• 제목/요약/키워드: liquid filter

검색결과 257건 처리시간 0.025초

증발 조건에서 직분식 가솔린 분무의 증기 농도의 분포 (Distribution of the Concentration of Fuel Vapor in DI Gasoline Sprays Under Evaporation Condition)

  • 황순철;최동석;차건종;김덕줄
    • 한국분무공학회지
    • /
    • 제4권4호
    • /
    • pp.1-8
    • /
    • 1999
  • The concentration and spatial distribution of vapor phases in DI (Direct Injection) gasoline spray were measured quantitatively by exciplex fluorescence method. Fluorobenzene and DEMA (diethylmethylamine) in a solution of hexane were used as the exciplex-forming dopants. The fluorescence intensity of vapor phase were obtained by ICCD camera with the appropriate filter The relationship between fluorescence intensity and vapor concentration was induced fer the purpose of a quantitative analysis. The 2-D vapor/liquid images of fuel spray were captured under the evaporation condition, and the spatial distribution of vapor concentration was obtained. The spatial distribution of liquid phase had hollow-cone shape. And the vapor phase was widely distributed in the whole spray. The behavior of vapor phase was significantly affected by second flow such as entrainment, vortex, while that of liquid phase was scarcely affected.

  • PDF

Solvent-localized in-situ NMR Monitoring by Intermolecular Single-quantum Coherence Study

  • Cha, Jin Wook;Park, Sunghyouk
    • 한국자기공명학회논문지
    • /
    • 제24권4호
    • /
    • pp.96-103
    • /
    • 2020
  • A new NMR method to monitor solvent-localized NMR signals in the two-phase liquid system is suggested. This method based on intermolecular single-quantum coherence (iSQC). Here, we exploited the feature of the local action of distant dipolar field (DDF) effect in order to filter out specific NMR signals dissolved in different solvents. This solvent specific iSQC spectroscopy was carried out on a model two-phase liquid system (D-glucose in water/palmitic acid in chloroform), and showed solvent-localized NMR signals. We believe our approaches might be useful in metabolic analysis such as two-phase liquid extraction scheme for labile chemical species.

FT-NIR SPECTROSCOPY FOR QUALITY AND PROCESS CONTROL IN DEPTH FILTER SHEETS PRODUCTION

  • Jansen, Christoph;Ebert, Jurgen
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3122-3122
    • /
    • 2001
  • Documented quality control plays a vital role I the production of technical “Depth filter” sheets used in industries such as Beverage and pharmaceutical. Depth filter sheets which can be up to several millimeters thick are stacker in plate and frame filter systems. They are the core of stainless steel filter systems which can be up to several meters high. FT-NIR Spectroscopy has many potential applications in the whole production line of filter sheets. Raw materials such as different types of cellulose pads, white powdery fillers (e.g. Kieelgur, Perlite) or liquid chemicals such as wet-strength agents we, with the help of NIR, easy to identify. NIR can also determine physical parameters such as particle size, essential for the filtration behavior. FT-NIR can be used for the quality parameters of the final product. Moisture and permeability can be determined, and with the help of the speed of this NIR method it is possible to correct possible faults quickly in the production process. Waste production can be minimized which is good for both the product profitability and the environment. Further tests have shown that it is also possible to use NIR on-line in the production area, to check the concentrations and the homogeneity of the paper suspension consisting of cellulose fibres, fillers and additives.

  • PDF

슬러리 양돈분뇨의 최적 고액분리 방안 연구 (A Practical Study on the Solid-Liquid Separation of the Swine Wastewater from Slurry Feedlot)

  • 박성균;최재길;정윤진
    • 유기물자원화
    • /
    • 제8권2호
    • /
    • pp.60-70
    • /
    • 2000
  • 현재 국내에서 처리에 어려움을 겪고 있으며 사회적으로 문제가 되고 있는 양돈 분뇨의 처리중 생물학적 처리를 위한 전처리 공정의 일환으로 비육돈 슬러리 돈사에서 발생하는 분뇨를 대상으로 고액분리에 관한 연구를 수행하였다. 최적의 고액 분리를 위하여 적정 응집제 선정 및 첨가량을 도출하였으며, 현장 규모의 고액 분리 장치를 통하여 규모별 최적 고액 분리 공정을 도출하였다. 이 결과 탈수성 개량을 위한 적정 응집제로는 Polyarcylamide 계열의 양이온 고분자 응집제인 E-851이 적합하였으며, 단위 고형물당 0.24~0.6%가 요구되었다. 본 연구에서 검토된 공정으로는 Mesh Screen, Drum Screen, Cyclone Drum Filter, Screw Press, 고속 Screw Decanter, 저속 Screw Decanter 및 DAF 공정을 조합하여 검토하였다. 그 결과 최적 공정으로는 중 소규모의 1차 고액 분리 공정으로는 Screw Press(응집제 첨가)와 대규모 및 공공처리장 규모에서는 저속 Screw Decanter(응집제 첨가)가 적정 공정으로 도출되었으며 2차 처리 공정으로는 가압부상조가 가장 안정적인 것으로 나타났다. 한편 고액 분리 유무에 따라 수분조절제 및 유기물 부하량 감소는 각각 94.8, 84.7%로 나타났으며 슬러리 양돈분뇨의 정화방안으로는 고액분리가 반드시 필요한 것으로 나타났다.

  • PDF

Simplified HPLC Method for the Determination of Pseudoephedrine Hydrochloride from Allegra D Tablet

  • Park, Moon-Hee;Shin, In-Chul
    • Biomolecules & Therapeutics
    • /
    • 제15권2호
    • /
    • pp.123-126
    • /
    • 2007
  • A sensitive, simple and highly selective liquid chromatography method of determination for extraction of pseudoephedrine hydrochloride from Allegra D tablet was developed. The chief benefit of the present method is the minimal sample preparation, as the procedure is only filtering through pore syringe filter. Two drugs (pseudoephedrine hydrochloride, fexofenadine) were separated on a C$_{18}$ column and analyzed by high performance liquid chromatography (HPLC). The method had a chromatographic run time of 8.0 min. 1 ml of pseudoephedrine hydrochloride solution (1 mg/ml) was filtered through 0.22 um pore syringe filter. 50 ul of filtering solution was injected to HPLC pump and we knew the retention time (1.85 min) of separating of pseudoephedrine hydrochloride using UV detector at 280 nm. We used C$_{18}$ column (4.6 mm${\times}$250 mm), mobile phase solution (<0.05 mol/L NaH$_2$PO$_4$, 2 ml/L H$_3$PO$_4$>/CH$_3$CN / sodium dodesyl sulfate = 60 ml / 40 ml / 1 g). We separated psedoephedrine hydrochloride at run time of 1.85 min from Allegra D tablet solution (1 mg/ml) filtered through 0.22 um pore syringe filter using UV detector at 280 nm. Flow rate was set at 1.0 ml/min and the column temperature was set at 40$^{\circ}C$. Psedoephedrine hydrochloride solution (1 mg/ml) separated from Allegra D tablet was filtered through 0.22 um pore syringe filter and injected 50 ul. We confirmed the peak of psedoephedrine hydrochloride at same retention time and the separating solution was freeze-dried. In conclusion, A simple isocratic reverse-phase HPLC method has been developed that provides excellent separation of pseudoephedrine from Allegra D tablet.

대형선박의 액체 탱크용 수위 모니터링 센서 시스템 연구 (A Study on the Tank Liquid-Level Monitoring Sensor Systems for Large Scaled Vessels)

  • 손경락;김진욱;조석제;심준환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권2호
    • /
    • pp.330-335
    • /
    • 2009
  • A fiber-optic liquid level sensor based on bending cantilever beam has been proposed. A fiber Bragg grating(FBG) embedded in the cantilever beam is used to sensing elements. The basic concept is elongation and constriction of the FBG corresponding to the liquid level variation. The best FBG position on the cantilever for obtaining the high sensitivity was 4 cm from the fixing point. When the liquid level moves up and down vertically, the Bragg wavelength is linearly shifted. But, the wavelength sensitivity of the FBG installed on the upper side of cantilever was four times better than that of the FBG equipped in the lateral side due to the difference of unit strain applied to the FBG. Intensity demodulation using the low-cost edge filter is used to interrogate the Bragg wavelength through converting the wavelength signals into the optical intensity ones. Experiment results show that the electrical output is exponentially proportional to the liquid level. But, it should be overcome for applying to the ships.

대기오염제어를 위한 생물살수여과법에서 물질전달계수 실험평가방법에 관한 연구 (Experimental Evaluation Method of Mass Transfer Coefficient on Biotrickling Filtration for Air Pollution Control)

  • 원양수;조완근
    • Korean Chemical Engineering Research
    • /
    • 제53권4호
    • /
    • pp.482-488
    • /
    • 2015
  • 생물학적 방법에 의한 대기오염물질 처리는 기존의 처리방법을 대체할 수 있는 방법으로 각광을 받고 있다. 생물학적 처리방법은 유기화합물 또는 악취가 포함된 저농도 고유량의 공기를 처리하는데 효과적이다. 생물살수여과법을 이용한 대기오염물질 제거에서 물질전달 연구는 공정 최적화를 위해 매우 중요한 부분이다. 본 연구에서는 3상의 물질전달이 이루어지는 생물살수여과법에서 기체/액체(살수액), 기체/고체(미생물), 액체/고체 물질전달 실험방법 개발과 물질전달 현상을 고찰하였다. 또한 본 연구에서는 각 상간에서 물질전달에 영향을 미치는 인자로 동적적체량, 기/액 유량비, 반응기내 미생물량, 살수액 순환량 등에 대해 고찰하였다.

나노구체의 자기조립 성질과 표면장력을 이용한 나노유체필터 및 나노포어 마이크로믹서 (Development of the Nanofluidic Filter and Nanopore Micromixer Using Self-Assembly of Nano-Spheres and Surface Tension)

  • 서영호;최두선
    • 대한기계학회논문집A
    • /
    • 제31권9호
    • /
    • pp.910-914
    • /
    • 2007
  • We present a simple and an inexpensive method for the fabrication of a nano-fluidic filter and a nano-pore micromixer using self-assembly of nano-spheres and surface tension. Colloid-plug was formed by surface tension of liquid in a microchannel to fabricate nanofluidic filter. When colloid is evaporated, nano-spheres in a colloid are orderly stacked by a capillary force. Orderly stacked nano-spheres form 3-D nano-mesh which can be used as a mesh structure of a fluidic filter. We used silica nano-sphere whose diameter is $567{\pm}85nm$, and silicon micro-channel of $50{\mu}m$-diameter. Fabricated nano-fluidic filter in a micro-channel has median pore diameter of 158nm which was in agreement with expected diameter of the nano-pore of $128{\pm}19nm$. A nano-pore micromixer consists of $200\;{\mu}m-wide,\;100\;{\mu}m-deep$ micro-channel and self-assembled nano-spheres. In the nano-pore micromixer, two different fluids had no sooner met together than two fluids begin to mix at wide region. From the experimental study, we completely apply self-assembly of nano-spheres to nano-fluidic devices.

담배 Mainstream Smoke중 Semi-volatile 화합물 연구 (Study of the Semi-volatile Components in Cigarette Mainstream Smoke)

  • 김정열;신창호;김종열;김영호;이근회
    • 한국연초학회지
    • /
    • 제20권1호
    • /
    • pp.115-123
    • /
    • 1998
  • The semi-volatile fraction of cigarette mainstream smoke contains the most important aroma and taste that enhance smoke flavor. The components in mainstream smoke were analysed for commercially available cigarettes. To compare the semi-volatile components delivered from mainstream smoke of domestic cigarette with imported cigarette, we analyzed three types of filter cigarettes such as cellulose acetate mono filter, carbon dual filter and slim filter cigarette. Mainstream smoke was collected with a combination of Cambridge filter pad and liquid trap containing a small amount of acetone cooled by dry ice-methanol. We have identified 43 components from mainstream smoke by GC and GC/MS and found that benzene, toluene, 4-hydroxy-4-methyl-2-pentanone, 5-methyl-2-furaldehyde, acetic acids nicotine and triacetin were the main peaks in mainstream smoke. Also we have compared the relative amounts of semi-volatile compounds delivered from the domestic and imported cigarettes with three different filters. From the results of this study, the relative amounts of limonene, acetic acid, 5-methyl-Lfuraldehyde delivered from the imported cigarettes were generally higher than those of the domestic one's.

  • PDF

A full-color anaglyph three-dimensional display system using active color filter glasses

  • Kim, Jong-Hyun;Kim, Young-Hoon;Hong, Ji-Soo;Park, Gil-Bae;Hong, Kee-Hoon;Min, Sung-Wook;Lee, Byoung-Ho
    • Journal of Information Display
    • /
    • 제12권1호
    • /
    • pp.37-41
    • /
    • 2011
  • Presented herein is a novel stereoscopic three-dimensional (3D) display system with active color filter glasses. This system provides full-color 3D images by applying the time-multiplexing technique on the original anaglyph method. By switching between the opposite anaglyph statuses, a full-color anaglyph is presented. A liquid crystal panel from a 3D monitor serves as an active color filter operating at 120 Hz. A display panel and a color filter are connected to one graphic card as a dual-link system, for synchronization. To test the quality of this system, a left/right-eye image separation test and an experiment with stereoscopic images were carried out. Although there was some crosstalk and blur, the system, as expected, provided full-color 3D display. This system overcomes a monochromatic 3D image, which is the major weakness of the original anaglyph system.