• Title/Summary/Keyword: liquid measurement

Search Result 1,119, Processing Time 0.03 seconds

모델에 의한 흡배관내 연료유동의 거동에 관한 실험염구 (An experimental study on the behavior of fuel flow in intake manifold by the model)

  • 박경석
    • 오토저널
    • /
    • 제5권3호
    • /
    • pp.33-44
    • /
    • 1983
  • This paper deals with the experimental study on the behavior of fuel (methanol) in intake manifold by using the basic apparatus which is manufactured the visible straight tube type model. In this study, the new device for liquid film thickness measurement and vaporization rate measurement are introduced to investigate the variation of liquid film thickness along the intake manifold and to observe the effect of vaporization of injected fuel. the results are summarized as follows: 1) The vaporization rate increases in proportion to decreasing of throttle valve angle and growing air fuel ratio. 2) The liquid film thickness along the intake manifold is mostly independent for the throttle valve angle in low air velocity and then affected in high air velocity, but the distribution of the liquid film thickness on circumferential position almost constant in the region of 300mm down stream from carburetor. 3) The mean liquid film thickness is 0.04 - 0.18mm in case of methanol in the region of air velocity Va = 12m/s - 55m/s and decreases with decreasing the throttle valve angle.

  • PDF

액막두께 측정방법을 이용한 스월 인젝터의 분무특성 연구 (Spray characteristics of swirl injector using liquid film thickness measurement)

  • 김성혁;김동준;김병선;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.251-255
    • /
    • 2005
  • 본 연구에서는 스월 인젝터의 기하학적 형상에 따른 분무특성 파악을 위해 액막두께 측정방법을 사용하였다. 액막두께 측정을 위해 특별히 제작된 인젝터를 사용하였으며, 백홀과 스월챔버 그리고 오리피스의 길이에 따른 분무특성을 확인하였다. 분무특성 파악을 위해 분사압에 따른 유량변화, 오리피스 하단의 액막두께와 분무각을 측정하였다.

  • PDF

직접분사식 가솔린엔진용 고압 스월분무의 액막두께 측정 및 해석 (Measurement and Analysis of Liquid Film Thickness of Pressure-Swirl Spray for Direct-Injection Gasoline-Engines)

  • 문석수;;오희창;배충식
    • 한국분무공학회지
    • /
    • 제12권4호
    • /
    • pp.211-219
    • /
    • 2007
  • The liquid film thickness inside a pressure-swirl nozzle was measured, and then the measured liquid film thickness was compared with the results from previous empirical equations. The liquid film inside the nozzle was visualized using extended transparent nozzles and a microscopic imaging system, and then the measurement error was evaluated using optical geometry analysis. The high injection pressures up to 7MPa were adopted to simulate the injection conditions of the direct-injection spark-ignition engines. The totally different two injectors with different fuels, nozzle lengths, nozzle diameters and swirlers were utilized to obtain the comprehensive equations. The results showed that the liquid film thickness very slightly decreased at high injection pressures and the empirical equations overestimated the effect of injection pressure. Most of empirical equations did not include the effect of nozzle length and swirler angle, although it caused significant change in liquid film thickness. A new empirical equation was suggested based on the experimental results with the effects of fuel properties, injection pressure, nozzle diameter, nozzle length and swirler angle.

  • PDF

광 최소/최대법을 이용한 IPS-LCD의 잔류 DC특성 연구 (A Study on Residual DC Characteristics in the in-plane Switching Liquid Crystal Display by Light Minimum/Maximum Method)

  • 김향율;한은주;서대식
    • 한국전기전자재료학회논문지
    • /
    • 제14권7호
    • /
    • pp.590-594
    • /
    • 2001
  • The residual DC properties in the in-plane switching (IPS) liquid crystal displays(LCDs) which have different concentrations of cynao NLCs and different resistivities of fluorine NLCs were studied. We also propose a new residual DC measurement method, named 'light minimum/maximum method'. We confirmed the precision of residual DC measurement by light minimum/maximum method compared with the flicker minimizing method and found that new measurement method of residual DC is more accurate than that of the conventional flicker minimizing method since the resolution level of measurements is in 0.1V.

  • PDF

인광입자(Sr,Mg)2SiO4:Eu2+를 이용한 액체의 온도장 측정에 관한 연구 (Study on Temperature Field Measurement of Fluid using Phophor Particle (Sr,Mg)2SiO4:Eu2+)

  • 송동진;이현창
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.59-65
    • /
    • 2019
  • Phosphor particles ((Sr,Mg)2 SiO4:Eu2+ were suspended in deionized water in quartz cuvette and used for measuring liquid temperature field by using two-color-ratio method. In the temperature range of 23~77℃, it showed the relative error from 2.4% to 4% and the temperature sensitivity of 0.65 %/℃ at 30℃ and 0.95 %/℃ at 77 ℃. This performance is comparable to measurement techniques using thermographic liquid crystal or laser induced fluorescence or other thermographic phosphor particle. Among investigated potential error sources, the particle number density affected the intensity ratio and the temperature, but the effect of laser fluence was not evident.

Measurement of Thermal Conductivity of Foods in Liquid and Solid Phase Using a Thermal Probe

  • Hong, Ji-Hyang;Han, Young-Joe;Chung, Jong-Hoon
    • Food Science and Biotechnology
    • /
    • 제14권3호
    • /
    • pp.334-339
    • /
    • 2005
  • An instrument using thermal probe method was designed to measure thermal conductivity of liquid and solid foods. Thermal conductivity probe was designed with diameter to length ratio of 100 and diameter of 0.51 mm to minimize axial flow effect on thermal conductivity measurement. Thermal conductivities of distilled/deionized water, glycerin, and beef frankfurter meat were measured at $20-80^{\circ}C$. Mean thermal conductivity values of water showed less than 2.0% difference from several reference values without using time correction factor or probe calibration constant. For glycerin, difference was less than 0.7% from reference values at $20-50^{\circ}C$. Mean values of thermal conductivity for beef frankfurter meat ranged from 0.389 to $0.350\;W/m{\cdot}K$ at $20-80^{\circ}C$.

레이저진동계를 사용한 동조액체댐퍼의 액체 진동 측정 (Measurement of Liquid Oscillation in Tuned Liquid Dampers using a Laser Doppler Vibrometer)

  • 신윤수;민경원;김준희
    • 한국전산구조공학회논문집
    • /
    • 제29권6호
    • /
    • pp.513-519
    • /
    • 2016
  • 본 논문에서는 기존 파고 측정 센서의 한계를 극복하기 위하여 레이저 장비 중 LDV를 이용하여 동조액체기둥감쇠기 안의 액체의 파고를 측정하는 방법을 제안하고 검증하였다. 비접촉 센서의 장점과 LDV가 속도와 변위를 측정하는 원리를 기술하였고 대상 물체가 액체인 경우에 요구되는 사항들에 대하여 실험적으로 파악하였다. 투명한 액체는 레이저 광선을 대부분 투과시켜 LDV에 되돌아오는 광량이 부족해 측정이 불가능함을 확인하였고 이를 증가시키기 위해 염료를 혼합하였다. 이때, 염료의 색에 따라 광량에 차이가 발생함을 확인하여 LDV에 사용된 레이저 광선의 파장과 연관된 결과를 도출하였다. 염료를 혼합한 후 광량이 충분한 경우에도 발생하는 데이터의 오차를 제거하기 위해 염료의 농도를 변화시키며 그에 따른 데이터의 정확도를 파악하였다. 결과적으로 모든 가시광선의 빛을 반사시키는 흰색의 염료를 충분한 농도로 혼합하였을 때 LDV를 이용한 TLCD의 파고 측정의 실험적인 결과가 용량식 파고계와 일치함을 확인하였다.

Liquid crystal-surface interactions studied by light scattering

  • Copic, Martin;Vilfan, Mojca
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.1711-1714
    • /
    • 2006
  • Anchoring energy of liquid crystals on solid substrates is a key parameter in liquid crystal technology. A nonperturbative method of its measurement by dynamic light scattering on thermal orientational fluctuations is presented, The ratio of the zenithal and azimuthal anchoring coefficients is shown to be equal to the ratio of the orientational elastic constants.

  • PDF

감온액정을 이용한 층류유동의 온도장에 관한 실험적 연구 (An Experimental Study on Laminar Flow Temperature Using Thermo-sensitive Liquid Crystal)

  • 장태현
    • 한국산업융합학회 논문집
    • /
    • 제6권4호
    • /
    • pp.373-378
    • /
    • 2003
  • An experimental investigation was performed to study the characteristics of laminar water flow in a horizontal circular tube by using liquid crystal. A simultaneous measurement technique has been employed to measure the temperature field in a two-dimensional cross section of fluid flow. This study found the temperature distribution for Re =900~1,500 along longitudinal sections and the results appear to be physically reasonable. To determine some characteristics of the laminar flow, 2D PIV technique is employed for temperature measurement and liquid crystal is used for heat transfer experiments in water. The experimental rig was manufactured from an acryle tube. The test tube diameter of 25mm, and a length of 1200mm. The used algorithm is the gray level cross-correlation method by using Kimura et al. in 1986.

  • PDF

Simple Technique for Measurement of Complex Permittivity and Detection of Small Permittivity Change Using Partially Open Cavity

  • Park, Sangbok;Chung, Young-Seek;Cheon, Changyul
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.268-272
    • /
    • 2014
  • This letter presents a measurement methodology of the complex permittivity of liquid using a partially open cavity in narrow band. The partially open cavity (POC) can measure dielectric small changes caused by the temperature variation of the liquid inside the cavity as well. Using the resonance frequency and unloaded quality factor of the proposed POC, the complex permittivity is evaluated. The apertures on the walls of the cavity are designed to circulate the liquid inside to outside of the POC and located at the corner area of the cavity to minimize the disturbance of field distribution at the dominant mode. The results measured by the proposed POC were compared with those by the conventional open-ended probe and Cole-Cole equation. The POC showed better performance in measuring small dielectric constant changes than the open-ended probe.