• 제목/요약/키워드: linear pump

검색결과 179건 처리시간 0.03초

Analysis of activated colloidal crud in advanced and modular reactor under pump coastdown with kinetic corrosion

  • Khurram Mehboob;Yahya A. Al-Zahrani
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4571-4584
    • /
    • 2022
  • The analysis of rapid flow transients in Reactor Coolant Pumps (RCP) is essential for a reactor safety study. An accurate and precise analysis of the RCP coastdown is necessary for the reactor design. The coastdown of RCP affects the coolant temperature and the colloidal crud in the primary coolant. A realistic and kinetic model has been used to investigate the behavior of activated colloidal crud in the primary coolant and steam generator that solves the pump speed analytically. The analytic solution of the non-dimensional flow rate has been determined by the energy ratio β. The kinetic energy of the coolant fluid and the kinetic energy stored in the rotating parts of a pump are two essential parameters in the form of β. Under normal operation, the pump's speed and moment of inertia are constant. However, in a coastdown situation, kinetic damping in the interval has been implemented. A dynamic model ACCP-SMART has been developed for System Integrated Modular and Advanced Reactor (SMART) to investigate the corrosion due to activated colloidal crud. The Fickian diffusion model has been implemented as the reference corrosion model for the constituent component of the primary loop of the SMART reactor. The activated colloidal crud activity in the primary coolant and steam generator of the SMART reactor has been studied for different equilibrium corrosion rates, linear increase in corrosion rate, and dynamic RCP coastdown situation energy ratio b. The coolant specific activity of SMART reactor equilibrium corrosion (4.0 mg s-1) has been found 9.63×10-3 µCi cm-3, 3.53×10-3 µC cm-3, 2.39×10-2 µC cm-3, 8.10×10-3 µC cm-3, 6.77× 10-3 µC cm-3, 4.95×10-4 µC cm-3, 1.19×10-3 µC cm-3, and 7.87×10-4 µC cm-3 for 24Na, 54Mn, 56Mn, 59Fe, 58Co, 60Co, 99Mo, and 51Cr which are 14.95%, 5.48%, 37.08%, 12.57%, 10.51%, 0.77%, 18.50%, and 0.12% respectively. For linear and exponential coastdown with a constant corrosion rate, the total coolant and steam generator activity approaches a higher saturation value than the normal values. The coolant and steam generator activity changes considerably with kinetic corrosion rate, equilibrium corrosion, growth of corrosion rate (ΔC/Δt), and RCP coastdown situations. The effect of the RCP coastdown on the specific activity of the steam generators is smeared by linearly rising corrosion rates, equilibrium corrosion, and rapid coasting down of the RCP. However, the time taken to reach the saturation activity is also influenced by the slope of corrosion rate, coastdown situation, equilibrium corrosion rate, and energy ratio β.

A CMOS 5.4/3.24-Gbps Dual-Rate CDR with Enhanced Quarter-Rate Linear Phase Detector

  • Yoo, Jae-Wook;Kim, Tae-Ho;Kim, Dong-Kyun;Kang, Jin-Ku
    • ETRI Journal
    • /
    • 제33권5호
    • /
    • pp.752-758
    • /
    • 2011
  • This paper presents a clock and data recovery circuit that supports dual data rates of 5.4 Gbps and 3.24 Gbps for DisplayPort v1.2 sink device. A quarter-rate linear phase detector (PD) is used in order to mitigate high speed circuit design effort. The proposed linear PD results in better jitter performance by increasing up and down pulse widths of the PD and removes dead-zone problem of charge pump circuit. A voltage-controlled oscillator is designed with a 'Mode' switching control for frequency selection. The measured RMS jitter of recovered clock signal is 2.92 ps, and the peak-to-peak jitter is 24.89 ps under $2^{31}-1$ bit-long pseudo-random bit sequence at the bitrate of 5.4 Gbps. The chip area is 1.0 mm${\times}$1.3 mm, and the power consumption is 117 mW from a 1.8 V supply using 0.18 ${\mu}m$ CMOS process.

자성유체의 형상에 따른 선형 펌프의 펌핑력에 관한 연구 (Research of Pumping Force according to Shape of Magnetic Fluid in Magnetic Fluid Linear Pump)

  • 서강;박관수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.981-983
    • /
    • 2005
  • 자성유체를 이용하여 동작하는 선형 펌프를 개발하였다. 자성유체의 자기적 성질을 이용하여 구동하는 선형펌프로 일반 펌프에 비해 조가 간단하고, 진동/소음이 작다는 장점이 있다. 또한 외부에서 인가하는 자기장의 조절만으로 펌프를 조절할 수 있다. 개발한 펌프는 자성유체의 관내에서의 형상에 따라 펌핑력이 매우 달라진다. 따라서 외부에서 인가하는 자기장에 의해 형성되는 자성유체의 형상을 해석하고, 이로 인해 형성되는 자성유체에 의해 발생하는 펌핑력을 측정하고 비교하였다.

  • PDF

천연가스 기화기용 해수배관망 해석에 관한 연구 (A Study on the Analysis of Seawater Pipeline Network for Open Rack Vaporizers)

  • 김호연;박종학;이정환;김동혁
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1760-1764
    • /
    • 2003
  • This study was carried out to establish an analytical method on the open circuit seawater pipeline network for open rack vaporizers(ORVs). The linear theory method was chosen to solve this network system. In particular, the method was modified to calculate the static pressure at each node and to determine the operating condition of each pump with the mean static pressure of pumps and ORVs. The proposed method is the first report demonstrating that can be used as a solver for the complicated open circuit. Also, the method indicated the importance for exactly calculating equivalent length of pipes including valves, bends, fittings, and others to raise the accuracy. Although this technique is good for solving this system, it is still required to improve the convergence rate.

  • PDF

스프링 댐퍼를 이용한 가동 자석형 리니어 진동 엑추에이터의 설계 및 특성해석 (Design and Characteristic Analysis of Moving Magnet Type Linear Oscillatory Actuator with Spring Damper)

  • 조성호;김덕현;김규탁
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권1호
    • /
    • pp.9-15
    • /
    • 2003
  • This Paper deals with the design of Moving Magnet type Linear Oscillatory Actuator(MM-LOA) using spring damper based on the design procedure and the characteristic analysis. MM-LOA is applied to variable load such as vaccum pump and compressor, The structure of piston type is selected to reduce a noise. MM-LOA has over-displacement in starting state because of the low inertia of mover To improve the starting characteristic, spring damper is used. The optimum spring constant of spring damper is detected and in consideration of spring damper, MM-LOA redesigned. The parameter is calculated by Finite Element Method(FEM). For the dynamic characteristic analysis, time differential method composed of voltage and kinetic equation is used. The propriety of the improved model is verified through the experimental results.

뇌파 분석 시스템에서의 Artifact 제거를 위한 적응 기법에 관한 연구 (A Study on the Adaptive Technique for Artifact Cancelling in Electroencephalogram Analysis System)

  • 유선국;김기만;남기현
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.389-396
    • /
    • 1997
  • 본 논문에서는 뇌파측정기에서 발생하는 전기적 잡음을 제거하기 위하여 뇌파 측정시 발생하는 안구운동, PVC 룰러 펌프 잡음등을 포함하는 전기적 잡음에 대하여 기술하였다. 적응 디지틀 필터는 이러한 뇌파 측정 잡음을 제거하는 효과적인 방법이다. 그러나 일반적인 적응 디지틀 필터는 뇌파신호의 일부주파수 성분에 영향을 주게되므로 자동 뇌파 처리에는 부적합하다. 그러므로 본 고에서 이러한 뇌파잡음을 제거하기 위하여 제안한 방법은 일반적인 적응디지틀 필터의 참조채널을 사용하지 않으며, EOG 잡음을 제거하기 위하여 선형예측기와 고정차수 FIR 필터를 연결하였으며, 펌프잡음을 제거하기 위하여 선형예측기와 잡음 제거기를 연결함으로써 실현하였다. 또한 시뮬레이션을 통한 결과는 잡음제거 능력의 관점에서 제안한 방법의 성능을 분석하였으며, 결과적으로 약 20dB의 잡음제거 성능을 보였다.

  • PDF

초대형 열교환기용 열판 성형을 위한 22,000Ton급 유압 프레스 개발 (Development of 22,000Ton Hydraulic Press for the Forming of Heat Plate with Ultra-Large Size)

  • 임성주;박훈재;윤덕재;김응주;임혁;나경환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2001년도 추계학술대회 논문집
    • /
    • pp.166-169
    • /
    • 2001
  • 22,000 Ton hydraulic press was developed using wire winding method. The hydraulic press consists of three piece of frame type. The outer layers of yoke-column frame and main cylinder linear were wound with piano wire(1mm${\times}$4mm) under controlled tension and the total length of wound wire was about 450Km. The developed hydraulic press is used for the forming of heat plate with ultra-large size. To obtain large force with relative small apparatus, high pressure of $1,500 Kgf/cm^2$ was supplied to main cylinder through pressure amplification by booster pump. Therefore sealing technique of main cylinder is so crucial that the seals were made of mitre ring type with super-elastic metal. The press total weight is about 150 tons, which is quite light and compact relative to that of conventional hydraulic press.

  • PDF

Cavitation in Pump Inducer with Axi-asymmetrical Inlet Plate Observed by Multi-cameras

  • Kim, Jun-Ho;Atono, Takashi;Ishizaka, Koichi;Watanabe, Satoshi;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권2호
    • /
    • pp.122-128
    • /
    • 2010
  • The attachment of inducer in front of main impeller is a powerful method to improve cavitation performance; however, cavitation surge oscillation with low frequency occurs with blade cavity growing to each throat section of blade passage simultaneously. Then, one conceptual method of installing suction axi-asymmetrical plate has been proposed so as to keep every throat passage away from being unstable at once, and the effect on suppression of the oscillation were investigated. In the present study, cavitation behaviors in the inducer is observed with distributing multi-cameras circumferentially, recording simultaneously and reconstructing multi-photos on one plane field as moving a linear cascade. Observed results are utilized for discussion with other measuring results as casing wall pressure distribution. Then the suppression mechanism of oscillation by installing axi-asymmetrical inlet plate will be clarified in more details.

Mid-infrared Continuous-wave Optical Parametric Oscillator with a Fan-out Grating MgO:PPLN Operating Up to 5.3 ㎛

  • Bae, In-Ho;Yoo, Jae-Keun;Lim, Sun Do;Kim, Seung Kwan;Lee, Dong-Hoon
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.577-582
    • /
    • 2019
  • We report on a continuous-wave (cw) optical parametric oscillator (OPO) optimized for mid-infrared emission above 5.0 ㎛. The OPO is based on a magnesium-oxide-doped periodically poled LiNbO3(MgO:PPLN) crystal with a fan-out grating design. A linear two-mirror cavity resonating both at the pump and signal wavelengths is stabilized to the pump laser by using the modified Pound-Drever-Hall (PDH) method. The idler wavelength is continuously tunable from 4.7 ㎛ up to 5.3 ㎛ by varying the poling period of the fan-out grating crystal. Pumped by a diode-pumped solid state (DPSS) laser with a power of 1.1 W at 1064 nm, the maximum idler output power is measured to be 5.3 mW at 4.8 ㎛. The output power above 5.0 ㎛ is reduced to the hundreds of ㎼ level due to increased absorption in the crystal, but is stable and strong enough to be measured with a conventional detector.