• Title/Summary/Keyword: liquid-phase standard

Search Result 296, Processing Time 0.025 seconds

A Study of Calibration Bias in the Analysis of Airborne Carbonyl Compounds between Gaseous and Liquid-phase Standards by High Performance Liquid Chromatography (HPLC) (대기 중 Carbonyl 성분들의 검량 분석 기술에 대한 연구: 액상 대비 기체상 표준시료의 오차발생 특성 연구)

  • Lee, Min-Hee;Kim, Ki-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.52-58
    • /
    • 2012
  • In this study, the effect of standard phase difference in calibration of carbonyl compounds (CC) was evaluated by using their standards prepared in both gaseous and liquid phase. For this analysis, standards in both phases were prepared for 6 different CCs (formaldehyde (FA), acetaldehyde (AA), propionaldehyde (PA), butyraldehyde (BA), isovaleraldehyde (IA) and valeraldehyde (VA)) at similar concentration levels. Their gaseous standard was calibrated after derivatization with three types of DNPH cartridge, and their calibration results were compared against liquid-phase standards. Although there was a strong compatibility between 2 phases for CCs with lower molecular weights (e.g., formaldehyde and acetaldehyde), it was not the case for the heavier CCs. The results of our analysis indicate that the analytical bias of the heavier CCs can be significantly large (by more than a few tens of %). As a result, underestimation of hevier CCs can be significant, if their gaseous samples are quantified by liquid phase standard.

Multichannel Liquid Phase Microextraction System (다채널 액상 미세 추출 시스템 설계 및 제작)

  • Zhang, XinJie;Cheng, Shuo;Piao, Xiang Fan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, a multichannel gas-liquid microextraction system is designed by integrating the automatic elution of extraction line and multichannel gas-purging liquid phase microextraction. The system uses an injection pump and inert gas to push the extraction solvent to a sample bottle of a gas-phase color autosampler and then implements multichannel gas-liquid microextraction and gas chromatography-mass spectrometry. The system also employs a three-way integrated micro-high-temperature heater, syringe pump, and microflow controller to realize the simultaneous processing of multiple groups of samples, thus improving the sample pretreatment speed and reproducibility and reducing human error. Autoinjection experiments were implemented with polycyclic aromatic hydrocarbon standard samples. The experiments show that the average recovery rate of the system exceeds 70%, and the relative standard among the channels is less than 15%.

Numerical Analysis of Solidification and Melting Phase Change Using Modified PISO algorithm (수정된 PISO 알고리즘을 이용한 응고 및 융해 현상의 수치해석)

  • Kang K. G;Ryou H. S;Hur N.
    • Journal of computational fluids engineering
    • /
    • v.8 no.3
    • /
    • pp.12-20
    • /
    • 2003
  • A numerical procedure for the calculation of solidification and melting phase change using PISO algorithm is presented. In case of phase change problem, the coupling between velocity/pressure/temperature and liquid fraction is important. The converged temperature and liquid fraction solution which satisfies the energy balance is acquired by applying enthalpy method into inner iteration in matrix solver. And a modified PISO algorithm version is introduced to properly solve the coupling between velocity/pressure/temperature and liquid fraction. A comparison of the proposed procedure with a standard iterative method shows improvement both in terms of computing speed and robustness.

A comparative analysis of gas and liquid phase standard spiked solid sorbent tubes for the determination of volatile organic compounds in indoor air by TD-GC/MS (열탈착/저온농축-GC/MS에 의한 실내공기 중 휘발성 유기화합물 정량용 기체상 및 액체상 표준물질 첨가한 고체 흡착관의 비교 분석)

  • Lim, Hyun-Woo;Jung, Sung-Won;Kang, Chul-Ho;Park, Jin-Sook;Park, Byeong Moo;Choi, Yong-Wook
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.287-297
    • /
    • 2013
  • The optimization of analytical method for the thermal desorption of seven VOCs (volatile organic compounds) by TD-GC/MS (thermal desorption-gas chromatograph-mass spectrometer) with solid phase sorbent tube, and comparative analysis for the determination of VOCs plotted by standard sorbent tubes prepared using both gas phase and liquid phase materials were investigated. The result of paired t-test showed that a liquid phase standard sorbent tube method was in agreement with a gas phase standard sorbent tube method for six species of VOCs including benzene, toluene, ethylbenzene, o-, m-, and p-xylene except for styrene at the significance level (${\alpha}=0.01$), while the 15.6% of difference in response factor between both of gas phase and liquid phase standard plotting for the determination of styrene showed that both methods were significantly different at the significance level. Therefore, the liquid phase standard plotting method was employed to reduce erroneous data for the determination of styrene including BTEX. Under the optimized analytical method by liquid phase standard sorbent tube, recovery was between $100{\pm}5%$ for 7 species of VOCs, reproducibility ranged from 0.3 to 7.7%, and method detection limit (MDL) ranged from $0.01{\mu}g/m^3$ for o-xylene to $0.27{\mu}g/m^3$ for toluene. The optimized standard method was applied to determine VOCs VOCs from indoor air of of dormitory, one bedroom apartment, and a new car.

Multicomponent pesticides analysis by automated liquid phase microextraction (자동화된 LPME(Liquid Phase Microextraction)장치를 이용한 다성분 농약분석)

  • Myung, Seung-Woon;Jung, Hong-Rae
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.224-231
    • /
    • 2005
  • In this study, the optimum conditions for the LPME (liquid phase microextraction) were investigated to overcome several shortcomings of traditional liquid-liquid extraction method. The LPME, which is automatic and dynamic, was used to analyze the five pesticides (dementon-S-methyl, diazinon, parathion, fenitrothion, EPN) extracted from vegetable, and HP 6890 GC/NPD was used as an analytic instrument. It was possible to optimize the extraction condition using the automatic LPME. The optimum extraction rate was obtained at pH 3.0 and $100{\mu}g/mL$ of salt concentration and standard curve showed linearity with over $R^2=0.9921$ in the range of $0.2{\sim}10{\mu}g/g$. The relative standard deviations were 7.7%, 9.8%, 7.8%, 9.7% and 8.2% in the $5.0{\mu}g/g$ concentration of dementon-S-methyl, diazinon, parathion, fenitrothion and EPN, respectively. The acquired accuracies were satisfactory showing 12.7%, 7.8%, 10.4%, -6.7% and -0.7% for dementon-S-methyl, diazinon, parathion, fenitrothion and EPN respectively.

Improved Calibration for the Analysis of Emerging Contaminants in Wastewater Using Ultra High Performance Liquid Chromatography and Time-of-Flight Mass Spectrometry

  • Pellinen, Jukka;Lepisto, Riikka-Juulia;Savolainen, Santeri
    • Mass Spectrometry Letters
    • /
    • v.9 no.3
    • /
    • pp.77-80
    • /
    • 2018
  • The focus of this paper is to present techniques to overcome certain difficulties in quantitative analysis with a time-of-flight mass spectrometer (TOF-MS). The method is based on conventional solid-phase extraction, followed by reversed-phase ultra high performance liquid chromatography of the extract, and mass spectrometric analysis. The target compounds included atenolol, atrazine, caffeine, carbamazepine, diclofenac, estrone, ibuprofen, naproxen, simazine, sucralose, sulfamethoxazole, and triclosan. The matrix effects caused by high concentrations of organic compounds in wastewater are especially significant in electrospray ionization mass spectroscopy. Internal-standard calibration with isotopically labeled standards corrects the results for many matrix effects, but some peculiarities were observed. The problems encountered in quantitation of carbamazepine and triclosan, due to nonlinear calibration were solved by changing the internal standard and using a narrower mass window. With simazine, the use of a quadratic calibration curve was the best solution.

Numerical Analysis of Plume Characteristics and Liquid Circulation in Gas Injection Through a Porous Plug

  • Choi, Choeng-Ryul;Kim, Chang-Nyung
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.12
    • /
    • pp.1365-1375
    • /
    • 2000
  • Two phase flows have been numerically calculated to analyze plume characteristics and liquid circulation in gas injection through a porous plug. The Eulerian approach has been for formulation of both the continuous and dispersed phases. The turbulence in the liquid phase has been modeled using the standard $textsc{k}$-$\varepsilon$ turbulence model. The interphase friction coefficient has been calculated using correlations available in the literature. The turbulent dispersion of the phase has been modeled by the "dispersion Prand시 number". The predicted mean flows is compared well with the experimental data. The plume region area and the axial velocities are increased with the gas flow rate and with the decrease in the inlet area. The turbulent intensity also shows the same trend. Also, the space-averaged turbulent kinetic energy for various gas flow rates and inlet areas has been obtained. The results are of interest in the design and operation of a wide variety of materials and chemical processing operations.

  • PDF

Two-phase flow and heat transfer characteristics in a submerged gas injection system (잠겨진 가스분사장치에서의 2상 유동 및 열전달 특성)

  • 최청렬;김창녕
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.824-834
    • /
    • 1999
  • Characteristics of two-phase flow and heat transfer were numerically investigated in a submerged gas injection system when temperature of the injected gas was different from that of the liquid. The Eulerian approach was used for both the continuous and dispersed phases. The turbulence in the liquid phase was modeled using the standard $k-\varepsilon$$\varepsilon$ turbulence model. The interphase friction and heat transfer coefficient were calculated from the correlations available in the literature. The turbulent dispersion of the phases was modeled by a "dispersion Prandtl number". In the case with heat transfer where the temperature of the injected gas is higher than the mean liquid temperature, the axial and the radial velocities are lower in comparison with the case of homogeneous temperatures. The results in the present research are of interest in the design and operation of a wide variety of material and chemical processes.

  • PDF

Simulation of Energy Conversion Characteristics of OMACON LM-MHD Systems (OMACON형 LM-MHD 시스템에서의 에너지전환특성 시뮬레이션)

  • 김창녕
    • Journal of the Korea Society for Simulation
    • /
    • v.6 no.2
    • /
    • pp.1-14
    • /
    • 1997
  • The characteristics of the flow and energy conversion in OMACON liquid-metal MHD system are investigated. Numerical simulation of two-phase flow in the OMACON system without magnetic field was carried out by the Phoenics code and the energy conversion characteristics are studied in association with the fact that the mechanical energy loss at the nozzle of the OMACON system are to be converted into electrical energy. In this system, working fluid (gas) is injected through the mixer located at the bottom of the riser, and is mixed with hot liquid metal. Therefore in the riser two-phase flow is developed under the influence of the gravity. In this study, the interaction between the gas and liquid is considered by the use of IPSA(InterPhase Slip Algorithm) where standard drag coefficient has been used. It has been assumed that in the flow regime the liquid is continuous and the gas is dispersed. For the liquid and gas, the continuity equations, momentum equations and energy equations are solved respectively in association with void fraction in the flow field. In order to calculate the energy conversion efficiency, firstly the ratio of the mechanical energy loss of liquid metal flow at the nozzle to the input thermal energy is considered. Secondly flow pattern of liquid metal in the generator has been analyzed, and the characteristics of the conversion of the mechanical energy into the electrical energy has been investigated. For an representative case where Hartmann number is 540 and magnetic field is 0.35 T, the present analysis shows that the energy conversion efficiency is 0.653. This result is considered to be reasonable in comparison with published experimental results.

  • PDF

Speciation of Chromium in Water Samples with Homogeneous Liquid-Liquid Extraction and Determination by Flame Atomic Absorption Spectrometry

  • Abkenar, Shiva Dehghan;Hosseini, Morteza;Dahaghin, Zohreh;Salavati-Niasari, Masoud;Jamali, Mohammad Reza
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2813-2818
    • /
    • 2010
  • A novel method was developed for the speciation of chromium in natural water samples based on homogeneous liquid-liquid extraction and determination by flame atomic absorption spectrometry (FAAS). In this method, Cr(III) reacts with a new Schiff's base ligand to form the hydrophobic complex, which is subsequently entrapped in the sediment phase, whereas Cr(VI) remained in aqueous phase. The Cr(VI) assay is based on its reduction to Cr(III) by the addition of sodium sulfite to the sample solution. Thus, separation of Cr(III) and Cr(VI) could be realized. Homogeneous liquid-liquid extraction based on the pH-independent phase-separation process was investigated using a ternary solvent system (water-tetrabutylammonium ion ($TBA^+$)-chloroform) for the preconcentration of chromium. The phase separation phenomenon occurred by an ion-pair formation of TBA and perchlorate ion. Then sedimented phase was separated using a $100\;{\mu}L$ micro-syringe and diluted to 1.0 mL with ethanol. The sample was introduced into the flame by conventional aspiration. After the optimization of complexation and extraction conditions such as pH = 9.5, [ligand] = $1.0{\times}10^{-4}\;M$, [$TBA^+$] = $2.0{\times}10^{-2}\;M$, [$CHCl_3$] = $100.0\;{\mu}L$ and [$ClO_4$] = $2.0{\times}10{-2}\;M$, a preconcentration factor (Va/Vs) of 100 was obtained for only 10 mL of the sample. The relative standard deviation was 2.8% (n = 10). The limit of detection was sufficiently low and lie at ppb level. The proposed method was applied for the extraction and determination of chromium in natural water samples with satisfactory results.