• Title/Summary/Keyword: linear stability

Search Result 2,081, Processing Time 0.037 seconds

A New Small Size Digital Optical Ozone Monitor Using CCD Array as a UV Detector (UV 감지기로서 CCD어레이를 사용한 소형 디지털 광 오존모니터)

  • Chung, Wan-Young;Lee, Seung-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.1
    • /
    • pp.158-163
    • /
    • 2008
  • Ozone monitor based on UV techniques has been widely used due to their signal stability. The high concentration ozone monitor for real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source and a photo multiplier tube as UV detector. The structure could be very useful for low price high concentration ozone monitor and showed good linearity to ozone in the concentration range between 0.05 and 2wt%. For accurate ambient ozone monitoring, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector. The optical signal form the CCD array was converted to digital signal, and the digital signal was displayed on screen using PC interface. The developed system showed good linearity and sensitivity in relatively low measuring range between 10ppm and 10,000ppm, and showed some feasibility of hish resolution ozone monitor using CCD array as a photodetecor.

An Output Feedback Predictive Control for Stabilizing a System With Multiple Delayed Inputs (지연된 다중 입력을 갖는 시스템을 안정화하는 출력 궤환 예측 제어)

  • Yang, Janghoon
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.424-429
    • /
    • 2019
  • The evolution of networking technology such as commercialization of 5G systems provides foundation for information exchange and control of systems over the network. In addition, importance of controlling a system with delay is increasing significantly, since various phenomena in the network are associated with delay. In this paper, with a predictive control which has been studied for designing a controller with low complexity, we propose a novel predictive control for a system with multi-inputs such that it can keeps the complexity almost the same regardless of the number of inputs and degree of delay. The asymptotic stability of the proposed control with a static output feedback is also proved. The numerical simulation shows that the proposed method is superior in complexity and the performance of finding feasible controllers to the existing predictive control and a conventional method based on augmented states.

Thermal buckling analysis of FG plates resting on elastic foundation based on an efficient and simple trigonometric shear deformation theory

  • Tebboune, Wafa;Benrahou, Kouider Halim;Houari, Mohammed Sid Ahmed;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • v.18 no.2
    • /
    • pp.443-465
    • /
    • 2015
  • In this paper, an efficient and simple trigonometric shear deformation theory is presented for thermal buckling analysis of functionally graded plates. It is assumed that the plate is in contact with elastic foundation during deformation. The theory accounts for sinusoidal distribution of transverse shear stress, and satisfies the free transverse shear stress conditions on the top and bottom surfaces of the plate without using shear correction factor. Unlike the conventional trigonometric shear deformation theory, the proposed sinusoidal shear deformation theory contains only four unknowns. It is assumed that the mechanical and thermal non-homogeneous properties of functionally graded plate vary smoothly by distribution of power law across the plate thickness. Using the non-linear strain-displacement relations, the equilibrium and stability equations of plates made of functionally graded materials are derived. The boundary conditions for the plate are assumed to be simply supported on all edges. The elastic foundation is modelled by two-parameters Pasternak model, which is obtained by adding a shear layer to the Winkler model. The effects of thermal loading types and variations of power of functionally graded material, aspect ratio, and thickness ratio on the critical buckling temperature of functionally graded plates are investigated and discussed.

Electrochemical Properties of Biosensor with Butyl Rubber Binder (부틸고무를 결합재로 사용한 바이오센서의 전기화학적 성질)

  • Choi, Sei-Young;Yoon, Kil-Joong
    • Elastomers and Composites
    • /
    • v.41 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • An enzyme electrode bound by butyl rubber was newly constructed for the determination of hydrogen peroxide and for the practical application as a biosensor. Then its electrochemical properties were investigated. It produced a hundreds-fold increased signal compared to the plant or animal tissue based biosensor studied previously and could be run at between $0.0{\sim}-1.00\;V$(vs. Ag/AgCl). The relationship between signal and electrode potential was linear in the experimental range of potential. It showed a detection limit of $3.0{\times}10^{-4}\;M$ and a very good linearity of Lineweaver-Burk plot giving the proof of a good enzyme immobilization. Especially, both the reproducibility of signal current due to its high sensitivity and mechanical stability presented a new possibility for the practical use of biosensor bound with butyl rubber.

Development of a Sensitive Analytical Method of Polynemoraline C Using LC-MS/MS and Its Application to a Pharmacokinetic Study in Mice

  • Pang, Minyeong;Lee, Jaehyeok;Jeon, Ji-Hyeon;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.12 no.4
    • /
    • pp.200-205
    • /
    • 2021
  • Polynemoraline C, a pyridocoumarin alkaloid, exhibits anticholinergic, anti-inflammatory, antitumor, and antimicrobial activities. A sensitive analytical method of polynemoraline C in mouse plasma was developed and validated using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Polynemoraline C and 13C-caffeine (internal standard) in mouse plasma were extracted using a liquid-liquid extraction method coupled with ethyl acetate. This extraction method resulted in high and reproducible extraction recovery in the range of 73.49%-77.31% with no interfering peaks around the peak retention time of polynemoraline C and 13C-caffeine. The standard calibration curves for polynemoraline C were linear over the range of 0.5-200 ng/mL with r2 > 0.985. The accuracy, precision, and the stability of the data were within acceptable limits on the FDA guideline. After intravenous and oral administration of polynemoraline C at doses of 5 and 30 mg/kg, respectively, the present method was successfully applied to the pharmacokinetic study of polynemoraline C. Polynemoraline C in mouse plasma showed a multi-exponential elimination pattern with a high volume of distribution values. This compound's absolute oral bioavailability was found to be 17.0%. Polynemoraline C's newly developed LC-MS/MS method can be used for further studies on the efficacy, toxicity, and biopharmaceutics of polynemoraline C, as well as its pharmacokinetic studies.

Development of Unmanned Remote Radiation Detection Module (무인 원격 방사선 검출 모듈 개발)

  • Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.795-801
    • /
    • 2021
  • The designed drone-based unmanned remote radiation detection module was developed according to the needs of the nuclear power plant decommissioning workshop. Using the Geiger-Mueller tube sensitive to low-level radiation measurement, It was manufactured to measure the amount of radiation leaking into and out of the containment vessel. The drone-based radiation detection module weighs less than 200g, It can be operated inside and outside the containment vessel of a nuclear power plant. To check the performance of the designed equipment, a performance evaluation test was conducted with reference to the international standard (IEC-60864). The stability of the radiation detection module designed to meet the needs of the field the statistical rate of change by repeated measurements in the rate of change experiment to evaluate the measurement accuracy was ±4.6%. The accuracy ±7.3% in the linearity experiment to evaluate the dose rate dependence, the linear The figure satisfies the international performance evaluation standard of ±3.5%. The radiation detection module developed in this study is a customized equipment for a nuclear power plant dismantling workshop. It will be helpful for accurate measurement of space dose rate and safety management of radiation worksites in sites with a lot of radiation dust.

Mid-Term Performance of Clinical LINAC in Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.43-52
    • /
    • 2019
  • Background: The mid-term performance of clinical linear accelerator (LINAC) during volumetric modulated arc therapy (VMAT) treatment period is not performed in clinical practice and usually replaced with one-time plan quality assurance (QA). In this research we aim to monitor daily reproducibility of VMAT delivery from tracking individual leaf movement error and dosimetric error to evaluate the mid-term quality of the machine used. Materials and Methods: First, multileaf collimator (MLC) information was imported into MATLAB program to determine which of the MLC leaves in the leaf bank had the maximum RMS position error (maxRMS). We estimated where the maximum positional errors (maxPE) of the chosen leaf occur along its path length and tracked its daily variations over the entire treatment period. Secondly, picture information of dosimetric error from portal dosimetry was imported into MATLAB where representative high gamma index region (HGR) was determined as HGR with length of > 1 cm and their centers were daily tracked. Results and Discussion: The maxPEs in the brain and tongue cases were distributed broader than in other cases, but all data were found located within ${\pm}0.5mm$. From first day to last day all of five cases show the similar visual pattern of HGRs and Centers of the longest HGRs remained within ${\pm}1mm$ of that in first day. These findings prove excellent mid-term performance of the LINAC used in VMAT treatments over a full course of treatment. Conclusion: Tracking the daily location changes of leaf movement and dosimetric error can be a good indicator of predicting the daily quality like stability and reproducibility of beam delivering in VMAT treatment.

A Study on the Structural System and Implementation of Cantilever Actuator System (외팔보 엑츄에이터 시스템 구조 및 구현에 관한 연구)

  • Yoon, Keun-Young;Baek, Soo-Whang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.4
    • /
    • pp.651-656
    • /
    • 2019
  • This paper is a study on the structure system and implementation of cantilever actuator for decontamination. There are many kinds of exterior materials that attach to the exterior walls of a building. Glass, in particular, can be contaminated in a short period of time due to external exposure. The pollutants like this damage the appearance of a building. It can also cause health problems for users, and dust attached to solar panels creates problems that greatly reduce the power generation of solar panels. In order to remove such contaminants, professional workers usually remove contaminants attached to the outer walls. However, even with stability, accidents are often caused by a number of unexpected variables that occur in the field. Thus, to overcome these shortcomings, the cantilever actuator structure system was proposed. The system was designed through research. Then, we made a cantilever actuator and checked its operability. Finally, the effectiveness of the cantilever actuator was reviewed.

A Comparative Study on the Behavior of High-rise Buildings by 2D and 3D Dynamic Analysis with Considering the Ground (초고층 건물의 지반을 고려한 2D 및 3D 동적해석에 의한 거동 비교 연구)

  • You, Kwangho;Baek, Yong;Kim, Seungjin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.10
    • /
    • pp.5-14
    • /
    • 2019
  • Recently, earthquakes have occurred in our country and seismic stability of high-rise buildings in large cities is being a growing interest and thus the related studies have been increased. Also the grounds are considered indirectly in most of seismic designs and analyses and seismic researches based on 3D dynamic analysis are insufficient. In this study, therefore, 2D and 3D dynamic analyses were performed based on the SSI complete model including grounds and the behavior was compared and analyzed. For dynamic modeling, linear time history analyses were performed by using MIDAS GTS NX. For this purpose, a high-rise building was assumed to be constructed on top of the bedrock and surrounded by a surface layer. A sensitivity analysis was performed with the selected parameters. The dynamic behavior was compared and analyzed in terms of horizontal displacements, drift ratios, bending stresses, and weak parts. In most cases, 2D dynamic behavior was calculated to be larger than 3D's and thus it shows more conservative results with increasing number and size of weak parts.

Development and Validation of an LC-MS/MS Method for Determination of Damaurone D in Rat Plasma and its Application to Pharmacokinetic Study in Rats

  • Lee, Wonpyo;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Mass Spectrometry Letters
    • /
    • v.10 no.1
    • /
    • pp.38-42
    • /
    • 2019
  • Damaurone D belongs to the genus Rosa and is a traditional medicinal product used for the treatment of depression, inflammation, and infectious diseases. The purpose of this study was to develop a simple liquid chromatography-tandem mass spectrometry method for the detection of damaurone D in rat plasma and to demonstrate its application in pharmacokinetic studies. Damaurone D and berberine (internal standard) were extracted with acetonitrile using a protein precipitation method. Mass transition was monitored in multiple reaction monitoring mode at m/z $323.2{\rightarrow}267.0$ for damaurone D and m/z $336.1{\rightarrow}320.0$ for berberine in positive ion mode. Analytical validation was conducted by evaluating the specificity, linearity, accuracy, precision, matrix effect, extraction recovery, and stability. The calibration curves were linear over 2-1000 ng/mL. The intra- and inter-day precision and accuracy of quality control samples were 4.79-13.33% and 86.23-102.75%, respectively. The matrix effect and extraction recovery were 96.11-98.47% and 96.11-102.25%, respectively. In the pharmacokinetic study after intravenous administration of damaurone D at a dose of 3 mg/kg in rats, the area under the curve and clearance of damaurone D in rat plasma were $16750.26{\pm}2676.10min{\cdot}ng/mL$ and $182.44{\pm}31.36mL/min/kg$, respectively.