• Title/Summary/Keyword: liquid recovery

Search Result 778, Processing Time 0.029 seconds

Study of spray characteristics according to the variation of swirl vane geometry for Fuel oil scrubber nozzles (연료유 스크러버 노즐의 스월베인 구조변화에 따른 분무특성의 수치해석적 연구)

  • Kim, In-Cheol;Lee, Kyung-Woo;Lee, Young-Ho
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.203-203
    • /
    • 2012
  • The Recovery facility, the scrubber is a collection device that injects liquid into the gas with the suspended particles using a spray nozzle. The liquid used is generally water. For the development of the design technology of a high efficiency scrubber, the spray characteristics according to the variation of the scrubber nozzle swirl vane was studied.

  • PDF

Simultaneous determination of bisphenol A, chlorophenols and alkylphenols by solid-phase extraction and HPLC

  • Lee, Taejoon;Park, Keun-Young;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.20-25
    • /
    • 2017
  • An analytical method for determining potential endocrine disruptors (bisphenol A, 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol, p-t-butylphenol, p-pentylphenol, p-hexylphenol, p-t-octylphenol, p-heptylphenol, nonylphenol) by solid-phase extraction (SPE) and High Perfomance Liquid Chromatography(HPLC) equipped with fluorescence and variable wavelength detector has been developed. The SPE process for sample concentration was performed on a commercially available Oasis HLB cartridge packed with polymeric sorbents. The effect of elution solvent and elution volume on the recoveries of the analytes were investigated with HPLC. Average recovery of >85% was achieved with 60mg sorbents using 5mL of methanol as elution solvent. Phenolic compounds in canned drinks, beverages and water samples were surveyed by this proposed method.

Separation of Lipases Using Reversed Micelles (역미셀을 이용한 리파아제의 분리)

  • 최평호;류희욱이태호장용근
    • KSBB Journal
    • /
    • v.6 no.4
    • /
    • pp.337-344
    • /
    • 1991
  • The liquid-liquid extraction of lipase A from Candide cylindracea and lipase B from porcine pancrease was carried out using reversed micellar organic solvents. Effects of various factors such as ionic strength, pH, and species and concentration of surfactant, on lipase solubilization were studied. A cationic surfactant cetyl-trimethyl ammonium bromide (CTAB) in isooctane/nhexanol(1:1) was found to be an effective solvent and its optimum concentration was 50 mM. KCl among various salts tested was the most effective and the efficiency of solubilization of lipase increased with decreasing the ionic strength of salts. The maximum activity and solubiliz ation of protein were obtained at pH 8. The stripping efficiency has a maximum value at pH 4 and increases with KCl concentration in the range of 0.2∼1.0 M. After the solubilization and stripping, the overall recovery efficiency of mass and specific activity of lipases was 62% and 66%, respectively.

  • PDF

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).

Determination of Liraglutide in Rat Plasma Using Selective Liquid Chromatography-Tandem Mass Spectrometry

  • Younah Kim;Hyoje Jo;Yelim Lee;Soo Yeon Kang;Sangkyu Lee
    • Mass Spectrometry Letters
    • /
    • v.14 no.4
    • /
    • pp.141-146
    • /
    • 2023
  • Liraglutide is a medication prescribed for the management of type 2 diabetes and chronic obesity. A simple, sensitive, and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative analysis of liraglutide in rat plasma. After a simple protein precipitation step, liraglutide was chromatographically separated using the ACQUITY Premier Peptide BEH C18 Column with mobile phases comprising 50% acetonitrile and 50% methanol, and water with 0.3% FA. Positive ion electrospray ionization in multiple reaction monitoring mode was used to achieve detection. Good linearity was observed in the 5-600 ng/mL concentration range (R2 > 0.99). Liraglutide had intra- and inter-day precision values of 2.13%-9.86% and 4.14%-8.36%, respectively. The accuracy ranged from -2.36% to 2.58%. The recovery and matrix effect were within acceptable limits. This selective LC-MS/MS method was used to study the pharmacokinetic properties of liraglutide after subcutaneous administration in rats.

Development of Cesium-selective Paramagnetic Core Inorganic Composite Agent for Water Decontamination (수질오염 제염을 위한 세슘 선택성 상자성 코어 무기복합제염제 개발)

  • Seong Pyo Hong;Bo-Sun Kang
    • Journal of Radiation Industry
    • /
    • v.18 no.2
    • /
    • pp.127-132
    • /
    • 2024
  • Large amounts of liquid radioactive waste or radioactive contaminated water could be produced during the treatment of radiation accidents or during the dismantling and decontamination process of nuclear power plants. Since most of the decontamination agents to date are difficult to recover after adsorption of radioactive isotopes, their use in open environments such as rivers, reservoirs, or oceans is limited. In this study, as a radioactive decontamination agent that can overcome the current limitations when used in an open environment, a paramagnetic core inorganic composite (PMCIC) decomposite agent with high selectivity to cesium ions was developed. PMCore was prepared by synthesizing paramagnetic iron oxide nanoparticles, and inorganic crystals such as metal-ferrocyanide were conjugated to the surface so that PMCore could be selective to cesium ions. The developed PMCIC could be easily recovered from the water by magnetism and could adsorb up to 94 μM of Cs atoms per 1 g of PMCIC.

Determination of Buprofezin Residues in Rice and Fruits Using HPLC with LC/MS Confirmation

  • Lee, Young-Deuk;Jang, Sang-Won
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.3
    • /
    • pp.247-256
    • /
    • 2010
  • A high-performance liquid chromatographic (HPLC) method was developed to determine buprofezin residues in hulled rice and fruits. The buprofezin residue was extracted with acetone and the extract was stepwise purified by liquid-liquid partition and Florisil column chromatography. For rice samples, acetonitrile/n-hexane partition was additionally employed to remove nonpolar lipids. Reversed phase HPLC using an octadecylsilyl column was successfully applied to separate buprofezin from sample co-extractives, as detected by ultraviolet absorption at 250 nm. Recovery experiment at the limit of quantitation validated that the proposed method could evidently determine the buprofezin residue at the level of 0.02 mg/kg. Mean recoveries from hulled rice, apple, pear, and persimmon samples fortified at three tenfold levels were in the range of 80.8~85.2%, 89.1~98.4%, 88.8~95.7% and 90.8~96.2%, respectively. Relative standard deviations of the analytical method were all less than 5%, irrespective of sample types. A selected-ion monitoring LC/mass spectrometry with positive electrospray ionization was also provided to sensitively confirm the suspected residue.

Review on the Analytical Methods and Ambient Concentrations of Organic Nitrogenous Compounds in the Atmosphere (대기 유기질소화합물의 분석방법 및 농도)

  • Choi, Na Rae;Kim, Yong Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.120-143
    • /
    • 2018
  • The analytical methods and their ambient levels of organic nitrogenous compounds such as nitrosamines, nitramines (nitroamines), imines, amides and nitro-polycyclic aromatic hydrocarbons (nitro-PAHs) in the atmosphere are summarized and discussed. Sampling for the analysis of organic nitrogenous compounds was mostly conducted using high volume air sampler. The direct liquid extraction (DLE) using sonification and the pressurized liquid extraction (PLE) using the accelerated solvent extraction (ASE) have been frequently employed for the extraction of organic nitrogenous compounds in the atmospheric samples. After extraction, clean-up via filtration and the solid phase extraction (SPE) and concentrations using nitrogen and rotary evaporator have been generally conducted but in some studies the clean-up and concentration steps have been omitted to prevent the loss of analyte and improve the recovery rate of the analytical procedure. Instrumental analysis was mainly carried out using gas chromatography (GC) or the high performance liquid chromatography (HPLC) coupled with the single quadrupole mass spectrometer or tandem mass spectrometer in the electron ionization (EI), positive chemical ionization (PCI) and negative chemical ionization (NCI) mode and analysis sensitivity of nitrosamines and nitramines were higher in NCI mode. Desirable sampling and analysis methods for analyzing particulate organic nitrogenous compounds are suggested.

Liquid Chromatography-Tandem Mass Spectrometry Analysis of Riboflavin in Beagle Dog Plasma for Pharmacokinetic Studies

  • Jeong, Hyeon Myeong;Shin, Beom Soo;Shin, Soyoung
    • Mass Spectrometry Letters
    • /
    • v.11 no.1
    • /
    • pp.10-14
    • /
    • 2020
  • Riboflavin is a water-soluble vitamin, which serves as a precursor to flavin mononucleotide and flavin adenine dinucleotide. This study aimed to develop a simple and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis for the quantification of riboflavin in the Beagle dog plasma. This method utilized simple protein precipitation with acetonitrile and 13C4, 15N2-riboflavin was used as an internal standard (IS). For chromatographic separation, a hydrophilic interaction liquid chromatography (HILIC) column was used with gradient elution. The mobile phase consisted of 0.1% (v/v) aqueous formic acid with 10 mM ammonium formate and acetonitrile with 0.1% (v/v) formic acid. Since riboflavin is an endogenous compound, 4% bovine serum albumin in phosphate buffered saline was used as a surrogate matrix to prepare the calibration curve. The quantification limit for riboflavin in the Beagle dog plasma was 5 ng/mL. The method was fully validated for its specificity, sensitivity, accuracy and precision, recovery, and stability according to the US FDA guidance. The developed LC-MS/MS method may be useful for the in vivo pharmacokinetic studies of riboflavin.

Simultaneous Determination of the Novel Neuroprotective Agent KR-31378 and its Metabolite KR-31612 Using High Performance Liquid Chromatography with Tandem Mass Spectrometry in Human Plasma

  • Kim, John;Ji, Hye-Young;Yoo, Sung-Eun;Kim, Sun-Ok;Lee, Dong-Ha;Lim, Hong;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.647-651
    • /
    • 2002
  • An LC/MS/MS method for the simultaneous determination of a neuroprotective agent for ischemia-reperfusion damage, KR-31378 and its N-acetyl metabolite KR-31612 in human plasma was developed. KR-31378, KR-31612 and the internal standard. KR-31543 were extracted from human plasma by liquid-liquid extraction. A reverse-phase HPLC separation was performed on Luna phenylhexyl column with the mixture of acetonitrile-5 mM ammonium formate (55:45, v/v) as mobile phase. The detection of analytes was performed using an electrospray ionization tandem mass spectrometry in the multiple reaction monitoring mode. The lower limits of quantification for KR-31378 and KR-31612 were 2.0 ng/ml. The method showed a satisfactory sensitivity, precision, accuracy, recovery and selectivity.