• Title/Summary/Keyword: liquid effluent

Search Result 120, Processing Time 0.045 seconds

A Scheme on Reduction of NPP Liquid Effluent Activity

  • Kim, Wi-Soo;Yang, Yang-Hee;Kim, Hee-Guen
    • Nuclear Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.9-21
    • /
    • 2002
  • Recently each domestic NPP has achieved zero release in liquid effluent activity. However, when looking back past experiences in world nuclear power operation, it is thought that another maximum activity reduction in the released liquid effluent just prior to falling it into environment, if possible, will bring a good effect in PA viewpoint. As the intent of applying the safety concept of diversity to conducting the above activity reduction measure, a scheme passing that effluent through the Deposition Bed just before discharging it into ocean environment was divised. Both Zeolite and "the mixed "Anthracite-sand" were derived as the main activity adsorption medium used in the Deposition Bed, and the schematic drawings of this Bed were presented.

Estimation of Cattle Wastewater Treatment using Singang Advance Biology Reactor (SAB) (SAB 고율미생물반응기를 이용한 축산폐수처리의 성능 평가)

  • Lim, Bongsu;Kim, Doyoung;Park, Sungsoon
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.5
    • /
    • pp.727-734
    • /
    • 2009
  • This study was carried out to evaluate the high rate biological reactor such as lab scale reactor before the application in site, and to get the basic data for possibility using liquid fertilizer with the effluent from biological reactor when the centrifugal machine was applied. The total volume of this reactor in 6 L, in composted of anoxic reactor (2 L), aerobic reactor (2 L), and nitification reactor (2 L). BOD removal efficiency rates when centrifugal machine was applied after effluent from biological reactor are over than 95%. This biological reactor was required post process to satisfy the effluent standards, and was need centrifugal machine to control the washout of microbes in the reactor. T-N removal efficiency rate in HRT 24 hr with centrifugation is 80.0%, and it is desirable to operate less than $1.3kgN/m^3{\cdot}d$ for 70% of T-N removal efficiency rate. T-P removal efficiency rate in HRT 24 hr is 68.2%, and become higher 71.3% after centrifugation. Considering in the 28.6% T-N removal efficiency rate, the nitrogen contents of the effluent from reactor is 0.34% to satisfy the liquid fertilizer.

Performance Analysis of 1MW Organic Rankine Cycle with Liquid-Vapor Ejector using Effluent from Power Plant (화력발전소 폐열에 따른 작동유체별 액-증기 이젝터를 적용한 1MW급 ORC의 성능 분석)

  • Kim, Hyeon-Uk;Yoon, Jung-In;Son, Chang-Hyo
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.120-125
    • /
    • 2014
  • In this paper, suitable working fluid of 1MW Organic Rankine Cycle(ORC) with liquid-vapor ejector using effluent from power plant is selected. The results of comparison performance of 5 refrigerants are as follows; R600a, R134a, R1270, R236fa, R235fa. The operating parameters considered in this study include the condensation capacity evaporation capacity and efficiency. As a result of comparison of basic ORC system and with liquid-vapor ejector, with ORC system presents the higher system efficiency since the ejector makes the turbine outlet pressure lower than condensation pressure through its pressure recovery. Also, this ejector ORC system is advantageous in miniaturizing the size of components owing to decrease of evaporation capacity and condensation capacity.

Condenser cooling system & effluent disposal system for steam-electric power plants: Improved techniques

  • Sankar, D.;Balachandar, M.;Anbuvanan, T.;Rajagopal, S.;Thankarathi, T.;Deepa, N.
    • Membrane and Water Treatment
    • /
    • v.8 no.4
    • /
    • pp.355-367
    • /
    • 2017
  • In India, the current operation of condenser cooling system & effluent disposal system in existing power plants aims to reduce drawal of seawater and to achieve Zero Liquid Discharge to meet the demands of statutory requirements, water scarcity and ecological system. Particularly in the Steam-Electric power plants, condenser cooling system adopts Once through cooling (OTC) system which requires more drawal of seawater and effluent disposal system adopts sea outfall system which discharges hot water into sea. This paper presents an overview of closed-loop technology for condenser cooling system and to achieve Zero Liquid Discharge plant in Steam-Electric power plants making it lesser drawal of seawater and complete elimination of hot water discharges into sea. The closed-loop technology for condenser cooling system reduces the drawal of seawater by 92% and Zero Liquid Discharge plant eliminates the hot water discharges into sea by 100%. Further, the proposed modification generates revenue out of selling potable water and ZLD free flowing solids at INR 81,97,20,000 per annum (considering INR 60/Cu.m, 330 days/year and 90% availability) and INR 23,760 per annum (considering INR 100/Ton, 330 days/year and 90% availability) respectively. This proposed modification costs INR 870,00,00,000 with payback period of less than 11 years. The conventional technology can be replaced with this proposed technique in the existing and upcoming power plants.

Calculation of Energy Dependence of Calibration Constants in the Continuous Radioactive Effluent Monitors (연속방사능(連續放射能) 측정감시기(測定監視器)에서 교정상수(較正常數)의 에너지의존성(依存性) 계산(計算))

  • Lee, Soo-Yong;Yook, Chong-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.6 no.1
    • /
    • pp.41-44
    • /
    • 1981
  • A method is presented by which precise evaluation of radioactive concentrations in liquid or gaseous effluent released from large nuclear facilities is possible. Calculations have been made of the calibration constants at different energies for a commonly used liquid and gaseous effluent monitors as well. It is expected that the method could be applicable to the particular monitors with different geometrical configuration with simple modifications.

  • PDF

Numerical Simulation for Effluent Transport According to Change in Depth of Marine Outfall in Masan Bay Using a Particle Tracking Model (입자추적모델을 이용한 마산만 해중방류구 수심 변화에 따른 방류수 거동 수치모의)

  • Kim, Jin Ho;Jung, Woo sung;Kim, Dong-Myung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.55 no.6
    • /
    • pp.954-959
    • /
    • 2022
  • Marine outfalls are used to discharge treated liquid effluents to the environment. An efficiently designed, constructed and operated marine outfall effectively dilutes the discharged effluent, thereby reducing the risk to biota and humans dependent upon the marine environment. In this study, we investigated the effluent transport from a marine outfall at different depths in Masan Bay. A particle-tracking model was used to predict the dispersion of effluent. The model results indicate that some particles released from a depth of 13 m move to the inner area of Masan Bay within 48 h. As the release depth increases after 48 h, the particles move further southward. This suggests that effluent from the outer area of Masan Bay can affect the inner area, and that this effect can be reduced by increasing the depth of effluent release.

Recovery of Golden yellow and Cibacron LSG dyes from aqueous solution by bulk liquid membrane technique

  • Muthuraman, G;Ali, P. Jahfar
    • Membrane and Water Treatment
    • /
    • v.3 no.4
    • /
    • pp.243-252
    • /
    • 2012
  • Tri-n-butyl phosphate (TBP) was used as carrier for the transport of Golden yellow and Cibacron LSG dyes through a hexane bulk liquid membrane. The transport efficiency of dyes by TBP was investigated under various experimental conditions such as pH of the feed phase (dyes solution), concentration of the receiving phase (NaOH solution), concentration of TBP in membrane, rate of stirring, effect of transport time, type of solvent, dye concentration in feed phase, effect of temperature.. The maximum transport dyes occurs at ratio of 1:1 TBP-hexane At pH 3.0 0.1 (feed phase) the transport dyes decreased. At high stirring speed (300 rpm) the dyes transport from the feed phase to the strip phase was completed within 60 minutes at $27^{\circ}C$. Under optimum conditions: Feed phase 100 mg/L dyes solution at pH 1.0 0.1, receiving phase 0.1 mol/L NaOH solution, membrane phase 1:1 TBP-hexane , Stirring speed 300 rpm and temperature $27^{\circ}C$, the proposed liquid membrane was applied to recover the textile effluent.