• 제목/요약/키워드: liquid-phase standard

검색결과 297건 처리시간 0.03초

Estimation of liquid limit of cohesive soil using video-based vibration measurement

  • Matthew Sands;Evan Hayes;Soonkie Nam;Jinki Kim
    • Geomechanics and Engineering
    • /
    • 제33권2호
    • /
    • pp.175-182
    • /
    • 2023
  • In general, the design of structures and its construction processes are fundamentally dependent on their foundation and supporting ground. Thus, it is imperative to understand the behavior of the soil under certain stress and drainage conditions. As it is well known that certain characteristics and behaviors of soils with fines are highly dependent on water content, it is critical to accurately measure and identify the status of the soils in terms of water contents. Liquid limit is one of the important soil index properties to define such characteristics. However, liquid limit measurement can be affected by the proficiency of the operator. On the other hand, dynamic properties of soils are also necessary in many different applications and current testing methods often require special equipment in the laboratory, which is often expensive and sensitive to test conditions. In order to address these concerns and advance the state of the art, this study explores a novel method to determine the liquid limit of cohesive soil by employing video-based vibration analysis. In this research, the modal characteristics of cohesive soil columns are extracted from videos by utilizing phase-based motion estimation. By utilizing the proposed method that analyzes the optical flow in every pixel of the series of frames that effectively represents the motion of corresponding points of the soil specimen, the vibration characteristics of the entire soil specimen could be assessed in a non-contact and non-destructive manner. The experimental investigation results compared with the liquid limit determined by the standard method verify that the proposed method reliably and straightforwardly identifies the liquid limit of clay. It is envisioned that the proposed approach could be applied to measuring liquid limit of soil in practical field, entertaining its simple implementation that only requires a digital camera or even a smartphone without the need for special equipment that may be subject to the proficiency of the operator.

Quality Evaluation of Alismatis Rhizoma by High Performance Liquid Chromatography

  • Lee Sang-Myung;Kang Jong-Seong;Hwang Gwi-Seo;Kim Young-Ho;Lee Cheal-Gyu;Yeo Woon-Hyung;Bae Ki-Hwan
    • Archives of Pharmacal Research
    • /
    • 제27권4호
    • /
    • pp.460-464
    • /
    • 2004
  • The quality of Alismatis Rhizoma was evaluated by reversed-phase high performance liquid chromatographic method. Alisol B 23-acetate was used as a standard marker for evaluation. This component was fully separated from the other components in the plant extracts on a ODS column. Identifcation of alisol B 23-acetate was carried out by comparing the LC/MS spectrum of separated peak from the extract with that of standard. Alisol B 23-acetate contents in Alismatis Rhizoma obtained from several herbal markets were varied from $0. 15\%$ to $0.56\%$.

혈장중 Acebutolol 및 그 Acetyl 대사체의 HPLC 분석 (High Performance Liquid Chromatographic Assay of Acebutolol and its Acetyl Metabolite in Plasma)

  • 백채선
    • Journal of Pharmaceutical Investigation
    • /
    • 제23권3호
    • /
    • pp.133-137
    • /
    • 1993
  • A high-performance liquid chromatographic assay using ion-pair reverse-phase system was developed for the separation of acebutolol and acebutolol acetyl metabolite in plasma. A ion-pair reversephase system consisting of an ODS-bonded silica column and a mixture of 20% $CH_3CN$, 0.1% $H_3PO_4$, 0.035 M heptanesulfonic acid and 0.005 M tetrabutylammonium hydrogen sulfate as the mobile phase were used. Triamterene was employed as an internal standard. Based on 0.2 ml of plasma, the detection limits were 10.4 ng/ml for acebutolol and 10.3 ng/ml of acebutolol acetyl metabolite at the signal-to-noise ratio of 3:1.

  • PDF

Determination of dextromethorphan and its metabolite dextrorphan in human urine by High-performance liquid chromatography

  • Son, Haeng-Ja;Park, Mee-Jung;Choi, Sang-Kil;Lim, Mi-Ae;Chung, Hee-Sun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.279.2-280
    • /
    • 2003
  • A simple and accurate reverse-phase high performance liquid chromatography (HPLC) coupled with photodiode array was developed for the determination of dextromethorphan(DM) and its metabolite dextrorphan(DX) in human urine. Chromatographic separation was accomplished on a cyano analytical column at 220 nm using a mobile phase containing 25 mM triethylammonium phosphate buffer(PH 3.0) in a 0-70% ACN gradient and triazolam(TZ) was used as internal standard(I.S). (omitted)

  • PDF

Simultaneous determination of sildenafil and its active metabolite in human plasma using LC/MS/MS

  • Ji, Hye-Young;Kim, Sook-Jin;Lee, Hong-Il;Lee, Seung-Seok;Lee, Hye-Sook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.402.1-402.1
    • /
    • 2002
  • The LC/MS/MS method for the simultaneous determination of sildenafil and its active metabolite N-demethylsildenafil in human plama was developed. Sildenafil. its active metabolite and the internal standard. DA-8159 were extracted form human plasma by liquid-liquid partitioning. A reverse-phase HPLC separation was performed on Luna phenylhexyl column with the mixture of acetonitrile-5 mM ammonium formate (55:45. v/v) as mobile phase. (omitted)

  • PDF

Determination of a Novel Antiangiogenic Agent KR-31831 in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry

  • Kim, Sook-Jin;Lee, Seung-Seok;Ji, Hye-Young;Lee, Hong-Il;Lee, Seon-Kyoung;Yi, Kyu-Yang;Yoo, Seong-Eun;Hwang, Jeong-Sook;Lee, Hye-Suk
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.217.2-217.2
    • /
    • 2003
  • A liquid chromatography-tandem mass spectrometric (LC/MS/MS) method was developed for the determination of a new anti-angiogenic drug KR-31831 in rat plasma. KR-31831 and internal standard, KR-31543 were extracted from rat plasma with dichloromethane at basic pH. A reverse-phase LC separation was performed on Luna C8 column with the mixture of acetonitrile-ammonium formate (10 mM, pH 4.5) (67:33, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple-reaction-monitoring mode. (omitted)

  • PDF

Simultaneous Determination of the Water Soluble Vitamins in Multi-Nutrient Tablets by Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Hyung-Soo;Jang, Duck-Kyu;Woo, Dong-Kyun;Woo, Kang-Lyung
    • Preventive Nutrition and Food Science
    • /
    • 제7권1호
    • /
    • pp.12-17
    • /
    • 2002
  • Simultaneous determination of nine water-soluble vitamins contained in multi-nutrient tablets was carried out by reversed phase high-performance liquid chromatography (RP-HPLC) equipped with analytical $C_{18}$ column and UV (270 nm) detector. Those standard vitamins were successfully separated within 23 minutes by gradient elution with solvent A (0.5 M potassium phosphate monobasic) and solvent B (0.25 M potassium phosphate monobasic-methanol, 1:1). Calibration curves showed good linealities with correlation coefficients (> 0.92) in tested ranged respectively. The detection limits were considered to be 2.1 ng for ascorbic acids 60 ng for Vit B$_{6}$ 3 ng for p-aminobenzoic acid, 9 ng for niacinamide, 9 ng for thiamin, 5.0 ng for folic acid and 1.5 ng for riboflavin at 0.05 a.u.f.s. Solid phase extraction through Sep-Pak (C$_{18}$ ) cartridge was successfully applied for purification of water soluble vitamins in commercial multi-nutrient tablets.ts.

Ionic liquid coated magnetic core/shell CoFe2O4@SiO2 nanoparticles for the separation/analysis of trace gold in water sample

  • Zeng, Yanxia;Zhu, Xiashi;Xie, Jiliang;Chen, Li
    • Advances in nano research
    • /
    • 제10권3호
    • /
    • pp.295-312
    • /
    • 2021
  • A new ionic liquid functionalized magnetic silica nanoparticle was synthesized and characterized and tested as an adsorbent. The adsorbent was used for magnetic solid phase extraction on ICP-MS method. Simultaneous determination of precious metal Au has been addressed. The method is simple and fast and has been applied to standard water and surface water analysis. A new method for separation/analysis of trace precious metal Au by Magnetron Solid Phase Extraction (MSPE) combined with ICP-MS. The element to be tested is rapidly adsorbed on CoFe2O4@SiO2@[BMIM]PF6 composite nano-adsorbent and eluted with thiourea. The method has a preconcentration factor of 9.5-fold. This method has been successfully applied to the determination of gold in actual water samples. Hydrophobic Ionic Liquids (ILs) 1-butyl-3-methylimidazole hexafluorophosphate ([BMIM]PF6) coated CoFe2O4@SiO2 nanoparticles with core-shell structure to prepare magnetic solid phase extraction agent (CoFe2O4@SiO2@ILs) and establish a new method of MSPE coupled with inductively coupled plasma mass spectrometry for separation/analysis of trace gold. The results showed that trace gold was adsorbed rapidly by CoFe2O4@SiO2@[BMIM]PF6 and eluanted by thiourea. Under the optimal conditions, preconcentration factor of the proposed method was 9.5-fold. The linear range, detection limit, correlation coefficient (R) and relative standard deviation (RSD) were found to be 0.01~1000.00 ng·mL-1, 0.001 ng·mL-1, 0.9990 and 3.4% (n = 11, c = 4.5 ng·mL-1). The CoFe2O4@SiO2 nanoparticles could be used repeatedly for 8 times. This proposed method has been successfully applied to the determination of trace gold in water samples.

Dispersive Solid Phase Extraction을 사용한 우유 내 잔류농약 다성분 동시 분석법 비교연구 (Comparative Evaluation of the Analytical Methods used to Determine Pesticide Residues in Milk via Dispersive Solid Phase Extraction)

  • 오남수;신용국;이지영;백승천
    • Journal of Dairy Science and Biotechnology
    • /
    • 제33권1호
    • /
    • pp.27-34
    • /
    • 2015
  • 본 연구에서는 dispersive-SPE를 사용하여 간편하고, 신속하며, 경제적인 우유 내 19종 잔류농약의 동시 다성분 분석법을 설정하고자 하였다. Liquid-liquid partitioning method와 low-temperature cleanup method를 적용한 추출방법과 PSA 및 PSA + C18의 sorbent가 사용된 dispersive-SPE를 사용한 정제방법을 비교 실험하였으며, GC/MS의 선택이온 검색법(selected ion monitoring, SIM)으로 정량 분석하였다. matrix-matched standards와 matrix-free standards를 사용하여 분석방법의 matrix enhancement effect를 확인하였고, 분석방법 설정을 위한 비교실험의 결과, low-temperature cleanup 방법으로 추출하여 dispersive-SPE(PSA + C18)로 정제하는 방법이 시료 추출물의 간섭물질을 제거하는데 가장 효과적이고, 첨가한 $1{\mu}g/mL$에 대한 개별 농약 성분의 회수율 또한 전체적으로 가장 높은 수준을 나타내었으며, 모든 농약 성분의 RSD(%)가 20% 이하로서 기준에 적합한 재현성을 나타내었다.

  • PDF

Simultaneous Determination of the Novel Neuroprotective Agent KR-31378 and its Metabolite KR-31612 Using High Performance Liquid Chromatography with Tandem Mass Spectrometry in Human Plasma

  • Kim, John;Ji, Hye-Young;Yoo, Sung-Eun;Kim, Sun-Ok;Lee, Dong-Ha;Lim, Hong;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • 제25권5호
    • /
    • pp.647-651
    • /
    • 2002
  • An LC/MS/MS method for the simultaneous determination of a neuroprotective agent for ischemia-reperfusion damage, KR-31378 and its N-acetyl metabolite KR-31612 in human plasma was developed. KR-31378, KR-31612 and the internal standard. KR-31543 were extracted from human plasma by liquid-liquid extraction. A reverse-phase HPLC separation was performed on Luna phenylhexyl column with the mixture of acetonitrile-5 mM ammonium formate (55:45, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple reaction monitoring mode. The lower limits of quantification for KR-31378 and KR-31612 were 2.0 ng/ml. The method showed a satisfactory sensitivity, precision, accuracy, recovery and selectivity.