were compared with Zn-DTP.

ZVS를 사용한 저전압 CMOS 고집적회로 DC/DC 컨버터의 SPICE 시뮬레이션 (A SPICE SIMULATION FOR A ZVS CMOS DC/DC CONVERTER)

  • 전재훈;김종태
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.259-262
    • /
    • 1999
  • This paper presents the design of highly efficient one-chip CMOS DC/DC converter. The converter operates at the switching frequency of 1MHz for reducing the size of passive elements. And use the zero voltage switching(ZVS) for minimizing switching loss at high frequency. The simulation shows that the circuit can achieve a 95% efficiency while delivering a load of 1W at 2V output.

  • PDF

POWER FACTOR CORRECTION OF CO2 WELDING MACHINE USING SINGLE-SWITCH THREE-PHASE AC/DC CONVERTER

  • Kim, Jse-Mun;Kim, Yuen-Chung;Ahn, Jung-Jun;Won, Chung-Yuen;Kim, Sei-Chan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.663-667
    • /
    • 1998
  • This paper describes for reducing harmonic distortion on CO2 welding machine with nonlinear load characteristic using single-switch three-phase AC/DC converter. The low-order harmonic component amplitude of the phase current of single-switch three-phase discontinuous mode is calculated. Experimental results show that CO2 welding machine with single-switch three-phase AC/DC converter is effectively controlled with power factor correction for phase current during welding time.

  • PDF

행렬법에 의한 선형수동회로의 간략화법 (A Matrix method for the Simplification of Linear Passive Networks)

  • 박영문
    • 전기의세계
    • /
    • 제25권4호
    • /
    • pp.63-67
    • /
    • 1976
  • A new method for simplifying linear, bilateral and passive networks is presented, and the principle employed is based upon the elimination of mutual impedance and floating nodes of the metwork by introducing incidence matrix notations and bus admittance matrices. The method suggested is, particularly, suited for machine computations and applycable for reducing the calculation time in power system short-circuit and load-flow studies with good results.

  • PDF