• Title/Summary/Keyword: linear resolution

Search Result 748, Processing Time 0.028 seconds

Analysis of Heat and Vibration of Super-Precision Linear Motors (초정밀 선형 모터의 열$\cdot$진동 분석)

  • Lee Woo Young;Rim Kyung Hwa;Seol Jin Soo;Kim Hyun Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.1 s.10
    • /
    • pp.1-8
    • /
    • 2005
  • Linear motor can be directly applied to the system needed linear motions without rotary motions. To control high-speed and high-resolution, the development of the linear motors is recently required in the high-integrated and speed process industry This paper presents thermal and vibration analyses as well as measurement standards of the newly developed linear motors through analyzing the thermal behaviors and vibration characteristics of the advanced products. The thermal measurements are conducted for comparing the developed linear motor with the advanced linear motor and the Finite Volume Method(FVM) is used to identify the measurement results. And then the vibration measurement are carried out in the developed and advanced linear motors with respect to the speed. To identify the measurement results, the Finite Element Method is utilized in the developed and advanced linear motors, respectively. The FVM, FEM, and experiments make it possible to understand these characteristics. The improvement is suggested through their results conducted experiment and analyses.

  • PDF

Determination of Epipolar Geometry for High Resolution Satellite Images

  • Noh Myoung-Jong;Cho Woosug
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.652-655
    • /
    • 2004
  • The geometry of satellite image captured by linear pushbroom scanner is different from that of frame camera image. Since the exterior orientation parameters for satellite image will vary scan line by scan line, the epipolar geometry of satellite image differs from that of frame camera image. As we know, 2D affine orientation for the epipolar image of linear pushbroom scanners system are well-established by using the collinearity equation (Testsu Ono, 1999). Also, another epipolar geometry of linear pushbroom scanner system is recently established by Habib(2002). He reported that the epipolar geometry of linear push broom satellite image is realized by parallel projection based on 2D affine models. Here, in this paper, we compared the Ono's method with Habib's method. In addition, we proposed a method that generates epipolar resampled images. For the experiment, IKONOS stereo images were used in generating epipolar images.

  • PDF

Study on Self-moving Cell Linear Motor Using Piezo-stack actuators (적층 압전 작동기를 이용한 Self-moving Cell 선형모터 연구)

  • 이진호;김재환;최관영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.371-375
    • /
    • 2001
  • The concept of a new linear motor that uses piezo-stack actuator is demonstrated. The working principle is far different from the conventional inchworm motor. This motor is based on the self-moving cell concept. The linear motor has three cells and each cell is constructed with one piezo-stack actuator and a shell structure. A cell train is constructed by connecting these cells and the cell train is fitted into a guide way with a proper interference. The cell train moves along the guide way, by activating each cell in succession. The moving motion of the motor is tested. Since this linear motor uses piezo-stack actuator with unified clamping cell, it can produce fast speed, high resolution and large push force.

  • PDF

Characteristic Test of High Force Linear Motor Feed Unit for High Speed Machine Tool (고속가공기용 고추력 리니어모터 이송계의 특성 평가)

  • 송창규;황주호;박천홍;이후상;정재한
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.977-981
    • /
    • 2000
  • Direct drive linear motors have large potential for use as high speed machine tool feed units since they can increase machining rates and improve servo accuracy by eliminating gear related machining problems. So, in this paper, characteristic of 2-axis linear motor feed unit are studied and control gain are adjusted considering positioning, velocity, acceleration and static stiffness. We confirm linear motor feed unit are affected value of control gain sensitively, because drive directly. From the experiment, this feed unit has l${\mu}{\textrm}{m}$ micro step resolution, 5.7${\mu}{\textrm}{m}$ positioning accuracy and under 60${\mu}{\textrm}{m}$ circularity.

  • PDF

Usefulness analysis of radial non-cartesian trajectory in the high-resolution MRA (고해상도 MRA 시 방사형 비직각좌표계 k-space 주사방식의 유용성 분석)

  • Lee, Ho-Beom;Choi, Kwan-Woo;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6284-6289
    • /
    • 2013
  • With the application of k-space trajectory in a different manner and analyzing the influence of noise and its direction, this study was conducted to obtain high-quality images with minimal influence of noise during an MRI examination for cerebrovascular disease, which has a low signal for imaging. To evaluate influence of the noise of different k-space trajectories, a linear Cartesian coordination trajectory and non-Cartesian coordination trajectory were applied to 38 people who had received a high-resolution MRI examination for the early detection of cerebrovascular disease. As a result, the non-Cartesian coordination trajectory showed a 43.32% lower signal of lumens in the internal carotid artery than a linear Cartesian coordination trajectory, and the noise level was also 50.19% lower in a non-Cartesian coordination trajectory. This result shows that noise occurs less in a non-Cartesian coordination trajectory than a linear Cartesian coordination trajectory, and a non-Cartesian coordination trajectory is more effective in low-signal and low-resolution MRI examination. Therefore, when performing high-resolution MRI examination with a low-signal cerebrovascular system, the use of non-Cartesian coordination k-space trajectory will minimize the influence of noise and provide good images.

Impact of Trend Estimates on Predictive Performance in Model Evaluation for Spatial Downscaling of Satellite-based Precipitation Data

  • Kim, Yeseul;Park, No-Wook
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.1
    • /
    • pp.25-35
    • /
    • 2017
  • Spatial downscaling with fine resolution auxiliary variables has been widely applied to predict precipitation at fine resolution from coarse resolution satellite-based precipitation products. The spatial downscaling framework is usually based on the decomposition of precipitation values into trend and residual components. The fine resolution auxiliary variables contribute to the estimation of the trend components. The main focus of this study is on quantitative analysis of impacts of trend component estimates on predictive performance in spatial downscaling. Two regression models were considered to estimate the trend components: multiple linear regression (MLR) and geographically weighted regression (GWR). After estimating the trend components using the two models,residual components were predicted at fine resolution grids using area-to-point kriging. Finally, the sum of the trend and residual components were considered as downscaling results. From the downscaling experiments with time-series Tropical Rainfall Measuring Mission (TRMM) 3B43 precipitation data, MLR-based downscaling showed the similar or even better predictive performance, compared with GWR-based downscaling with very high explanatory power. Despite very high explanatory power of GWR, the relationships quantified from TRMM precipitation data with errors and the auxiliary variables at coarse resolution may exaggerate the errors in the trend components at fine resolution. As a result, the errors attached to the trend estimates greatly affected the predictive performance. These results indicate that any regression model with high explanatory power does not always improve predictive performance due to intrinsic errors of the input coarse resolution data. Thus, it is suggested that the explanatory power of trend estimation models alone cannot be always used for the selection of an optimal model in spatial downscaling with fine resolution auxiliary variables.

Research of Phase Correlation Method for Identifying Quantitative Similarity in Adjacent Real-time Streaming Frame

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.157-157
    • /
    • 2017
  • To minimize the damage by wild birds and acquire the benefits such as protection against weeds and maintenance of water content in soil, the mulching black color vinyl after seeding should be carried out. Non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. Non-linear integral interpolation was one of method for analyzing the frequency using the normalization image and then arbitrarily increasing the limited data value of $16{\times}4pixels$ in one frame. It was a method to relatively reduce the size of overlapping pixels by arbitrarily increasing the limited data value. The splitted frames into 0.1 units instead of 1 pixel can propose more than 10 times more accurate and original method than the existing correction method. The non-integral calibration method was conducted by applying the subdivision method to the pixels to find the optimal correction resolution based on the first reversed frequency. In order to find a correct resolution, the expected location of the first crop was indicated on near pixel 4 in the inversion frequency. For the most optimized resolution, the pixel was divided by 0.4 pixel instead of one pixel to find out where the lowest frequency exists.

  • PDF

Flood Runoff Analysis using TOPMODEL Linked with Muskingum Method - Anseong-cheon Watershed - (TOPMODEL과 Muskingum 기법을 연계한 안성천 유역의 홍수유출 분석)

  • Kwon, Hyung-Joong;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.6 no.1
    • /
    • pp.1-11
    • /
    • 2003
  • In this study, TOPMODEL(TOPography based hydrologic MODEL) was tested linked with Muskingum river routing technique for $581.7km^2$ Anseong-cheon watershed. Linear trend surface interpolation was used to give flow direction for flat areas located in downstream watershed. MDF (multiple flow direction) algorithm was adopted to derive the distribution of ln(a/$tan{\beta}$) values of the model. Because the coarser DEM resolution, the greater information loss, the watershed was divided into subwaterhseds to keep DEM resolution, and the simulation result of the upstream watershed was transferred to downstream watershed by Muskingum techniques. Relative error of the simulated result by 500 m DEM resolution showed 27.2 %. On the other hand, the relative error of the simulated result of 300 m DEM resolution by linked 2 subwatersheds with Muskingum method showed 15.8 %.

  • PDF

A Monochromatic X-Ray CT Using a CdTe Array Detector with Variable Spatial Resolution

  • Tokumori, Kenji;Toyofuku, Fukai;Kanda, Shigenobu;Ohki, Masafumi;Higashida, Yoshiharu;Hyodo, Kazuyuki;Ando, Masami;Uyama, Chikao
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.411-414
    • /
    • 2002
  • The CdTe semiconductor detector has a higher detection efficiency for x-rays and $\square$amma rays and a wider energy band gap compared with Si and Ge semiconductor detectors. Therefore, the size of the detector element can be made small, and can be operated at room temperature. The interaction between a CdTe detector and incident x-rays is mainly photoelectric absorption in the photon energy range of up to 100 keV. In this energy range, Compton effects are almost negligible. We have developed a 256 channel CdTe array detector system for monochromatic x-ray CT using synchrotron radiation. The CdTe array detector system, the element size of which is 1.98 mm (h) x 1.98 mm (w) x 0.5 mm (t), was operated in photon counting mode. In order to improve the spatial resolution, we tilted the CdTe array detector against the incident parallel monochromatic x-ray beam. The experiments were performed at the BL20B2 experimental hutch in SPring-8. The energy of incident monochromatic x-rays was set at 55 keV. Phantom measurements were performed at the detector angle of 0, 30 and 45 degrees against the incident parallel monochromatic x-rays. The linear attenuation coefficients were calculated from the reconstructed CT images. By increasing the detector angle, the spatial resolutions were improved. There was no significant difference between the linear attenuation coefficients which were corrected by the detector angle. It was found that this method was useful for improving the spatial resolution in a parallel monochromatic x-ray CT system.

  • PDF

An Experimental Study of the Synthetic Sinc Wave in Ultrasonic Imaging (초음파 의료 영상에서 합성 Sinc 음장 집속방법의 실험적 고찰)

  • 이광주;정목근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.243-251
    • /
    • 2002
  • Synthetic zinc wave employs Pulsed plane wave as transmit beam with linear time delay curve. The received echoes in different transmit directions at different transmit times are superposed at imaging Points with Proper time delay compensation using synthetic focusing scheme. This scheme. which uses full aperture in transmit, obtains a high SNR image, and also features high lateral resolution by using two way dynamic focusing at all imaging depths. In this Paper, we consider the Problems in realization of synthetic zinc wave. Also. we have applied the scheme to obtain phantom and in-vivo images using a linear array of 5 MHz. In phantom test. experimental images show high resolution over a more extended imaging depth than conventional fixed Point transmit and receive dynamic focusing schemes In-vivo images show that the resolution could not overcome conventional focusing systems because of motion blurring and(or) aberration of tissue. but the frame rate tan be increased by a factor of more than 5 compared to conventional focusing schemes. with competitive resolution at all imaging depths .