• 제목/요약/키워드: liquid extraction

검색결과 1,065건 처리시간 0.024초

개방형 왕복 다공판 추출탑을 이용한 액막법에 의한 폐수중 Cr(Vl)의 추출 (Extraction of Chromium (Vl) Son in Waste Water through the Liquid Surfactant Membrane with Open-Type Perforated Reciprocating-Plate Column)

  • 우인성;강현춘;안형환
    • 한국안전학회지
    • /
    • 제8권2호
    • /
    • pp.44-50
    • /
    • 1993
  • The objective of this study was to investigate the extraction of chromium(Vl) ion in waste water through the liquid surfactant membrane with open-type Perforated Reciprocating-Plate Column. Extraction experiments were conducted to measure the effect of flow characteristics of continuous and dispersed phase and stroke velocity, sodium hydroxide concentraction in internal aqueous phase, sulfuric acid concentraction in outer phase, and residence time distribution and measured extraction velocity. The result of experiments showed that extraction velocity of chromium ion was maximum when stroke velocity was 180 1/min and dispersion phase velocity was 30m11min, continuous phase velocity was 20m1/min. Extraction velocity of chromium ion increased with increasing difference of hydrogen ion concentraction of dispersion and continuous phase and column stage decreased.

  • PDF

전처리 방법에 따른 커피원두 중 polycyclic aromatic hydrocarbons 함량 분석 (Analysis of Polycyclic Aromatic Hydrocarbon Content in Coffee Beans with Different Preparation Method)

  • 남혜정;서일원;신한승
    • 한국식품과학회지
    • /
    • 제41권2호
    • /
    • pp.157-161
    • /
    • 2009
  • 원두커피의 PAHs 분석을 위한 시료 전처리는 Soxhlet 추출법과 액/액 추출법 두 가지로 하였다. 두 방법의 간단한 모식도는 Fig. 2을 통해 나타내었다. Soxhlet 추출법을 이용하여 추출한 후 비누화시켜 SPE cartridge로 silica cartridge를 사용하여 효과적으로 정제하였으며, 액/액 추출법은 먼저 비누화를 시킨 후 n-hexane을 이용하여 추출하고 florisil cartridge로 clean up 시킨 후 각각 HPLC-FLD를 사용하여 분석하였다. 이러한 두 가지 방법으로 진행된 실험의 결과 90% 이상의 회수율을 보인 것은 액/액 추출법의 B[a]A, Chrys이었고, 80% 이상의 회수율을 보인 것은 액/액 추출법의 B[b]F, B[k]F, B[a]P, DB[a,h]A과 Soxhlet 추출법의 B[a]A, Chrys으로 나타났으며, 그 외에는 약 70% 정도의 회수율을 나타내었다. 7종의 총 PAHs 회수율은 각각 Soxhlet 추출법은 74.25%이고 액/액 추출법 77.08%로 많은 차이를 보이진 않았지만 액/액 추출법이 더 높은 회수율을 나타내었다. 두 방법 모두에서 Chrys의 회수율이 가장 높았으며, 두 가지 방법을 비교하여 실험한 결과 많은 차이를 보이지는 않았지만 Soxhlet 추출법보다 액/액 추출법이 전처리에 소비되는 시간을 줄일 수 있었으며 또한 액/액 추출법에서 표준물질의 회수율도 높게 나타났다.

Liquid Chromatography-Solid Phase Extraction-NMR (LC-SPE-NMR) Analysis of Liquid Crystalline Mixtures

  • Park, Gregory Hyung-Jin;Park, Ae-Na;Rho, Kyung-Rae;Shin, Jong-Ho;Kim, Yeong-Jeon;Jo, Sung-Chan;Oh, Weon-Sik
    • 한국자기공명학회논문지
    • /
    • 제15권1호
    • /
    • pp.14-24
    • /
    • 2011
  • We have performed Liquid Chromatography-Solid Phase Extraction-NMR (LC-SPE-NMR) analysis for liquid crystalline mixture and elucidated the structures of selected components by NMR spectra. Combining the results of one-dimensional 1H experiments as well as homonuclear and heteronuclear two-dimensional experiments, we could analyze the molecular structure of the liquid crystal singles whose structure had not been interpretable by mass spectrometry alone.

SPE법에 의한 음료수중 농약성분 (Pesticide Analysis in Drinking Water by SPE Method)

  • 김형석
    • 환경위생공학
    • /
    • 제10권2호
    • /
    • pp.59-66
    • /
    • 1995
  • According to the population increase and industrialization, the drinking water source, Han River and other sources, are contaminated by industrial wastewater, domestic sewage, and agricultural discharges. Among the contaminants, and toxic substances, pesticides is most interesting items (or human health Our drinking water has some problems of THMs, Fe, odor, etc., $o many people use groundwater or bottled water. But sometimes there are many reports about groundwater contamination owing to the agricultural chemicals, waste disposal, industrial wastewater. In America, there are about 45,000 groundwave supply company and in korea about 20% of total population are using groundwave as drinking water source. In America, studies about SEE is increasing Instead of liquid- liquid extraction method, because of many advantages of SEE methods. Author tried to investigate SPE methods in the spiked water samples to compare with liquid- liquid extraction method and got the following results. The amount of organic solvents which are used In SPE method is less than 1/10 compared with liquid- liquid method, the analytical duration time is shortened, and the ethyl acetate was good fluent among several organic solvents.

  • PDF

Identification of Nandrolone and its Metabolite 5α-Estran-3β, 17α-Diol in Horse Urine after Chemical Derivatization by Liquid Chromatography Tandem Mass Spectrometry

  • Dubey, Saurabh;Beotra, Alka
    • Mass Spectrometry Letters
    • /
    • 제8권4호
    • /
    • pp.90-97
    • /
    • 2017
  • Androgenic anabolic steroids (AASs) are synthetic derivatives of testosterone with a common structure containing cyclopentanoperhydrophenanthrene nucleus. Their use enhances the muscle building capacity and is beneficial during performance. The AASs are one of the most abused group of substances in horse doping. Liquid chromatography tandem mass spectrometry ($LC/MS^n$) has been successfully applied to the detection of anabolic steroids in biological samples. However, the saturated hydroxysteroids viz: nandrolone, $5{\alpha}-estrane-3{\beta}$, $17{\alpha}-diol$ exhibit lower detection responses in electrospray ionisation (ESI) because of their poor ionisation efficiency. To overcome this limitation pre-column chemical derivatization has been introduced to enhance their detection responses in $LC-ESI-MS^n$ analysis. The aim of present study was to develop a sensitive method for identification and confirmation of nandrolone and its metabolite in horse urine incorporating pre-column derivatization using picolinic acid. The method consists of extraction of targeted steroid conjugates by solid phase extraction (SPE). The eluted steroid conjugates were hydrolysed by methanolysis and free steroids were recovered with liquid-liquid extraction. The resulting steroids were derivatized to form picolinoyl esters and identification was done using LC-ESI-MS/MS in positive ionization mode. The picolinated steroid adduct enhanced the detection levels in comparison to underivatized steroids.

Determination of Cholesterol in Milk and Dairy Products by High-Performance Liquid Chromatography

  • Oh, H.I.;Shin, T.S.;Chang, E.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권10호
    • /
    • pp.1465-1469
    • /
    • 2001
  • A sensitive high-performance liquid chromatographic method was developed to determine the content of cholesterol in milk and dairy products. To optimize separation of cholesterol, mobile phases including acetonitrile:2-propanol (8:1, v/v), acetonitrile:methanol (3:1, v/v), and acetonitrile:methanoI:2-propanol (7:3: I, v/v/v) were compared. Acetonitrile/methanol/2-propanol was superior to the other mobile phase systems for separating cholesterol. Liquid-liquid extraction (LLE) of cholesterol was simplified using a non-polar solvent, hexane, to remove interfering compounds, and had an excellent recovery $(100{\pm}1.0%)$ of cholesterol. A solid phase extraction (SPE) method using Sep-pak $C_{18}$ was developed and compared with LLE. The SPE method was rapid and highly reproducible. Both extraction methods were useful when used in combination with saponification of esterified cholesterol to facilitate total cholesterol determination. The detection limit of cholesterol was $0.01{\mu}g$. The newly developed HPLC method was rapid, simple, and accurate, and has advantages over the many methods commonly used.

이온성 액체를 이용한 바이오매스 추출에 의해 얻어진 추출물의 건조 방법 (Method for Drying of Crude Extract Obtained by Biomass Extraction Using an Ionic Liquid)

  • 김슬기;김진현
    • Korean Chemical Engineering Research
    • /
    • 제54권3호
    • /
    • pp.374-379
    • /
    • 2016
  • 이온성 액체를 보조용매로 이용할 경우 바이오매스로부터 파클리탁셀의 추출 효율은 획기적으로 개선되지만 잔류 이온성 액체로 후속 농축 및 건조에 많은 어려움이 따른다. 따라서 본 연구에서는 공정 효율 향상을 위하여 이온성 액체를 이용한 바이오매스 추출물을 효과적으로 건조할 수 있는 새로운 방법을 개발하였다. 추출물을 물로 전처리하고 추가적으로 세척함으로써 잔류 이온성 액체 제거를 통해 효과적으로 건조할 수 있었다. 물 전처리을 위한 최적의 시료/물 비, 혼합시간 및 추가세척을 위한 최적의 시료/물 비는 각각 1:70 (w/v), 4분, 1:100 (w/v)이었다. 또한 진공 건조보다 마이크로웨이브를 이용한 건조의 경우 건조시간을 9배 정도 단축 가능하여 공정 효율이 획기적으로 개선될 것으로 판단된다.

Development of Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop for the Sensitive Determination of Trace Copper in Water and Beverage Samples by Flame Atomic Absorption Spectrometry

  • Wu, Chunxia;Zhao, Bin;Li, Yingli;Wu, Qiuhua;Wang, Chun;Wang, Zhi
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.829-835
    • /
    • 2011
  • A dispersive liquid-liquid microextraction based on solidification of floating organic droplet (DLLME-SFO) has been developed as a new approach for the extraction of trace copper in water and beverage samples followed by the determination with flame atomic absorption spectrometry. In the DLLME-SFO, 8-hydroxy quinoline, 1-dodecanol, and methanol were used as chelating agent, extraction solvent and dispersive solvent, respectively. The experimental parameters related to the DLLME-SFO such as the type and volume of the extraction and dispersive solvent, extraction time, sample volume, the concentration of chelating agent and salt addition were investigated and optimized. Under the optimum conditions, the enrichment factor for copper was 122. The method was linear in the range from 0.5 to $300\;ng\;mL^{-1}$ of copper in the samples with a correlation coefficient (r) of 0.9996 and a limit of detection of $0.1\;ng\;mL^{-1}$. The method was applied to the determination of copper in water and beverage samples. The recoveries for the spiked water and beverage samples at the copper concentration levels of 5.0 and $10.0\;ng\;mL^{-1}$ were in the range between 92.0% and 108.0%. The relative standard deviations (RSD) varied from 3.0% to 5.6%.

Predispersed Solvent Extraction of Succinic Acid Aqueous Solution by Colloidal Liquid Aphrons in Column

  • Kim Bong Seock;Hong Yeon Ki;Huh Yun Suk;Hong Won Hi
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제9권6호
    • /
    • pp.454-458
    • /
    • 2004
  • A study of the POSE (predispersed solvent extraction) for succinic acid by colloidalliq­uid aphrons was conducted. The organic phase contaning TOA (tri-n-octylamine) and 1-octanol permits a selective extraction of succinic acid from its aqueous solution. There was no difference of the extractability of POSE and that of conventional mixer-settler type extraction. Taking into account the no mechanical mixing in POSE, it was concluded that the POSE process is more adaptive than the conventional mixer-settler type extraction process. From mass transfer analysis at the various concentration of TOA in counter-current continuous operation, the concentration of TOA had no influence on the mass transfer coefficient. The loading values in continuous POSE were almost same as those in batch operation.

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).