• Title/Summary/Keyword: liquid cooling

Search Result 899, Processing Time 0.025 seconds

Analysis of Eutectic Reaction as a Function of Cooling Rate in High Manganese Flake Graphite Cast Irons (고 망간 편상흑연주철에서 냉각속도별 공정반응 분석)

  • Lee, Sang-Hwan;Lee, Hyun-Woo;Lee, Sang-Mok
    • Journal of Korea Foundry Society
    • /
    • v.33 no.4
    • /
    • pp.162-170
    • /
    • 2013
  • The effects of Mn content and cooling rate on the eutectic reaction of flake graphite cast irons were studied by a combined analysis of macro/micro-structure and cooling curve data. The correlation between the eutectic reaction parameter and macro/microstructure was systematically investigated. Two sets of chemical compositions with different Mn contents were designed to cast. Three types of molds for cylindrical specimens with different diameters were prepared to analyze the cooling rate effect. The difference between undercooling temperature and cementite eutectic temperature (${\Delta}T_1=T_U-T_{E,C}$), which is decreased by increasing the Mn content or increasing the cooling rate, is considered to be a suitable eutectic reaction parameter for predicting graphite morphology. According to the criterion, A-type graphite is mainly suggested to form for ${\Delta}T_1$ over $20^{\circ}C$, and D-type graphite is mainly suggested to form for ${\Delta}T_1$ below $0^{\circ}C$. Eutectic reaction time (${\Delta}T$), which is increased by increasing the Mn content and decreased by increasing the cooling rate, is regarded as a suitable eutectic reaction parameter for predicting eutectic cell size. Eutectic cell size is found to decrease in proportion to the decrease of ${\Delta}T$.

Study on the Cooling Mechanism in a Cryogenic Cooling System (극저온 냉각 챔버 내 냉각 메커니즘 연구)

  • SEONGWOO LEE;YOUNGSANG NA;YOUNGKYUN KIM;SEUNGMIN JEON;JUNHO LEE;SUNGWOONG CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.2
    • /
    • pp.146-151
    • /
    • 2024
  • The demand for research on materials with excellent cryogenic strength and ductility has been increasing, particularly for applications such as liquid hydrogen (20 K) storage tanks. To effectively utilize liquid hydrogen, a system capable of maintaining and operating at 20 K is essential. Therefore, preliminary research and verification of the cooling system are crucial. In this study, a heat transfer analysis was conducted on a cooling system to meet the cryogenic environment requirements for cryogenic hydrogen chamber, which are conducted at liquid helium temperatures (4 K). The cooling mechanism in a helium cooling system was examined using numerical analysis. The numerical cooling trends were compared with experimentally obtained cooling results. The good agreement between numerical and experimental results suggests that the numerical approach developed in this study is applicable over a wide range of cryogenic systems.

An Experimental Study on Cooling Performance of Microchannel Waterblock for Electronic Devices Cooling (전자기기 냉각용 마이크로채널 워터블록의 냉각성능에 관한 실험적 연구)

  • Kwon, Oh-Kyung;Choi, Mi-Jin;Cha, Dong-An;Yun, Jae-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2432-2437
    • /
    • 2007
  • The demand of high speed and miniaturization of electronic devices results in increased power dissipation requirement for thermal management. In this work, the effects of microchannel width, height and liquid flowrate on the cooling performances of microchannel waterblock are investigated experimentally. The microchannel waterblock considered ranged in width from 0.5 to 0.9 mm, with the channel height being nominally 1.7 to 9 times the width in each case. The experiments were conducted using water, over a liquid flow rate ranging from 0.2 to 2.0 lpm. The base temperature, thermal resistance and pressure drop increase with increasing of liquid flow rate. The measured thermal resistances ranged from 0.10 to 0.23 $^{\circ}C$/W for the channel 5.

  • PDF

Evaluation on the Characteristics of Liquefied Natural Gas as a Fuel of Liquid Rocket Engine

  • Namkoung, Hyuck-joon;Han, Poong-Gyoo;Kim, Kyoung-Ho
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.148-154
    • /
    • 2004
  • As a rocket propellent of hydrocarbon fuels, the characteristics of liquefied natural gas was evaluated with the viewpoint of the constituents and content, the cooling performance as a coolant, and characteristic velocity and specific impulse as parameters of the engine performance. Content of methane was a principal factor to determine the characteristics as a rocket propellant and more than 90 % of it was needed as a fuel and coolant in the regenerative cooled liquid rocket engine. Some constituents of the liquefied natural gas can be frozen by the pre-cooling of the pipe lines, therefore they can be a factor disturbing the normal working of engine. In case the content of methane is around 90% in the liquefied natural gas, a normalized stoichiometric O/F mixture ratio of 0.75 is suggested for a nominal operation condition to get the maximum specific impulse and characteristic velocity.

  • PDF

A Case Study on the Design of Kerosene-LOx Liquid-Propellant Rocket Engines for Performance Enhancement (케로신-액체산소 액체로켓엔진의 성능향상 설계안 사례 조사)

  • Lee, Seon-Mi;Moon, In-Sang;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.12-15
    • /
    • 2011
  • The most widely used kerosene-LOx liquid-propellant rocket engines in these days have a similar engine schematic to those of the past because of the development cost and the reliability. The efficiency of engines could be increased by the factors such as a cooling method, engine cycles, shape of cooling channels, additional coolant and so on. In this article, it is described that some design ideas for performance enhancement by exchange kerosene with LOx of a coolant.

  • PDF

A Numerical Study on the Cooling Characteristics of Seeker Windows for Selecting Efficient Cooling Method (효율적인 냉각 방식 선정을 위한 탐색창 냉각 특성 해석 연구)

  • Kim, Manshik;Lee, Dong Min
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.246-254
    • /
    • 2017
  • In this paper, cooling characteristics of seeker windows were examined using the Sinda-Fluint software. Various cooling methods were considered to satisfy the limit temperature of the cooled seeker window which would be exposed to excessive aerodynamic heating conditions by varying coolant type and mass flow rate of coolant. Due to the enhanced heat transfer between the coolant and the seeker window, internally cooled seeker window which uses liquid coolant showed lowered temperature distribution in the window compared to internally cooled seeker window which uses gas coolant. External film cooled seeker window also showed good cooling characteristics because it reduces the convective heat flux to the seeker window fundamentally. It was also confirmed that the temperature and the temperature gradient of seeker windows were significantly reduced for the cases which use external film cooling additionally to the gas and liquid cooled seeker window.

A Study on Cooling Characteristics of Combustion Gas by Liquid Nitrogen in a Liquid Rocket Engine (액체질소를 이용한 액체 로켓 엔진 연소 가스 냉각 특성 연구)

  • Jeon, Jun-Su;Lee, Yang-Suk;Song, Jae-Kang;Kim, Yoo;Ko, Young-Sung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.147-150
    • /
    • 2007
  • In this study, cooling characteristics of combustion gas were investigated by injecting liquid nitrogen into liquid rocket combustion chamber. A injection ring of liquid nitrogen was installed between a combustion chamber and a mixing chamber which was designed for mixing of combustion gas and nitrogen. At first, a ignition test of liquid rocket engine was conducted to verify a stable combustion process and 10 second combustion tests were successfully conducted. The results showed that combustion gas of LRE could be cooled by using liquid nitrogen.

  • PDF

Design Considerations on the Standby Cooling System for the integrity of the CNS-IPA

  • Choi, Jungwoon;Kim, Young-ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.104-104
    • /
    • 2015
  • Due to the demand of the cold neutron flux in the neutron science and beam utilization technology, the cold neutron source (CNS) has been constructed and operating in the nuclear research reactor all over the world. The majority of the heat load removal scheme in the CNS is two-phase thermosiphon using the liquid hydrogen as a moderator. The CNS moderates thermal neutrons through a cryogenic moderator, liquid hydrogen, into cold neutrons with the generation of the nuclear heat load. The liquid hydrogen in a moderator cell is evaporated for the removal of the generated heat load from the neutron moderation and flows upward into a heat exchanger, where the hydrogen gas is liquefied by the cryogenic helium gas supplied from a helium refrigeration system. The liquefied hydrogen flows down to the moderator cell. To keep the required liquid hydrogen stable in the moderator cell, the CNS consists of an in-pool assembly (IPA) connected with the hydrogen system to handle the required hydrogen gas, the vacuum system to create the thermal insulation, and the helium refrigeration system to provide the cooling capacity. If one of systems is running out of order, the operating research reactor shall be tripped because the integrity of the CNS-IPA is not secured under the full power operation of the reactor. To prevent unscheduled reactor shutdown during a long time because the research reactor has been operating with the multi-purposes, the introduction of the standby cooling system (STS) can be a solution. In this presentation, the design considerations are considered how to design the STS satisfied with the following objectives: (a) to keep the moderator cell less than 350 K during the full power operation of the reactor under loss of the vacuum, loss of the cooling power, loss of common electrical power, or loss of instrument air cases; (b) to circulate smoothly helium gas in the STS circulation loop; (c) to re-start-up the reactor within 1 hour after its trip to avoid the Xenon build-up because more than certain concentration of Xenon makes that the reactor cannot start-up again; (d) to minimize the possibility of the hydrogen-oxygen reaction in the hydrogen boundary.

  • PDF

Research Activities of Transpiration Cooling for Liquid Rocket and Air-breathing Propulsions (액체로켓과 공기흡입식 추진기관을 위한 분출냉각의 연구동향)

  • Hwang, Ki-Young;Kim, You-Il;Song, In-Hyuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.235-240
    • /
    • 2010
  • Transpiration cooling is the most effective cooling technique for liquid rocket and air-breathing engines operating in aggressive environments with higher pressures and temperatures. Combustor liners and turbine vanes are cooled by the coolant(air or fuel) passing through their porous walls and also the exit coolant acting as an insulating film. However, its practical implementation has been hampered by the limitations of available porous materials. The search for more practical methods of increasing the internal heat transfer within the walls has led to the development of multi-laminate porous structures, such as Lamilloy$^{(R)}$ and Transply$^{(R)}$. This paper reviews recent research activities of transpiration cooling for the propulsions of liquid rocket, gas turbine, and scramjet.

  • PDF

Specific Impulse Variation of a Liquid Rocket Engine by Film Cooling (막냉각에 의한 액체로켓엔진의 비추력 변화)

  • Cho, Won-Kook;Park, Soon-Young;Seol, Woo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.133-139
    • /
    • 2009
  • An analysis has been performed on the specific impulse for a liquid rocket engine of gas generator cycle. The present analysis method has been validated through the comparison of the optimal specific impulse for the 300t thrust conceptual engine against the published data. The engine specific impulse can be increased by applying film coolant decreasing the fuel pump head for regenerative cooling despite the decrease of specific impulse of the combustion chamber when the film coolant participates combustion more than the critical amount. The improved condition shows that higher combustion chamber pressure is achieved with less fuel pump head rise by additional film cooling.

  • PDF