• Title/Summary/Keyword: liquid-phase standard

Search Result 297, Processing Time 0.024 seconds

A study on the analysis of artificial sweeteners in processed foods including emulsified foods by HPLC-DAD

  • Kim, Min-Hee;Lee, Do-Yeon;Ahn, Jang-Hyuk
    • Analytical Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.209-214
    • /
    • 2020
  • This study has been carried out to develop a standard method for quantifying of 3 permitted artificial sweeteners (including sodium saccharine, aspartame, acesulfame potassium) contained in foods by HPLC-DAD. A simple and rapid sample pretreatment method was used to remove fat and protein from the test solution with Carrez clearing regent precipitant know to be effective for protein and fat removal. The artificial sweeteners in the test solution purified through sample pretreatment were detected by high performance liquid chromatograph using a Reverse phase C18 column (5 ㎛, 4.6 × 250 mm). The simultaneous quantitative test of 3 kinds of artificial sweeteners can be effectively performed on the high fat emulsified foods containing a large amount of fat. Using the established simultaneous quantitative test method, artificial sweeteners were tested in foods such as dairy products, snacks and chocolate. The results calibration curve showed good linearity with high regression coefficients and the result of recovery test showed satisfactory recoveries within 80~110 %.

Determination of Theophylline and its Metabolites in Human Urine by High-Performance Liquid Chromatography

  • Kim, Kyeong-Ho;Park, Young-Hwan;Park, Hyo-Kyung;Kim, Ho-Soon;Lee, Min-Hwa
    • Archives of Pharmacal Research
    • /
    • v.19 no.5
    • /
    • pp.396-399
    • /
    • 1996
  • High-performance liquid chromatographic method with UV detecction was developed for the determination of theophylline and its metabolites in human urine using ${beta}$-hydroxyethyl theophylline$({beta} -HET)$ as an internal standard. For extraction of urine sample, quality control sample and xanthine-free blank urine were mixed with decylamine (ion-paring reagent) and ${beta}$-HET. After saturation with ammonium sulfate, the mixture was then extracted with organic solvent at pH values of 4.0-4.5. All separations were performed with ion-pair chromatography using decylamine as an ion-pairing reagent and 3mM sodium acetate buffered mobile phase (pH 4.0) containing 1% (v/v) acetonitrile and 0.75 mM decylamine. The detection limits of theophylline, 1, 3-DMU, 1-MU, 3-MX and 1-MX in human urine were 0.17, 0.17, 0.39, 0.19 and 0.19 ${\mu}g$/ml, based on a signal-to-noise ratios of 3.0. The mean intraday coefficients of variation (C.V.s) of each compound on nine replicates were lower than 2.0%, while mean interday C.V.s on three days were lower than 1.6%. All separations were finished within 40miutes.

  • PDF

Determination of ${\alpha}-Keto$ Acids in Serum and Urine Using 1,2-Diamino-4,5-methylendioxybenzene as a Fluorescent Derivatizating Agent by High Performance Liquid Chromatography (HPLC법에 의한 1,2-디아미노-4,5-메틸렌디옥시벤젠을 형광유도체화제로 한 혈청 및 뇨 중의 ${\alpha}$-케토산의 분석)

  • Ok, Chi-Wan;Kim, Dae-Ki;Park, Song-Ja;Park, Jong-Sei
    • YAKHAK HOEJI
    • /
    • v.36 no.4
    • /
    • pp.370-378
    • /
    • 1992
  • A simple and sensitive high performance liquid chromatographic method to quantitate ${\alpha}-keto$ acids in serum and urine was investigated. ${\alpha}-Keto$ acids react with 1,2-diamino-4,5-methylenedioxybenzene (DMB) in the presence of 2-mercapto-ethanol and sodium hydrogen sulfite to form highly fluorescent derivatives, substituted 6,7-methylenedioxyquinoxalinol. The derivatization procedure was performed in water bath at $100^{\circ}C$, and completed within 50 min. By the use of a reversed-phase column and multi-step gradient with two solvents, a mixture containing twelve of these derivatives were efficiently resolved within 35 minutes. The optimal wavelengh of the fluorescence detector are ${\lambda}_{ex}=364\;nm$ and ${\lambda}_{em}=445\;nm$. The quantitation of the individual ${\alpha}-Keto$ acids was reproducible with relative standard deviation of $3.0{\sim}7.9%$ and had a detection limits of $10{\sim}60$ fmol, except for p-hydroxyphenylpyruvic acid (960 fmol).

  • PDF

Development and Validation of a Unique HPLC-ELSD Method for Analysis of 1-Deoxynojirimycin Derived from Silkworms (누에에 함유된 1-Deoxynojirimycin의 분석을 위한 HPLC-ELSD 분석법 밸리데이션)

  • Hyejin Cho;Sullim Lee;Myoung-Sook Shin;Joohwan Lee;Sanghyun Lee
    • Korean Journal of Pharmacognosy
    • /
    • v.54 no.1
    • /
    • pp.38-43
    • /
    • 2023
  • A simple and accurate assay was developed for the quantitative analysis of 1-deoxynojirimycin (1-DNJ) derived from the silkworm (Bombyx mori). Normal-phase high-performance liquid chromatography coupled with an evaporative light scattering detector (HPLC-ELSD) and a hydrophilic interaction liquid chromatography column was used. Various parameters were applied to optimize the analysis method. The limits of detection and quantification of 1-DNJ were 2.97 × 10-3 and 9.00 × 10-3 mg/mL, respectively. The calibration curve showed good linearity results. The concentration range and the r2 value were 0.0625-1.0 mg/mL and 0.9997, respectively. The accuracy test demonstrated a significantly high recovery rate (89.95-103.22%). The relative standard deviation was ≤ 1.00%. Thus, a method for the accurate identification and quantitative analysis of 1-DNJ in silkworms was developed. Moreover, in this procedure, the process of derivatization of 1-DNJ, which was required in previous experiments, could be eliminated. This technique may be actively utilized for the development of pharmaceuticals and health functional foods using 1-DNJ.

Stellite bearings for liquid Zn-/Al-Systems with advanced chemical and physical properties by Mechanical Alloying and Standard-PM-Route

  • Zoz, H.;Benz, H.U.;Huettebraeucker, K.;Furken, L.;Ren, H.;Reichardt, R.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2000.04a
    • /
    • pp.9-10
    • /
    • 2000
  • An important business-field of world-wide steel-industry is the coating of thin metal-sheets with zinc, zinc-aluminum and aluminum based materials. These products mostly go into automotive industry. in particular for the car-body. into building and construction industry as well as household appliances. Due to mass-production, the processing is done in large continuously operating plants where the mostly cold-rolled metal-strip as the substrate is handled in coils up to 40 tons unwind before and rolled up again after passing the processing plant which includes cleaning, annealing, hot-dip galvanizing / aluminizing and chemical treatment. In the liquid Zn, Zn-AI, AI-Zn and AI-Si bathes a combined action of corrosion and wear under high temperature and high stress onto the transfer components (rolls) accounts for major economic losses. Most critical here are the bearing systems of these rolls operating in the liquid system. Rolls in liquid system can not be avoided as they are needed to transfer the steel-strip into and out of the crucible. Since several years, ceramic roller bearings are tested here [1.2], however, in particular due to uncontrollable Slag-impurities within the hot bath [3], slide bearings are still expected to be of a higher potential [4]. The today's state of the art is the application of slide bearings based on Stellite\ulcorneragainst Stellite which is in general a 50-60 wt% Co-matrix with incorporated Cr- and W-carbides and other composites. Indeed Stellite is used as the bearing-material as of it's chemical properties (does not go into solution), the physical properties in particular with poor lubricating properties are not satisfying at all. To increase the Sliding behavior in the bearing system, about 0.15-0.2 wt% of lead has been added into the hot-bath in the past. Due to environmental regulations. this had to be reduced dramatically_ This together with the heavily increasing production rates expressed by increased velocity of the substrate-steel-band up to 200 m/min and increased tractate power up to 10 tons in modern plants. leads to life times of the bearings of a few up to several days only. To improve this situation. the Mechanical Alloying (MA) TeChnique [5.6.7.8] is used to prOduce advanced Stellite-based bearing materials. A lubricating phase is introduced into Stellite-powder-material by MA, the composite-powder-particles are coated by High Energy Milling (HEM) in order to produce bearing-bushes of approximately 12 kg by Sintering, Liquid Phase Sintering (LPS) and Hot Isostatic Pressing (HIP). The chemical and physical behavior of samples as well as the bearing systems in the hot galvanizing / aluminizing plant are discussed. DependenCies like lubricant material and composite, LPS-binder and composite, particle shape and PM-route with respect to achievable density. (temperature--) shock-reSistibility and corrosive-wear behavior will be described. The materials are characterized by particle size analysis (laser diffraction), scanning electron microscopy and X-ray diffraction. corrosive-wear behavior is determined using a special cylinder-in-bush apparatus (CIBA) as well as field-test in real production condition. Part I of this work describes the initial testing phase where different sample materials are produced, characterized, consolidated and tested in the CIBA under a common AI-Zn-system. The results are discussed and the material-system for the large components to be produced for the field test in real production condition is decided. Outlook: Part II of this work will describe the field test in a hot-dip-galvanizing/aluminizing plant of the mechanically alloyed bearing bushes under aluminum-rich liquid metal. Alter testing, the bushes will be characterized and obtained results with respect to wear. expected lifetime, surface roughness and infiltration will be discussed. Part III of this project will describe a second initial testing phase where the won results of part 1+11 will be transferred to the AI-Si system. Part IV of this project will describe the field test in a hot-dip-aluminizing plant of the mechanically alloyed bearing bushes under aluminum liquid metal. After testing. the bushes will be characterized and obtained results with respect to wear. expected lifetime, surface roughness and infiltration will be discussed.

  • PDF

Determination of Hydrochlorothiazide in Human Plasma by HPLC and Applicability to Oral Bioavailability in Korean Healthy Male Volunteers (HPLC를 이용한 혈중 히드로클로로티아지드의 분석 및 이를 이용한 한국인 성인남성에 대한 생체이용률 평가)

  • Park, Ah-Yeon;Kim, Jin-Hee;Kim, Sung-Yong;Chi, Sang-Cheol;Bok, Hae-Sook;Kim, Ho-Jung;Youm, Jeong-Rok;Han, Sang-Beom
    • YAKHAK HOEJI
    • /
    • v.50 no.5
    • /
    • pp.301-307
    • /
    • 2006
  • A simple and sensitive high-performance liquid chromatographic method for quantitation of hydrochlorothiazide in human plasma was developed and bioavailability parameters of hydrochlorothiazide were assessed in Korean healthy male volunteers. Caffeine was used as an internal standard. Hydrochlorothiazide and internal standard in plasma sample were extracted using tert-butylmethylether (TBME). A centrifuged upper layer was then evaporated and reconstituted with mobile phase of acetonitrile-25 mM phosphate buffer (20/80, pH 2.5). The reconstituted samples were injected into a Luna C18 column $(250{\times}4.6\;mm,\;5{\mu}m)$ at a flow-rate of 1.0 ml/min. The wavelength was set at 230 nm and no endogenous substances were found to interfere, A linear relationship for hydrochlorothiazide was found in the range of $10{\sim}300\;ng/ml$. The lower limit of quantitation (LLOQ) was 10 ng/ml with acceptable precision and accuracy. Assayed in plasma, the intra- and inter-day validation for all coefficients of variation (R.S.D.%) were found less than 15%. Main pharmacokinetic parameters of 50mg of hydrochlorothiazide were revealed as follows: $AUC_t\;1761{\pm}509.0\;ng{\cdot} hr\;ml,\;C_{max}\;296.5{\pm}95.5\;ng/ml,\;T_{max}\;1.94{\pm}0.85hr,\;K_{el}\;0.12{\pm}0.04\;hr^{-1}\;and T_{12}\;6.81{\pm}2.92\;hr.\;C_{max}\;and\;T_{max}$ were in accordance with the values $(270{\sim}350\;ng/ml\;and\;1.9{\sim}2.7\;hr)$ of Caucasian.

Simultaneous Determination of Polycyclic Aromatic Hydrocarbons and Their Nitro-derivatives in Airborne Particulates by Using Two-dimensional High-performance Liquid Chromatography with On-line Reduction and Fluorescence Detection

  • Boongla, Yaowatat;Orakij, Walaiporn;Nagaoka, Yuuki;Tang, Ning;Hayakawa, Kazuichi;Toriba, Akira
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.283-299
    • /
    • 2017
  • An analytical method using high-performance liquid chromatography (HPLC) with fluorescence (FL) detection was developed for simultaneously analyzing 10 polycyclic aromatic hydrocarbons (PAHs) and 18 nitro-derivatives of PAHs (NPAHs). The two-dimensional HPLC system consists of an on-line clean-up and reduction for NPAHs in the 1st dimension, and separation of the PAHs and the reduced NPAHs and their FL detection in the 2nd dimension after column-switching. To identify an ideal clean-up column for removing sample matrix that may interfere with detection of the analytes, the characteristics of 8 reversed-phase columns were evaluated. The nitrophenylethyl (NPE)-bonded silica column was selected because of its shorter elution band and larger retention factors of the analytes due to strong dipole-dipole interactions. The amino-substituted PAHs (reduced NPAHs), PAHs and deuterated internal standards were separated on polymeric octadecyl-bonded silica (ODS) columns and by dual-channel detection within 120 min including clean-up and reduction steps. The limits of detection were 0.1-9.2 pg per injection for PAHs and 0.1-140 pg per injection for NPAHs. For validation, the method was applied to analyze crude extracts of fine particulate matter ($PM_{2.5}$) samples and achieved good analytical precision and accuracy. Moreover, the standard reference material (SRM1649b, urban dust) was analyzed by this method and the observed concentrations of PAHs and NPAHs were similar to those in previous reports. Thus, the method developed here-in has the potential to become a standard HPLC-based method, especially for NPAHs.

Development and validation of LC-MS/MS for bioanalysis of hydroxychloroquine in human whole blood

  • Park, Jung Youl;Song, Hyun Ho;Kwon, Young Ee;Kim, Seo Jin;Jang, Sukil;Joo, Seong Soo
    • Journal of Biomedical and Translational Research
    • /
    • v.19 no.4
    • /
    • pp.130-139
    • /
    • 2018
  • This study aimed to analyze a high-performance liquid chromatography (HPLC) separation using a pentafluorophenyl column of parent drug hydroxychloroquine (HCQ) and its active metabolite, desethylhydroxchloroquine (DHCQ) applying to determine bioequivalence of two different formulations administered to patients. A rapid, simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for bioanalysis of HCQ and its metabolite DHCQ in human whole blood using deuterium derivative $hydroxychloroquine-D_4$ as an internal standard (IS). A triple-quadrupole mass spectrometer was operated using electrospray ionization in multiple reaction monitoring (MRM) mode. Sample preparation involves a two-step precipitation of protein techniques. The removed protein blood samples were chromatographed on a pentafluorophenyl (PFP) column ($50mm{\times}4.6mm$, $2.6{\mu}m$) with a mobile phase (ammonium formate solution containing dilute formic acid) in an isocratic mode at a flow rate of 0.45 mL/min. The standard curves were found to be linear in the range of 2 - 500 ng/mL for HCQ; 2 - 2,000 ng/mL for DHCQ in spite of lacking a highly sensitive MS spectrometry system. Results of intra- and inter-day precision and accuracy were within acceptable limits. A run time of 2.2 min for HCQ and 2.03 min for DHCQ in blood sample facilitated the analysis of more than 300 human whole blood samples per day. Taken together, we concluded that the assay developed herein represents a highly qualified technology for the quantification of HCQ in human whole blood for a parallel design bioequivalence study in a healthy male.

Analysis of Scutellaria baicaleinsis Georgi (Scutellariae Radix) by LC-DAD and LC-ESI/MS

  • Yu, Youngbob;Choi, Pil-Son;Koo, Sungtae;Chang, Suhwan
    • Korean Journal of Plant Resources
    • /
    • v.31 no.6
    • /
    • pp.652-659
    • /
    • 2018
  • In this study, baicalin, as a marker substance of Scutellariae Radix, was quantitatively analyzed by a high performance liquid chromatography-photodiode array detector (HPLC-DAD). We identified wogonoside, baicalein, and wogonin in the Scutellariae Radix by a high performance liquid chromatography-electrospray ionization-mass spectrometer (HPLC-ESI-MS). The baicalin was separated on a Xterra C18 column ($5{\mu}m$, $4.6{\times}250mm$) using mobile phase consisting of 38% acetonitrile in 0.68% phosphoric acid. The baicalin spectrum in the Scutellariae Radix extracts was coincided by comparing with UV-visible spectrum (200-550 nm) of baicalin standard in the library. The amount of baicalin in Scutellariae Radix was 10.46%, which is higher than KFDA's guideline. The marker substances of Scutellariae Radix showed a strong base peak $[M]^+$ in the positive detection mode following as; baicalin (m/z; $271[MH^+-sugar]^+$, $447[M+H]^+$), wogonoside (m/z; $285[MH^+-sugar]^+$, $461[M+H]^+$), baicalein (m/z; $271\;[M+H]^+$), wogonin (m/z; $285[M+H]^+$). These results are consistent with the fragment pattern and molecular weight of standard components from literature.

Analysis of Haloacetic Acids in Drinking Water by Direct Derivatization and Headspace-SPME Technique with GC-MS (Handspace Solid Phase Microextraction 방법에 의한 HAAs 분석에 관한 연구)

  • Cho, Deok-Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.5
    • /
    • pp.638-648
    • /
    • 2004
  • In many drinking water treatment plants, chlorination process is one of the main techniques used for the disinfection of water. This disinfecting treatment leads to the formation of haloacetic acid (HAAs). In this study, headspace solid-phase microextraction (HS-SPME) was studied as a possible alternative to liquid-liquid extraction for the analysis of HAAs in drinking water. The method involves direct derivatization of the acids to their methyl esters without methyl tert-butyl ether (MTBE) extraction, followed by HS-SPME with a $2cm-50/30{\mu}m$ divinylbenzene/carboxen/polydimethylsiloxane fiber. The effects of experimental parameters such as selection of SPME fiber, the volume of sulphuric acid and methanol, derivatization temperature and time, the addition of salts, extraction temperature and time, and desorption time on the analysis were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The $2cm-50/30{\mu}m$-divinylbenzene/carboxen/polydimethylsiloxane fiber, sulphuric acid of 1ml, methanol of 3ml, derivatization temperature of $50^{\circ}C$ derivatization time of 2hrs, sodium chloride salt of 10g, extraction time of 30 minutes, extraction temperature of $20^{\circ}C$ and desorption time of 1 minute at $260^{\circ}C$ were selected as the optimal experimental conditions for the analysis of HAAs. The linearities ($r^2$), relative standard deviations (%RSD) and limits of detection (LOD) for HAAs were 0.9978~0.9991, 1.1~9.8% and $0.05{\sim}0.2{\mu}g/l$, respectively.