• 제목/요약/키워드: linearity test

검색결과 404건 처리시간 0.028초

속중성자 탐지용 반도체 소자 개발 (Development of a Fast Neutron Detector)

  • 이남호;김승호;김양모
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.545-552
    • /
    • 2003
  • When a Si PIN diode is exposed to fast neutrons, it results in displacement damage to the Si lattice structure of the diode. Defects induced from structural dislocation become effective recombination centers for carriers which pass through the base of a PIN diode. Hence, increasing the resistivity of the diode decreases the current for the applied forward voltage. This paper involves the development of a neutron sensor based on the phenomena of the displacement effect damaged by neutron exposure. The neutron effect on the semiconductor was analyzed. Several PIN diode arrays with various thickness and cross-section area of the intrinsic layer(I layer) were fabricated. Under irradiation tests with a neutron beam, the manufactured diodes have a good linearity to neutron dose and show that the increase of thickness of I layer and the decrease of cross-section of PIN diodes improve the sensitivity. Newly developed PIN diodes with thicker I layer and various cross section, were retested and then showed the best neutron sensitivity at the condition that the I layer thickness was similar to a side length. On the basis of two test results, final discrete PIN diodes with a rectangular shape were manufactured and the characteristics as neutron detectors were analyzed through the neutron beam test using on-line electronic dosimetry system. Developed PIN diode shows a good linearity as dosimetry in the range of 0 to 1,000cGy(Tissue) and its neutron sensitivity is 13mV/cGy at constant current of 5mA, that is three times higher than that of commercially available neutron detectors. And the device shows little dependency on the orientation of the neutron beam and a considerable stability in annealing test for a long period.

Alpha feto protein(AFP)검사 키트의 유효성 평가실험 (Evaluation of the Kit's Efficiency of Alpha Fetoprotein (AFP) Test)

  • 조현수;노경운;유태민
    • 핵의학기술
    • /
    • 제22권2호
    • /
    • pp.101-104
    • /
    • 2018
  • Purpose Alpha fetoprotein(AFP) is a fetal serum protein that increases in germ cell tumors derived from liver cancer or egg yolk. AFP test has been used for screening of liver cancer, determination of tumor stage, determination of therapeutic effect, and fetal congenital malformations. The purpose of this study was to compare the results of the four kits, identify the advantages and disadvantages of each kit, and select the appropriate kits for our laboratory. Materials and Methods Blood samples were obtained from 89 patients attending the Seoul national university hospital. Experiments were carried out in accordance with manufacturer's instructions of four companies(A, B, C, D). The precision, recovery, linearity, and sensitivity test were performed for each kit. Results In case of the precision within the measurement, the CV value of the C kit was less than 5% at the low, middle, and high concentrations. The A, B and D kit's the CV value was less than 5% at the concentrations except the low concentration. The recovery rates of the A, B, C, and D kits were $100{\pm}15%$, $100{\pm}30%$, $100{\pm}16%$ and $100{\pm}14%$, respectively. All kits showed good linearity. Sensitivity was measured as 0.5 IU/mL for A, 0.4 IU/mL for B, 0.98 IU/mL for C, and 0.3 IU/mL for D. Conclusion The CV values of the four kits were within 10%, and the correlation coefficients were close to 1 for $R^2=0.978$, $R^2=0.992$ and $R^2=0.8957$. As a result, they are clinically available. Therefore, each laboratory should select the appropriate kit for their experiment's environment.

분석측정범위의 실증적 평가 (An Empirical Study of the Analytical Measurement Range in Clinical Chemistry)

  • 장상우;이상곤;김영환;송은영;박용원;박병옥;류재기
    • 대한임상검사과학회지
    • /
    • 제38권2호
    • /
    • pp.117-124
    • /
    • 2006
  • The analytical measurement range (AMR) is the range of analyte values that a method can directly measure on a specimen without any dilution, concentration, or other pretreatment not part of the usual assay process. The linearity of the AMR is its ability to obtain test results which are directly proportional to the concentration of analyte in the sample from the upper and lower limit of the AMR. The AMR validation is the process of confirming that the assay system will correctly recover the concentration or activity of the analyte over the AMR. The test specimen must have analyte values which, at a minimum, are near the low, midpoint, and high values of the AMR. The AMR must be revalidated at least every six months, at changes in major system components, and when a complete change in reagents for a procesure is introduced; unless the laboratory can demonstrate that changing the reagent lot number does not affect the range used to report patient test results. The AMR linearity was total protein (0-16.6), albumin (0-8.1), total bilirubin (0-18.1), alkaline phosphatase (0-1244.3), aspartate aminotransferase (0-1527.9), alanine aminotransferase (0-1107.9), gamma glutamyl transpeptidase (0-1527.7), creatine kinase (0-1666.6), lactate dehydrogenase (0-1342), high density lipoprotein cholesterol (0.3-154.3), sodium (35.4-309), creatinine (0-19.2), blood urea nitrogen (0.5-206.2), uric acid (0-23.9), total cholesterol (-0.3-510), triglycerides (0.7-539.6), glucose (0-672.7), amylase (0-1595.3), calcium (0-23.9), inorganic phosphorus (0.03-17.0), potassium (0.1-116.5), chloride (3.3-278.7). We are sure that materials for the AMR affect the evaluation of the upper limit of the AMR in the process system.

  • PDF

진단용 엑스선 장치의 안전관리 검사에 관한 연구 (A Study on Safety Management Inspection of Diagnostic X-ray System)

  • 이후민;김현주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.887-893
    • /
    • 2018
  • 본 연구는 병원 및 대학교 등에 설치된 X선 발생장치를 대상으로 진단용 방사선 발생장치의 품질관리 항목을 적용하여 성능 비교를 하여 주기적인 성능관리의 중요성을 인식시켜 성능유지 및 관리에 도움을 주고자 한다. 우선 재현성 및 직선성 실험결과 모든 실험조건에서 합격기준에 부합되었으며 주기적인 정도관리가 부족한 GX-650장치의 경우 재현성 평가의 백분율 오차가 높았으며 직선성 평가에서는 관전압을 100 kVp로 설정 시 0.105로 백분율 오차에서 벗어나게 측정되었다. 또한 관전압 및 관전류의 정확도 평가결과 상대적으로 X선 발생횟수가 낮은 장치에서 백분율 오차가 낮은 것을 알 수 있었다. 반가층 실험은 모든 장치에서 관전압 별 반가층 기준에 모두 포함되었다. 따라서 병원용, 실습용 구분보다는 모든 장치의 정도관리의 중요성을 인식하고 적극적으로 장치의 성능관리를 시행하여 장치를 유지 관리해야 할 것이며 특수의료장비처럼 짧은 주기의 정도관리 제도를 마련해야 할 것으로 사료된다.

다회선 초음파 유량계를 이용한 거래용 오일유량 측정 (Custody Transfer Hydrocarbon Flow Measurement with Multi-path Ultrasonic Flow Measurement)

  • 황상윤;이호준;박기환
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.149-153
    • /
    • 2003
  • As the fastest growing flowmeter technology, multi-path ultrasonic flow-meters are gaining wider range in petroleum industry for liquid hydrocarbon custody transfer measurement. This paper describes the mult-path ultrasonic flowmeter, URO-Ex1000 the requirements necessary to prove and test in Korea & China. URO-Ex1000 haver a good results with accuracy range, but a little exceed with repeatability.

  • PDF

A study on the analysis of artificial sweeteners in processed foods including emulsified foods by HPLC-DAD

  • Kim, Min-Hee;Lee, Do-Yeon;Ahn, Jang-Hyuk
    • 분석과학
    • /
    • 제33권5호
    • /
    • pp.209-214
    • /
    • 2020
  • This study has been carried out to develop a standard method for quantifying of 3 permitted artificial sweeteners (including sodium saccharine, aspartame, acesulfame potassium) contained in foods by HPLC-DAD. A simple and rapid sample pretreatment method was used to remove fat and protein from the test solution with Carrez clearing regent precipitant know to be effective for protein and fat removal. The artificial sweeteners in the test solution purified through sample pretreatment were detected by high performance liquid chromatograph using a Reverse phase C18 column (5 ㎛, 4.6 × 250 mm). The simultaneous quantitative test of 3 kinds of artificial sweeteners can be effectively performed on the high fat emulsified foods containing a large amount of fat. Using the established simultaneous quantitative test method, artificial sweeteners were tested in foods such as dairy products, snacks and chocolate. The results calibration curve showed good linearity with high regression coefficients and the result of recovery test showed satisfactory recoveries within 80~110 %.

A Study on the Limits of the Comparative School Record Using the Individual Scholastic Evaluation

  • Chung, Yeon-Soo
    • Communications for Statistical Applications and Methods
    • /
    • 제7권2호
    • /
    • pp.465-473
    • /
    • 2000
  • There is no progress in interpreting the correlation between the high school record and the scholastic aptitude test. This study gives the degree of the linearity between the high school record and the scholastic aptitude test by using the method of the individual scholastic evaluation which was proposed by Chung(1999). The limits of the individual scholastic evaluation are pointed out additionally in inferring the promising individuals having the high scores in the scholastic aptitude test so that the individual scholastic evaluation be used as reference materials when the colleges applying the comparative school record in the entrance exams.

  • PDF

Spray type과 Soot type 입자발생기별 나노입자 개수농도분포 측정특성 비교 (Comparison on Nano-particle Number Measurement Characteristics for Different Particle Generators between Spray type and Soot Type)

  • 김민식;권지원;정명철;이진욱
    • 한국분무공학회지
    • /
    • 제17권4호
    • /
    • pp.185-191
    • /
    • 2012
  • Particulate matters (PM) that is generated by most diesel engine is regulated by the mass concentration measured by the conventional method it had been. Recently, Europe PMP (Particle Measurement Program) decided to start the regulation of vehicle's nano-sized particle number (PN) from the year of 2011 because of nano-particle's higher degree of harm to the human body. So firstly, the standard level of PN emission is introduced in the Euro 5/6 emissions regulation with a limit of $6{\times}10^{11}$ per km for light duty vehicle. Also KPMP(Korea Particle Measurement Program) was organized to copy quickly international technical trend. In this paper, it was investigated the nano-sized PN measurement characteristics for different particle generators between spray type and soot type. And the difference ratio between particle generators, the characteristic of PN concentration, counting efficiency and linearity was analyzed. Then, we make conclusions as followed. When particle diameter is increased, counting efficiency of two generators is decreased. Also Secondary calibration method is more higher 3% than Primary calibration method. Finally, SOF which is included in soot particles is not totally removed so it have great influence on test result of counting efficiency and linearity.

다리 환자를 위한 보행보조로봇의 종아리 링크 3축 힘센서 개발 (Development of Calf Link Force Sensors of Walking Assist Robot for Leg Patients)

  • 김한솔;김갑순
    • 센서학회지
    • /
    • 제26권2호
    • /
    • pp.114-121
    • /
    • 2017
  • This paper describes the design and fabrication of a three-axis force sensor with parallel plate beams (PPSs) for measuring the calf force while a patient with a walking assist robot is walking. Current walking assist robots can't measure the weight of the patient's leg and the robot's leg which required for robot control. So, the three-axis force sensor in the calf link is designed and manufactured, it is composed of a Fx force sensor, a Fy force sensor and a Fz force sensor. The three-axis force sensor was designed using by FEM(Finite Element Method), and fabricated using strain-gages. The characteristics experiment of the three-axis force sensor was carried out respectively. The test results indicated that the repeatability error and the non-linearity error of three-axis force sensor was less than 0.04% respectively. Therefore, the fabricated three-axis force sensor in the calf link can be used to measure the patient's calf force in the walking assist robot.

사진 계측에 의한 아동의 동체 형상 분석(I) (An Analysis of Children's Torso Using Photographic Anthropometry)

  • 전은경
    • 한국생활과학회지
    • /
    • 제6권2호
    • /
    • pp.145-155
    • /
    • 1997
  • The purpose of this study is to analyze the body type of children's, especially torso, and to provide the fundamental data for children's clothing construction which can reflect the characteristics of their bodies. The subjects for photographic measurements are 308 elementary school children aged from 6 to 8 living in Seoul and urban area. Anthropometric measurements were performed indirectly from the pictures of subjects. The data were analyzed statistically using SPSSWIN. The results obtained from this study are as follows: 1. Through one-way ANOVA, items for heights, breaths, weight reveals the significant differences according to ages and genders. 2. Through Pearson correlation, it turns out that there are high correlation between any items of heights, but there is no correlation for item of shoulder inclination with any other items. 3. Through factor analysis of principal component model, six factors were extracted which covers 83.6% of the whole information. The first factor represents the items of heights which relates with linearity. The second factor describes the items of breaths, depths, and weight in relation with laterality. The third factor were gathered with depths of front and back in relation with posture of side, which proves as important one to characterize the children's torso. The other factors represents the items of posture of neck, depths in neck, shoulder inclination, respectively. 4. Through one-way ANOVA in factor by group, and Scheffe multi comparison test for each group, the factor 1 that is related with linearity reveals the significant differences according to ages and genders.

  • PDF