• Title/Summary/Keyword: liver imaging

Search Result 430, Processing Time 0.036 seconds

Pre-operative Predictive Factors for Intra-operative Pathological Lymph Node Metastasis in Rectal Cancers

  • Gao, Chun;Li, Jing-Tao;Fang, Long;Wen, Si-Wei;Zhang, Lei;Zhao, Hong-Chuan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6293-6299
    • /
    • 2013
  • Background: A number of clinicopathologic factors have been found to be associated with pathological lymph node metastasis (pLNM) in rectal cancer; however, most of them can only be identified by expensive high resolution imaging or obtained after surgical treatment. Just like the Child-Turcotte-Pugh (CTP) and the model for end-stage liver disease (MELD) scores which have been widely used in clinical practice, our study was designed to assess the pre-operative factors which could be obtained easily to predict intra-operative pLNM in rectal cancer. Methods: A cohort of 469 patients who were treated at our hospital in the period from January 2003 to June 2011, and with a pathologically hospital discharge diagnosis of rectal cancer, were included. Clinical, laboratory and pathologic parameters were analyzed. A multivariate unconditional logistic regression model, areas under the curve (AUC), the Kaplan-Meier method (log-rank test) and the Cox regression model were used. Results: Of the 469 patients, 231 were diagnosed with pLNM (49.3%). Four variables were associated with pLNM by multivariate logistic analysis, age<60 yr (OR=1.819; 95% CI, 1.231-2.687; P=0.003), presence of abdominal pain or discomfort (OR=1.637; 95% CI, 1.052-2.547; P=0.029), absence of allergic history (OR=1.879; 95% CI, 1.041-3.392; P=0.036), and direct $bilirubin{\geq}2.60{\mu}mol/L$ (OR=1.540; 95% CI, 1.054-2.250; P=0.026). The combination of all 4 variables had the highest sensitivity (98.7%) for diagnostic performance. In addition, age<60 yr and direct $bilirubin{\geq}2.60{\mu}mol/L$ were found to be associated with prognosis. Conclusion: Age, abdominal pain or discomfort, allergic history and direct bilirubin were associated with pLNM, which may be helpful for preoperative selection.

Diffuse Hepatic Uptake of $^{99m}Tc$-DPD on Whole Body Bone Scan: The Influence of MRI Contrast (전신 뼈 검사에서 $^{99m}Tc$-DPD의 미만성 간 섭취: MRI 조영제의 영향)

  • Yun, Jong Jun;Jeong, Ji Uk;Hwang, Ju Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose : The whole body bone scan on nuclear medicine is a widely accepted examination and procedure. However, unusual nonosseous uptake can be observed, which reflects a rare interaction between the radiopharmacceutical and the patient. This study aimed to evaluate the influence of MRI(Magnetic Resonance Imaging) contrast and $^{99m}Tc$-DPD(Dicarboxpropane diphosphonate) on whole body bone scan. Materials and Methods : We analyzed the 982 patients who were examined by $^{99m}Tc$-DPD on whole body bone scan in nuclear medicine department of pusan national university hospital from january to december 2010. All these 982 patients had MRI contrast administration prior to whole body bone scan. We analyzed laboratory test. Results : 46 patients(men 39, women 7) showed diffuse hepatic uptake on whole body bone scan. These uptakes were disappeared on the follow-up whole body bone scan. There were no significant difference of CBC test, liver function tests and renal function tests. Conclusion : The study might be an indirect evidence that diffuse hepatic and splenic uptake of 99mTc-DPD on whole body bone scan after intravenous administration of Gadolinium(Gd) MRI contrast. To perform a precise examination, Gd-contrast agent should be removed from the body before performing a whole body bone scan.

  • PDF

Impact of Contrast Agent for PET Images with CT-based Attenuation Correction (CT 영상을 이용한 감쇠 보정 시 조영제가 PET 영상에 미치는 영향)

  • Son Hye-Kyung;Turkington Timothy G.;Kwon Yun-Young;Jung Haijo;Kim Hee-Joung
    • Progress in Medical Physics
    • /
    • v.16 no.4
    • /
    • pp.192-201
    • /
    • 2005
  • Experiments and simulation were done to study the impact of contrast agent when CT scan was used to attenuation correction for PET Images in PET/CT system. Whole body phantom was imaged with various concentration of iodine-based contrast agent using CT. Mathematical emission and transmission density map with liver were made to simulate for whole body FDG Imaging. A variety of factors were estimated, including non-uniform enhancement of contrast agent, concentration and distribution size of contrast agent, noise level, image resolution, reconstruction algorithm, hypo-attenuation of contrast agent, and different time phases for contrast agent. Experimental studies showed that Hounsfield unit depends on the concentration of contrast agent and tube voltage. From the simulation data, contrast agents Introduced artifacts and degraded image quality on the attenuation-corrected PET images. The severity of these effects depends on a variety of factors, including the concentration and distribution size of contrast agent, the noise levels, and the Image resolution. These results Indicated that the impact of contrast agents should be considered with a full understanding of their potential problems in clinical PET/CT images.

  • PDF

Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images (Half-fan 모드를 이용한 방사선치료환자 위치교정을 위한 디지털영상 합성영상기술에 관한 예비연구)

  • Park, Justin C.;Park, Sung-Ho;Kim, Jin-Sung;Han, Young-Yih;Ju, Sang-Gyu;Shin, Eun-Hyuk;Shin, Jung-Suk;Park, Hee-Chul;Ahn, Yong-Chan;Song, Willian Y.
    • Progress in Medical Physics
    • /
    • v.21 no.4
    • /
    • pp.360-366
    • /
    • 2010
  • To generate on-board digital tomosynthesis (DTS) for three-dimensionalimage-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT), two clinical cases (liver and bladder) were selected to illustrate the capabilities of on-board DTS for IGRT. DTS images were generated from subsets of CBCT projection data (45, 162 projections) using half-fan mode scanning with a Feldkamp-type reconstruction algorithm. Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information. Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Digital tomosynthesis might allow targeting of the treatment volume on the basis of daily localization.

Detection of Atherosclerotic Lesion with $^{99m}Tc-LDL$ Scintigraphy ($^{99m}Tc-LDL$ (Low Density Lipoprotein)신티그라피를 이용한 동맥경화병소 진단)

  • Kim, Deog-Yoon;Koh, Eun-Mi;Woo, Jeong-Taek;Kim, Sung-Woon;Yang, In-Myung;Kim, Jin-Woo;Kim, Young-Seol;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 1992
  • Diagnostic approaches such as angiography, ultrasound, computed tomography and nuclear magnetic resonance have limitation for contributing to the early clinical diagnosis of atherosclerosis. Recently, $^{99m}Tc-labelled$ low density lipoprotein was developed to detect early atherosclerotic lesion by external imaging with gamma camera. To determine whether $^{99m}Tc-LDL$ scintigraphy can visualize the active atherosclerotic lesion, rabbits were injected with $^{99m}Tc-LDL$, 3 months after feeding dietary fat (lanolin) and we obtained following results. 1) Labelling efficiency of $^{99m}Tc-LDL$ was $79\sim88%$. 2) Biodistribution study of normal rabbits with $^{99m}Tc-LDL$ revealed the high activities in spleen, adrenal gland, liver, kidney which are major organs of high metabolic rate of LDL. 3) Three months after feeding lanolin, serum cholesterol was markedly increased from $74{\pm}17mg/dl$ to $979{\pm}153mg/dl$ and histologic study of aorta after sacrificing the rabbit demonstrated marked atherosclerotic changes. 4) Atherosclerotic lesion of abdominal aorta which was confirmed with histologic study could be demonstrated in $^{99m}Tc-LDL$ scintigraphy after feeding lanolin for 3 months. In conclusion, the results of this preliminary investigation suggest that it may be possible to image active atheromatous lesion with $^{99m}Tc-LDL$. It is anticipated that this promising agent may allow the in vivo monitoring of preclinical atherosclerotic lesions and may be useful to evaluate the metabolic pathway of LDL in humans.

  • PDF

Study a Technique for Reducing the Influence of Scattered Rays from Surrounding Organs to the Heart during Gated Cardiac Blood Pool scan (Gated Cardiac Blood Pool scan에서의 심장 주위 배후방사능 관심영역 설정시 산란선의 영향을 감소시키기 위한 연구)

  • Kim, Jung-Yul;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.33-38
    • /
    • 2008
  • Purpose: The Gated cardiac blood pool scan is non-invasive method that a quantitative evaluation of left ventricular function. Also this scan have shown the value of radionuclide ejection fraction measurements during the course of chemotherapy as a predictor of cardiac toxicity. Therefore a reliable method of monitoring its cardiotoxic effects is necessary. the purpose of this study is to minimize the overestimate of left ventricular ejection fraction (LVEF) by modified body position to reduce the influence of scattered rays from surrounding organs of the heart in the background region of interest. Materials and Methods: Gated cardiac blood pool scan using in vivo $^{99m}Tc$-red blood cell (RBC) was carried out in 20 patients (mean $44.8{\pm}8.6$ yr) with chemotherapy for a breast carcinoma. Data acquisition requires about 600 seconds and 24 frames of one heart cycle by the multigated acquisition mode, Synchronization deteriorates toward the end of the cycle and with the distance from the trigger signal (R-wave) by ECG gating. Gated cardiac blood pool scan was studied with conventional method (supine position and the detector head in $30-45^{\circ}$ left anterior oblique position and caudal $10-20^{\circ}$ tilt) and compared with modified method (left lateral flexion position with 360 mL of drinking water). LVEF analysis was performed by using the automatically computer mode. Results: The ROI counts of modified scan method were lower than LV conventional method ($1429{\pm}251$ versus $1853{\pm}243$, <0.01). And LVEF of modified method was also decrease compared with conventional method ($58.3{\pm}5.6%$ versus $65.3{\pm}6.1%$, <0.01). Imaging analysis indicated that stomach was expanded because of water and spleen position was changed to lateral inferior compared with conventional method. Conclusion: This study shows that the modified method in MUGA reduce the influence of scattered rays from surrounding organs. Because after change the body position to left lateral flexion and drinking water, the location of spleen, left lobe of liver and stomach had changed and they could escaped from background ROI. Therefore, modified method could help to minimize the overestimate LVEF (%).

  • PDF

Comparison of Radionuclide Bone and Gallium Scans in the Therapeutic Evaluation of Bone Lymphoma (골임파종의 치료효과판정을 위한 핵의학적 골스캔과 갈륨스캔의 비교)

  • Moon Tae-Yong;Hwang, In-Tae;Kim, E. Edmund
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.377-383
    • /
    • 1994
  • Objective : We retrospectively analysed $^{99m}Tc$-MDP bone and $^{67}Ga$ scans to evaluate therapeutic response of bone lymphoma among patients with complete remission. Subjects and Methods : We reviewed 35 cases with an increased uptake finding $^{99m}Tc$-MDP bone scans and 16 $^{67}Ga$ scans that were follow-up studies during and after therapy. The $^{99m}Tc$-MDP bone and $^{67}Ga$ scans were graded visually from 1 to 4 in which grade 3 means same uptake density as that of normal sacroiliac articulation in bone scan and normal liver in $^{67}Ga$ scan, respectively. Results: The improvement findings during and after therapy were found in 66.0% (19/ 29) and 72.7% (24/33) with $^{99m}Tc$-MDP bone scan, 84.6% (l1/13) and 86.7% (13/15) with $^{67}Ga$ scan, respectively. The mean grades of the uptake density in $^{99m}Tc$-MDP bone scan were 3.06 before, 2.34 during, 1.75 after therapy. Those in the $^{67}Ga$ scan were 3.22 before, 1.42 during 1.30 after therapy. Conclusion. $^{67}Ga$ scans appeared more sensitive than bone scans in evaluating therapeutic response of bone lymphoma.

  • PDF

Management of Pediatric Small Bowel Intussusception: Spontaneous Reduction vs Operation (소아의 소장 중첩증의 치료 : 자연 정복 vs 수술적 치료)

  • Kim, Eun-Young;Jung, Kyu-Whan;Park, Tae-Jin;Park, Kwi-Won;Jung, Sung-Eun;Kim, Hyun-Young
    • Advances in pediatric surgery
    • /
    • v.16 no.2
    • /
    • pp.117-125
    • /
    • 2010
  • Unreduced small bowel intussusception requires operative treatment although the rate of spontaneous reduction is 60 to 70 %. The aim of this study is to compare clinical characteristics and outcome between spontaneous reduction and operation group and to analyze factors related to decisions to treat small bowel intussusceptions. The records of 25 patients with small bowel intussusceptions treated in Seoul National University Children's Hospital from January 1999 to August 2009 were reviewed respectively. Spontaneous reduction group (n=12, 48 %) had signs and symptoms of vomiting, abdominal pain, currant jelly stool, abdominal distension, fever, increased CRP but no rebound tenderness. One of them had been diagnosed with Henoch-Schonlein purpura and no one displayed pathologic leading point by image study. Operation group (n=13, 52 %) consisted of patients who had primary surgery. Their signs and symptoms were similar to spontaneous reduction group. Seven of them had underlying diseases such as Crohn' disease, ALL, Lymphoma, Peutz-Jeghers syndrome (n=3), post-transplanted state of liver and 2 of them displayed Peutz-Jeghers polyp and Meckel's diverticulum as pathologic leading point by preoperative ultrasonography. Mean relieve interval (interval between onset of symptoms and reduction/operation) was 1.78 days in spontaneous reduction group and 2.25 days in operation group (p=0.341). Seven of operation group had manual reduction and 6 out of 7 received segmental resection of the small bowel. No one of them underwent manual reduction and all of them underwent segmental resection were found to have pathologic leading points [Peutz-Jeghers polyp (n=3), Meckel's diverticulum (n=2), lymphoma (n=1)] during operation. In conclusion, 48% of small bowel intussusceptions resolved spontaneously. Patients' symptoms and relieve intervals were not related to the operative decisions. We therefore recommend significant factors for determining treatment plan such as change of clinical symptoms, underlying disease or pathologic leading point by imaging.

  • PDF

Assessment of Systemic Arterial Thromboembolism with Multi-Slice Spiral CT in a Dog (개에서 다중나선형 CT촬영에 의한 동맥혈전색전증의 평가)

  • Shin, Seung-Ho;Lee, Ki-Chang
    • Journal of Veterinary Clinics
    • /
    • v.24 no.2
    • /
    • pp.208-213
    • /
    • 2007
  • A 15 kg 6-year-old intact male Jindo dog with a history of a respiratory distress, hindlimb paralysis with necrosed skin of dorsal digit for three weeks was referred to Animal Medical Center, Chonbuk National University. Heartworm infection was identified by kit examination. In plain thoracic radiographs, dilated pulmonary arteries reverse D sign and focal interstitial pattern was compatible with heartworm infection and possible pulmonary thromboembolism. Abdominal radiographs showed poor serosal detail indicating fluid accumulation within peritoneal cavity. No evidence of musculoskeletal abnormalities was found. Ultrasonography presented focal wedge-shaped hyperechogenecity on the both poles of left kidney, weak or absent pulse on the distal to the external iliac artery as well as ascites and irregular liver margin. Multi-organ failure was strongly supposed by blood profile including leukocytosis, anemia, hemoglobinuria bililubinemia, hypoalbuminemia, imbalance of electrolytes, and increased hepatic and renal function values. Interestingly, the glucose level is remarkably lower in pelvic limb compared to thoracic limb. Suspected pulmonary thromboembolism, renal infarction and femoral arterial embolization causing hindlimb paralysis and dermatic necrosis were confirmed by 3D reconstructed CT imaging. Prior to taking a consideration of euthanasia, interventional radiology was experimentally attempted but failed due to not recovered from general anesthesia. Early and accurate diagnosis of thromboembolism is valuable and 3D reconstructed CT images might be very useful to show the correct way to treat effectively.

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.